Ruris AquaPower 1008S User manual

Hydrophore
RURIS AquaPower
1008S / 2010S / 2011S /
3009S / 4010S / 5010S /
6009S / 8009S

CONTENTS
1. Introduction.................................................................................... 3
2. Safety instructions ......................................................................... 3
3. General presentation of the machine ............................................ 5
4. Technical data ............................................................................... 6
5. Installation...................................................................................... 9
6. Commissioning ............................................................................ 11
7. Maintenance and storage............................................................ 11
8. Faults and remedial actions......................................................... 12
9. Declarations of conformity........................................................... 14

3
1. INTRODUCTION
Dear customer!
Thank you for your decision to buy a RURIS product and for your trust
in our company! RURIS has been on the market since 1993 and during
all this time has become a strong brand, which has built its reputation
by keeping its promises, but also by continuous investments designed
to help customers with reliable, efficient and quality solutions.
We are convinced that you will appreciate our product and enjoy its
performance for a long time. RURIS not only offers its customers
equipment, but complete solutions. An important element in the
relationship with the customer is the pre-sale and post-sale advice,
RURIS customers having at their disposal a whole network of partner
stores and service points.
To enjoy the purchased product, please browse with attention manual
use. By following the instructions, you will be guaranteed a long use.
RURIS works continuously for the development of its products and
therefore reserves the right to change, among other things, their shape,
appearance and performance, without having to communicate this in
advance.
Thank you once again for choosing RURIS products!
Customer information and support :
Phone: 0351.820.105
2. SAFETY INSTRUCTIONS
Read this manual carefully before installing the hydrophore.

4
Keep this manual carefully. If problems arise, contact the RURIS authorized service.
Please check that the hydrophore has been usedcorrectly and that the problem is caused
by its operation.
Hydrophores can be used for residential applications to pump clean water at constant
pressure; to provide water for toilets, washing machines, dishwashers and to spray the
garden. They can also be used for pressurized systems to increase hydrostatic pressure.
These hydrophores are also suitable for distributing drinking water.
Hydrophor cannot be used for salt water, flammable substances,corrosives or dangerous
liquids. Check that the hydrophore never works without liquids.
Do not point the water jet directly at the machine or other electrical components!
* Do not touch the plug with your wet hand! Unplug the machine, holding the plug, not
the power cord. * Connect only to a grounded outlet, mounted correctly and checked.
The voltage and safety of the circuit must correspond to the specified values.
Protection will be provided by a residual current device (RCD) of max. 30 mA. The
grounded socket or the plug of an extension cord must be placed in areas protected
from contact with water. Use only extension cables with the appropriate cross section
of the conductors. Unwind the cable rollers completely. * Do not bend, crush, pull or
drive over cables and extenders; protect against sharp edges. * Place the extension
cord so that it does not penetrate the pumped liquid. * Unplug the machine before any
service operation.
Before use, check the power cord. Make sure it is intact.
If the cable is damaged during use, disconnect the power immediately.
DO NOT TOUCH THE CABLE BEFORE DETERMINING THE FOOD

5
3. GENERAL PRESENTATION OF THE MACHINE
Hydrophore mounting graph without ejector
1 Hydrophore suction hole
2 Suction pipe
3 Sorb with valve
4 Filter
5 Reful
6 Clapet of meaning
7 Sectioning valve
8 Corp pump
9 Expansion vessel
The ejector of a hydrophore is the component that operates on the basis of a certain
pressure, it being the one with which the water flows are obtained. The use of ejector
hydrophores cancels the use of a submersible pump together with a hydrophore, the

6
ejector actually playing this constructive role, is used especially for larger depths (for
ejector equipment).
Careful! For functionality at the maximum flow capacity of the hydrophore pump and so
that there are noobstacles in theprimingprocess do not change the absorption diameters
of the column.
4. TECHNICAL DATA
Model
1008S
2010S
2011S
Sorb with valve

