RIBA RCI-15 User manual

RCI-15 ZSME300000050


RCI-15
1
ZSME300000050
222
CONTENT
222
SpecialNotice..........................................................................................................3
Safety.......................................................................................................................4
Features...................................................................................................................5
CHAPTER1FRONTAND REARPANELSPECIFICATIONS................................6
1-1 Front panel...................................................................................................6
1-2 Keyboard description...................................................................................7
1-3 Assemblydiagram.......................................................................................8
1-4 A/DConversion............................................................................................8
1-5 Powersupply...............................................................................................8
1-6 Circuit board description..............................................................................9
1-7 Indicator appearance.................................................................................10
CHAPTER2GENERALFUNCTIONGUIDE.........................................................11
2-1 Function setup andoperationprocedures.................................................11
2-2 Function setting .................................................................14
CHAPTER3CALIBRATION..................................................................................17
3-1 Load cell connection..................................................................................17
3-2 Parametersettingand calibration flowchart.............................................18
3-3 Specificationcalibration ....................................................20
3-4 GeneralCalibration ...........................................................22
3-5 Linearitycalibration ...........................................................23
3-6 Digitalcalibration
.........................................................25
3-7 Calibration Error Messages.......................................................................26
CHAPTER4WEIGHTCOMPARISONPROCEDURES.......................................27
4-1 Function configuration menu.....................................................................27
4-2 Checkweighing configuration...................................................................30
4-3 Batchingsignaloutputs.............................................................................33
4-4 Normalbatching flowchart (SQ-01=1)......................................................34
4-5 Loss-inWeight flowchart(SQ-01=2)....................................................35
4-6 Hi, OK,Looutput flowchart......................................................................36
4-7 Normalbatching (built-inprogram)flowchart(SQ-01=4).........................37
4-8 Loss-inWeight (built inprogram)(SQ-01=5)............................................38
4-9 Holdmode(SQ-01=6).............................................................................39
4-9-1 Holdmodeflowchart.......................................................................40
4-9-2 Hi, OK,Locomparison.....................................................................41
4-10Totalizing (ACCU.)Auto/ Transmit..........................................................41

RCI-15
2
ZSME300000050
CHAPTER5INTERFACE......................................................................................42
5-1 Serialinput/output interface(OP-01).........................................................42
5-2 AnalogueCurrent/ VoltageOutputInterface(OP-03)..............................50
5-3 Externalparallelinput/ output interface(OP-04,OP-05).........................53
CHAPTER6MAINTENANCE...............................................................................58
6-1 Restoreall parameterstotheirdefault factoryvalues..............................58
6-2 Maintenancefunctionparameters.............................................................58
6-2-1 Restorethefunction parameterbacktoitsdefault value................59
6-2-2 Clearzerocompensationand TAREvalues....................................59
6-2-3 Clearbatchsetting...........................................................................59
6-2-4 Displayzero voltage(mV/V)............................................................59
6-2-5 Clearbatchsetting...........................................................................60
6-3 Testmode..................................................................................................61
6-3-1 7segment displaytesting................................................................62
6-3-2 KeypadandcalibrationSWtesting..................................................62
6-3-3 DisplayA/Dinternalvaluedisplay....................................................62
6-3-4 RS-232 serialloop backtesting.......................................................62
6-3-5 EEPROMmemorytesting................................................................62
6-3-6 Option interfacecardtesting............................................................62
APPENDIXI Description of7segmentcharacters................................................64
APPENDIXII FunctionTable.................................................................................65

RCI-15
3
ZSME300000050
SpecialNotice
The indicator isIP67waterproofdesign.Onlythecableswith 4~ 7mm
calibrecouldbeused or willaffectthewaterproof design.
Insome certainconditions, the stainlesscaseofindicator wouldbeopenedto
set upthe loadcell, toconnect the power cable, ortochange thenew
rechargeablebattery.
Beforeopenthe stainlesscase,pleasemakesure theindicator isdry, if
necessarythe liquidshouldbewiped off.
The assemblingnoticeshouldbeaccuratelyfollowedtoassurethe
waterproof performance.Wealsostronglysuggestthat theseproceduresshould
be operated bythetechnicalstaffofyour supplier.
ASSEMBLING NOTICE:
Afterthedesired stepsaredone, screwthe casewith12kgf-cminthe
followingorders.Donot screwtightlybeforeall screwsare inthepositions.
Screwingorders:
1
st
2
nd
3
rd
4
th
5
th
6
th

