RIGOL TECHNOLOGIES CO., LTD.

Installation Guide RIGOL
1
Guaranty and Declaration
Copyright
© 2020 RIGOL TECHNOLOGIES CO., LTD. All Rights Reserved.
Trademark Information
RIGOL® is the trademark of RIGOL TECHNOLOGIES CO., LTD.
Publication Number
RKD27100-1110
Notices
RIGOL products are covered by P.R.C. and foreign patents, issued and pending.
RIGOL reserves the right to modify or change parts of or all the specifications and
pricing policies at the company’s sole decision.
Information in this publication replaces all previously released materials.
Information in this publication is subject to change without notice.
RIGOL shall not be liable for either incidental or consequential losses in connection
with the furnishing, use, or performance of this manual, as well as any information
contained.
Any part of this document is forbidden to be copied, photocopied, or rearranged
without prior written approval of RIGOL.
Product Certification
RIGOL guarantees that this product conforms to the national and industrial standards in
China as well as the ISO9001:2015 standard and the ISO14001:2015 standard. Other
international standard conformance certifications are in progress.
Contact Us
If you have any problem or requirement when using our products or this manual, please
contact RIGOL.

Installation Guide RIGOL
3
Safety Notices and Symbols
Safety Notices in this Manual:
WARNING
Indicates a potentially hazardous situation or practice which, if not avoided, will
result in serious injury or death.
CAUTION
Indicates a potentially hazardous situation or practice which, if not avoided,
could result in damage to the product or loss of important data.
Safety Terms on the Product:
DANGER It calls attention to an operation, if not correctly performed, could result in injury
or hazard immediately.
WARNING It calls attention to an operation, if not correctly performed, could result in
potential injury or hazard.
CAUTION It calls attention to an operation, if not correctly performed, could result in
damage to the product or other devices connected to the product.
Safety Symbols on the Product:
Hazardous
Voltage
Safety
Warning
Protective
Earth
Terminal
Chassis
Ground
Test
Ground

Installation Guide RIGOL
4
Product Overview
This rack mount kit (RM1011 & RM1012) is designed to mount RIGOL DS8000-R series
digital oscilloscope into a 19-inch cabinet that conforms to the Electronic Industries
Association (EIA) standard. RM1011 is designed for installing a single instrument, and
RM1012 for two instruments.
Note: Do not keep the air intake areas at the right side of the DS8000-R series digital
oscilloscope far away from heat sources.
Rack Mount Installation for a Single Instrument
(Recommended)
Kit Part Checklist
Table 1 RM1011 Part List
No. Name Qty. Description
1 Front Bezel 1 --
2 Rear Bezel 1 --
3 Rear Hanging Ear 1 --
4 Left Side Beam 1 --
5 Right Side Beam 1 --
6 M4 Screw 8 M4x8 Phillips Pan Head Screw
7 M6 Screw 8 M6x16 Phillips Pan Head Screw
8 M6 Nut 8 M6 Square Lock Cage Nut
Table 2 DS8000-R Components (available to be disassembled for rack mount installation)
No. Name Qty. Description
9 Hanging Ear 1 --
10 Handle 1 --
11 M3 Screw 7 M3x6 Torx Flat Head Countersunk Screw
12 M4 Screw 2 M4x8 Torx Pan Head Screw

Installation Guide RIGOL
5
4
3
5
7
6
2
8
1
10
9
12
11 12 6 7 8
Installation Tool
The PH2 Phillips screwdriver, T10 torx screwdriver, and T20 torx screwdriver are
recommended.

Installation Guide RIGOL
6
Space Requirements
To mount the instrument into the cabinet correctly, please ensure that the following
requirements are met.
The cabinet must be a standard 19-inch one.
The available height of the cabinet should be at least 1U (44 mm).
The depth of the cabinet should be at least 600 mm.
The dimensions of the rack are as shown below.
465
44
483
32
577
569
Unit: mm

Installation Guide RIGOL
7
Installation Procedures
CAUTION
Only authorized operators are allowed to perform the installation. Improper
installation might cause damage to the instrument or an installation failure.
1. Remove the four pads.
2. Remove three M3x6 torx flat head countersunk screws that secure the hanging ear of
the instrument at the right side of the front panel. Then remove two M4x8 torx pan
head screws that secure the handle. You only need to remove the hanging ear at one
side and keep the hanging ear at the other side unremoved.

Installation Guide RIGOL
8
3. Use two M4x8 torx pan head screws to fasten the handle to the front bezel.
4. Attach the front bezel to the right side of the front panel, then secure the bezel by using
three M3x6 torx flat head countersunk screws.
5. Secure the left and right side beams to the two sides of the rear panel by using the
available M3x6 torx flat head countersunk screws on the instrument.

Installation Guide RIGOL
9
6. Mount the assembled instrument and rack into a standard 19-inch cabinet by using four
M6x16 phillips pan head screws and four M6 square lock cage nuts.
7. Use two M6x16 phillips pan head screws and two M6 square lock cage nuts to secure
the rear hanging ear to the cabinet. Then use four M4x8 phillips pan head screws to
secure the left side beam to the rear hanging ear.

