RND 355-00003 User manual

USER MANUAL – BEDIENUNGSANLEITUNG – ANVÄNDARMANUAL
RND 355-00003
True RMS Multimeter | EN p2 | DE p25 | SE p48

2
English
Read First
Safety Informaon
Understand and follow operang instrucons carefully. Use the meter only as specied
in this manual; otherwise, the protecon provided by the meter may be impaired.
WARNING
Idenes hazardous condions and acons that could cause BODILY HARM or DEATH.
CAUTION
Idenes condions and acons that could DAMAGE the meter or equipment under test
WARNING
• When using test leads or probes, keep your ngers behind the nger guards.
• Remove test lead from Meter before opening the baery door or meter case.
• Use the Meter only as specied in this manual or the protecon by the Meter might be
impaired.
• Always use proper terminals, switch posion, and range for measurements.
• Verify the Meter’s operaon by measuring a known voltage. If in doubt, have the Meter
serviced.
• Do not apply more than the rated voltage, as marked on Meter, between terminals or
between any terminal and earth ground.
• Only replace the blown fuse with the proper rang as specied in this manual.
• Use cauon with voltages above 30 Vac rms, 42 Vac peak, or 60 Vdc. These voltages pose
a shock hazard.
• To avoid false readings that can lead to electric shock and injury, replace baery as soon
as low baery indicator.
• Disconnect circuit power and discharge all high-voltage capacitors
before tesng resistance, connuity, diodes, or capacitance.
• Do not use Meter around explosive gas or vapor.
• To reduce the risk of re or electric shock do not expose this product to rain or moisture.

3
Symbols as marked on the Meter
and Instruction manual
Risk of electric shock
See instrucon manual
DC measurement
Equipment protected by double or reinforced insulaon
Baery
Fuse
Earth
AC measurement
Conforms to EU direcves
Do not discard this product or throw away.
Unsafe Voltage
To alert you to the presence of a potenally hazardous voltage, when the Tester detects a
voltage 30 V or a voltage overload (OL) in V, mV, AutoV . The symbol is displayed.
Maintenance
Do not aempt to repair this Meter. It contains no userserviceable parts. Repair or servicing
should only be performed by qualied personnel.
Cleaning
Periodically wipe the case with a dry cloth and detergent. Do not use abrasives or solvents.
•Disconnect circuit power and discharge all high-voltage capacitors before tesng
resistance, connuity, diodes, or capacitance.
•Do not use Meter around explosive gas or vapor.
•To reduce the risk of re or electric shock do not expose this product to rain or moisture.
•Disconnect the test leads from the test points before changing the posion of the
funcon rotary switch.
•Do not expose Meter to extremes in temperature or high humidity.
•Never set the meter in A funcon to measure the voltage of a power supply
circuit in equipment that could result in damage the meter and the equipment under test.
CAUTION

4
Introduction
The Meter Description
Front Panel Illustraon
1. VoltSeek Light
2. 6,000 counts digital and 60 segments analog display
3. Push-buons.
4. Rotary switch for turn the Power On / O and select the funcon.
5. Input Terminal for Multi-function.
6. Common (Ground reference) Input Terminal.
1. VoltSeek Light
2. LCD Display
3. Buon
4. Rotary switch
6. Common input
5. V, Ω, , Input (Or "+")

5
Features:
•6,000 count digital and 60 segments analog display
•Large white LED backlight display
•True RMS measurements on ACV
•LoZ for prevent false reading from ghost voltage
•AutoVolt automac AC/DC voltage selecon
•Auto Ranging
•0.5% DCV accuracy
•Smart Hold
•Peak Hold for capture peak readings
•Relave Funcon
•Auto Power O (can be disabled)
•Capacitance measurements
•Frequency Counter on ACV
•Diode Test
•°C/°F Temperature Funcon
•AC/DC μA Funcon
•Temperature Probe included
•VoltSeekTM for non-contact voltage detecon
•EasySckTM holster with built in magnec scker
•ConVisionTM for visible connuity beeper
•Baery Capacity indicaon in segments
•Included Holster with Probe Holder, Tilt Stand and Magnec scker
•˙CAT IV 600V/ CATIII 1000V standard

6
Making Basic Measurements
Measuring ACV/DCV/AutoV Voltage
Dial the switch to select the measuring funcon
Preparaon and Cauon Before Measurement
: Observe the rules of Warnings and Cauons
CAUTION
When connecng the test leads to the DUT (Device Under Test) connect the common test
leads before connecng the live test leads ; when removing the test leads, remove the live
test leads before removing the common test leads.

