Ropox Maxi 2 User manual

Ropox Nursing table Maxi 2
Usermanual
Mounting Instruction
This manual need to follow the product
PDF 6140 / 28.05.2018

Page 2
Contents
Product information ................................................................................................................................................... 3
Item number .............................................................................................................................................................. 3
Technical data ............................................................................................................................................................ 4
Daily use..................................................................................................................................................................... 4
Recommendations for use.......................................................................................................................................... 5
Important information before mounting .................................................................................................................... 6
Placement of 230V socket, hot and cold water and drain ........................................................................................... 6
Receiving the nursing table........................................................................................................................................ 7
Dimension sketch ....................................................................................................................................................... 7
Mounting Instructions ................................................................................................................................................ 7
1.Mounting to the wall............................................................................................................................................... 8
2. Mounting of the lower cover .................................................................................................................................11
3. Mounting of the upper cover.................................................................................................................................11
4. Connection of the worktop....................................................................................................................................12
5. Connection of the safety stop ................................................................................................................................13
6. Connection of water and drain ..............................................................................................................................14
Wiring circuit .............................................................................................................................................................18
Connections...............................................................................................................................................................19
Dismounting ..............................................................................................................................................................19
Performance test.......................................................................................................................................................20
Labelling ....................................................................................................................................................................21
Label..........................................................................................................................................................................21
Symbols:....................................................................................................................................................................21
Support................................................................................................................................................ 22
Troubleshooting ........................................................................................................................................................22
Waste ........................................................................................................................................................................22
Factors affecting the product during storage and transport.......................................................................................22
Maintenance .............................................................................................................................................................23
Cleaning.....................................................................................................................................................................23
Declaration of conformity..........................................................................................................................................28
Claims.................................................................................................................................................. 28

Page 3
Generel informations
Product information
Product : Ropox Nursing table Maxi 2, Heightadjustable
Producer : Ropox, DK-4700 Naestved, Tel. +45 55 75 05 00
The height adjustable nursing table is designed for nursing children up to 75 kg. The
nursing table can be used I private homes, daycare centers or similar institutions to
ensure correct and optimal working conditions for staff.
The height adjustment is performed by pressing the up and down buttons on the
handset.
Item number
Lenght of
the nursing
table
Part no.
90cm
50-50672
130cm
50-50670
It is important to read this manual before mounting and use of
the nursing table.

Page 4
Generel informations
Technical data
Power consumbtion: 230V, 50Hz, max 2.0A
Standby consumption: 7W
Duty cycle: Maks. 10%, 2min/18min
Height: Workheight 40 –100cm
Speed: 50mm/s
Material –the frame: Welded steeltubes St.37, stainless steel and aluminum
The worktop: ABS/PMMA
Surface: Powder-coated, white RAL 9010 mat, chromate
Max. load: 75 kg
This product has CE marked according to the Machinery, Low Voltage and
EMC Directives. It has been tested according to European standards DS /
EN ISO 12182 and DS / EN ISO the 60335th
Daily use
Before using this product, it is important that the main
power is applied as described under electrical
connections.
The height of the nursing table is adjusted by pressing
the up and down buttons on the handset.
Max. load on the nursing table: 75kg.
Warning !!
During height adjustment of the nursing table, there is a risk of
getting jammed between table and adjacent objects.
Before using the table, ensure that there are no objects
preventing movement of the table.
!! The product must NOT be operated by children!!

Page 5
Generel informations
Recommendations for use
Height adjustment allows individual working height for each employee and can also
help to reduce the number of lift when transferring from example: a wheelchair
user.
To ensure optimum utilisation of the functions of the
nursing table and to avoid accidents, it is important to
observe these basic safety procedures.
NEVER leave a child on the nursing table unattended - not even for a short period.
The nursing table should only be used by adults.
Pay special attention to other people who may stay in the room while using the
nursing table. Make sure that no children are playing under or with the table.
Make sure that children cannot operate the nursing table unintentionally.
See that there is free space above and below the table to allow height adjustment.
Make sure that there are no obstacles above, below or around the nursing table in
order to avoid the risk of getting jammed during height adjustment.
If the handset is damaged or does not work, replace it immediately. The buttons are of
the "press and keep pressed" type. The motor stops when the press on the button
removed. This is an important safety factor.
If two nursing tables are mounted in the immediate vicinity of each other, it is
recommended to mount a side cover between them to prevent the risk of getting
jammed.
Be constantly aware of objects under the nursing table.

