SafeTrust SABRE SA350 User manual

Install Guide
01
—
Introduction
02
—
In the box
03
—
Specifications
04
—
Installation
05
—
Disclaimer
SABRE INLINE/RELAY
www.safetrust.com Last Updated January 23, 2021

The
SABRE
is
available
as
an
INLINE
or
a
RELAY
device
.
Both
products
make
it
easy
to
upgrade
any
existing
access
control
system
with
mobile
access
,
without
giving
up
support
for
physical
access
cards
.
When
connected
between
a
host
reader
and
a
physical
access
control
panel
,
the
SABRE
enables
mobile
devices
and
wearables
to
be
used
as
a
replacement
or
in
-
conjunction
with
existing
card
technologies
.
The
SABRE
INLINE
and
the
SABRE
RELAY
sensors
contain
onboard
Wi
-
Fi
which
permits
two
-
way
communication
with
the
Credential
Manager
for
OTA
remote
management
and
configuration
.
The
SABRE
RELAY
is
an
extension
of
the
INLINE
device
with
additional
access
controller
management
capabilities
.
The
RELAY
is
ideally
suited
for
parking
garages
,
remote
buildings
and
single
door
offices
where
no
existing
cabling
or
reader
infrastructure
exists
.
If
you
order
the
SABRE
INLINE
it
will
come
without
the
relay
section
of
the
board
.
Introduction
a
)
INLINE
or
RELAY
Sensor
SABRE
INLINE
/
RELAY
Quick
Start
Guide
| 2
In the box
01
Product Overview
02
Included
b
)
Wiring
c
)
7
1
/
8
in
Solid
and
Stranded
Wire
Stripper
d
)
Insulation
Displacement
Connector
,
Moisture
Resistant
,
300
V
Max
e
)
Screwdriver
Not Included (Required)
a
)
b
)
c
)
d
)
e
)
www
.
safetrust
.
com

SABRE
INLINE
/
RELAY
Quick
Start
Guide
| 3
Specifications 03
USB
,
Optical
Relay
400mA
,
External
48V
5A
relay
Ports
Hardware
Bluetooth
Low
Energy
2
.
400
GHz
-
2
.
4835
GHz
MQTT
(
ISO
/
IEC
PRF
20922
)
IoT Protocol
Mobile Operating Systems
Apple
iOS
9
.
0
or
later
and
Android
4
.
4
or
later
on
devices
with
the
Safetrust
Wallet
65mm
x
30mm
x
12mm
Dimensions
5
-
12
V
DC
Power Requirements
Output
Form
C
relay
,
Wiegand
,
RS
-
485
,
OSDP
v1
/
v2
,
OSDP
v2
Secure
Channel
,
TTL
5V
Wi
-
Fi
2
-
50
mA
,
BLE
2
-
15
mA
Power Consumption
FCC
Part
15
Modular
Transmitter
Certification
,
Canada
IC
,
EU
EMC
CE
,
India
ETA
-
WPC
,
RCM
,
RoHS
.
WEEE
Certifications
Mobile Credential Emulations
Most
popular
125kHz
prox
formats
from
HID
®,
Indala
®,
AWID
®,
GE
Casi
®,
Farpointe
and
Honeywell
®,
MIFARE
®
Classic
,
MIFARE
®
DESFire
®
and
Seos
®
Credentials
www
.
safetrust
.
com

