manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Salus
  6. •
  7. Relay
  8. •
  9. Salus RM-16A User manual

Salus RM-16A User manual

Other Salus Relay manuals

Salus SC824ZB User manual

Salus

Salus SC824ZB User manual

Salus SR600 User manual

Salus

Salus SR600 User manual

Popular Relay manuals by other brands

Woodward BU1-DC2 manual

Woodward

Woodward BU1-DC2 manual

ABB SSR32 product manual

ABB

ABB SSR32 product manual

Siemens SIRIUS 3UG4633 operating instructions

Siemens

Siemens SIRIUS 3UG4633 operating instructions

Siemens SIRIUS 3TK2824 A.20 Series Original operating instructions

Siemens

Siemens SIRIUS 3TK2824 A.20 Series Original operating instructions

Shelly Pro Series user manual

Shelly

Shelly Pro Series user manual

GE MVAX 11 Technical manual

GE

GE MVAX 11 Technical manual

ABB RELION REF615R manual

ABB

ABB RELION REF615R manual

Kemo Electronic B197 quick guide

Kemo Electronic

Kemo Electronic B197 quick guide

Seg MRM3 manual

Seg

Seg MRM3 manual

Basler BE1-700C manual

Basler

Basler BE1-700C manual

CD Automation REVEX 2PH 280A user manual

CD Automation

CD Automation REVEX 2PH 280A user manual

ABB SPAJ 142 C User manual and technical description

ABB

ABB SPAJ 142 C User manual and technical description

Ruelco 1S04 Operation manual

Ruelco

Ruelco 1S04 Operation manual

Basler V3E Z1P B2C1F instruction manual

Basler

Basler V3E Z1P B2C1F instruction manual

GE DGP instruction manual

GE

GE DGP instruction manual

Kyongbo Electronics GDR-D01 user manual

Kyongbo Electronics

Kyongbo Electronics GDR-D01 user manual

Eaton easyE4 series Application note

Eaton

Eaton easyE4 series Application note

Siemens BD2-AK03X/FS Series installation instructions

Siemens

Siemens BD2-AK03X/FS Series installation instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

