manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Roule
  6. •
  7. Measuring Instrument
  8. •
  9. Roule RL-9816C1 User manual

Roule RL-9816C1 User manual

Popular Measuring Instrument manuals by other brands

Powerfix Profi 278296 Operation and safety notes

Powerfix Profi

Powerfix Profi 278296 Operation and safety notes

Test Equipment Depot GVT-427B user manual

Test Equipment Depot

Test Equipment Depot GVT-427B user manual

Fieldpiece ACH Operator's manual

Fieldpiece

Fieldpiece ACH Operator's manual

FLYSURFER VIRON3 user manual

FLYSURFER

FLYSURFER VIRON3 user manual

GMW TG uni 1 operating manual

GMW

GMW TG uni 1 operating manual

Downeaster Wind & Weather Medallion Series instruction manual

Downeaster

Downeaster Wind & Weather Medallion Series instruction manual

Hanna Instruments HI96725C instruction manual

Hanna Instruments

Hanna Instruments HI96725C instruction manual

Nokeval KMR260 quick guide

Nokeval

Nokeval KMR260 quick guide

HOKUYO AUTOMATIC UBG-05LN instruction manual

HOKUYO AUTOMATIC

HOKUYO AUTOMATIC UBG-05LN instruction manual

Fluke 96000 Series Operator's manual

Fluke

Fluke 96000 Series Operator's manual

Test Products International SP565 user manual

Test Products International

Test Products International SP565 user manual

General Sleep Zmachine Insight+ DT-200 Service manual

General Sleep

General Sleep Zmachine Insight+ DT-200 Service manual

Sensa Core Lacto Spark user manual

Sensa Core

Sensa Core Lacto Spark user manual

VOLTCRAFT UTS-1980 operating instructions

VOLTCRAFT

VOLTCRAFT UTS-1980 operating instructions

EBCHQ 94915 Operation manual

EBCHQ

EBCHQ 94915 Operation manual

Balluff BIP LD2-T017-01-EP-S4 Series user guide

Balluff

Balluff BIP LD2-T017-01-EP-S4 Series user guide

Pulsar IMP Lite Series instruction manual

Pulsar

Pulsar IMP Lite Series instruction manual

ETCR 6800 user manual

ETCR

ETCR 6800 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

CAR WARNING INDICATOR
MODEL: RL-9816C1
Version 1.3
USER MANUAL
NOTE: This equipment has been tested and found to comply with the limits for a Class
B digital device, pursuant to part 15 of the FCC Rules. These limits aredesigned to
provide reasonable protection against harmful interference in aresidential
installation. This equipment generates uses and can radiate radiofrequency energy
and, if not installed and used in accordance with the instructions,may cause harmful
interference to radio communications. However, there is noguarantee that
interference will not occur in a particular installation. If thisequipment does cause
harmful interference to radio or television reception, whichcan be determined by
turning the equipment off and on, the user is encouraged totry to correct the
interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
-Connect the equipment into an outlet on a circuit different from that to which
thereceiver is connected.
-Consult the dealer or an experienced radio/TV technician for help
Changes or modifications not expressly approved by the party responsible for
compliance could void the user's authority to operate the equipment. This device
complies with Part15 of the FCC Rules. Operation is subject to the following two
conditions:
(1) this device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that
maycause undesired operation.
1
Function Description
Operating Instructions
This product adopts RF transmitter/receiver modules and learning code for easy and
convenient operation. The Outdoor Unit is a PIR transmitter. When the Outdoor Unit
detects thermal infrared signals (e.g. moving person), it will send a RF signal to the
Indoor Unit. The indoor unit will then emit two "Ding-Dong" sounds and the LEDs will
flash twice to remind you.
2
Working
Current
Standby
Current
Alarm
Volume
(0.3m)
RF
Working Distance
(Open Area)
Receiver (Indoor Unit)
PIR Detection Distance
PIR Detection Angle
Transmitting Time Interval
RF
PIR Transmitter (Outdoor Unit)
Specifications
Battery
<100mA
Max.
Average
4mA
0.2mA
Lo Level
Hi Level
83-88dB
88-93dB
≈80m
Battery DC4.5V(AA*3)
<20mA
<35uA
0-8m
≤120°
12S±2S
≈80m
DC4.5V(AA*3)
Working Distance
(Open Area)
Standby
Current
Working
Current
Slide switch operating desprition
Hi: Turn the warning indicating voume to High level.
Low: Turn the warning indicating volume to Low level.
Silent: Mute with light flashing.
Learning Code
Slide the receiver switch to Hi or Low and then insert batteries, it will emit a
“DingDong” sound. Later, press the “Code” button at the back of the receiver.
Then powerup the PIR transmitter to trigger the working indicator light, which
means a RFsignal has been sent. If the receiver receives the signal, it will emit a
"Ding-Dong"sound and the indicator light will flash to indicate that the code is
learned successfully.
Clearing Code
Press the Code button and at the same time power on the unit, it will give a "Ding
-Dong" tone. Press and hold the Code button for more than 6 seconds, the receiver
will give tones of "Di-Di-Di, Ding-Dong", which means the code has been cleared
successfully.
"Silent" level description: When the receiver
receives the RF signal, no indicating sound will be given but the light will flash for
10 seconds.
Low Voltage Indicating description:
Receiver: When the voltage is lower than 3.3V, the LED light will be on constantly.
PIR Transmitter: When the voltage is lower than 3.3V, the LED light will be on constantly.
Recommended installation height: 1m±0.2m
Warm Tips:
1. When the PIR transmitter is powered on for the first time, it needs 40 seconds
to be ready to work normally. The time interval for each PIR trigger is 12 seconds.
If human is detected within the time interval, the countdown of time interval will
be re-started.
2. The PIR detection range may vary in different working environments, especially
in the area where the temperature is uneven.
50.00º
20.00º
80.00º
110.00º
2m 4m 6m X
8m
Y
0
1.5m
110º 80º 50º 20º
Diagram of PIR Detection Area
433.92M±250KHz 433.92M±250KHz