1 —
Ground
2 —
Data1
3 —
Data0
4 —
5
V
Out
5 —
Green
LED
6 —
Buzzer
7 —
TTL
Trig
Out
8 —
RS
-
485
A
9 —
RS
-
485
B
10 —
12V
8 —
12V
7 —
Green
LED
6 —
Red
LED
5 —
Data0
RS
-
485
A
4 —
Data1
RS
-
485
B
3 —
Other
Out
2 —
Buzzer
1 —
Ground
10 —
Relay
5v
Out
Ext
9 —
Relay
5v
In
Ext
8 —
Relay
5v
In2
Ext
7 —
Relay
In
6 —
Normally
Closed
5 —
Common
4 —
Normally
Open
3 —
Ground
2 —
Relay
Out
1 —
12V
SABRE
INLINE
/
RELAY
Quick
Start
Guide
| 4
Installation 04
Panel
Connector
-
Supports
pass
through
Wiegand
or
translates
Wiegand
to
RS
-
485
(
OSDP
).
Includes
supplemental
I
/
O
for
special
applications
.
Reader
Connector
-
Wires
into
a
legacy
reader
providing
pass
through
Wiegand
,
LEDs
and
buzzer
.
Supplemental
trigger
output
.
Relay
Connector
(
Relay
version
) -
Offers
a
Form
C
relay
and
solid
state
relay
I
/
O
.
Perfect
for
parking
gates
and
other
custom
aplications
.
Step 1: Wire your INLINE or
RELAY device
Note:
This
guide
assumes
you
have
already
created
an
Identity
System
within
the
Credential
Manager
platform
and
assigned
credentials
to
that
system
.
If
you
have
not
done
so
,
please
refer
to
the
Safetrust
Onboarding
Guide
before
completing
the
sensor
installation
.
www
.
safetrust
.
com
Form C Socket
BLE Ext Antenna Input
Micro-USB
WiFi Ext Antenna
Electrical Installation and Disclaimer
Please
consult
your
local
jurisdiction
to
determine
what
licenses
are
required
to
install
or
modify
a
low
voltage
electrical
access
control
and
alarm
system
.
Instructions
in
this
document
do
not
provide
authority
or
endorsement
to
install
this
device
if
you
are
not
authorized
to
do
so
in
accordance
with
the
laws
in
which
the
device
will
be
installed
.
RS-485 Termination
The
device
is
self
terminating
,
however
over
long
cable
runs
and
in
multi
-
drop
lines
it
maybe
necessary
to
provide
additional
termination
.
Please
consult
the
RS
-
485
(
EIA
/
TIA
-
485
-
A
)
specification
if
you
notice
noise
or
instability
in
your
installation
for
information
on
correct
termination
procedures
.
Please
note
that
this
device
operates
at
3
.
3v
and
may
be
configured
to
operate
at
the
higher
end
of
the
RS
-
485
specification
of
5v
.
5v
provides
greater
reliability
over
longer
distances
,
however
most
access
control
peripherals
operate
at
the
lower
end
of
3
.
3v
and
as
such
,
please
consult
with
your
panel
manufacturer
for
permitted
line
voltage
levels
.
In
most
cases
panels
are
compliant
with
RS
-
485
and
accept
the
range
2
.
5
-
5v
.

SABRE
INLINE
/
RELAY
Quick
Start
Guide
| 5
Standard Wiegand Wiring
www
.
safetrust
.
com
For
pass
through
Wiegand
,
connect
the
Wiegand
wires
from
the
reader
to
the
'
Data
0
RS
-
485
A
'
and
'
Data
1
RS
-
485
B
'
connections
on
the
reader
connector
of
the
Inline
/
Relay
,
and
connect
the
'
Data
0
'
and
'
Data
1
'
outputs
from
the
panel
connector
to
the
Wiegand
input
on
the
panel
.
For
Wiegand
translated
to
RS
-
485
(
OSDP
),
connect
the
wires
the
same
way
as
above
between
the
reader
and
the
Inline
/
Relay
,
and
connect
the
'
RS
-
485
A
'
and
'
RS
-
485
B
'
outputs
from
the
panel
connector
to
the
RS
-
485
/
OSDP
input
on
the
panel
.
Form C Socket
OSDP Wiring

Select
the
Manage Sensor
tab
from
the
navigation
on
the
left
hand
side
.
SABRE
INLINE
/
RELAY
Quick
Start
Guide
| 6
www
.
safetrust
.
com
Form C Socket
Setup:
•
Open
your
Safetrust
Wallet
App
or
download
it
from
the
App
Store
or
Google
Play
if
you
haven
'
t
already
.
•
Login
with
Google
Sign
-
In
or
with
the
username
and
password
that
you
set
your
Safetrust
account
up
with
.
The
Safetrust
Wallet
App
communicates
with
the
sensor
via
Bluetooth
and
configures
the
sensor
for
an
Identity
System
.
Step 2: Open the Safetrust
Wallet
Once
the
sensor
is
highlighted
,
click
CONFIGURE
from
the
bottom
options
.
Step 3: Choose a sensor
to manage
With
the
Manage Sensor
tab
open
,
bring
the
phone
in
range
of
the
SABRE
and
once
visible
from
the
App
,
click
on
the
sensor
.
Note: You may need to click the refresh button in
the top right hand corner.

SABRE
INLINE
/
RELAY
Quick
Start
Guide
| 7
www
.
safetrust
.
com
Step 4: Input sensor
information
The
settings
show
a
range
of
configuration
options
for
the
sensor
,
however
the
following
fields
are
the
main
settings
that
require
action
at
this
time
.
Setup:
•
Choose
an
Identity System
.
•
Specify
the
Type
of
access
from
the
dropdown
(
eg
.
Door
,
Gate
etc
.)
•
Assign
a
short
Name
and
Description
using
alphanumeric
characters
.
•
Choose
an
Output
for
the
sensor
(
the
default
is
set
to
Wiegand
).
Once
you
have
adjusted
all
the
configuration
settings
,
scroll
to
the
bottom
of
the
page
and
click
SUBMIT
to
successfully
complete
the
sensor
configuration
.
If
the
Output
is
set
to
OSDP
,
select
the
Serial Baudrate
and
set
the
Device ID
to
match
the
settings
of
the
access
control
panel
.
OSDP Output:

SABRE
INLINE
/
RELAY
Quick
Start
Guide
| 8
www
.
safetrust
.
com
Set
the
Activation
Distance
for
your
sensor
between
touch
and
50
ft
(
15m
).
The
distance
will
automatically
be
set
to
30cm
,
meaning
a
user
needs
to
be
within
30cm
in
order
to
"
Auto
Authenticate
"
to
the
reader
.
Optional: Activation Distance
The
Anti
-
Passback
setting
defines
the
number
of
seconds
between
each
attempt
to
resend
a
mobile
credential
.
Anti
-
Passback
can
be
used
to
prevent
users
from
passing
their
credential
back
for
another
user
to
borrow
and
to
stop
users
entering
an
area
by
simply
following
or
tailgating
another
user
.
Optional: Anti-passback
When
the
SABRE
information
is
saved
successfully
to
Credential
Manager
and
assigned
to
the
Identity
System
,
the
new
description
will
appear
in
the
Manage
Sensor
tab
with
a
unique
serial
number
assigned
.
Step 5: Configuration
complete!
Getting Access:
•
To
open
the
door
,
simply
present
your
mobile
device
running
the
Safetrust
Wallet
application
to
the
reader
.
•
When
the
phone
is
within
the
configured
activation
range
,
the
LED
on
the
assigned
credential
for
this
sensor
will
turn
yellow
.
•
If
“
Auto
Authenticate
”
is
enabled
for
the
mobile
credential
,
the
credential
will
be
sent
to
the
SABRE
whenever
the
mobile
device
is
within
the
activation
zone
.

SABRE
INLINE
/
RELAY
Quick
Start
Guide
| 9
www
.
safetrust
.
com
Note
:
This
equipment
has
been
tested
and
found
to
comply
with
the
limits
for
a
Class
B
digital
device
,
pursuant
to
part
15
of
the
FCC
Rules
.
These
limits
are
designed
to
provide
reasonable
protection
against
harmful
interference
in
a
residential
installation
.
This
equipment
generates
,
uses
and
can
radiate
radio
frequency
energy
and
,
if
not
installed
and
used
in
accordance
with
the
instructions
,
may
cause
harmful
interference
to
radio
communications
.
However
,
there
is
no
guarantee
that
interference
will
not
occur
in
a
particular
installation
.
If
this
equipment
does
cause
harmful
interference
to
radio
or
television
reception
,
which
can
be
determined
by
turning
the
equipment
off
and
on
,
the
user
is
encouraged
to
try
to
correct
the
interference
by
one
or
more
of
the
following
measures
:
—
Reorient
or
relocate
the
receiving
antenna
.
—
Increase
the
separation
between
the
equipment
and
receiver
.
—
Connect
the
equipment
into
an
outlet
on
a
circuit
different
from
that
to
which
the
receiver
is
connected
.
—
Consult
the
dealer
or
an
experienced
radio
/
TV
technician
for
help
.
RF
Exposure
:
Mobile
RF
exposure
device
,
there
shall
be
a
minimum
separation
of
20
cm
between
the
device
and
any
users
or
installers
.
Canada
Radio
Certification
:
This
device
complies
with
Industry
Canada
license
-
exempt
RSS
standard
(
s
).
Operation
is
subject
to
the
following
two
conditions
: (
1
)
this
device
may
not
cause
interference
,
and
(
2
)
this
device
must
accept
any
interference
,
including
interference
that
may
cause
undesired
operation
of
the
device
.
Safetrust
,
SABRE
MODULE
,
and
Safetrust
Wallet
are
all
trademarks
of
Safetrust
Inc
.
All
other
product
and
company
names
are
trademarks
of
their
respective
holders
;
use
of
these
trademarks
does
not
imply
any
affiliation
with
or
endorsement
by
their
holders
.
All
claims
of
compatibility
are
made
by
Safetrust
only
. *
HID
®,
iCLASS
SE
®,
Seos
®,
multiCLASS
SE
®,
and
Indala
®
are
trademarks
of
HID
Global
Corporation
/
ASSA
ABLOY
AB
.
Neither
that
company
nor
its
affiliates
have
manufactured
or
endorsed
this
product
and
have
no
association
to
Safetrust
Inc
.
05
Disclaimers

Safetrust
Quickstart
Guide
| 10
www
.
safetrust
.
com
Safetrust
delivers
a
touchless
access
experience
that
makes
the
new
workplace
secure
,
healthier
and
convenient
.
Using
virtual
credentials
stored
in
your
mobile
phone
or
wearable
,
Safetrust
enables
employees
to
move
seamlessly
through
secured
doors
,
elevators
,
turnstiles
and
more
.
Safetrust
eliminates
the
need
to
replace
your
existing
readers
by
leveraging
your
existing
infrastructure
,
providing
a
fast
,
cost
-
effective
,
and
convenient
upgrade
path
to
touchless
virtual
credentials
.
Safetrust
is
headquartered
in
Fremont
,
California
.
Want to Learn More?
Contact sales@safetrust.com
Other manuals for SABRE SA350
1
This manual suits for next models
3
Other SafeTrust Relay manuals