RCI-15
4
ZSME300000050
Safety
2Whentheinstrumentisinstalled, connect anearthbondingconductor
fromFG totheearthconnectionmarked ”.
2Disconnect themainspowersupplybeforeopeningtheinstrument
housing.NOTE:Therearenouserserviceablepartsinside.
2Toinstall theoptional interfacecards,itisnecessarytodisconnect the
mainspowersupplyandfitayellow/greenearthbondingcabletothe
rearpanel.
2Beforeturningthepoweronensurethesupplyvoltageiswithinthe
acceptablerange,AC100V~AC240V.
2Theoperatingambienttemperaturerangeis-10oC~+40oC.
(+14°F~+104°F)
2TheindicatorisIP67 waterproofdesign.Onlythecables with
4~ 7mm calibrecouldbeusedorwill affectthewaterproofdesign.

RCI-15
5
ZSME300000050
Features
RCI-15hasawiderange ofapplicationsfrombatchingtosimpleweighing.
Features:
IP67 Waterproof design
Stand alone batchingmode orconnect toPLCforexternalsystemcontrol
Builtinbatching / dosing functions
Manual/ automaticdischarge operation
Set cycletimesinabatch
Totaliseweight andnumberof cycles
Keyinthesignalvoltage value(mV/V)directlyviathe keyboard, no need toapply
anyweight tothe bottomworktocalibratethe weigher.
Displayload celloutput voltage(mV/V)forfuturemaintenance
Adjustablefilter
RS232Cbi-directionalandcurrentlooponewayserialinterface
Interface options:
OP-01RS422/485/232serialinterface
OP-0316 BitAnalogue current/voltage outputinterface
(4~20 mA/ 0~10V)
OP-04ControlI/O (4In/4Out)+Setpoint In(BCD code)
OP-05ControlI/O (8In/8Out)

RCI-15
6
ZSME300000050
CHAPTER 1FRONTAND REARPANEL
SPECIFICATIONS
1-1Frontpanel
Display
•6digits, bright red,7segment LEDdisplay, characterheight16mm(0.63 ).
Displaycanbe switched between Gross Weight/ NetWeight/Totalised Weight/
Numberof transactionsinthe total.
•Indication icons “◄
ZERO ◄: ZeroIndication
MD ◄:Unstableweight Indication
GROSS ◄: Gross weightIndication
NET ◄: Net weight Indication
♦The indicatorissupplied withsuitablelabelstocustomisethe icon displays.Referto
FNC. 07 ~FNC.10forthe variousoptionsavailable.
2WeighingUnits
♦WeighingUnitskg/ g/t / lb.
F2F F1
Tare
Zero G/N
RCI
-
15

RCI-15
7
ZSME300000050
1-2Keyboard description
:
Inthe normalmode, it performsasZerooperation.
:
Whenparametersetting,itincrementsthe flashingdigit orstepsupthe
selectitem.
Inthe normalmode, it performsaGross/Net switchoperation.
:
Inthe normalmode, it performsasTareoperation.
:
Whenparametersetting,itmoveflashing toright.
Inthe normalmode, it accessesthe FNC-06 setting.
:
Whenparametersetting,itdecrementsthe flashingdigit orstepsdown
the selectitem.
Inthe normalmode, it accessesthe FNC-05 setting.
:
Whenparametersetting,itmoveflashing toleft.
Inthe normalmode, it accessesthe FNC-04 setting.
:
Confirm/ enterkey
4Function FNC-03can beused toselectivelydisableindividualkeys.
4Zerooperation, willbe limited byfunctionsCSP-05 and CSP-10.
4Zerooperation, willbe limited byfunctionsCSP-10 and CSP-11.
:
Whenentering dataorreferencesetting,it means “ESC .
Inthe normaloperation,it putsthe indicatorinstandbymode orescape.
Entering standbymode:All ofthe display(except ZERO “3symbol)and
serialdataoutputaredisabled.
Escapefromstandbymode:Re-poweronmainsfornormaloperation.
Zero
G/N
•
Tare
F2
„
F1
‚
F
ƒ

