Robe RoboSpot User manual

1
Version 1.1

2
Table of contents
1. Safety instructions ......................................................................................................... 3
2. Fixture exterior view ...................................................................................................... 5
3. Installation....................................................................................................................... 6
3.1 Connection to the mains ............................................................................................ 6
3.2 Rigging the xture ...................................................................................................... 6
3.3 DMX-512 connection.................................................................................................. 8
3.4. Wireless DMX operation ........................................................................................... 8
4. Control menu map.......................................................................................................... 9
5. Control menu ............................................................................................................... 10
5.1 Addressing (DMXA).................................................................................................. 10
5.2 Fixture information (Info) .......................................................................................... 10
5.3 Personality (Pers)..................................................................................................... 10
5.4 Manual Control (Manual).......................................................................................... 11
5.5 Reset........................................................................................................................ 11
5.6 Special functions (Special)....................................................................................... 11
6.
Operation of the RoboSpot MotionCamera with the RoboSpot ............................. 13
6.1 RoboSpot connection............................................................................................... 13
6.2 LCD monitor screen operation ................................................................................. 13
7. RDM ............................................................................................................................... 16
8. Error and information messages ................................................................................ 16
9. Technical Specications.............................................................................................. 17
10. Maintenance and cleaning......................................................................................... 19
10.1 Replacing the fuse ................................................................................................. 20
10.2 Disposing of the product ........................................................................................ 21
RoboSpot MotionCamera

3
FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL CAREFULLY
BEFORE POWERING OR INSTALLING YOUR RoboSpot MotionCamera !
Save it for future reference.
This device has left our premises in absolutely perfect condition. In order to maintain this condition and to en-
sure a safe operation, it is absolutely necessary for the user to follow the safety instructions and warning notes
written in this manual.
The manufacturer will not accept liability for any resulting damages caused by the non-observance of this
manual or any unauthorized modication to the device.
Please consider that damages caused by manual modications to the device are not subject to warranty.
The RoboSpot MotionCamera was designed for indoor use and it is intended for
professional application only. It is not for household use.
1. Safety instructions
DANGEROUS VOLTAGE CONSTITUTING A RISK OF ELECTRIC SHOCK IS PRESENT WITHIN THIS UNIT!
Make sure that the available voltage is not higher than stated on the rear panel of the xture.
This xture should be operated only from the type of power source indicated on the marking label. If you are
not sure of the type of power supplied, consult your authorized distributor or local power company.
WARNING! This unit does not contain an ON/OFF switch. Always disconnect power input cable
to completely remove power from unit when not in use or before cleaning or servicing the unit.
Do not allow anything to rest on the power cord. Do not locate this xture where the cord may be damaged by
persons walking on it.
Make sure that the power cord is never crimped or damaged by sharp edges. Check the xture and the power
cord from time to time.
Refer servicing to qualied service personnel.
This xture falls under protection class I. Therefore this xture has to be connected to
a mains socket outlet with a protective earthing connection.
Do not connect this xture to a dimmer pack.
If the xture has been exposed to drastic temperature uctuation (e.g. after transportation), do not switch it on
immediately. The arising condensation water might damage your device. Leave the device switched o until
it has reached room temperature.
Avoid brute force when installing or operating the xture.
This xture was designed for indoor use only, do not expose this unit to rain or use near water.
When choosing the installation spot, please make sure that the xture is not exposed to extreme heat, moisture
or dust.
Air vents and slots in the xture´s head and base are provided for ventilation, to ensure reliable operation of
the device and to protect it from overheating.

4
This xture should not be placed in a built-in installation unless proper ventilation is provided.
Only operate the xture after having checked that the housing is rmly closed and all screws are tightly fastened.
Always use a secondary safety cable when rigging this xture.
Make sure that the area below the installation place is blocked when rigging, de-rigging or servicing the xture.
Operate the xture only after having familiarized with its functions. Do not permit operation by persons not
qualied for operating the xture. Most damages are the result of unprofessional operation!
Please use the original packaging if the xture is to be transported.
Please consider that unauthorized modications on the xture are forbidden due to safety reasons!
If this device will be operated in any way dierent to the one described in this manual, the product may suer
damages and the guarantee becomes void. Furthermore, any other operation may lead to dangers like short-cir-
cuit, burns, electric shock, crash etc.
To avoid damage of the internal optical system of the camera, never let the sunlight or
other xture lights directly to the camera lens , even when the xture is not working !