Page 6
Mounting instruction
Important information before mounting
Make sure that there is free space on all sides of the nursing table as shown below.
Placement of 230V socket, hot and cold water and drain
If possible, socket for 230V and drain and connection for hot and cold water should be
located as shown on the above sketch.
The length of the mains cable is 3,2 m.
Nursing table Maxi 2,
90 cm
Nursing table maxi 2,
130 cm
70 cm

Page 7
Mounting instruction
Receiving the nursing table
Dimension sketch
These mounting instructions comprise:
Lifting unit x1 Mounting screws x7
Covers for the lifting unit x1 Rawlplugs x7
Worktop x1 Bolts M5 x 25 x6
Bolt M4 x 10 x9
Safety plate x1 Bolts M8 x 20 x2
Drain and water hose kit x1 Cable, Safety stop x1

Page 8
Mounting Instructions
1.Mounting to the wall
The nursing table is being supplied with a set (8 pcs) of screws and rawlplugs, which
is ONLY used to mount the unit in a concrete wall. The installer must always
examine the material, condition and strength of the wall and use appropriate screws
and rawlplugs.
Nursing table has a max user weight of 75 kg.
Maximum load in the top screws are 20kg for each screw.
The holes for fastening can be marked up on the wall, four possibilities in the top,
and four in the bottom of the frame. Place the frame against the wall and make sure
it is horizontal. The frame is standing on two adjustable feet. The holes in the frame
are all Ø 10 mm. Remove the frame and drill the holes.
Force for each of the four screws in top of the unit:
Fscrew = (75 kg * 830)/(790 * 4 screws)
Fscrew =20 kg for each screw
If you have other objects mounted right next to this nursing table, you have to
consider the risk of trapping, and therefore consider a safe distance to other
objects.
Make sure that no dust or other obstacles are interfering with the rollers, chain,
sprocket or gas springs. This can cause malfunction and damage the system
F=Screw
F=75kg

Page 9
Mounting instruction
Mounting to the wall

Page 10
Mounting instruction

Page 11
Mounting instruction
2. Mounting of the lower cover
3. Mounting of the upper cover

Page 12
Mounting instruction
4. Connection of the worktop
5. Mounting of the worktop

Page 13
Mounting Instruction
5. Connection of the safety stop

Page 14
Mounting Instruction
6. Connection of water and drain

Page 15
Mounting Instruction

Page 16
Mounting Instruction
7. If the table top is not in horizontal level

Page 17

Page 18
Electrical components
Wiring circuit
The nursing table comes with control box mounted on the frame. The diagram
shows how to connect the cables with the control box.
All plug-in connections are waterproof, and mounting/dismounting may therefore
be a little difficult. Make sure that all plugs have the correct position before
inserting them into the control unit. The plugs must be pressed home until the O-
ring is no longer visible.
Motor and control box has an IPX6 rating. This means that they are dust-and
waterproof.
The electrical system is designed for intermittent use, which means a maximum duty
cycle of 10%; 2min on / 18min from.
1. Controlbox
2. Mains cable 230V
3. Actuator, connects to 1
4. Handset
5. Safety stop
1
5
2
3
4

Page 19
Electrical components
Connections
The nursing table comes with control box mounted on the frame.
Motor cable connected to port 1. Ports 2, 3 & 4 are not used and are therefore
provided by blind plug.
Handset must be connected to ”HB”.
The mains cable must be connected to the port on
the side of the control box.
Dismounting
Just pull out the mains cable.
In order to maintain the full IPX6 protection class, it is very important that all cables
have been mounted correctly.

Page 20
Performance test
After installation and prior to use all functions of nursing table must be tested. The
test must be carried out by competent personnel. Subsequently the test shall be
carried out once a year.
Testing prior to connection to mains voltage:
1. Check that mounting instructions have been observed
2. Check that all bolts have been tightened.
3. Check that all cables have been connected correctly and that the plugs have
been pressed home.
4. Check that there is no load on the frame.
5. Check that there is nothing preventing the nursing table from moving freely
within the height adjustment range.
Connect main power to control box and continue testing:
1. Press DOWN button, move frame to bottom position & check movement is
even and controlled. Be aware that hoes connections follow movement of
frame and do not get trapped.
2. Press UPWARDS button, move frame to top position & check movement is
even and controlled. Also, be aware that tabletop does not bump into wall.
Should this be the case it could be because the wall is skewed. If the wall is
only a little skewed (1-2mm) it is possible to adjust by moving the tabletop.
The tabletop is fastened with Velcro. Remove tabletop from Velcro in
opposite side of washbasin and slightly pull away from wall and secure again.
3. If the wall is skewed more that 2mm the lifting unit has to be jacked away
from the wall.
4. Press DOWN on control switch and let frame move 2-5 cm downwards,
activate the safety stop. The frame must stop downwards movement
If all tests are ok, the nursing table is ready for use. See section “Safety in use”.