Rumble Tuf Duo Electric Breast Pump Assembly instructions

Rumble Tuff
Duo Electric Breast Pump
Instructions & Assembly
for 201D and 203D Device


Congratulations
Congratulations on your new Rumble Tuff ®Duo Electric Breast Pump! The Rumble Tuff ®Duo Electric Breast Pump is
perfect for many occasions.
● Collecting breast milk while you're away from your baby
○ for example: when you're at work
● Relieving engorgement
○ for example: when your baby's feeding habits change because they're eating more solids
● Maintaining your milk supply if you have to temporarily stop breast feeding
○ for example: to express unsuitable milk while you are undergoing medical treatment
The Rumble Tuff ® Duo Electric Breast Pump provides many of the features busy moms love.
● 3 cycles of expressions to mimic baby's nursing patterns.
○ Reex Expression - Lach on & Rooting habit
○ Swift Expression - Fast but shallow swallowing habit
○ Natural Expression - Steady and strong swallowing pattern
● Milk back-ow protection
● Quiet motor for discretion
● Small and lightweight
● 2 power options to t your needs
○ AC/DC Adapter
○ 4 AA Alkaline battery (PA203D) OR Li-Ion Rechargeable battery (PA201D)
● Convert to Manual Pump in seconds (Parts included)
Indication for Use
The Rumble Tuff ® Duo Electric Breast Pump is a personal use, electrically powered device used to express milk from
the breasts of lactating women. This device is not intended for hospital use.
English 0

English 1
Table of Contents
Congratulations
Indication for Use
Important Safeguards
● DANGER
● CAUTION
● WARNING
Parts Guide
● Electrical Pump Main Unit
● LCD Screen Guide
● Expression Collection Combo Kit
How to Assemble the Expression Collection Kit
How to Assemble Electric-pump Diaphragm Kit
How to Assemble Expression Collection Combo Kit
Power Options
● Using your AC/DC Adapter (included)
● Using the Li-Ion Rechargeable Battery (for PA201D only)
● Install the Battery: (Li-Ion Rechargeable)
● Using 4 AA Alkaline Batteries (for PA203D only) (Batteries not included)
● Install the Batteries (AA Alkaline)
Pumping Instructions
Suction Level
M Button
Setting the Time
● How to Adjust the Clock
Alarm Clock Mode
● How to Adjust the Alarm
Cleaning Instructions
● Sanitize Prior to First Use
........................................................................................................................
.....................................................................................................................
..............................................................................................................
.................................................................................................................................
................................................................................................................................
...............................................................................................................................
.............................................................................................................................
..............................................................................................................
......................................................................................................................
.....................................................................................................
......................................................................
......................................................................
...............................................................
........................................................................................................................
...............................................................................................
........................................................................
...........................................................................................
.......................................................
.....................................................................................................
..............................................................................................................
..........................................................................................................................
..................................................................................................................................
......................................................................................................................
................................................................................................................
...................................................................................................................
...............................................................................................................
..............................................................................................................
..............................................................................................................
0
0
3
3
3
3
5
6
6
7
8
11
12
14
14
15
16
18
19
21
26
27
28
28
30
30
32
32

● Before Each Use
● General Cleaning Instructions
● Tubing Cleaning Instructions
Breastmilk Storage Guidelines
● Important Notes
Tips
● Pumping Tips
● Battery Storage
● Breastfeeding Tips
Troubleshooting
● Interruption of Electrical Service
● Radio Frequency Energy
● Decreased Suction
● Breastmilk Buildup in the Breastshield Body
● Where to get Replacement Parts
● Where to get Additional Accessories
● What Additional Accessories are Available
Technical Data
● Power Requirements
Manual Breast Pump - Quick Reference Guide
● Parts Guide
● How to Assemble the Expression Collection Combo Kit
● How to Assemble the Manual-Pump Diaphragm Kit
● Using the Manual Pump
● Troubleshooting
Warranty
........................................................................................................................
........................................................................................................
..........................................................................................................
................................................................................................
.........................................................................................................................
..........................................................................................................................................
............................................................................................................................
.........................................................................................................................
......................................................................................................................
......................................................................................................................
......................................................................................................
...............................................................................................................
......................................................................................................................
.........................................................................................
.....................................................................................................
.................................................................................................
..........................................................................................
........................................................................................................................
...................................................................................................................
......................................................................
..............................................................................................................................
...........................................................................
................................................................................
................................................................................................................
.........................................................................................................................
..................................................................................................................................
32
32
33
34
34
36
36
37
37
38
38
38
38
39
39
39
39
40
40
41
41
42
44
46
47
48
English 2