7
Engine power
750W
900W
1100W
Maximum
absorption depth
9m
9m
9m
Maximum
discharge height
45m
50m
55m
Tank volume
19l
24l
50l
Debit
46l/min
52l/min
58l/min
Turbine
Bronze
Stainless steel
Bronze
Coil
Aluminum
Aluminum
Aluminum
Manometer
Standard
Standard
Standard
Cable length
2m
2m
2m
Bronze coupling
5 ways
3 ways
3 ways
Connector hose
type
42 cm
50cm
55cm
Noise level
71 dB
72 dB
74 dB
Weight
-
-
-
Guarantee
24 months
24 months
24 months
Model
3009S
4010S
5010S
Engine power
1500W
1800W
2200W
Maximum
absorption depth
9m
9m
9m

8
Maximum
discharge height
60m
70m
70m
Tank volume
24l
24l
50l
Debit
55l/min
60l/min
60l/min
Turbine
Bronze
Bronze
Bronze
Coil
Aluminum
Aluminum
Copper
Manometer
Standard
Standard
Standard
Cable length
2m
2m
2m
Bronze coupling
5 ways
5 ways
5 ways
Connector hose
type
50cm
55cm
60cm
Noise level
75 dB
76 dB
84 dB
Weight
-
-
-
Guarantee
24 months
24 months
24 months
Model
6009S
8009S
Engine power
880W
1100W
Maximum
absorption depth
9m
25m
Maximum
discharge height
45m
55m
Tank volume
24l
50l
Debit
46l/min
30l/min
Turbine
Bronze
Bronze
Coil
Aluminum
Aluminum

9
Manometer
Standard
Standard
Cable length
2m
2m
Bronze coupling
5 ways
5 ways
Connector hose
type
50cm
50cm
Noise level
71 dB
72 dB
Weight
-
-
Guarantee
24 months
24 months
5. INSTALLATION
When installing the hydrophore, make sure it is disconnected from the power supply.
Protect the hydrophore and all pipes against adverse weather conditions and frost.
To prevent any damage, avoid inserting your hand into the hydrophore hole if it is
connected.
Use a suction pipe (2) with a diameter equal to that of the hydrophore suction hole (1). If
the height (HA) is over 4 meters use a pipe with a larger diameter. The suction circuit
must be perfectly airtight. There must be no elbows or slopes to prevent the formation of
air bags that could affect the efficiency of the hydrophore. A sorb with filter valve (3) (4)
must be mounted about half a meter below the level of the pump to be pumped (HI) at
one end of the circuit. Load losses can be reduced using discharge pipes with equal or
greater diameterwith hydrophore hole (5). It is recommended to install a directional flap
(6) directly on the discharge circuit to prevent damage to the hydrophore due to " ram
blows".
A sectioning valve (7) below the check valve must also be installed to facilitate service
operations. The pipes must be placed in such a way that the vibrations, if any, the voltage
and mass do not affect the hydrophore. The pipes must be pulled on the straightest and
shortest route, avoiding the use of an excessive number of elbows. Check that the engine

10
is ventilated properly. For permanent installations, it is recommended to fix the
hydrophore on the support or connect the system with a rigid pipe section and insert a
layer of rubber (or other anti-vibrant material) between the support and the hydrophore
to reduce vibrations. The installation site must be stable and dry to ensure the stability of
the hydrophore.
ATTENTION!
The connections, suction and discharge pipes must be connected with the utmost care.
Make sure that all connections attached to the screws are sealed. Avoid applying
excessive force to tighten the screws of the connections or other components. Use the
Teflon strip to completely seal all joints.
In order to use continuous hydrophore in a tank for swimming pools, garden pools and
other similar installations, it is necessary to fix the hydrophore on a stable support. Mobile
hydrophores for swimming pools, garden pools and other similar installations may be
used only if no person is in contact with water or if the electrical system has a protective
switch. Hydrophor must be placed in a fixed position to avoid falling and protect it from
flooding. Contact a specialist electrician.
Electrical connections
Check that the voltage and frequency of the hydrophore in the stamp plate corresponds
to that on the network.
The installer must ensure that the electrical system is grounded in accordance with the
regulations in force.
Make sure the electrical system has a high sensitivity circuit breaker = 30 mA (DIN VDE
0100T739)
Protection to overload
RURIS hydrophores have a built-in thermal protection switch. Hydrophore stops if an
overload occurs. The engine restarts automatically after it has cooled. (see section 3 of
the Defects and remedial actions chapter).
The power cord must have a minimum section equivalent to that of the H07 RN-F cable.
The track and connections must be protected from water jets.