7
Measuring AC/DC μA
Dial the switch and press the Funcon buon to select the measuring funcon

8
Measuring Capacitance / Diode
Dial the switch and press the Funcon buon to select the measuring funcon

9
Measuring Continuity / Resistance
Dial the switch and press the Funcon buon to select the measuring funcon.
Red Black

10
Measuring Temperature °C / °F
Dial the switch and press the Funcon buon to select the measuring funcon. (°C / °F)
Press

11
VoltSeek
Dial the switch and press the RANGE buon to select the measuring funcon and
sensivity.
The VoltSeek LED indicates the electric eld. If the VoltSeek LED is not on, voltage could sll
be present.
WARNING

12
Using the Function
Range Buon
Press the Funcon buon to change the funcon on the same switch posion.
Switch
Position Function

13
Peak Hold (for AC only)
In the Peak Hold funcon ,the meter records the peak min. value and the peak max. value
when the inputs goes below the recorded peak min. value or above the recorded peak max.
value ,the meter records the new value. Press Hold buon to pause the recording.

14
Smart Hold
RelativeΔ
The meter will beep connuously and the display will ash if the measured signal is larger
than the display reading by 50 counts. (However ,it cannot detect across the AC and DC
Voltage / Current).
Press the Relave buon to enable/disenable this funcon.

15
Backlight
Auto Power O
Press the Backlight buon to turn the backlight on/o.
Wake-up the meter by dialing the switch or pressing any buon.

16
Disable Auto Power O
Testing LCD Monitor
Dial the switch to o posion ,then keep the Funcon buon down
and turn the meter on.
Dial the switch to o posion ,then keep the HOLD buon down
and turn the meter on.

17
Default Temperature Units

18
Low Baery and Baery Replacement
Replace the baery as soon as the low baery indicator appears, to avoid false reading.
Refer to the following gure to replace the baeries
Remove test leads from meter before opening the baery cover or meter case.
CAUTION

19
Specications
General Specications
Maximum voltage applied to any terminal:
1000 Vac rms or 1000 Vdc. rms
Display : 6000 counts.
Polarity Indicaon : Automac, posive implied, negave indicated.
Overrange Indicaon : OL
Baeries Life : 200 hours ALKALINE Baery
Low Baeries Indicaon : Voltage drops below operang voltage will ash.
Power Requirement : 9V baery
Auto Power O : 20 minutes.
Operang Temperature : -10 ~10°C
10°C ~ 30°C (<80% RH),
30°C ~ 40°C (<75% RH),
40°C ~ 50°C (<45%RH)
Storage Temperature :
-40°C to 60°C , 0 to 80% R.H. (baeries not ed)
Measure : Samples 3 mes per second.
Altude : 6561.7 (2000m)
Weight : 250g (including baery)
Dimensions (W x H x D) : 74mm x 156mm x 44mm.
I The circuits not connected to mains.
II The circuits directly connected to Low-voltage installaon.
III The building installaon.
IV The source of the Low-voltage installaon.
CAT Applicaon eld

20
Polluon degree : 2
Safety : Complies with EN61010-1,CAT.IV. 600V, CAT|||. 1000V
EMC : EN 61326-1
Shock vibraon : Sinusoidal vibraon per MIL-PRF- 28800F (5 ~ 55 Hz, 3g max.)
Drop Protecon : 4 feet drop to hardwood on concrete oor.
Indoor Use.
Electrical Specications
Accuracy is given as ±(% of reading + counts of least signicant digit) at 23°C ± 5°C, with
relave humidity Less than 80% R.H.
1. Temperature coecient
0.1 x (Specied accuracy) / °C, < 18°C, > 28°C
2. AC Funcon
ACV and ACA specicaons are ac coupled, true R.M.S. The crest factor may be up to
3.0 as 4000 counts. For square wave, Accuracy is unspecied.
For non-sinusoidal waveforms, Addional Accuracy by Cres Factor (C.F.):
Add 3.0% for C.F. 1.0 ~ 2.0.
Add 5.0% for C.F. 2.0 ~ 2.5.
Add 7.0% for C.F. 2.5 ~ 3.0.
3. DC mV
Input Impedance : 10MΩ
Overload Protecon : AC/DC1000V
Range OL Reading Resoluon Accuracy
600.0mV 660.0mV 0.1mV ±(0.5% + 5D)