5
2. Fixture exterior view
1 - Camera lens
2- Moving head
3- Yoke
4 - Base
5 - DMX Out (5-pin XLR)
6 - DMX In (5-pin XLR)
7 - Camera output (RJ45)
8 - Control board
9 - Mains In
10 - Mains Out

6
3. Installation
Fixtures must be installed by a qualied electrician in accordance with all
national and local electrical and construction codes and regulations.
3.1 Connection to the mains
For protection from electric shock, the xture must be earthed!
The RoboSpot MotionCamera is equipped with auto-switching power supply that automatically adjusts to any
50-60Hz AC power source from 100-240 Volts.
If you need to install a cord cap on the power cable to allow connection to power outlets, install a grounding-type
(earthed) plug, following the plug manufacturer’s instructions.
If you have any doubts about proper installation, consult a qualied electrician.
Core (EU) Core (US) Connection Plug Terminal Marking
Brown Black Live L
Light blue White Neutral N
Yellow/Green Green Earth
This device falls under class one and must be earthed (grounded)!
3.2 Rigging the xture
A structure intended for installation of the xture(s) must safely hold weight of the xture(s) placed on it. The
structure has to be certicated to the purpose.
The xture must be installed in accordance with national and local electrical and construction codes and reg-
ulations.
For overhead installation, the xture must be always secured with a safety wire that
can bear at least 10 times the weight of the xture.
When rigging, de-rigging or servicing the xture staying in the area below the installation place, on bridges,
under high working places and other endangered areas is forbidden.
The operator has to make sure that safety-relating and machine-technical installations are approved by a skilled
person once a year.
The xture should be installed outside areas where persons may walk by or be seated.
IMPORTANT! OVERHEAD RIGGING REQUIRES EXTENSIVE EXPERIENCE, including (but not limited to)
calculating working load limits, installation material being used, and periodic safety inspection of all installation
materials and the xture. If you lack these qualications, do not attempt the installation yourself, but instead use
a professional structural rigger. Improper installation can result in bodily injury or damage to property.
The xture has to be installed out of the reach of people.
The xture must never be xed swinging freely in the room.

7
Caution: Fixture may cause severe injuries when crashing down! If you have doubts concerning the safety of
a possible installation, do not install the moving head!
Before rigging make sure that the installation area can hold a minimum point load of 10 times the xture’s weight.
CAUTION!
Use an appropriate clamp to rig the xture on the truss.
Make sure that the device is xed properly! Ensure that the
structure (truss) to which you are attaching the xture is secure.
The xture can be placed directly on the stage oor or rigged on a truss without altering its operation characte-
ristics.
For securing the xture to the truss install a safety wire that can hold at least 10 times the weight of the xture.
Use only the safety wire with a snap hook with screw lock gate. Fasten the snap hook in the attachment point
and the safety wire around the truss as shown on the picture below.
.
1-Quick-lock fastener
2-Omega holder
3-Trust
4-Clamp
5-Safety wire with a snap hook
with screw lock gate
6-Attachment point
When installing xtures side-by-side, avoid illuminating the xture with another
xture!

8
3.3 DMX-512 connection
The xture is equipped with 5-pin XLR sockets for DMX input and output. Only use a shielded twisted-pair
cable designed for RS-485 and 5-pin XLR-plugs and connectors in order to connect the controller with the
xture or one xture with another.
DMX output DMX input
XLR socket: XLR plug:
If you are using the standard DMX controllers, you can connect the DMX output of the controller directly with the
DMX input of the rst xture in the DMX-chain. If you wish to connect DMX-controllers with other XLR-outputs,
you need to use adapter-cables.
1 - Shield
2 - Signal (-)
3 - Signal (+)
4 - Used for wireless DMX
5 - Used for wireless DMX
1 - Shield
2 - Signal (-)
3 - Signal (+)
4 - Used for wireless DMX
5 - Used for wireless DMX
3.4. Wireless DMX operation
The external Robe Wireless CRMX-LB100 module allows receiving wireless DMX. This module is equipped
with the Lumen Radio CRMX module and antenna for receiving DMX signal. CRMX module operates on the
2.4 GHz band.
Push in the 5-pin XLR plug (1) into 5-pin XLR sockit (4) and simultaneously locating pin (2) into hole (5) in the
xture. In this way the wireless DMX module is connected with the xture.
NOTE: when you disconnect the DMX wireless module from xture, press and hold lock (5) during getting the
wireless module out.
To link the xture with DMX transmitter.
The xture can be only linked with the transmitter by running the link procedure at DMX transmitter .
After linking , the level of DMX signal ( 0-100 %) is displayed in the menu item “Stat“ (Special -->Vireless -->Stat).
To unlink the xture from DMX transmitter.
The xture can be unlinked from receiver via the menu item “ Unlink“ (Special-->Vireless -->Unlink).
1 - 5-pin XLR (female)
2 - Locating pin
3 - Lock
Robe Wireless CRMX-LB100

