RKI Instruments 82-5202 Series User manual

2• 82-5202-XX Email/Text Generator Operator’s Manual
Product Warranty
RKI Instruments, Inc. warrants gas alarm equipment sold by us to be free from defects in
materials, workmanship, and performance for a period of one year from date of shipment from
RKI Instruments, Inc. Any parts found defective within that period will be repaired or replaced, at
our option, free of charge. This warranty does not apply to those items which by their nature are
subject to deterioration or consumption in normal service, and which must be cleaned, repaired, or
replaced on a routine basis. Examples of such items are:
• Absorbent cartridges
•Fuses
• Pump diaphragms and valves
•Batteries
• Filter elements
Warranty is voided by abuse including mechanical damage, alteration, rough handling, or repair
procedures not in accordance with the operator’s manual. This warranty indicates the full extent
of our liability, and we are not responsible for removal or replacement costs, local repair costs,
transportation costs, or contingent expenses incurred without our prior approval.
THIS WARRANTY IS EXPRESSLY IN LIEU OF ANY AND ALL OTHER WARRANTIES AND
REPRESENTATIONS, EXPRESSED OR IMPLIED, AND ALL OTHER OBLIGATIONS OR
LIABILITIES ON THE PART OF RKI INSTRUMENTS, INC. INCLUDING BUT NOT LIMITED TO,
THE WARRANTY OF MERCHANTABILITY OR FITNESS FOR APARTICULAR PURPOSE. INNO
EVENT SHALL RKI INSTRUMENTS, INC. BE LIABLE FOR INDIRECT, INCIDENTAL, OR
CONSEQUENTIAL LOSS OR DAMAGE OF ANY KIND CONNECTED WITH THE USE OF ITS
PRODUCTS OR FAILURE OF ITS PRODUCTS TO FUNCTION OR OPERATE PROPERLY.
This warranty covers instruments and parts sold to users by authorized distributors, dealers, and
representatives as appointed by RKI Instruments, Inc.
We do not assume indemnification for any accident or damage caused by the operation of this gas
monitor, and our warranty is limited to the replacement of parts or our complete goods.

82-5202-XX Email/Text Generator Operator’s Manual • 3
Table of Contents
Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Initial Setup. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Accessing the Generator’s Cloud Account . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Website Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Updating Device Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Generator Settings. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Setting Up Email and Text Notifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Saving Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Alarm Logs View . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Parts List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20

4• Overview 82-5202-XX Email/Text Generator Operator’s Manual
Overview
The 82-5202-XX email/text generator is capable of monitoring up to 2 sets of contacts and
sending out an email and/or text message due to the following events:
• a monitored contact opens or closes
• the generator is powered on
• the generator loses connection to power or WiFi network
One or two email.text generator modules are installed in a plastic housing that has a conduit hub
on the bottom. An AC power supply is installed to the left of the email/text generator(s). The
power supply’s AC input terminals are wired to a terminal strip at the bottom of the mounting
plate to make it easy to connect power at the installation site.
Figure 1: Component Location (82-5202-02 Email/Text Generator Shown)
NEMA 4X
housing
AC Terminal
Strip
Conduit Hub
Power
Supply
Email/Text
Generator
Module (2x)

82-5202-XX Email/Text Generator Operator’s Manual Specifications • 5
Specifications
Input Power 110 - 240 VAC, 50/60 Hz
Current Draw 200 mA max (per email/text generator module)
WiFi 2.4 GHz
NOTE: The 82-5202-XX email/text generator does not support 5 GHz networks,
captive portal networks.
Contacts 1 or 2 input contact ports (depending on the version ordered)
LED and Buzzer
Indicators
LED Flashing Amber and
Buzzer Emitting a Long Beep
(after the side button has been
held for at least 5 seconds)
The email/text generator module has entered ini-
tial setup mode.
LED Flashing Amber (upon
startup)
The module is trying to connect to a WiFi net-
work but either has not been set up or cannot
find the assigned WiFi.
LED Solid Green The module is on and functioning properly.
LED Solid Amber The contact terminal strip has been disconnected
from the module.