RCI-15
8
ZSME300000050
1-3Assemblydiagram
1-4A/DConversion
*Input Sensitivity
*InternalResolution
*Max. Sampling Speed
*Application Range
*Load CellExcitationVoltage
: Upto0.12uV/D
: 1/ 1,000,000
: 120 times/sec.
: -0.1mV/V~4.0mV/V
: 5VDC ±5%, 120mA
(Uptoeight (8)350 Ωloadcellscan be connected)
1-5Powersupply
♦AC100V~240V50/60Hz
♦Powerconsumption isabout 10VA
正面
背面
OP-01
OP-03
OP-05
OP-04
Back
Front

RCI-15
9
ZSME300000050
J1~J4RS232/422
short 12->RS422
short 23->RS232
J54Wire/WireRS-
short 12->4Wire
short 23->2Wire
InputACPower
86~240V
FrameGround
CN6
OFF
ON
ON 校正開關
開關方向往上
為"ON",亦即進入
校正模式,開關方
向往下為"OFF",亦
即一般使用模式
OFF
SW1
CN1
CN5與OP-03-CN2,
OP-04-CN3,
OP-05-CN3相連接
EXC+
SHLD
SIG-
SIG+
EXC-
SEN-
SEN+
J5
1
2
3
CN4
422
1
2
3
J1 J2 J3 J4
1-6Circuitboard description
CN, OP-03-CN2,
OP-04-CN3and
OP-05-CN3are
connected.
Onisthe
calibration
modestatus.
Offisthe
normalmode
status.
100V~240V

RCI-15
10
ZSME300000050
1-7Indicatorappearance
Frontview Upview
Back view Sideview

RCI-15
11
ZSME300000050
CHAPTER 2GENERALFUNCTION GUIDE
2-1Function setupand operation procedures
Function Operation Display Description
Entercalibration mode
Turnthe calibration switchto “ON
See 3-2fordetails
Enterfunction setting Press not release,
then presskey
afterthe poweristurned on See 2-2fordetails
Reset all parameters
back todefault
Turnthe poweron then turnthe
calibrationswitchto “ON then
pressand holdthe
and keys
during the self-testing sequence
. See 6-1fordetails
Reset generalfunction
parametersback to
default
Turnthe poweron and
Press and keys
during self-testing sequence See 6-2-1fordetails
Clearzeropoint
compensation and tare
value
Turnthe poweron and
pressand keys
during self-testing sequence, and
then press
See 6-2-2fordetails
Clearsetpoint parameter
setting
Turnthe poweron and
pressand keys
during self-testing sequence, and
then presstwotimes
See 6-2-3fordetails
Value of zeropoint
voltage(mV/V)
Turnthe poweron and
Press and ,then
pressthree times.
See 6-2-4fordetails
Value of Span voltage
(mV/V)
Turnthe poweron and
Press and ,then
Press
See 6-2-5fordetails
Entering totestmode
Turnthe poweron and
pressand keys
during self-testing sequence
.See 6-3fordetails
F
ƒ
F
ƒ
F
ƒ
F
ƒ
G/N
•
F
ƒ
G/N
•
G/N
•
F
ƒ
F
ƒ
F1
‚

RCI-15
12
ZSME300000050
Function Operation Display Description
Check weighing setpoint
parametersetting
Press the keytoset
the parameterofFUNC.4to1in
the normal mode
.
or
.
See 4-2fordetails
4Keyactionsinfunctionset upmode
⇒Increasesthe numberof the flashingdigit
⇒Decreasesthe numberof theflashing digit
⇒Movestheflashing digit onespacetothe left
⇒Movestheflashing digit onespacetothe right
⇒Savesthe configuration
⇒Quitsset up mode / Escape
F2
„
F
ƒ
G/N
•
F1
‚
F
ƒ

RCI-15
13
ZSME300000050
FunctionSetting
FirstSerialPortInterface
Second SerialPort
Interface
BCD ParallelPortoutput
interface
Analoguecurrent/ voltage
outputinterface
Externalparallelcontrol
inputinterface
Externalparalleltripoutput
interface
4FunctionSettingProcedures
Withweight displayed press and holdthe key.Then, press
See 5-1fordetails
See 5-2fordetails
See 5-3fordetails
See 5-1fordetails
See FunctionSetting 2-2
fordetails
See Chapter4fordetails
See 5-4fordetails
See 5-4fordetails
Set Point Procedure
F1
‚
F1
‚
F1
‚
F1
‚
F1
‚
F1
‚
F1
‚
F1
‚
F1
‚
G/N
•
G/N
•
G/N
•
G/N
•
G/N
•
G/N
•
G/N
•
G/N
•