www.salus-controls.eu
Relay module
RM-16A
SALUS distributor:
OL Controls Sp. z o.o. Sp. k.
43-262 Kobielice, 4 Rolna St.
tel: +48 32 700 74 53,
e-mail: salus@salus-controls.pl, www.salus-controls.eu
The declaration of compliance is on www.salus-controls.pl site
Relay module SALUS Controls
RM-16A
Symbol meaning selecting electric
electronic gear. Putting used gear with
other waste products is strictly forbid-
den. The declaration of compliance is on
www.salus-controls.pl site
Made in Poland
mounting in
a box Ø60
mounting only
inside buldings
Made in Poland
Relay module SALUS Controls
Product code: RM-16A
Relay module RM-16A opens and closes the circuit in order to aect the work of other devices. Some uses
of the module RM-16A with other Salus products are shown below:
1. Connection of the thermostat with the high voltage relay 230V (e.g. VS30/RT200/ERT20/ERT30/ERT50/
VS10) with a gas boiler which requires free-voltage output NO/COM or NC/COM
2. Connection of the SALUS temperature regulator with the NO/COM relay (e.g. 091FL) with the boiler con-
trol which requires NC/COM output (NC/COM output is normally required in the solid fuel boiler controls )
3. Connection of the receiver transmitting power higher than it is allowed by the relay in a regulator. The
maximum electricity consumption of the receiver cannot exeed 16A
4. Connection of the devices other than electro thermal actuators with the wiring centre ( KL06-M/
KL08NSB /KL08RF/KL10/KL10RF) e.g. if you want to connect a pump or an electric heating mat instead
of a electro thermal actuator.
Before connecting the relay module with a dierent device make sure that its parame-
ters are consistent with the RM-16A module specication. Incorrect connection may
cause undesirable action, excessive overheating and combustion hazard. To avert the
hazard make sure that the relay module RM-16A is correctly connected. The connection
of the device can be done only by a qualied installer who has up-to-date eligibility.
SL
N
L
NO
COM
NOCOM
VOLTAGE
FREE
INPUT
NC
μ 16
A
/
250
V
AC
4000 VA
RM-16A
INPUT
230
V
AC
POWER SUPPLY
230
V
AC / 50 Hz
SAFETY INFORMATION VISUAL ASPECT
Power: 16A / 250V AC, 4000VA
INPUT NO/COM: Connection of a regulator with the free
voltage relay NO/COM
OUTPUT NC/COM/NO: Output receiver
INPUT SL: Connection of the regulator with the
voltage relay 230V
POWER SUPPLY N/L: Power of 230V AC/50Hz
Measurements: 47x47x21
relay output (NO, COM, NC)
INTRODUCTION
Relay module RM-16A opens and closes the circuit in order to aect the work of other
devices. Some uses of the module RM-16A with other Salus products are shown below:
1. Connection of the thermostat with the voltage relay 230V (e.g. VS30/RT200/ERT20/
ERT30/ERT50/VS10) with a gas-red boiler which requires free-voltage output NO/COM
or NC/COM
2. Connection of the SALUS thermostat with the NO/COM relay (e.g. 091FL) with the
boiler control which needs NC/COM output (NC/COM output is normally required in
the solid fuel boiler controls)
3. Connection of the receiver transmitting power higher than it is allowed by the relay
in a regulator. The maximum electricity consumption of the receiver cannot exeed 16A
4. Connection of the devices other than electro thermal actuators with the wiring
centre ( KL06-M/KL08NSB /KL08RF/KL10/KL10RF) e.g. if you want to connect a pump or
an electric heating mat instead of a electro thermal actuator.
PRODUCT SPECIFICATION
Power supply of the modul RM-16A-230V AC
Control input with the voltage output 230V
Control input with free-voltage output
LED signalling short circuitof the relay output
1. Connection of the thermostat with a voltage relay 230V (e.g. VS30/RT200/ERT20/ERT30/
ERT50/VS10) to a gas boiler which requires free-voltage output NO/COM.
CONNECTION DIAGRAMS
2. Connection of the SALUS temperature regulator with NO/COM relay (e.g. 091FL) with a
boiler control which requires NC/COM output ( NC/COM output is normally required in solid
fuel boilers controls).
CONNECTION DIAGRAMS
A boiler with a free-A boiler with a free-
-voltage relay-voltage relay
ermostat 230Vermostat 230V
ermostat with aermostat with a
free-voltage relayfree-voltage relay
A boiler with NC/A boiler with NC/
COM inputCOM input
CONNECTION DIAGRAMS CONNECTION DIAGRAMS
3. Connection of the receiver transmitting power higher than it is allowed by the relay in a
regulator. The maximuml electricity consumption of the receiver cannot exeed 16A
4. Connection of the devices other than electro thermal actuators with the wiring centre (
KL06-M / KL08NSB / KL08RF / KL10 / KL10RF) e.g. if you want to connect a pump or an electric
heating mat instead of a electro thermal actuator.
A ermostat with aA ermostat with a
free-voltage relayfree-voltage relay
A thermostat with aA thermostat with a
high voltage relayhigh voltage relay
Heating mat max.16AHeating mat max.16A
Wiring centre: KL06-M / KL08NSB / KL08RF / KL10 / KL10RFWiring centre: KL06-M / KL08NSB / KL08RF / KL10 / KL10RF
PowerPower
SupplySupply
и т. д.и т. д.
Pump -> max 16AmpsPump -> max 16Amps
oror
Heating mat -> maxHeating mat -> max
16Amps16Amps
oror
Actuators -> max 16 AmpsActuators -> max 16 Amps
zone 1zone 1 zone 2zone 2 zone 3zone 3 etcetc
max.16Amax.16A