6• Installation 82-5202-XX Email/Text Generator Operator’s Manual
Installation
1. Select the mounting site. When you select the mounting site consider the following factors:
• Is an AC power source available?
• Is there enough room to open the housing door and make wiring connections (see Figure
2)?
2. The mounting feet and hardware to install the mounting feet are shipped in a bag inside the
housing. Install the mounting feet as shown below.
3. Position the monitor on a vertical surface at eye level (4 1/2 to 5 feet from the floor).
4. Use 3/16” screws through the slots in the mounting feet at each corner of the housing to secure
the housing to the mounting surface.
5. The contact terminal strip(s) and email/text generator module(s) are shipped uninstalled and
stored in the enclosure. Plug the email/text generator module(s) into the USB port standoff(s).
NOTE: Leave the contact terminal strip(s) uninstalled until the relay contacts have
been connected.

82-5202-XX Email/Text Generator Operator’s Manual Installation • 7
Figure 2: Dimensions
Ø0.21x0.33slot,4X
10.439.33
5.20
5.98

8• Wiring 82-5202-XX Email/Text Generator Operator’s Manual
Wiring
1. Unscrew and remove the kep nuts from the AC terminal strip’s cover.
2. Route the AC wires through the conduit hub on the bottom of the housing.
3. Connect a line wire from the AC power source to the “H” terminal on the AC terminal strip.
4. Connect a neutral wire from the AC power source to the “N” terminal on the AC terminal
strip.
5. Connect a ground wire from the AC power source to the “G” terminal on the AC terminal
strip.
6. Reinstall the AC terminal strip’s cover using the kep nuts.
Figure 3: AC Wiring
L GN
AC Power
Source

82-5202-XX Email/Text Generator Operator’s Manual Wiring • 9
7. To wire the relay contacts, remove the contact-monitoring terminal(s) from the email/text
generator module(s) if plugged in.
8. Connect the two wires to the terminal strip as follows (see Figure 4).
a. Connect the common wire to the ground (bottom) terminal.
b. Connect the relay contact wire (normally opened or normally closed) to the “L” terminal.
NOTE: Disregard the middle terminal labeled “R”. The monitoring terminals
function only as contact monitors and are not used to power any components.
9. Plug the contact-monitoring terminal(s) into the email generator module(s).
10. For 82-5202-02 generators, repeat Step 7 through Step 9 to wire and install the second
contact-monitoring terminal strip.
11. Plug in power to the email/text generator.
Figure 4: Contact Wiring
L
G
R
Common
Monitoring
Contacts
Relay Contacts
Common
NO or NC
R
L
G
NO or NC

10 • Initial Setup 82-5202-XX Email/Text Generator Operator’s Manual
Initial Setup
NOTE: If there are any errors or blank fields in a submitted form, the generator module(s) must
be reset by holding down the button below the terminals. Always check that information
is entered correctly before submitting forms.
1. Connect power to the email/text generator. The LED will light up green.
2. Press and hold the reset button on the left side of the generator module below the terminals.
Release the button when the LED begins flashing orange and a long beep sounds.
The email/text generator module is now ready for setup.
3. Navigate to the WiFi Networks screen on your computer, phone, or tablet.
NOTE: Android phones must be in airplane mode before connecting to the email/
text generator. If connectivity issues occur with another mobile device,
tablet, or computer, place it into airplane mode.
4. Select ProteusSetup-XXXXXXXXX. The 9-digit string will be unique to the generator
module.

82-5202-XX Email/Text Generator Operator’s Manual Initial Setup • 11
5. After selecting the generator module’s network, the setup interface automatically opens up in
a browser window. Allow the page to scan for WiFi networks.
6. Select the WiFi network that the generator will connect to.
7. Enter the WiFi password (case-sensitive) into the text field.
8. Press “OK” to connect the generator to the selected WiFi network.

12 • Initial Setup 82-5202-XX Email/Text Generator Operator’s Manual
9. Select the time-zone and enter the primary email address.
NOTE: This email address will also be registered as the account’s username. To add
more email addresses for receiving alerts, press the “+” icon.
10. Press “SAVE SETTINGS” to submit all information entered. Allow 30 seconds for initial
setup to complete.

