RSF Woodburning Fireplaces MicroAMP User manual

MAKING THE DIFFERENCE
TO YOUR VISITOR EXPERIENCE
MicroAMP User Guide
Commercial Division
RSF Europe sa
10b, route d’Arlon
L-7471 Saeul
G.D. of Luxembourg
Tel. +352 49 74 20 40
Fax +352 49 74 20 50
Manufacturer
RSF
45, Av. Marcel Dassault
31500 Toulouse
France
Tel. +33 5 61 20 79 09
Fax +33 5 61 80 00 94
www.rsf-int.com
MicroAMP
User Manual

MAKING THE DIFFERENCE
TO YOUR VISITOR EXPERIENCE
MicroAMP User Guide
Commercial Division
RSF Europe sa
10b, route d’Arlon
L-7471 Saeul
G.D. of Luxembourg
Tel. +352 49 74 20 40
Fax +352 49 74 20 50
Manufacturer
RSF
45, Av. Marcel Dassault
31500 Toulouse
France
Tel. +33 5 61 20 79 09
Fax +33 5 61 80 00 94
www.rsf-int.com
Connections
The MicroAMP is a miniature audio amplier idea for installations where discretion is key.
It’s small size and simple operation allow the installation and running simple enough to
allow project managers to concentrate on more pressing matters.
All that needs to be done to use the MicroAMP is connect a line level audio source with
RCA/cinch connectors, the speakers using phoenix blocks, and the 12V power adapter
using a phoenix block or BT connector
Right channel input
Left channel input
Power input Left output
Right output
Left volume control
Right volume control

MAKING THE DIFFERENCE
TO YOUR VISITOR EXPERIENCE
MicroAMP User Guide
Commercial Division
RSF Europe sa
10b, route d’Arlon
L-7471 Saeul
G.D. of Luxembourg
Tel. +352 49 74 20 40
Fax +352 49 74 20 50
Manufacturer
RSF
45, Av. Marcel Dassault
31500 Toulouse
France
Tel. +33 5 61 20 79 09
Fax +33 5 61 80 00 94
www.rsf-int.com
Connect this unit’s AC power adaptor only to an AC outlet of
the type stated in this Owner’s Manual or as marked on the
unit. Failure to do so is a re and electrical shock hazard.
Do not allow water to enter this unit or allow the unit to
become wet. Fire or electrical shock may result.
Do not place a container with liquid or small metal objects on
top of this unit.
Liquid or metal objects inside this unit are a re and electrical
shock hazard.
Do not place heavy objects, including this unit, on top of the
power cord. A damaged power cord is a re and electrical
shock hazard. In particular, be careful not to place heavy
objects on a power cord covered by a carpet.
Do not scratch, bend, twist, pull, or heat the power cord. A
damaged power cord is a re and electrical shock hazard.
Do not remove the unit’s cover. You could receive an
electrical shock. If you think internal inspection, maintenance,
or repair is necessary, contact your dealer.
Do not modify the unit. Doing so is a re and electrical shock
hazard.
If lightning begins to occur, turn off the power switch of the
unit as soon as possible, and unplug the power plug from the
electrical outlet. If there is a possibility of lightning, do not
touch the power plug if it is still connected. Doing so may be
an electrical shock hazard.
Use only the included AC power adaptor for this unit.
Using other types may be a re and electrical shock hazard.
If the power cord is damaged (i.e., cut or a bare wire is
exposed), ask your dealer for a replacement. Using the unit
with a damaged power cord is a re and electrical shock
hazard.
Should this unit and AC adaptor be dropped or the cabinet
be damaged, turn the power switch off, remove the power
plug from the AC outlet, and contact
your dealer. If you continue using the unit without heeding this
instruction, re or electrical shock may result.
If you notice any abnormality, such as smoke, odour, or noise,
or if a foreign object or liquid gets inside the unit, turn it off
immediately. Remove the power plug from the AC outlet.
Consult your dealer for repair. Using the unit in this condition is
a re and electrical shock hazard.
Keep this unit away from the following locations:
- Locations exposed to oil splashes or steam, such as near
cooking stoves,humidiers, etc.
- Unstable surfaces, such as a wobbly table or slope.
- Locations exposed to excessive heat, such as inside a car
with all the windows closed, or places that receive direct
sunlight.
- Locations subject to excessive humidity or dust
accumulation.
Hold the power plug when disconnecting it from an AC outlet.
Never pull the cord. A damaged power cord is a potential re
and electrical shock hazard.
Do not touch the power plug with wet hands. Doing so is a
potential electrical shock hazard.
To relocate the unit, turn the power switch off, remove the
power plug from the AC outlet, and remove all connecting
cables. Damaged cables may cause re or electrical shock.
Do not cover or wrap the AC power adaptor with a cloth
or blanket. Heat may build up under the cloth or blanket,
melting the case, or causing re. Use only in a well-ventilated
environment.
If you know you will not use this unit for a log period of time,
such as when going on vacation, remove the power plug from
the AC outlet. Leaving it connected is a potential re hazard.
Disposal of used batteries
The user is legally obliged (battery regulation) to return
used batteries and storage batteries. Do not dispose of
used batteries via the household rubbish! Batteries/storage
batteries containing harmful substances are marked with the
following symbols indicating that they are not allowed to be
disposed of in the domestic refuse.
The designations for the respective hazardous heavy metals
are: Cd = cadmium, Hg = mercury, Pb = lead. You can
return used batteries/storage batteries free of charge to any
collecting point in your local authority or in any other store
where batteries/storage batteries are sold.
CE certication
This product is EC-compliant with all required guidelines

MAKING THE DIFFERENCE
TO YOUR VISITOR EXPERIENCE
MicroAMP User Guide
Commercial Division
RSF Europe sa
10b, route d’Arlon
L-7471 Saeul
G.D. of Luxembourg
Tel. +352 49 74 20 40
Fax +352 49 74 20 50
Manufacturer
RSF
45, Av. Marcel Dassault
31500 Toulouse
France
Tel. +33 5 61 20 79 09
Fax +33 5 61 80 00 94
www.rsf-int.com
Technical specications
Audio parameters
Bandwidth 20Hz to 20KHz
Distortion below 0,01%
Dynamic range 92 dB
Amplier power 2 x 3 W RMS (4 Ohm) or
1 x 6 W (8 Ohm)
(bridged mode)
Connectors
Audio input RCA cinch (2X)
Audio output Twin contact Phoenix
Block terminal (x2)
Power supply Twin contact Phoenix
Block terminal or
BT connector
Power supply 12VDC / 500 mA
(external)
Maximum consumption 0,5W to 2,5W
Enclosure Black metal casing
Dimensions (enclosure) 114x78x28 mm (L x W x H)
Weight 115 gr (without PSU)
Environment
Temperature 0°C (32°F) to 50°C
(122°F)
Humidity 0-90%
Warranty 8 years
Table of contents
Other RSF Woodburning Fireplaces Amplifier manuals