11
6. COMMISSIONING
Before commissioning, fill the suction pipe (2) and the body of the hydrophore (8) using
the filling valve (9). Turn off the tap after checking that there are no leaks. Open the
closing devices on the discharge pipe (eg water tap) so that air can be released from the
suction circuit. Position theswitch on the cover of the "I" switch and insert the hydrophore
plug into an AC outlet. Hydrophore starts immediately. If the hydrophore is not used for
a long time, it is necessary to repeat all the operations described above before starting
the hydrophore.
Presosting adjustment
The hydrophore pressure is preset by the manufacturer at 1.4 bar for starting pressure
and at 2.8 bar for the pressure needed to stop the hydrophore.To change these settings,
contact a qualified electrician.
7. MAINTENANCE AND STORAGE
Make sure the equipment is disconnected from the electrical outlet before
performing maintenance.
Under normal conditions, RURIS hydrophores do not require maintenance. To prevent
any problems, it is recommended to periodically check the pressure provided and the
current absorption. Reducing the pressure could indicate that the hydrophore is worn out.
Sand and other corrosive materials can cause rapid wear and performance reduction. In
this case, it is recommendedto use a filterand select a filter cartridgeadequate depending
on the application. An increase in current absorption indicates the presence of abnormal
mechanical friction in the hydrophore and / or motor.
To avoid problems, it is recommended to periodically check the preload pressure in the
tank. At this point, turn off the hydrophore from the main power supply and open the water
supply to discharge the pressure from the system. Then measure the preload pressure
using the tap behind the tank. Perform the measurement with an independent
manometer. The pressure must be equal to 1.5 bar.Correct the value if it is not correct. If
the hydrophore will not be used for a long time (e.g. one year), it is recommended to
empty it completely (by opening the drain valve), wash it with clean water and store it in
a dry space, where it can be protected from the cold.

12
Do not dispose of electrical, industrial electronic equipment and parts
of household waste! WEEE information. Considering the provisions of
GEO 195/2005 - regarding environmental protection and O.U.G. 5/2015.
Consumers will consider the following indications for the delivery of
electrical waste, specified below :
- Consumers are required not to dispose of waste electrical and electronic equipment
(WEEE) as unsorted municipal waste and to collect these WEEE separately
- The collection of this named waste (WEEE) will be carried out through the Public
Collection Service within the radius of each county and through collection centers
organized by the economic operators authorized for the collection of WEEE. Information
provided by the Environmental Fund Administration www.afm.ro or the journal European
Union.
- Consumers can teach WEEE free of charge at the collection points specified above.
8. FAULTS AND REMEDIAL ACTIONS
PROBLEME
CAUZE PASIBILE
REMEDII