82-5202-XX Email/Text Generator Operator’s Manual Initial Setup • 13
11. If the setup is successful, the buzzer will emit a long beep.
If the setup is unsuccessful, the buzzer will emit three short beeps and the LED will flash
orange. See “Troubleshooting” on page 20 for further instructions.
12. After successfully connecting the generator, a confirmation email is sent to the primary email
address entered in Step 9.
Figure 5: Confirmation Email
13. Click “Set Password for cloud login” and proceed to the next section.
14. For 82-5202-02 generators, repeat this procedure to set up the second email/text generator
module.
Accessing the Generator’s Cloud Account
Access to the generator’s cloud account is required for updating contact info (email addresses and
phone numbers), reviewing and downloading alarm logs, and configuring generator and alarm
settings.
NOTE: If a generator is set up with the same primary email address used for an existing cloud
account, the generator will automatically connect to that account. The following
procedure does not need to be performed for each generator’s setup.
1. Open the confirmation email sent to the primary email account submitted in Step 9.
2. Click on “Set Password for cloud login”, or paste the provided URL into the browser search
bar and press enter. Refer to Figure 5.
3. On the registration page, enter the primary email address as the username.
4. Enter a password, then click “Sign Up”. The generator’s website interface is now available.

14 • Website Interface 82-5202-XX Email/Text Generator Operator’s Manual
Website Interface
After the generator and cloud account have been set up, enter cloud.proteussensor.com/ into a
computer, tablet, or mobile phone browser and log into the website interface.
1. Sensor List Item: The Home menu lists sensors connected to the logged-in profile. Each item
lists the sensor’s name, the most recent event, and the last time the sensor sent an update.
2. Profile: Opens a dropdown menu for viewing profile settings, terms of use, and logging out.
3. Share/Add Icons:
a. The blue arrow opens a window with a shareable link to a read-only version of the
generator’s main interface (not including the alarm logs or settings views). Links already
in use can also be deactivated.
b. The green “+” symbol icon navigates to the generator’s online store.
4. View Selection:
a. The bell icon opens the alarm logs view that shows all recorded activity.
b. The gear icon opens the generator’s settings view. For the list of available settings, see
Table 1 on page 16.
5. Alert Switch: This switch controls whether a message will be sent when a generator’s alarm is
triggered.
5
14
3
2

82-5202-XX Email/Text Generator Operator’s Manual Updating Device Settings • 15
Updating Device Settings
The Settings view displays notification settings, contact and power settings, and spaces for
entering and updating contact information.
Overview
1. MAC/IP Addresses: Displays the generator’s MAC and IP addresses
2. Rewind Icon: Opens the Settings change history
3. Refresh Icon: Refreshes the Settings page with any recent events logged by the generator
4. Home Icon: Returns to the website’s main interface
5. Double Arrow Icon: Shows the next generator’s settings
6. Bell Icon: Opens the alarm logs view that shows all recorded activity
2
3
5
1
46

16 • Updating Device Settings 82-5202-XX Email/Text Generator Operator’s Manual
Generator Settings
The following table is a summary of user-adjustable options found on the Settings page:
NOTE: Changing settings or contact information of one generator does not automatically
change the settings of another generator. To duplicate preferred settings, each generator
must be adjusted individually.
Table 1: Settings View Options
Sensor Power &
Relay Settings
Switch Sensor • Normally Closed (alarm triggered when contacts open)
• Normally Open (alarm triggered when contacts close)
Sensor On/Off On or Off
Schedule
Settings
•Always
• As Scheduled
If set to As Scheduled, the device can be configured to send
alerts on certain days and within specific time windows.
Two start/end periods can be saved per email/text generator
(24-hour format).
Set Custom
Messages
The text of the alarm message and reset message can be edited using these fields.
Alarm Delays
(optional)
• delay (value in seconds) between an alarm triggered and an alert being sent
• delay (value in seconds) between an alarm reset and an alert being sent
Buzzer • Enabled or Disabled
• Snooze alarm after a period of time (value in minutes)
Time Zone The generator’s time zone can be adjusted.
Notifications
Email/Text
Notifications
•Onor Off
• Text field for email and/or phone contacts
Resend Alerts Period between resending alerts (value in minutes)
Alarm Reset
Notification
•Onor Off
• Sends notifications after an alarm is reset
Power/WiFi
Outage Notifica-
tion
• Sends a notification if a power/WiFi outage lasts more than
a set period of time (value in minutes)
•Optional: Text field for email and/or phone contacts that
will receive notifications during power/WiFi outages
NOTE: If this text field is left blank, the generator will only
send power/WiFi notifications to the primary email
associated with the generator’s account.
To prevent all power/WiFi notifications from being sent, enter
“skip” into the text field.

