Rielta IR-RK User manual

WIRELESS EXECUTIVE RELAY
MODULE
«IR-RK»
1 General Information
1.1 Wireless executive relay «IR-RK» (hereinafter, the «IR-RK») is designed to
connect external peripherals to 230V AC mains.
1.2 The «IR-RK» energizing, de-energizing as well as its modes adjustment
is fulfilled by wireless signal exchange within the 433.05 – 434.79 MHz
frequency range in accordance with the «Rielta-Contact-R» wireless two-way
communication protocol.
1.3 «IR-RK» is intended for operation as a component of a system, that is
operated by a control panel (hereinafter, the CP), supporting «Rielta-Contact-R»
wireless two-way communication protocol.
1.4 Power is supplied from AC mains with rated voltage 230V and frequency
50 Hz.
1.5 The «IR-RK» operation provides the following status indication:
- Communication quality;
- «Binding» mode.
The «IR-RK» modes supervision, as well as identification indication switching
ON/OFF is carried out by the «Rielta-Contact-R» protocol.
1.6 The «IR-RK» generates two types of messages:
- «Norm»;
- «Tamper» – as a result of cover opening.
1.7 The «IR-RK» provides status information with 4 s period.
1.8 Operation modes of the «IR-RK» are displayed by 2 LED indicators (see
Table 3).
1.9 The «IR-RK» is designed to operate continuously around the clock.
2 Principal Technical Characteristics
Table 1
Parameter Value
Rated voltage 230 V (85–305) V,
(50±3) Hz
Maximum consumed power 1,5 VA
Maximum switching current 7 А
IP rating IP30
Dimensions, maximum
66х66х35 mm
Weight, not more than 0,2 kg
Average service life 8 years
Operating temperature minus 30... +50 °С
Permissible humidity at a temperature +35 °С
without moisture condensation 98 %
3 Scope of Delivery
Each «IR-RK» unit package contains the items listed in Table 2.
Table 2
Name QNT
Wireless executive relay «IR-RK»
Antenna
Screw 3-3x30.016
Wall Plug NAT 5x25 SORMAT
Wireless Executive Relay «IR-RK». Installation Guide
1 pc.
1 pc.
2 pcs.
2 pcs.
1 copy
4 Protective Measures
4.1 The «IR-RK» installation and service should be fulfilled in conformity with
accident-prevention rules.
4.2 All installation and assembly operations should be undertaken in OFF mode.
5 Design
The «IR-RK» design with removed cover is shown in Figure 1. The base (1)
is provided with:
- hole (7) for cover fixation;
- two holes (2) for «IR-RK» fixation to installation surface;
- cutout (11) for mains cord wiring.
The printed circuit board (PCB) (3) comprises the following elements:
Installation Guide
- antenna leading-in socket (4);
- green LED indicator (5);
- red LED indicator (6);
- «RESET» contacts (8);
- «TAMPER» contact (9);
- terminal blocks (10).
Figure 1 – The «IR-RK» with removed cover
6 LED Indication
Table 3
Operation Mode LED Indication
«Binding» mode Green LED indicator intermittently blinking
«Binding is
completed» Short-term (2 s) red LED indicator lighting
«Identification»
indication Alternate green and red LED indicators lighting
Switching ON
Short term (2 s) red LED indicator lighting
«Communication
Quality Appraising» See Table 4
7 Switching On and Pre-starting Procedure
7.1 Put off the cover.
7.2 Install antenna to the leading-in socket ( ).
7.3 Prepare the CP for the new device logging («Binding» mode) in accordance
with the CP Installation Guide. Only one CP, prepared for binding, should be
located in radio coverage zone during «IR-RK» logging.
Fulfill «IR-RK» energizing by applying 230 V to «IN» inputs.
7.4 Short-circuit «Reset» pin contacts on «IR-RK» PCB.
7.5 Make sure in green LED indicator intermittent blinking (binding mode).
Remove short-circuit by opening pin contacts.
7.6 Execute binding procedure in accordance with the CP Manual.
7.7 Wait for short-term red LED indicator lighting.
Note: The binding procedure is limited to 100 s. To resume the «Binding»
mode, repeat operations described in sect. 7.5 – 7.8.
8 Communication Quality Appraising
8.1 Place «IR-RK» at the assumed place of installation in a position, which
provides vertical antenna orientation.
8.2 Push «Tamper» contacts and hold it for 3 s or longer.
8.3 Release «Tamper» contacts.
8.4 Appraise the communication quality by LED lighting in accordance with
the Table 4.
Note: Four-second delay is possible before thу LED switching ON
Table 4 – LED Indication for Communication Quality Appraising
LED Indication Communication
quality
appraisal
Recommendations
Color Mode
Green Three blinks Excellent Install «IR-RK» at this place
Green Two blinks Good
Green One blink Communication
established Choose another place
of installation or use
a repeater out of
«Ladoga-RK» product line
Red A series of
blinks
No
communication
9 Outline Drawings
Power wires should have double insulation and wire section of 0,75 – 1,5 mm2.
RESET
V.10
IN OUT
1 2 4 5 6 7 8 9
10 211
3
Figure 2
OUT
IN
230 В
~

10 Installation
10.1 Fulfill communication quality apprising at the assumed place of
installation.
10.2 Install the «IR-RK» at the place, where communication quality is
appraised as «Good» or «Excellent» (See Sect.8)
10.3 It is not recommended to install «IR-RK» at the following places:
- at massive metal constructions and nearer 1 m from them;
- closer than 1 m from electrical power cables, as well as from water or gas
pipes;
- near the source of radio interferences;
- inside metal constructions.
10.4 Install the «IR-RK» in a position, which provides vertical antenna
orientation.
11 Specialties of «IR-RK» Operation
11.1 Communication period of the «IR-RK» is equal to 4 s. Command on
communication period change should be ignored.
11.2 The «IR-RK» supports the following modes of load connection:
- ON;
- OFF;
- On at a frequency 1 Hz;
- On at a frequency 0,5 Hz.
All modes can be trigged constantly or for a time from 1 to 2 500 s
11.3 Maximum switching current is meant for the resistance load. Cos ϕ
reduction declines maximum switching current.
12 Storage and Transportation
12.1 The «IR-RK» in their original packing may be shipped by any transport
means in closed vehicles over any distances in compliance with the existing
shipping rules concerning the respective means of transportation.
12.2 The storage premises should not contain any current-conducting dust,
acid and alkali fumes, or corrosive or destroying insulation gases.
13 Post-consumer Recycling Data Sheet
13.1 The «IR-RK» does not contain precious metals, dangerous and toxic
substances enabled to injure human’s health or environment. The relay on
expiry it’s working time does not to pose direct threat to life and health of
people, as well as an environment.
13.2 Post-consumer recycling may be fulfilled by the rules of conventional
equipment recovery.
14 Manufacturer’s Guarantees
14.1 The manufacturer guarantees conformity of the «IR-RK» to its Technical
Specifications provided that the transportation, storage, installation and operation
conditions are observed.
14.2 The guaranteed shelf life of the «IR-RK» is 63 months since the date of
manufacture.
14.3 The guaranteed useful life is 60 months since the day of putting into
operation within the guaranteed shelf life.
14.4 The «IR-RK» that is found non-conforming to the Technical Specifications
shall be repaired by the manufacturer, provided the installation and operation
rules have been complied with.
Rev. 0 of 11.04.19
v10
«RIELTA» JSC, www.rielta.com
Tel./fax: +7 (812) 233-0302, 703-1360
Made in Russia