13
HYDROFORULNOT
PAMPEAZA APA,
MATTHE HORSE
DOES NOT
WORKŢIONSHEDAY
1. Not este alimentat
2.Pratectiamataruitui
ofclyearandat
3. Candensatar defect
4. Ratar bitacat
5.Presastatuit este
instaitat incarect sau
esyou ofteriarat
1.Verificayou that este
prezenyour
tenandunota and that a fast
introdus sttethe cartcarect into
the priza.
2. Stabiliți chaveza
probitemeand resetayou
Qntrerubyetaruit. Dathat a fast
activat Qntrerubyetorul termic ,
aSteptayousa se racshesca.
3.
Cantactayouservice
-uit.
4. Verificati cauza
anddebitacayouhydrophore.
5.
Cantactayouservice
-uit.
2.MOTARUL
FUNCŢIONSHEZĂ,
DAR HYDROFORUL
NOT PAMPEADAY
LICHID
1. Galițicarpuit
hydrophore.
2. Intrarshe aeruitui dinto
the teava de aspirayoue.
3 Q.N / Altimea de
aspiratie este sub
vaitaarea
recmanyeardayourpentru
aitate.
1. Apryou hydrophore and
umpiteyou carpul with apa
utilizând rabinottuit de umpitere
(fig. 1, nr. 9).
Verificati ca:
a) racardurauthorities sat
etyearandate.
b) niveituit de fituid nu a scazut
sub sarb.
c) sarbuit este etyearandat and
bitacat.
d) nu există andfaanot, caturi ,
obstacale sau stranguitayou.
3. Verificayou and reduceti îN /
Altmeade aspirato you sau
utitizayouun echipament with
caractercysticadecvate.
3. HYDROFORUL SE
OPRSATE DUPA CE
FUNCŢIONEAZA
OSCURTAPERIOADA
DE TIMP PENTRU CA
UNOTL DIN
QNTRERUWELLTOAR
HEE DE PRATECŢIE
TERMICAS- A
DECLANTOT
1.Alimentarea cu energie
eitectrica nu este in
canfarmitatit's with
datethem dinto the
pitacuta de youmbru
2 A. obiect salid
bitacheazarataareite.
3. Lichiduit este
prea dens.
4. Lichidul sau ambientul
sat prea fierbinyou.
5. Hydrophore
facyouaneaza farafituid,
clapeyour de
reyounerede pe
butrcuituit de aspiratie
este închisa.
1.Verificatenandunota de la
terminaitethem cabituitui de
alimentare.
2. Dezasambitaand
curatayouhydrophore.
3. Diluayou fituiduit
pampat.
4-5. EitimiN / Ati chaveza
probitemei , aSteptayou that
hydrophore to se racshescale
andsa reporneasca.
4. HYDROFORUL
PORNEAndTE AndI SE
OPREAndTE PREA
FRECVENT
1. Membryeara
rezervaruitui
este ofteriarata.
1.Sobidati înitacuireamembranoti
sau a rezervaruitui
onrsanaituituand caitificat.

14
5. HYDROFORUL NO
TOUCH THE DESIRED
PRESSION
1. The pressure required
to turn off the preset
hydrophore on the
pressure is too low.
2. Air intake from the
suction pipe.
1. Contact the service.
2. See point 2.2.
6. HYDROFORUL NO
FUNCTION
OK CONTINUOUS
1. The pressure required
to turn off the preset
hydrophore on the
pressure is too low.
2. Air intake from the
suction pipe.
1. Contact the service.
2. See point 2.2.
9DECLARATIONS OF CONFORMITY.
EC DECLARATION OF CONFORMITY
Manufacturer: SC RURIS IMPEX SRL
Calea Severinului, no. 10, Bl. 317b, Craiova, Dolj, Romania
Goal. 0351 464 632, www.ruris.ro, info@ruris.ro
Authorized representative: eng. Stroe Marius Catalin - General Manager
Authorized person for the technical file: eng. Florea Nicolae - Production Design Director
Car description : Hydrophore with the role of pumping water from wells and drilled wells, to
valves with constant flow.
Serial number: from XXAqua1008S000 to XXAqua1008S9999 (Where xx represents the last
two digits of the year of manufacture)
Product: HIDROFOR
Model:RURIS Type: AquaPower 1008S
Absorbed power : 750W
We, SC RURIS IMPEX SRL Craiova, manufacturer, in accordance with H.G. 1029/2008 -
regarding the conditions for placing cars on the market, Directive 2006/42 / EC - safety and
security requirements, Standard EN ISO 12100: 2010 - Cars. Security, Directive 2000/14 / EC
amended by Directive 2005/88 / EC, H.G. 1756/2006 - on the limitation of the level of noise