82-5202-XX Email/Text Generator Operator’s Manual Updating Device Settings • 17
Setting Up Email and Text Notifications
To activate text notifications, log into the generator’s website interface using the following link:
cloud.proteussensor.com/.
1. While viewing the Home screen, press “Settings” or the gear icon.
2. While in the Settings View, scroll down to the “Notifications” section of the page.
3. Click on the text field with the contact addresses listed.
4. Enter a comma after the last contact address and enter the phone number(s). Do not add any
spaces between email addresses or phone numbers.
For phone numbers, a XXXXXXXXXX@______ format is required, where the domain
name used in the blank field depends on the phone number’s wireless carrier. Refer to the
following figure and table for formatting and domain names.
Wireless Carrier Domain Name
AT&T txt.att.net (SMS)
OR
mms.att.net (MMS)
Boost Mobile sms.myboostmobile.com (SMS)
OR
myboostmobile.com (MMS)
Cricket sms.cricketwireless.net (SMS)
OR
mms.cricketwireless.net (MMS)

18 • Updating Device Settings 82-5202-XX Email/Text Generator Operator’s Manual
Saving Settings
When finished viewing or adjusting the device’s settings, press the “Save Settings” button at the
bottom of the screen.
Google Fi msg.fi.google.com (SMS & MMS)
Metro PCS mymetropcs.com (SMS & MMS)
Sprint messaging.sprintpcs.com (SMS)
OR
pm.sprint.com (MMS)
T-Mobile tmomail.net (SMS & MMS)
Tracfone mmst5.tracfone.com (MMS)
U.S. Cellular email.uscc.net (SMS)
OR
mms.uscc.net (MMS)
Verizon vtext.com (SMS)
OR
vmpix.com (MMS)
Virgin Mobile vmobl.com (SMS)
OR
vmpix.com (MMS)
Xfinity Mobile vtext.com (SMS)
OR
mypixmessages.com (MMS)
Wireless Carrier Domain Name

82-5202-XX Email/Text Generator Operator’s Manual Alarm Logs View • 19
Alarm Logs View
The Alarm Logs view shows all contact and status changes since the generator’s initial setup.
The screenshots in the following figure are from the desktop version of the website interface to
clearly display the Logs table and the Download Alarm Logs feature.
1. Download Alarm Logs: Downloads a .csv file of the generator’s alarm logs from one of the
following periods: 1 day ago, 7 days ago, or 30 days ago
2. Refresh Icon: Refreshes the Alarm Logs page with any recent events logged by the generator
3. Home Icon: Returns to the website’s main interface
4. Double Arrow Icon: Shows the next generator’s alarm logs.
5. Trash Can Icon: Deletes all alarm logs saved since the generator’s initial setup
1
2
3
4
5
6

20 • Troubleshooting 82-5202-XX Email/Text Generator Operator’s Manual
6. Settings (Gear Icon): The gear icon opens the generator’s settings view. For the list of
available settings, see Table 1 on page 16.
Troubleshooting
Parts List
Problem Solutions
Unable to access web
interface
• Press and hold the reset button until the LED flashes orange
and the buzzer sounds for 10 seconds, then reconnect to the
generator’s network ID.
• Try using a different computer, phone, or tablet.
Won’t connect to the
WiFi network
• LED flashes orange
three times
• Buzzer beeps 3 times
• Ensure the network you are trying to connect to is a 2.4 GHz
network. The device does not support 5 GHz networks.
• Place the mobile device, tablet, or computer into airplane
mode. Android phones must be in airplane mode before the
generator can be setup.
• Move the device to within 10 feet of the router/access point
and try again.
Email/text sent but not
received
• Ensure the email is not caught by the spam filter or junk
filter.
• If an Outlook account is being used, check the account’s
inbox for the account verification email from Outlook.
Follow the email’s steps on verification.
Part Number Description
82-5202P Replacement email/text generator module
This manual suits for next models
1
Table of contents
Popular Portable Generator manuals by other brands

Generac Power Systems
Generac Power Systems XP4000 Professional specification

NDS
NDS POWERSERVICE PLUS 25 user manual

Homelite
Homelite HGCA1400 Series Replacement parts list

Mecc Alte
Mecc Alte ECO 28 S Operating and maintenance instructions

Powermate
Powermate PM0143400 Operator's manual

Husky
Husky HU3650 Operator's manual