9
4. Control menu map
Default settings=Bold print
Level 1 Level 2 Level 3 Level 4 Level 5 Level 6 Level 7
DMXA Set DMXA 001-255
DMX Pres Mode 1
Info POn Time Total
Reset
DMX In Pan 0-255
:
Reserved
Sw Ver IC-1
IC-2
Pers
DMX Pres Mode 1
Pan Rev On, O
Tilt Rev On, O
P/T Mode Speed
Time
P/T Feed On, O
Display Turn
On/O T On, O
Contrast 0-100%
Backlight 0-100%
Temp Uni °C, °F
I Ef Pos Pan
:
Reserved
Store
Defaults
Manual Pan 0-255
:
Reserved
Reset
Special RDM Low
RDM Hight
Wireless Stat
Unlink
Adjust DMX Val Pan 0-255
:
Reserved
Calib Cal Mech Pan C 0-255
Tilt C 0-255
Store
Cal Load
SW Upd

10
5. Control menu
The RoboSpot MotionCamera is equipped with 2-row LCD display which allows to set the xture´s behaviour
according to your needs and obtain information about its operation.
Control panel:
[ESCAPE] button used to leave the menu without saving changes.
[NEXT] , [PREV] buttons for moving between menu items and for value adjusting.
[ENTER] button used to enter the selected menu (menu item) and to conrm adjusted value.
After switching the xture on, display shows current DMX address.
5.1 Addressing (DMXA)
Set DMXA- Use this menu item to set the DMX start address of the xture, which is dened as the rst channel
from which the RoboSpot MotionCamera will respond to the controller.
If you set, for example, the address 36, the RoboSpot MotionCamera will use channels 36 - 43 for control.
Please, be sure that you do not have any overlapping channels in order to control each RoboSpot MotionCamera
correctly and independently from any other xture on the DMX data link.
If there is no data received at the DMX input, the display will start to ash "0001” with actually stored DMX address.
5.2 Fixture information (Info)
Pon Time - Power on time. Select this menu to read the number of xture operation hours.
Total -
The item shows the total number of the operation hours since
the RoboSpot MotionCamera
has been fabricated.
Reset -
The item shows the number of the operation hours that the
RoboSpot MotionCamera
has been powered on since the counter was last reset.
In order to reset this counter to 0, press and hold both [NEXT] and [PREV] buttons and the
[Enter] button at the same time.
DMX In - DMX readout. The menu is used to read DMX values of each channel received by the xture.
Sw Ver - Software versions. Select this item to read the software version of the xture modules.
IC-1 - A pan/Tilt processor.
IC-2 - A display processor.
5.3 Personality (Pers)
Pan Rev - Pan reverse. The item allows to invert pan movement.
Tilt Rev - Tilt reverse. The item allows to invert tilt movement.
P/T Mode - Pan and Tilt movement mode. Use this menu to set mode of the pan/tilt movement.
Speed - Both Pan and tilt will move with the same speed as adjusted at the channel
"Pan/Tilt speed, Pan/Tilt time".
Time – The pan and tilt will move with dierent speeds and they will come at
the same time to the end point of their tracks (pan and tilt use their optimal speeds).
Time of the pan/tilt movement (25.5 sec. max.) is set by the channel "Pan/Tilt speed, Pan/Tilt
time".

