Introduction 1. Serial connector
2. Power supply
Wiring Centre Description
Product Compliance
Technical Information
The KL04RF module is an extension to the KL08RF wiring centre for an additional 4 heating zones.Works
only in combination with KL08RF wiring centre and increases its functionality up to 12 individual heating
zones.
It is used for communication between KL08RF wiring centre and KL04RF extension module. Combined
set increases support up to 12 zones.
KL04RF
This product complies with the essential requirements and other relevant provisions of the following
EU Directives: EMC 2014/30/EU, Low Voltage Directive LVD 2014/35/EU, Radio directive 2014/53/EU
and RoHS directive 2011/65/EU. The full text of the EU Declaration of Conformity is available at the
following internet address: www.saluslegal.com
Use in accordance with national and EU regulations. Device is intended for indoor use only in dry
conditions. Product for indoor use only. Installation must be carried out by a qualied person in
accordance to national and EU regulations.
Before attempting to setup and install, make sure that KL04RF is not connected to any power source.
Installation must be carried out by a qualied person. Incorrect installation may cause damage to the
wiring centre. The KL04RF should not be installed in areas where it may be exposed to water or damp
conditions.
Safety Informations
Manual
Wiring centre extension for KL08RF
Model: KL04RF
1. Serial Connector
2. Power Supply
3. Connection diode
4. Power supply diode
5. Work status indication of each zone
6. Output terminals for actuators
230 V AC
L
N
Power supply for wiring centre is 230V ~, 50Hz.
Features of the installation:
• two-wire, with PE protective conductor,
• made in accordance with applicable regulations.
Power Supply 230 V AC
Max load 3 A
Outputs Thermoelectric actuator 230V AC
Dimensions [mm] 163 x 85 x 67
IX 2018
910 11 12
13 4 5
2
6
910 11 12
910 11 12
110 mm
12 mm
6. Output terminals for actuators
INSTALLATION
Wires of the thermoelectric actuators should be plugged into the self-locking connectors in the
appropriate zones. You can connect 3 actuators directly to one zone. The current load of one zone is
adapted to operate with up to 6 thermoelectric actuators with a power of 2 Watts. If there is a need to
connect more than 6 actuators please use an additional relay to relieve the output of the zone.
Note: On the actuator contacts,
there is voltage 230 V AC during
their work.
Remove the top cover of the KL04RF. Connect the thermoelectric actuators wires.
Connect KL08RF and KL04RF using serial connector.
Make sure that all the wires are properly connected, mount top cover and power up the wiring
centre -“Power”and “Connection”red LED diodes will light up indicating the correct connection
with the KL08RF wiring centre.
Mount the back side of the housing to the wall.
When mounting on a DIN rail, open the hooks on the back of the housing.
Thread the power supply wires through and connect them to the“L”and “N” terminals.
Remove the appropriate piece
of insulation from the wires.
1
2
4
6
5
7
3
KL04RF power supply
(min. 2x1,0 mm2230 V
max. 2x1,5mm2230 V)
The operation was explained on the example
of T30NC actuators.
4. Power supply diode
5. Work status indication of each zone
3. Connection diode
Green led diode lights up when the heating demand signal is being transmitted from the thermostat
to the given zone (with NC actuators connected).
If KL04RF module is properly connected to the KL08RF wiring centre, connection diode will
light solid red.
After connecting the KL04RF module to the power supply, Power led diode will light solid red.
0
O
1234
Reset
KL08NSB KL04NSB
0
O
1234
Reset
KL08NSB KL04NSB
910 11 12

Popular Extender manuals by other brands

Monnit MUG11 user guide

Monnit

Monnit MUG11 user guide

Comprehensive CHE-HDBT255U user manual

Comprehensive

Comprehensive CHE-HDBT255U user manual

Black Box ServSwitch ACS235A manual

Black Box

Black Box ServSwitch ACS235A manual

z21 XL BOOSTER user manual

z21

z21 XL BOOSTER user manual

DP Pumps Hydro-Unit Utility Line F Installation & operating manual

DP Pumps

DP Pumps Hydro-Unit Utility Line F Installation & operating manual

Purpose PAV-EX40-HDR-ARC-AE instruction manual

Purpose

Purpose PAV-EX40-HDR-ARC-AE instruction manual

StarTech.com SV565FXDUSA user guide

StarTech.com

StarTech.com SV565FXDUSA user guide

Techly IDATA EXTIP-373 user manual

Techly

Techly IDATA EXTIP-373 user manual

PULSEEIGHT HDBaseT Lite Quick setup guide

PULSEEIGHT

PULSEEIGHT HDBaseT Lite Quick setup guide

SMART-AVI USB2Mini user manual

SMART-AVI

SMART-AVI USB2Mini user manual

Tripp Lite B130-101-2 manual 

Tripp Lite

Tripp Lite B130-101-2 manual 

Black Box ServSwitch ACX310F user manual

Black Box

Black Box ServSwitch ACX310F user manual

Dwarf Connection DC-LINK-CLR2 manual

Dwarf Connection

Dwarf Connection DC-LINK-CLR2 manual

SMART-AVI USBXpress USB-TX050 user manual

SMART-AVI

SMART-AVI USBXpress USB-TX050 user manual

D-Link DHP-W311AV user manual

D-Link

D-Link DHP-W311AV user manual

Black Box LB304A user manual

Black Box

Black Box LB304A user manual

Zcom R1 Extender Quick installation guide

Zcom

Zcom R1 Extender Quick installation guide

Smarte SDS troubleshooting guide

Smarte

Smarte SDS troubleshooting guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.