Installation Guide RIGOL
10
8. Use two M6x16 phillips pan head screws and two M6 square lock cage nuts to secure
the rear bezel to the rack. Then use four M4x8 phillips pan head screws to secure the
right side beam to the rear bezel.
9. The following figure shows the front view of the successful rack mount installation for
one instrument.
-End-

Installation Guide RIGOL
11
Rack Mount Installation for Two Instruments
Kit Part Checklist
Table 3 RM1012 Part List
No. Name Qty. Description
1 Rear Hanging Ear 2 --
2 Left Side Beam 1 --
3 Right Side Beam 1 --
4 Connecting Plate 4 --
5 M4 Screw 8 M4x8 Phillips Pan Head Screw
6 M6 Screw 8 M6x16 Phillips Pan Head Screw
7 M6 Nut 8 M6 Square Lock Cage Nut
Table 4 DS8000-R Components (available to be disassembled for rack mount installation)
No. Name Qty. Description
8 Hanging Ear 2 --
9 Handle 2 --
10 M3 Screw 18 M3x6 Torx Flat Head Countersunk Screw

Installation Guide RIGOL
12
2
6
4
5
1
3
8
8
7
9
10
10 5 6 7
Installation Tool
The PH2 Phillips screwdriver and T10 torx screwdriver are recommended.

Installation Guide RIGOL
13
Space Requirements
To mount the instrument into the cabinet correctly, please ensure that the following
requirements are met.
The cabinet must be a standard 19-inch one.
The available height of the cabinet should be at least 1U (44 mm).
The depth of the cabinet should be at least 600 mm.
The dimensions of the rack are as shown below.
483
465
32
44
569
577
Unit: mm

Installation Guide RIGOL
14
Installation Procedures
CAUTION
Only authorized operators are allowed to perform the installation. Improper
installation might cause damage to the instrument or an installation failure.
1. Remove the four pads.
2. Remove six M3x6 torx flat head countersunk screws that secure the two hanging ears
at a different side of each instrument. You only need to remove the hanging ear at one
side for each instrument and keep the hanging ear at the other side unremoved.

Installation Guide RIGOL
15
3. Using four connecting plates to fasten the two instruments with eight existing M3x6
torx flat head countersunk screws on the instrument.
4. Secure the left side beam to the left side of the rear panel of Instrument A; and secure
the right side beam to the right side of the rear panel of Instrument B by using the
existing M3x6 torx flat head countersunk screws on the instrument.
Instrument A
Instrument B

Installation Guide RIGOL
16
5. Mount the assembled instrument and rack into a standard 19-inch cabinet by using four
M6x16 phillips pan head screws and four M6 square lock cage nuts.
6. Use four M6x16 phillips pan head screws and four M6 square lock cage nuts to secure
the two rear hanging ears to the rack. Then use four M4x8 phillips pan head screws to
secure the left side beam of Instrument A to the rear hanging ear; use four M4x8
phillips pan head screws to secure the right side beam of Instrument B to another rear
hanging ear.

Installation Guide RIGOL
17
7. The following figure shows the front view of the successful rack mount installation for
two instruments.
-End-
Instrument B
Instrument A

Installation Guide RIGOL
18
Usage Requirement for Rack Mount Installation
into the Cabinet
Working Environment
Temperature
Operating: -40℃ to +30℃
Non-operating: -50℃ to +70℃
Humidity
Operating:
Below +30℃: ≤90%RH (without condensation)
+30℃ to +40℃: ≤75%RH (without condensation)
+40℃ to +50℃: ≤45%RH (without condensation)
Non-operating:
Below 65℃: ≤90% RH (without condensation)
Ventilation Requirement
This oscilloscope uses a fan to force cooling. Please make sure that the air intake and
exhaust areas are free from obstructions and have free air. When using it in rack setting,
keep at least 1 m clearance from the surroundings of the cabinet. When running in the
cabinet, keep it run in the room temperature at 30°C.

Installation Guide RIGOL
19
Cabinet Diagram
This manual suits for next models
1
Table of contents
Other Rigol Rack & Stand manuals

Rigol
Rigol RM-DSA800 User manual

Rigol
Rigol RM-2-DP700 User manual

Rigol
Rigol DSA800-RMSA User manual

Rigol
Rigol RM-3-DP700 User manual

Rigol
Rigol MSO5000 Series User manual

Rigol
Rigol DG10X1 Series User manual

Rigol
Rigol RM-DM-3 User manual

Rigol
Rigol MSO4000 Series User manual

Rigol
Rigol DP1308A User manual

Rigol
Rigol DP800 Series User manual
Popular Rack & Stand manuals by other brands

Rite Mounts
Rite Mounts PFM Series installation instructions

Precor
Precor Vitality OPT6820 Maintenance Guide

Global
Global WB436945ABG Assembly instructions

Magnavox
Magnavox M-T00521 owner's manual

Display Mount Pro
Display Mount Pro MDM 003T Installation instruction

NexxTech
NexxTech 47-84” Tilt Large TV Mount installation guide