RCI-15
14
ZSME300000050
2-2Function setting
Press
Input desired
Parametercode
Press
Displayshowsthe
previousparameter
code. Input the new
code asrequired
press
Tocontinue the next functionsetting
orpress toescape
⇒Incrementflashing
digit
⇒Decrement flashing
digit
⇒Moveflashing point
left.
⇒Moveflashing point
right
⇒Storedatain
memory
⇒Exit / Escape
*FunctionParametercode
⇒DigitalFilter I
⇒DigitalFilter II
⇒Lock keypad function
⇒“Ffunction setting
⇒“F1 functionsetting
⇒“F2 functionsetting
⇒Front panelindication “S1 settingstatus
⇒Front panelindication “S2 settingstatus
⇒Front panelindication “S3 settingstatus
⇒Front panelindication “S4 settingstatus
⇒Termsofback tozero
⇒Hold
⇒Displaytherateof refreshment
G/N
•
F1
‚
F
ƒ
F2
„

RCI-15
15
ZSME300000050
2FNC Groupfunction setting
Settingvalue
Item Function Parameter
Description Default
0 5 Hz
1 4.17 Hz
2 2.5Hz
3 2.08 Hz
4 1.25 Hz
5 1.04 Hz
6 0.63 Hz
7 0.52 Hz
8 0.31 Hz
FNC-01
DigitalFilterI
9 0.26 Hz
4
0 Disabled
1
2
3
4
FNC-02
DigitalFilterII
5
Less filter
Greater
2
0
Normal
(lock disable)
FNC-03
Key –Locked 000000
↓
111111 1
Close
(lock enable)
000000
TareG/NZeroF2F1F000000
FNC-04
“Ffunction setting 0
FNC-05
“F1 functionsetting 1
FNC-06
“F2 functionsetting
Parameter ⇒Description
0 ⇒Setpoint parametersetting
1 ⇒Tarereset
2⇒Manuallyoutput of serial, parallelprint
3⇒Startload
4⇒Stop load
5⇒Start comparison
6⇒Unload command
7⇒Totaliseweightand countscommand
8⇒Cleartotalisedweightand counts
9⇒Holdmode
10 ⇒Escape Holdmode(I/O DSP)
11 ⇒ConverttoGross / Net / totalised weight /
totalisedCount
2

RCI-15
16
ZSME300000050
Settingvalue
Item Function Parameter
Description Default
FNC-07
Front panelindication
“S1 setting 0
FNC-08
Front panelindication
“S2 setting 0
FNC-09
Front panelindication
“S3 setting 0
FNC-10
Front panelindication
“S4 setting
Parameter ⇒Description
0⇒Accu. V
1⇒Accu. C
2⇒SP1
3⇒SP2
4⇒SP3
5⇒Hi
6⇒OK
7⇒Lo
8⇒Under
9⇒Over
10 ⇒Unloading
11 ⇒Running
12 ⇒Hold 0
0 5 d
1 10 d
2 20 d
3 40 d
4 60 d
5 80 d
6 100 d
7 150 d
8 200 d
FNC-11
Returntozeroband
9 250 d
0
0 Hold
1 Peakhold(positive)
2 Peakhold(negative)
FNC-12
Hold
3 Peakhold(absolutevalue)
0
0 Nolimitation
1 20 times/sec
2 10 times/sec
3 5 times/sec
FNC-13
Ratefordisplayrewrite
4 1 time/sec
0
4The indicationsof FNC-07~FNC-10arenecessarilyoperated withOPTIONCARD.

RCI-15
17
ZSME300000050
SEN+
SHLD
SIG-
EXC-
SIG+
SEN-
EXC+
SEN+
SEN-
EXC+
EXC-
Shield
SIG+
SIG-
CHAPTER 3CALIBRATION
3-1Load cell connection
2When using a6wirecabletoconnectthe loadcell,theSEN+ and SEN-can
be leftunconnected (seebelowdiagram)

RCI-15
18
ZSME300000050
3-2Parametersettingand calibration flowchart
Specification Calibration GeneralCalibration LinearityCalibrationDigitalCalibration
Calibration
SwitchON
ZeroPoint
Voltage
Calibration
SpanVoltage
Calibration
Select 1Point for
Weight Calibration
(1P~5P)
CalibrationSwitch
OFF
Calibration
Completed
Zeropoint
Calibration
Weight Calibration
Table of contents