15
emissions in the environment, Directive 2014/35 / EU, GD 409/2016 - on low voltage
equipment , Directive 2014/30 / EU , GD 487/2016 - on electromagnetic compatibility, updated,
we have certified the conformity of the product with the specified standards and we declare that
it complies with the main safety and security requirements, does not endanger life, health,
occupational safety and does not have a negative impact on the environment.
I, the undersigned Stroe Catalin, the manufacturer's representative, declare on his own
responsibility that the product complies with the following European standards and
directives :
•SR EN ISO 12100: 2011 - Car safety. Basic concepts, general design principles. Basic
terminology, methodology. Technical principles
•EN 809: 1998 + A1: 2009 + AC: 2010 - Security principles; Water pumps and pumps ;
•EN 60204-1: 2018 - Car electrical equipment - Part 1: General safety requirements ;
•EN 60335-1: 2012+ A13: 2017 - Household electrical appliances and similar purposes.
Security. Part 1: General requirements
•EN 60335-2-41: 2003 + A1: 2004 + A2: 2010 - Household electrical appliances and
similar purposes. Security. Specific requirements for pumps
•EN 62233:2008 + AC: 2008 - Measuring methods for the electromagnetic fields of
household appliances and similar apparatus for human exposure
•EN 60034-1: 2010 + AC: 2010 - Rotary electric machines. Part 1: Evaluation and
performance
•EN 55014-1: 2017 -Electromagnetic compatibility
•EN 55014-2: 2015 - Electromagnetic compatibility
•EN 61000-3-2: 2014 - Electromagnetic compatibility
•EN 61000-3-3: 2013 - Electromagnetic compatibility
•SR EN ISO 3744: 2011 - Acoustics. Determination of sound power levels emitted by
noise sources using sound pressure
Other Standards or specifications used :
•SR EN ISO 9001 - Quality Management System
•SR EN ISO 14001 - Environmental Management System
•OHSAS18001 - Occupational Health and Safety Management System.
Make and name of manufacturer: F.F.P.T. Co. Ltd.
Note: the technical documentation is owned by the manufacturer.
Specification: This declaration complies with the original.
Shelf life: 10 years from the date of approval.
Place and date of issue : Craiova, 20.05.2021
Year of affixing of the CE marking : 2021
Nr. inreg : 469 / 20.05.2021
Authorized person and signature : Eng. Stroe Marius Catalin
General Manager of
SC RURIS IMPEX SRL

16

17
DECLARATION OF CONFORMITY EC
Manufacturer: SC RURIS IMPEX SRL
Calea Severinului, no. 10, Bl. 317b, Craiova, Dolj, Romania
Goal. 0351 464 632, www.ruris.ro, info@ruris.ro
Authorized representative: eng. Stroe Marius Catalin - General Manager
Authorized person for the technical file: eng. Florea Nicolae - Production Design Director
Car description : Hydrophore with the role of pumping water from wells and drilled wells, to
valves with constant flow.
Serial number: from XXAqua1008S000 to XXAqua1008S9999 (Where xx represents the last
two digits of the year of manufacture)
Product: HIDROFOR
Model: RURIS Type: AquaPower 1008S
Absorbed power : 750W
Acoustic power level (relative) : 71 dB (A) Acoustic power level : 71 dB
The sound power level is certified by I.N.M.A Bucharest according to Test Bulletin no. 1 /
22.03.2018 in accordance with the provisions of Directive 2000/14 / EC and SR EN ISO 3744:
2011
We, SC RURIS IMPEX SRL Craiova as a manufacturer , in accordance with H.G. 1029/2008
- regarding the conditions for placing cars on the market, Directive 2006/42 / EC - safety and
security requirements, Standard EN ISO 12100: 2010 - Cars. Security, Directive 2000/14 /
EC amended by Directive 2005/88 / EC, H.G. 1756/2006 - on the limitation of the level of
noise emissions in the environment, Directive 2014/35 / EU, GD 409/2016 - on low voltage
equipment , Directive 2014/30 / EU , GD 487/2016 - on electromagnetic compatibility,
updated,we have certified the conformity of the product with the specified standards and we
declare that it complies with the main safety and security requirements, does not endanger
life, health, occupational safety and does not have a negative impact on the environment.
I, the undersigned Stroe Catalin, the manufacturer's representative, declare on his own
responsibility that the product complies with the following European standards and
directives :
•SR EN ISO 3744: 2011 - Acoustics. Determination of sound power levels emitted by
noise sources using sound pressure
Other Standards or specifications used :
•SR EN ISO 9001 - Quality Management System
•SR EN ISO 14001 - Environmental Management System
•OHSAS18001 - Occupational Health and Safety Management System.
Note: the technical documentation is owned by the manufacturer.
Specification: This declaration complies with the original.
Shelf life: 10 years from the date of approval.
Place and date of issue : Craiova, 20.05.2021
Year of affixing of the CE marking : 2021
Nr. inreg : 470 / 20.05.2021
Authorized person and signature : Eng. Stroe Marius Catalin
General Manager of
SC RURIS IMPEX SRL