11
P/T Feed - Pan and Tilt Feedback. The menu item allows to return the mowing head to the required pan/tilt
position after changing the position by an external force if this option is set on.
Note. The Pan/Tilt Feedback should be permanent On, the option O is not suitable for standard operation and
the head of the xture can be damaged!
Display - Display adjusting. This menu allows you to adjust the display behaviour.
Turn - This function rotates menu 180 degrees from current orientation..
On/O T - This function allows you to keep the display permanent on (On/O T= O)
or turn it o two minutes after last pressing any button on the control panel (On/O T= On).
Contrast- Use this function to adjust contrast of the display (0-100%).
Backlight- Use this function to adjust backlight of the display (0-100%).
I Ef Pos - Init eect positions. Use the menu to set all eects to the desired positions at which they will stay
after switching the xture on without DMX signal connected.
Defaults - The menu item allows to set all xture parameters to the default (factory) values.
5.4 Manual Control (Manual)
Use the menu to control all xture channels by means of the control panel.
5.5 Reset
This option enables the RoboSpot MotionCamera to index all eects and return to their standard positions.
5.6 Special functions (Special)
RDM Low - This menu item shows the rst part of the RDM identication code.
RDM High - This menu item shows the second part of the RDM identication code.
Wireless - Stat - Use the menu to read wireless DMX status.
Unlink - use this item to unlink xture from wireless DMX.
Adjust - Adjustment. The menu allows the ne adjustment of eects.
DMX Val- DMX values. Use the menu to set DMX values of xture´s channels.
Calib - calibration xture eects.
Cal Mech - Use this menu to calibrate mechanical eects:
Pan C - position of the pan
Tilt C - position of tilt
Calibration of the pan/tilt via the control board
1. Disconnect DMX controller from the xture and enter the "Cal P/T" menu.
2. Use the [PREV] and [NEXT] to nd "Pan" and press [ENTER].
3. Set desired value and save it by pressing [ENTER].
4. Repeat steps 2 and 3 for Tilt.
5. After calibrating both eects, nd item "Store" and press [ENTER]. to save all adjusted values and reset the
xture.
Sw Upd - Software update. The menu item allows you to update software in the xture via either serial or
USB port of PC.
The following are required in order to update software:
- PC running Windows 7/10 or Linux
- Update software
- Flash cable RS232/DMX No.13050624 (if you want to use a serial port of PC)
- Robe Universal Interface (if you want to use an USB port of PC)
Note 1: Software update should execute a qualied person. If you lack qualication, do not attempt the update
yourself and ask for help your ROBE distributor.

12
Note 2: All items in the menu "Pers" will be set to their default (factory) values after software update.
To update software in the xture:
I. Installation of the update software.
1. Update Software available from the ROBE web site at WWW.robe.cz.
2. Make a new directory ( e.g. Robe_Uploader) on your hard disk and download the software to it.
3. Unpack the program to the directory.
II.Fixture software updating.
1.Determine which of your ports is available on your PC and connect it:
- with the DMX input of the xture if you using the ash cable RS232/DMX
- with the USB input of the Robe Universal Interface if you using the USB cable. Connect DMX
output of the Robe Universal Interface with the xture via a standard DMX cabel.
Turn both the computer and the xture on. Make sure the lamp is switched o (only if the xture
has a lamp).
2. Switch the xture to the updating mode (Special -> "SW Upd "-> On).
Note: If you do not want to continue in software update, you have to switch o and on the xture
to escape from this menu.
We recommend to cancel all running programs on PC before starting the software update.
3. Run the Software Uploader. Select desired COM and then click on the Connect button.
(Select COM if the serial port is used or Robe Universal Interface if the USB port is used).
If the connection is OK, click on the “Start Uploading button“ to start uploading. It will take several
minutes to perform software update.
If the option "Incremental Update" is not checked, all processors will be updated (including
processors with the same software version).
If you wish to update only later versions of processors, check the “Incremental Update box“.
Avoid interrupting the process. Update status is being displayed in the Info Box window.
When the update is nished, the line with the text “The xture is successfully updated“ will appear in
this window and the xture will reset with the new software.
Note: In case upload process is interrupted (e.g. power loss), the xture stays in “Updating mode” and you will
have to repeat the software update again.

13
6.
Operation of the RoboSpot MotionCamera with the RoboSpot
6. 1 RoboSpot connection
After installing the RoboSpot, connect it with the RoboSpot MotionCamera and a control desk.
You do not need to patch the RoboSpot, but xtures connected to the RoboSpot have to be patched
6.2 LCD monitor screen operation
The RoboSpot is equipped with the 15.6" (10-point) touch screen with max. resolution 1366 x 768.
1. After switching the RoboSpot and the the RoboSpot MotionCamera on, image scanned by the camera is
displayed.
1- Slider button-after touching the button, sliders for camera zoom, pan/tilt and Track will appear
2- Camera button - after touching the button, options Rotate Picture and Factory Reset will appear
3- IP address of selected camera
4 - Camera selection buttons
5 - Sighting point
Touch the centre of the
Sighting point and
move the Sighting
point to desired
position on the screen.
Touch the edge of the circle and move it in/out to decrease/
increase the size of the Sighting point