English 3
Important Safeguards
The Rumble Tuff ®Duo Electric Breast Pump is designed for a single user and should never be
shared or resold; doing so will void the warranty.
READ ALL INSTRUCTIONS BEFORE USING
DANGER: To reduce the risk of electrocution:
● Always unplug this product immediately after using.
● Do not use while bathing.
● Do not place or store this product where it can fall or be pulled into a tub or sink.
● Do not place or drop into water or other liquid.
● Do not reach for an electrical product that has fallen into water. Unplug immediately.
CAUTION:
● Do not use this product for any other purpose than as indicated in the Instructions & Assembly.
● Make sure all the parts are assembled correctly before operating.
● Stop using the breast pump immediately if your breasts or nipples experience any discomfort.
● Please wash hands before using this product.
● Keep this product out of reach of babies and children.
● Do not drop or hit the product to avoid damage.
● Do not touch the product with bare hands right after sterilizing by boiling water to avoid scalds and burns.
● Do not over-boil to avoid premature aging of the product materials.
WARNING: To reduce the risk of burns, electrocution, re, or injury to persons:
● This product should never be left unattended when plugged in.
● Close supervision is necessary when this product is used near children or invalids.
● Use this product only for its intended use as described in this manual. Do not use attachments or parts not recommended by
Rumble Tuff ®.
● Do not operate this product if it has a damaged cord or plug, if it is not working properly, if it has been dropped or damaged,
or if it has been dropped in water.
● Keep the cord away from heated surfaces.
● Do not use while sleeping or drowsy.
● Do not drop or insert any object into any opening or tubing.
● Do not use outdoors with the AC/DC Adapter or operate where aerosol spray products are being used, or where oxygen is
being administered. SAVE THESE INSTRUCTIONS
along with your receipt for future reference.

Important Safeguards (Continued)
● Make sure the voltage of the AC/DC Adapter is compatible with the power source.
● Plug the AC/DC Adapter into the electrical outlet rst, then plug the Power Cord into your Rumble Tuff ®Duo Electric Breast
Pump.
● Rumble Tuff has provided an AC/DC Adapter and/or Li-Ion battery pack with this device. Using any other AC/DC Adapter or
Li-Ion battery pack not approved by the manufacturer voids the warranty.
● If you are infected with Hepatitis A, Hepatitis B, or have HIV (Human Immunodeciency Virus): pumping breast milk does not
reduce or remove the risk of transmitting the virus to your baby through breast milk.
● Wash the Expression Collection Combo Kit parts before each use.
● Do not operate a motor vehicle while using the Rumble Tuff ®Duo Electric Breast Pump.
● Do not attempt to modify the product.
English 4

Parts Guide
Breast Pump Main Unit
AC/DC Adapter
Expression Collection Combo Kit (2 Sets)
Vacuum Tubing with Adapter
Bottle Adapter Kit (2 Sets)
English 5
Manual Diaphragm Add-On Kit

● Electric Pump Main Unit
● LCD Screen Guide
Suction Level indicator
Power indicator
M Button Icon
Alarm indicator
Swift Expression indicator
Natural Expression indicator
Time indicator
AM
PM
LCD Screen
Vacuum Adjusting Wheel
Expression Button
M Button
Power Button
Battery Cover
Tubing Adapter Inlet
AC/DC Adapter Inlet
TOP VIEW BOTTOM VIEW
Parts Guide
English 6

● Expression Collection Combo Kit (Duo)
Parts Guide
Cap
Diaphragm
Cup with O-Ring
Breastshield Body
One-Way Valve
Bottle Adapter
Collection Bottle
Bottle Base
Silicone Cushion
Electric-pump
Diaphragm Kit
Expression
Collection Kit
English 7

How to Assemble the Expression Collection Kit
Your Rumble Tuff ® Duo Electric Breast Pump comes pre-assembled; however, you will need to re-assemble it after
each cleaning. (For cleaning instructions, see page 32) Below is a step-by-step guide for assembling the Expression
Collection Kit:
1. Hold the "horn" of the Breastshield Body in one hand. Make sure the bottle-thread side opening is facing up.
2. With the thumb and forenger of the other hand, hold the tip of the One-Way Valve and place the at circular bottom into the opening.
Be sure not to stretch, bend, or twist the tip of the One-Way Valve. Seal all the edges of the at circular bottom rmly.
Note: The One-Way Valve tip does not have to align with anything, as long as all the edges are securely sealed.
Flat circular bottom
Tip
English 8

