17
5.5 Draining the heating circuit of the boiler
Before draining the system, switch off the electrical supply by
turning off the main switch of the system.
−close the heating system’s valves
−manually loosen the system drain valve (C).
B
A
C
5.6 Emptying the domestic hot water system
Whenever there is risk of freezing, the domestic hot water system
must be emptied in the following way:
−turn off the main water supply tap
−turn on all the hot and cold water taps
−drain from the lowest points.
9 DANGER: The system water temperature could be very hot,
be sure when opening the drain valve that the rubber pipe
is well attached. Water could spray from the front of the unit
and cause instant severe burns or death from scalds.
6 WHAT IF...
6.1 WHAT IF I SUSPECT A GAS LEAK
If you suspect a gas leak, turn off the gas supply at the gas meter
and contact your installer or local gas supplier. If you require
further advice please contact a qualied Service Technician.
6.2 WHAT IF I HAVE FREQUENTLY TO INCREASE THE
SYSTEM PRESSURE
If the system regularly requires the pressure increased, it may be
indicative of a leak. Please contact your installer and ask him to
inspect the system.
6.3 WHAT IF THE APPLIANCE IS DUE ITS ANNUAL
SERVICE
Advice for tenants only
Your landlord should arrange for servicing.
Advice for homeowners
9 NOTICE: Please contact your qualied local service technician
to have your appliance serviced. If you do not have a service
technician, please contact your local Riello distributor and
they will provide you with a recommendation.
9 WARNING: Failure to have the boiler properly serviced and
inspected on a regular basis by a qualied service technician
may result in property damage, serious injury or death.
9 WARING: Failure to keep the Vent and Combustion Air-intake
clear of ice, snow, and other debris may result in property
damage, serious injury, or death.
6.4 WHAT IF I NEED TO CALL A SERVICE TECHNICIAN
If you think your boiler may have developed a fault, please
contact your installer or your local R distributor.
Have all your details in hand including full address, relevant
contact numbers and your complete boiler serial number.
7 MAINTENANCE
7.1 SUGGESTED MINIMUM MAINTENANCE SCHEDULE
Regular service by a qualied service agency and maintenance
must be performed to ensure maximum operating efciency.
Periodic maintenance is essential to the safety, efciency and
lifetime of the boiler.
It allows for the reduction of consumption, polluting emissions
and keeping the product reliable over time.
The frequency of servicing will depend upon the particular
installation conditions, but in general, once per year should be
sufcient. It is the law that any service work is carried out by a
competent person such as a qualied technician, an approved
service agent, or other suitably qualied personnel.
9 WARNING: Service should only be carried out by a qualied
service technician. This appliance produces carbon
monoxide (CO) gases. The venting should never be taken
apart by anyone other than a qualied technician. The
venting should not be separated. Failure to comply may
result in severe personal injury or death.
9 WARNING: To avoid electric shock, disconnect electrical
supply before performing maintenance.
9 WARNING: Annual service should ONLY be performed by a
qualied service agency. Schedule annual service by calling
a licensed service agency.
-Visually check top of vent for soot. Call service person to clean.
Some sediment at bottom of vent is normal.
-Visually inspect all flue product carrying areas of the boiler
including the venting system and main burner for proper
function, deterioration or leakage. Ensure that condensate
drains are inspected and ensure that condensate is being
directed to appropriate condensate management system or
drain, as required by local codes.
-Check that area is free from combustible materials, gasoline,
and other flammable vapors and liquids.
-Check for and remove any obstruction to the flow of combustion
or ventilation air to heater.
-Check operation of safety devices. Refer to manufacturers’
instructions.
Listen for water ow noises indicating a drop in boiler water
ow rate
-To avoid potential of severe burn, DO NOT REST HANDS ON OR
GRASP PIPES. Use a light touch; return piping will heat up
quickly.
-Check fan and fan motor.
-Check for piping leaks around pumps, relief valves and
other fittings. Repair, if found. DO NOT use petroleum-based
stopleak.
-Check relief valve. Refer to manufacturer’s instructions on
valve.
-Check the condensate check valve dispositive and, if necessary,
please contact your Service Technician.
Verify proper operation after servicing.
9 WARNING: The pressure relief valve lever must be operated
at least once a year by qualied personnel during annual
maintenance to ensure that water-ways are clear.
Cleaning
-To clean the outer casing use only a clean damp cloth. Do not
use any scourers or abrasive cleaners.
-The Condensate Trap must be periodically disassembled and
cleaned as part of a regular maintenance plan. Failure to
clean the trap regularly can cause condensate drain blockage
leading to boiler malfunction, property damage and even
personal injury.
9 CAUTION: Glycol must be replaced periodically due to
degradation of inhibitors over time. Follow all glycol
manufacturer’s instructions.