14
2. After switching the ROBIN BMFL Spot lamp on and adjusting its beam (zoom, focus, dimmer....), aim the
beam to desired position by means of the FollowSpot Controller handlebars.
3. Move the sighting point on the beam image. Now, when you move with the control handlebars, both beam
image and sighting point on the screen will move synchronously. It is useful in case that the light output from
the xture is closed and by means of the sighting point you approximately know the position of the light beam.
Note: if you change a camera zoom, you have to move and adjust the sighting point on the beam image again.
Sliders button
Camera Zoom slider- use it to change a zoom of currently selected camera. A sensitivity of a camera zoom
can be set in three levels : low (green slider), medium (yellow slider) and high (red slider).
To change the sensitivity level of the camera zoom, the camera zoom has to be assigned to some rotary encoder
of the FollowSpot Controller, please see the chapter "Functions mapping" in the RoboSpot user manual how
to change sensitivity level of a slider.
Pan/Tilt sliders - use them to move a moving head to the desired position. A Sensitivity of pan/tilt movement
can be set in three levels : low (green slider), medium (yellow slider) and high (red slider).
In order to switch the sensitivity of pan or tilt movement to desired level, press and hold the PAN or TILT button
on the FollowSpot Controller until the colour of fader is changed.

15
Track slider- use it to set desired level of speed of pan/tilt movement. Each level of the track slider responds to
certain DMX value of the Pan/Tilt speed channel in DMX chart of BMFL xture.
Track level DMX value on the Pan/Tilt speed channel
Smooth 0
Fast 1
Medium 10
Slow 20
Camera buttons
Rotate Picture- use this function to rotate a picture on the touch screen 180 degrees from current orientation.
Factory Reset- use this function to set a camera to the current setting.
Both items stated above relate to the selected camera in the menu bar.
When you switching between cameras, a eld with video synchronization status is displayed. This eld shows
a delay between camera and the screen. The value 0% means max. delay, 100% is without delay (and this
eld will disappear from the screen after reaching 100%).
If you wish to stream the camera video over computer network, use a rtsp stream supported media player (e.g.
VLC media player, SMPlayer,...) running on your computer and type the following to your media player:
rtsp://IP address of camera/prole2/media.smp
example: rtsp://10.195.165.223/prole2/media.smp
video synchronization
eld

16
7. RDM
This xture supports RDM operation. RDM (Remote Device Management) is a bi-directional communications
protocol for use in DMX512 control systems, it is the new open standard for DMX512 device conguration and
status monitoring.
The RDM protocol allows data packets to be inserted into a DMX512 data stream without adversely aecting
existing non-RDM equipment. By using a special „Start Code,“ and by complying with the timing specications
for DMX512, the RDM protocol allows a console or dedicated RDM controller to send commands to and receive
messages from specic moving lights.
RDM allows explicit commands to be sent to a device and responses to be received from it.
The list of commands for RoboSpot MotionCamera is the following.
Parameter ID Discovery command SET command GET command
DISC_UNIQUE_BRANCH *
DISC_MUTE *
DISC_UN_MUTE *
DEVICE_INFO *
SUPPORTED_PARAMETERS *
SOFTWARE_VERSION_LABEL *
DMX_START_ADDRESS * *
IDENTIFY_DEVICE * *
DEVICE_MODEL_DESCRIPTION *
MANUFACTURER_LABEL *
DEVICE_LABEL * *
SENSOR_DEFINITION *
SENSOR_VALUE *
DISPLAY_INVERT * *
DISPLAY_LEVEL * *
PAN_INVERT * *
TILT_INVERT * *
DEVICE_RESET *
DMX_PERSONALITY * *
DMX_PERSONALITY_DESCRIPTION *
STATUS_MESSAGES *
STATUS_ID_DESCRIPTION *
DEVICE_HOURS *
PARAMETER_DESCRIPTION *
ROBE_DMX_INPUT * *
ROBE_WIRELESS_UNLINK *
RDM model ID for the RoboSpot MotionCamera is 0x00e7
8. Error and information messages
Tilt Err
This message will appear after the reset of the xture if the head´s magnetic-indexing circuit malfunctions
(sensor failed or magnet is missing) or the stepping motor is defective or its driving IC on the PCB. The head
is not located in the default position after the reset.
Pan Err
This message will appear after the reset of the xture if the head´s magnetic-indexing circuit malfunctions
(sensor failed or magnet is missing) or the stepping motor is defective or its driving IC on the PCB. The head
is not located in the default position after the reset.

