Quick Start Guide
Smart Relay – Low Voltage (SC824ZB)
Read these instructions carefully before installing and
using the Smart Relay – Low Voltage and keep this guide
in a safe place for future reference.
• Verify compatibility with your associated
connected home system before installation.
• Follow all instructions provided by your connected
home manufacturer regarding the addition of
devices to your connected home system. An
authorized, qualified installer may be required.
• Follow all applicable codes and regulations in the
municipality where this product is installed.
Salus accepts no responsibility for damage caused by not
following these instructions.
Smart Relay - Low Voltage
NOTE:
Additional equipment may be required to address
radio communication issues due to building
construction or materials, or other radio interference.
INSTALLATION INSTRUCTIONS:
• Remove the assembly from the carton.
• Remove the front cover by lifting from the bottom.
• Position the relay in the desired location.
If anchors are required:
• Mark the locations of the screws.
• Drill 3/16” holes.
• Insert the anchors (provided)
• Position the relay over the anchors.
• Secure with 2 mounting screws (provided).
• Wire relay as desired. See options below. Remove
knockout on bottom side panel if required.
• Secure cables with the strain relief.
• Replace the front cover.
• Remove the assembly from the carton.
• Remove the front cover by lifting from the bottom.
• Remove the Relay Retainer by lifting the corners.
• Wire relay as desired. See options below.
• Remove white/blank backing from adhesive
(provided).
• Apply adhesive to bottom half of relay back.
• Remove red lettered backing from adhesive.
• Press back of relay onto the surface to be attached.
WIRING OPTIONS:
DRY CONTACT CONNECTIONS:
• Power In to terminal R
• Power Return to terminal C
• Load Out to terminal OUT
• Load Common to terminal COM
POWER SWITCH CONNECTIONS:
• Power In to terminal R
• Power Return to terminal C
• Load Out to terminal OUT
• Load Common to the open terminal C
• Add a wire between the open terminal R and COM
OUT COM R R C C
18-30 VAC
LOAD OUT
LOAD COMMON
POWER IN
POWER RETURN
OUT COM R R C C
18-30 VAC
LOAD OUT
LOAD COMMON
POWER IN
POWER RETURN