manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Saniswiss
  6. •
  7. Accessories
  8. •
  9. Saniswiss SANIPOD User manual

Saniswiss SANIPOD User manual

USER-MANUAL
SANIPOD
PR ESE NTATI ON
1. LED LIGHTS 6 MOVEMENTS HAND SANITIZING
2. RED OPENING INDICATOR
3. COVER
4. BODY
5. PRODUCT DISTRIBUTION AREA
6. GREY OPENING INDICATOR
7. SANISWISS LOGO
8. HOLE FOR HANGING SCREWS
9. LED BEAM
10. THANK ROOM FOR 800ML POUCH
11. BATTERIES
2
1
6
CHARACTERISTICS
BAT TERIES 4 C-CELL BATTERIES
PROVIDE 30’000 USES
INTENSITY 1,5 A
POUCH CAPACITY 800 mL
WEIGHT 2,3 kg
SIZE W 28 x H 29,54 x L 15,9 cm
SANITIZER HANDS H1
800 ML POUCH | REF 132151
SANISWISS SANIPOD | REF 132184
PERFORMANCES
BATTERY LIFE ± 30’000 uses *
DOSE MEASUREMENT 0,8 mL - 1,0 mL
8
10
11
5
PRECAUTIONS
The manufacturer will not be held liable for any bodily harm
or material damages caused by inappropriate or abnormal
use of the devise contrary to the precautions recommended
in the list below (non exhaustive list) :
- Only use Saniswiss Sanipod with our Sanitizer Hands H1
800ml REF 132151.
- Make sure to use adapted batteries.
- Avoid moving Saniswiss Sanipod when it contains the
solution.
- Remove the pouch and batteries from the Saniswiss
Sanipod for transport.
- Make sure the Sanipod is placed at a suitable height for
Hand Hygiene (1.30 metres from the floor )
- Do not insert any object or fluid except Sanitizer Hands H1
800ml behind the cover.
- In case of contact with eyes, rinse immediately with plenty
of water. If eye irritation persists: seek medical attention.
- Please read the instructions for use of our Sanitizer Hands
H1 REF 132151 before inserting the pouch.
4
3
7
9
28 cm
15,9 cm
29,54 cm
1, 30 m
* Depending on the type and the brand of battery
SANISWISS SA |SANISWISS.COM |INFO@SANISWISS.COM
ROUTE DE FRONTENEX 41A | 1207 GENÈVE | SWITZERLAND | +41 22 718 75 75
© 2021 All rights reserved
UMS11102021EN
USE
1●Use the enclosed pattern and mark the desired spots
with the help of a pencil. (We advise you to drill the highest
holes at 1,30m from the ground)
2●Drill the holes with a drill and install the wall fittings
If necessary, use a spirit level to check the horizontal level.
3●Remove the cover of the automatic dispenser
●Attach the back of the Sanipod to the wall with the
screws provided.
4●Install 4 batteries inside the Sanipod.
5●Insert the 800 ml pouch into the Sanipod.
a) Clip the yellow connector to its corresponding end
b) Lift the grey end of the pouch
c) Lift the green lever to lock the pouch.
The Sanitizer H1 pouch can deliver up to 880 uses.
● Close the cover of the Sanipod
6●After 880 uses, a red light will be projected on the wall to
indicate that the bag is (almost) empty and that it is needs
to be changed.
> If a problem appears, then disconnect the device
and consult your retailer.
MAINTENANCE
The device must be kept in a dry and clean place remote
from any possible projections. Clean and remove gel that
could stick in the Sanipod distributor.
MALFUNCTIONNING
The device does not start :
- Check the batteries.
- Check if the 800 ml pouch is full and properly placed.
- Check if the cover (3) has been closed properly.
The device works but does not use product :
- Check if the 800 ml pouch is full.
- Check if the device is clean and not blocked by gel.
- Please check that the cover is properly closed.
WARRANTY
A copy of the certificate of guarantee or invoice of the
Sanipod must be kept by the customer; it shall be presented
to the retailer or to Saniswiss SA, Route de Frontenex 41A,
1207 Geneva, Switzerland, to attest the guarantee, the other
copy shall be kept by the retailer.
CL AUSES
What follows is not exclusive of the legal guarantee foreseen
and following ones of the civil code concerning hidden
defects.
OBJECTS
The guarantee consists of the free supply of the parts that
are considered defective by our technical services, the
exchanged parts becomes the property of the company.
Repairs required after wrong operations, abnormal uses,
carelessness or excess loads of the device as well as
those required because of variations of the electricity
network, voltage surges or defective installations, etc. can
not be guaranteed. Also the guarantee nullifies in case of
intervention and repair by qualified technician not member of
Saniswiss SA. The seals of the device have to be untouched.
Besides, if an abnormal corrosion of parts was noticed
indicating the use of another product than REF 132151, the
guarantee would be also void.
TRANSPORTATION
The material travels under the responsibility of the user. In
case of damages during the transportation, the addressee
has to make any reserves to the carrier before taking delivery
of the device.
DURATION
Saniswiss Sanipod is guaranteed during a period of 2
years as from the day of the reception of the device by
the user.
In case of doubts reading the user-manual,
please contact our support specialist at
Saniswiss SA t +41 22 718 75 75
SANISWISS SA |SANISWISS.COM |INFO@SANISWISS.COM
ROUTE DE FRONTENEX 41A | 1207 GENÈVE | SWITZERLAND | +41 22 718 75 75
12
34
56
GENERAL
DISPENSER TYPE
NAME : Saniswiss Sanipod
PROTECTION CLASS : IP10
OPERATION TEMPERATURE: 10°C à 40°C
STORAGE TEMPERATURE: 10°C à 50°C
OPERATION AND STORAGE HUMIDITY : 25% à 75%
POWER CLASSIFICATION: classe 1
PRECAUTION
Do not use in presence of a flammable anesthetic
mixture intermittent.
1,30M