18
EC DECLARATION OF CONFORMITY
Manufacturer: SC RURIS IMPEX SRL
Calea Severinului, no. 10, Bl. 317b, Craiova, Dolj, Romania
Goal. 0351 464 632, www.ruris.ro, info@ruris.ro
Authorized representative: eng. Stroe Marius Catalin - General Manager
Authorized person for the technical file: eng. Florea Nicolae - Production Design Director
Car description : Hydrophore with the role of pumping water from wells and drilled wells, to
valves with constant flow.
Serial number: from XXAqua2010S000 to XXAqua2010S9999 (Where xx represents the last
two digits of the year of manufacture)
Product: HIDROFOR
Model:RURIS Type: AquaPower 2010S
Absorbed power : 900W
We, SC RURIS IMPEX SRL Craiova, manufacturer, in accordance with H.G. 1029/2008 -
regarding the conditions for placing cars on the market, Directive 2006/42 / EC - safety and
security requirements, Standard EN ISO 12100: 2010 - Cars. Security, Directive 2000/14 / EC
amended by Directive 2005/88 / EC, H.G. 1756/2006 - on the limitation of the level of noise
emissions in the environment, Directive 2014/35 / EU, GD 409/2016 - on low voltage
equipment , Directive 2014/30 / EU , GD 487/2016 - on electromagnetic compatibility, updated,
we have certified the conformity of the product with the specified standards and we declare that
it complies with the main safety and security requirements, does not endanger life, health,
occupational safety and does not have a negative impact on the environment.
I, the undersigned Stroe Catalin, the manufacturer's representative, declare on his own
responsibility that the product complies with the following European standards and
directives :
•SR EN ISO 12100: 2011 - Car safety. Basic concepts, general design principles. Basic
terminology, methodology. Technical principles
•EN 809: 1998 + A1: 2009 + AC: 2010 - Security principles; Water pumps and pumps ;
•EN 60204-1: 2018 - Car electrical equipment - Part 1: General safety requirements ;
•EN 60335-1: 2012+ A13: 2017 - Household electrical appliances and similar purposes.
Security. Part 1: General requirements
•EN 60335-2-41: 2003 + A1: 2004 + A2: 2010 - Household electrical appliances and
similar purposes. Security. Specific requirements for pumps
•EN 62233:2008 + AC: 2008 - Measuring methods for the electromagnetic fields of
household appliances and similar apparatus for human exposure
•EN 60034-1: 2010 + AC: 2010 - Rotary electric machines. Part 1: Evaluation and
performance
•EN 55014-1: 2017 -Electromagnetic compatibility
•EN 55014-2: 2015 - Electromagnetic compatibility
•EN 61000-3-2: 2014 - Electromagnetic compatibility
•EN 61000-3-3: 2013 - Electromagnetic compatibility
•SR EN ISO 3744: 2011 - Acoustics. Determination of sound power levels emitted by
noise sources using sound pressure
Other Standards or specifications used :
•SR EN ISO 9001 - Quality Management System