How to Assemble the Expression Collection Kit (Continued)
3. With your thumb and forenger, gently smooth closed any openings on the tip of the One-Way Valve and shape into a straight line.
Note: This is critical to the performance of the Pump.
4. Carefully twist on the Bottle Adapter to the Breastshield Body for a secure t.
Note: Be sure not to bump the One-Way Valve when twisting the Breastshield Body & the Bottle Adapter pieces together. If you
bump the One-Way Valve, repeat step 3.
English 9

How to Assemble the Expression Collection Kit (Continued)
5. With the Bottle Adapter in one hand, twist on the Collection Bottle for a secure t.
English 10

How to Assemble Electric-pump Diaphragm Kit
1. With the Cup in one hand, place the Silicone Diaphragm in the Cup (matching the shape of the Cup). Press around the edges of the
Diaphragm for a secure t. Make sure the Diaphragm is evenly mounted on the Cup and there is no gap in between them.
2. Place the Cap on the Cup & Diaphragm. (Be sure to align the hinge and hinge cover.) Press tightly to seal.
Hinge cover
Hinge
English 11

How to Assemble Expression Collection Combo Kit
1. With the O-Ring side down, put the Electric Pump Diaphragm Kit into the top of the Breastshield Body opening. Twist the
Electric-Pump Diaphragm Kit clockwise into the Breastshield Body until it locks into place.
2. With the Breastshield Body in one hand, place the Silicone Cushion in the Breastshield Body (matching the shape of the horn).
Secure the lip of the Cushion around the edges of the horn.
Note: Your Electric Breast Pump will work with or without the Silicone Cushion. Your comfort depends on your preference.
Turn
Clockwise
English 12

How to Assemble Expression Collection Combo Kit (Continued)
3. Take the open-end of Vacuum Tube (the end without the adapter) and connect to the Tubing Connector located on the Cap. Push
together rmly for a tight seal.
Note: Make sure there is no moisture in the tubing.
4. Make sure the Tubing Connector is properly inserted into the Tubing Adapter Inlet on the Electric Pump Main Unit.
Tubing
Connector
*To Use As a Single Pump:
Remove one tube and close the T-connector.
T-connector
English 13

Power Options
1. Plug the AC/DC Adapter into an electrical outlet.
2. Attach the Power Cord to the AC/DC Adapter Inlet on the Electric Pump Main Unit.
Your Electric Breast Pump may be operated under any of the following power supply modes:
Using your AC/DC Adapter (included):
● Electrical safety can only be achieved when using the AC/DC Adapter which was provided with the Pump. Use of any
another Adapters causes concern for the safety of the product and/or the user and voids the warranty.
English 14

Using the Li-Ion Rechargeable Battery (for PA201D only):
● Prior to rst use, charge the battery for 24 hours. If necessary, your Electric Breast Pump can be used during this
period with the Power Cord only. For best results, allow the Pump to initially charge uninterrupted for 24 hours.
● After the initial charge, subsequent charges will take approximately 4 hours. Once charged, you should not need to
remove the battery unless replacing or when storing.
● The Li-Ion Rechargeable Battery will charge every time the AC/DC Adapter is plugged in; however, it will not charge
while your Electric Breast Pump is in use.
● The Power indicator on the LCD Screen shows how much battery power is left. If it starts to ash, showing only
one bar , there is only enough power left for approx. one 20-minute pumping session.
● When charging, the Power indicator should show charging animation on the display screen . If you do
not see charging animation, please check to see if the battery has been installed correctly.
Note:The Li-Ion Rechargeable Battery used in this device may present a risk of re or chemical burn if mistreated.
Do NOT disassemble the battery. Do NOT place battery near heat source or re. Dispose of used battery properly.
Do NOT dispose of battery in re. For long term storage, keep battery within the following temperature range:
32°F to 77°F (0°C to 25°C). Keep away from children.
Li-Ion Battery Compartment Li-Ion Battery
English 15

1. Open the Battery Cover.
2. Remove the old Li-Ion Rechargeable battery by releasing the locking hook. The Battery pops up automatically.
Install the Battery: Li-Ion Rechargeable
English 16

3. Insert the new Li-Ion Rechargeable Battery and push the Battery into the compartment until the Battery is locked into place.
Note: Make sure triangle marks are aligned (on both the Battery and the bottom of main unit).
4. Close the Battery Cover, making sure it "snaps" into place.
Install the Battery: Li-Ion Rechargeable (Continued)
English 17
This manual suits for next models
2