Popular Accessories manuals by other brands

Hubbell Gear Drive Electric Cable Reels SM-24 Installation and maintenance instructions

Hubbell

Hubbell Gear Drive Electric Cable Reels SM-24 Installation and maintenance instructions

Panamax MIW-POWER AV manual

Panamax

Panamax MIW-POWER AV manual

A&D Weighing Indicator AD-4405 instruction manual

A&D

A&D Weighing Indicator AD-4405 instruction manual

MyCharge EasyNote TE user manual

MyCharge

MyCharge EasyNote TE user manual

Siemens QSA2700D Basic documentation

Siemens

Siemens QSA2700D Basic documentation

Axminster Tooling Stylus Tip Ballpoint Pen Kit instruction manual

Axminster

Axminster Tooling Stylus Tip Ballpoint Pen Kit instruction manual

Telldus 15261 user manual

Telldus

Telldus 15261 user manual

Dometic CFX3 Series Short Operating Manual

Dometic

Dometic CFX3 Series Short Operating Manual

Apogee Instruments SQ-612 owner's manual

Apogee Instruments

Apogee Instruments SQ-612 owner's manual

Pyle PPBCM28 instruction manual

Pyle

Pyle PPBCM28 instruction manual

Osmio Sanser user manual

Osmio

Osmio Sanser user manual

Electro-Sensors FB420 manual

Electro-Sensors

Electro-Sensors FB420 manual

MKS 943 Series instruction manual

MKS

MKS 943 Series instruction manual

NeuLog NUL-216 Guide

NeuLog

NeuLog NUL-216 Guide

ELRO LP152011 manual

ELRO

ELRO LP152011 manual

Blyss 21217KF Safety guide

Blyss

Blyss 21217KF Safety guide

Opticon EBS-30 Specification manual

Opticon

Opticon EBS-30 Specification manual

Centralite 3-Series Product data sheet

Centralite

Centralite 3-Series Product data sheet

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.