19
•SR EN ISO 14001 - Environmental Management System
•OHSAS18001 - Occupational Health and Safety Management System.
Make and name of manufacturer: F.F.P.T. Co. Ltd.
Note: the technical documentation is owned by the manufacturer.
Specification: This declaration complies with the original.
Shelf life: 10 years from the date of approval.
Place and date of issue : Craiova, 20.05.2021
Year of affixing of the CE marking : 2021
Nr. inreg : 471 / 20.05.2021
Authorized person and signature : Eng. Stroe Marius Catalin
General Manager of
SC RURIS IMPEX SRL

20
DECLARATION OF CONFORMITY EC
Manufacturer: SC RURIS IMPEX SRL
Calea Severinului, no. 10, Bl. 317b, Craiova, Dolj, Romania
Goal. 0351 464 632, www.ruris.ro, info@ruris.ro
Authorized representative: eng. Stroe Marius Catalin - General Manager
Authorized person for the technical file: eng. Florea Nicolae - Production Design Director
Car description : Hydrophore with the role of pumping water from wells and drilled wells, to
valves with constant flow.
Serial number: from XXAqua2010S000 to XXAqua2010S9999 (Where xx represents the last
two digits of the year of manufacture)
Product: HIDROFOR
Model: RURIS Type: AquaPower 2010S
Absorbed power : 900W
Acoustic power level (relative) : 72 dB (A) Acoustic power level : 72 dB
The sound power level is certified by I.N.M.A Bucharest according to Test Bulletin no. 2 /
22.03.2018 in accordance with the provisions of Directive 2000/14 / EC and SR EN ISO 3744:
2011
We, SC RURIS IMPEX SRL Craiova as a manufacturer , in accordance with H.G. 1029/2008
- regarding the conditions for placing cars on the market, Directive 2006/42 / EC - safety and
security requirements, Standard EN ISO 12100: 2010 - Cars. Security, Directive 2000/14 /
EC amended by Directive 2005/88 / EC, H.G. 1756/2006 - on the limitation of the level of
noise emissions in the environment, Directive 2014/35 / EU, GD 409/2016 - on low voltage
equipment , Directive 2014/30 / EU , GD 487/2016 - on electromagnetic compatibility,
updated,we have certified the conformity of the product with the specified standards and we
declare that it complies with the main safety and security requirements, does not endanger
life, health, occupational safety and does not have a negative impact on the environment.
I, the undersigned Stroe Catalin, the manufacturer's representative, declare on his own
responsibility that the product complies with the following European standards and
directives :
•SR EN ISO 3744: 2011 - Acoustics. Determination of sound power levels emitted by
noise sources using sound pressure
Other Standards or specifications used :
•SR EN ISO 9001 - Quality Management System
•SR EN ISO 14001 - Environmental Management System
•OHSAS18001 - Occupational Health and Safety Management System.
Note: the technical documentation is owned by the manufacturer.
Specification: This declaration complies with the original.
Shelf life: 10 years from the date of approval.
Place and date of issue : Craiova, 20.05.2021
Year of affixing of the CE marking : 2021
Nr. inreg : 472 / 20.05.2021
Authorized person and signature : Eng. Stroe Marius Catalin
General Manager of
SC RURIS IMPEX SRL
Other manuals for AquaPower 1008S
1
This manual suits for next models
7
Table of contents
Popular Water System manuals by other brands

Phason
Phason Select Water manual

Continental Refrigerator
Continental Refrigerator AWS-10 instruction manual

Cooke
Cooke WaterWitch Product support guide

Miele professional
Miele professional UG 70-60/80 operating instructions

Everpure
Everpure Scalekleen EV9796-20 Specification sheet

FLOWMARK
FLOWMARK Mark-II-SC Installation & operation manual

TERRY
TERRY SM2 Specifications

Viqua
Viqua D4+ instruction sheet

dedalo
dedalo Easy-UV 4-8 Assembly and installation instructions

Everpure
Everpure Exubera EV9318-60 Specification sheet

flamco
flamco Airfix A Series Installation and operating instructions

Everpure
Everpure Single Head EV9272-19 Specification sheet