17
9. Technical Specications
Electrical
Power supply: electronic auto-ranging
Input voltage range: 100-240V, 50-60Hz
Fuse: T 1A
Max. power consumption: 35W (I=0.3A at 230V, power factor=0.51)
Mains input: CE - max. 16A
ETL - max. 10A
Mains output: CE - max. 15A
ETL - max. 9A
Camera
Type: SNZ-6320
Max. resolution: 1920 x 1080
16 : 9 Full HD (1080p) resolution support
32x optical zoom, 16x digital zoom
H.264, MJPEG dual codec, Multiple streaming
Day & Night (ICR), WDR (120dB)
Pan/Tilt
Pan movement range 540°
Tilt movement range 270°
16 bit movement resolution
Automatic Pan/Tilt position correction
Remotely controllable speed of pan/tilt
Movement control: tracking and vector
Control
2-row LCD display & 4 buttons
Readout xture usage, receiving DMX values, temperatures, etc
Built-in analyzer for easy fault nding, error messages
Supported protocols: USITT DMX 512, RDM,
8 control channels
External Wireless DMX/RDM module (option)
Compliance with USITT DMX-512 (1986 & 1990) and 512-A
Full DMX delity and frame integrity
Auto sensing of DMX frame rate and frame size
<5ms DMX latency
Operational frequency range of 2402-2480 MHz
Producer: LumenRadio
Connection
DMX data in/out: Locking 5-pin XLR
Power IN: Neutrik True oneNAC3MPX
Power OUT: Neutrik True One NAC3FPX
Camera: RJ 45
Rigging
Mounting points pair of 1/4-turn locks
Mounting horizontally or vertically via mounting bracket Omega CL
Temperatures
Maximum ambient temperature : 45° C
Maximum housing temperature : 55° C

18
Total heat dissipation
150 BTU/h (calculated)
Weight
5.7 kg
Dimensions (mm)
Included items
1 x RoboSpot MotionCamera
1 x Mounting bracket Omega CL (P/N 99010420)
Optional accessories
(P/N 10980127) Robe Wireless CRMX-LB100
(P/N 1305 2439) Daisy Chain PowerCon TRUE1 In/Out, EU, 2m, indoor
(P/N 1305 2440) Daisy Chain PowerCon TRUE1 In/Out, US, 2m, indoor
(P/N 13052444) Daisy Chain PowerCon TRUE1 In/Out, EU, 5m, indoor
(P/N 1305 2405) Mains Cable PowerCon In TRUE1/Schuko, 2m, indoor
(P/N 1305 2406) Mains Cable PowerCon In TRUE1/US, 2m, indoor
(P/N 1305 2407) Mains Cable PowerCon In TRUE1/open ended, 2m, indoor
(P/N 13052443) Mains Cable PowerCon In TRUE1/Hubb 2321, 2m US, indoor
(P/N 13052445) Mains Cable PowerCon In TRUE1/CEE 16A, 2m, indoor

19
10. Maintenance and cleaning
DANGER !
Disconnect from the mains before starting any
maintenance work
Never use solvents for cleaning the front lens and covers of the xture
It is absolutely essential that the xture is kept clean and that dust, dirt and smoke-uid residues must not build
up on or within the xture.
A soft lint-free cloth moistened with any good glass cleaning uid is recommended, under no circumstances
should alcohol or solvents be used!
Camera lens may require weekly cleaning as smoke-uid tends to building up residues.
The interior of the head and base should be cleaned at least annually using a vacuum-cleaner.
Periodically clean the air lter placed in the xture base. Use a vacuum cleaner, compressed air or you can
wash it and put back dry.
More complicated maintenance and service operations are only to be carried out by authorized distributors.

20
2. Remove the plastic covers of the base (1) by unscrewing two
fastening screws (2) on each cover.
3. Unscrew four screws (3) on the top chassis (4). Lay down
the xture and unscrew four screws (5) on the bottom plate
(8) to push out inside module of the base.
4. Unscrew two screws (7) on the bottom plate to remove
rear panel of the xture (6).
5. Now you have access to the fuse holder (9) in
the inside module of the base.
6. Remove the old fuse from the fuse holder.
7. Install the new fuse into the fuse holder.
8. Assemble the base of the xture.
10.1 Replacing the fuse
Before replacing the fuse, unplug mains lead!
1.Replace the fuse by a fuse of the same type and rating only.
Other manuals for RoboSpot
2
Table of contents