manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Santacary
  6. •
  7. Measuring Instrument
  8. •
  9. Santacary iU2-C User manual

Santacary iU2-C User manual

Other Santacary Measuring Instrument manuals

Santacary iU2 User manual

Santacary

Santacary iU2 User manual

Santacary iP2 PM2.5 User manual

Santacary

Santacary iP2 PM2.5 User manual

Santacary BE500 User manual

Santacary

Santacary BE500 User manual

Santacary S2 User manual

Santacary

Santacary S2 User manual

Santacary XAR-UC User manual

Santacary

Santacary XAR-UC User manual

Santacary iU2 User manual

Santacary

Santacary iU2 User manual

Popular Measuring Instrument manuals by other brands

Powerfix Profi 278296 Operation and safety notes

Powerfix Profi

Powerfix Profi 278296 Operation and safety notes

Test Equipment Depot GVT-427B user manual

Test Equipment Depot

Test Equipment Depot GVT-427B user manual

Fieldpiece ACH Operator's manual

Fieldpiece

Fieldpiece ACH Operator's manual

FLYSURFER VIRON3 user manual

FLYSURFER

FLYSURFER VIRON3 user manual

GMW TG uni 1 operating manual

GMW

GMW TG uni 1 operating manual

Downeaster Wind & Weather Medallion Series instruction manual

Downeaster

Downeaster Wind & Weather Medallion Series instruction manual

Hanna Instruments HI96725C instruction manual

Hanna Instruments

Hanna Instruments HI96725C instruction manual

Nokeval KMR260 quick guide

Nokeval

Nokeval KMR260 quick guide

HOKUYO AUTOMATIC UBG-05LN instruction manual

HOKUYO AUTOMATIC

HOKUYO AUTOMATIC UBG-05LN instruction manual

Fluke 96000 Series Operator's manual

Fluke

Fluke 96000 Series Operator's manual

Test Products International SP565 user manual

Test Products International

Test Products International SP565 user manual

General Sleep Zmachine Insight+ DT-200 Service manual

General Sleep

General Sleep Zmachine Insight+ DT-200 Service manual

Sensa Core Lacto Spark user manual

Sensa Core

Sensa Core Lacto Spark user manual

VOLTCRAFT UTS-1980 operating instructions

VOLTCRAFT

VOLTCRAFT UTS-1980 operating instructions

EBCHQ 94915 Operation manual

EBCHQ

EBCHQ 94915 Operation manual

Balluff BIP LD2-T017-01-EP-S4 Series user guide

Balluff

Balluff BIP LD2-T017-01-EP-S4 Series user guide

Pulsar IMP Lite Series instruction manual

Pulsar

Pulsar IMP Lite Series instruction manual

ETCR 6800 user manual

ETCR

ETCR 6800 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

1
iU2-C UVC Light Meter User Manual
Congratulations on your purchase of this Santacary iU2-C UVC Light
Meter. iU2-C is a precise meter that measures ultraviolet UVC
radiation.
UVC wavelength is 200-275 nm, also known as short wave sterilization
ultraviolet. Peak wavelength of the curve between it and bactericidal
efficiency (265 nm) is very close, so when 253.7 nm radiation reaches a
certain value, it can be used to treat intestinal bacteria, aspergillus
flavus and HBsAg (hepatitis B surface antigen) and other pathogens
were killed in a short time. Ultraviolet germicidal lamp emits UVC short
wave ultraviolet.
FEATURES
Gallium Nitride Based Material Photovoltaic Mode
High-precision detection, rapid response and operation
Good Visible Blindness
Only one power button and easy to operate
Two AAA Alkaline Batteries
APPLICATION:
Monitoring UVC Germicidal Lamp Intensity & Aging
Monitoring Water Treatment Disinfection Lamp Intensity & Aging
Testing Eyewear UVC Blocking Capabilities
Measuring Germicidal Lamp Fixture Leakage
Testing UVC Intensity in Semiconductor Fabrication, Offset Printing,
Environmental Monitoring and Industrial Process Control.
DEVICE
1. LCD display
2. Power button
2
3. UVC sensor
OPERATION
When the device is turned off, press Power button to turn on the unit.
Press Power button again to turn off the unit. When the unit is first
turned on, it performs 5 seconds countdown for device warm up, then
enters normal display. The device updates readings every 2 seconds.
The UVC radiation intensity unit is µW /cm2.
SPECTRAL RESPONSE
3
SPECIFICATIONS
UVC Specification
UVC Measurement Range
0 to 3000 µW/cm2
Spectral Detection Range
220 to 280 nm
Peak point of Spectrum
265 nm
Measurement accuracy
±4% or ±1 digits
Resolution
1.0 µW/cm2
Temperature Range
-10 to 50°C (14 to 122°F)
Humidity Range
0 to 90%RH
General
Operating
-10°C to 50°C (14°F to 122°F), 0~90% RH
non-condensing
Storage
-10°C to 60°C( 14°F to 140°F), <99% RH
4
non-condensing
Power Supply
Two AAA Alkaline Batteries
Dimensions
67x124x25 mm (2.64x4.88x0.98”)
Weight
123 grams (4.34 oz.) with batteries
MATERIALS SUPPLIED
Santacary iU2-C UVC Light Meter
Protector Bag
English User Manual
Two AAA Alkaline Batteries
CLEANING AND STORAGE
The front panel and case can be cleaned carefully with a soft wet cloth.
Allow drying completely before using. Do not use aromatic
hydrocarbons or chlorinated solvents for cleaning.
WARRANTY
The iU2-C is warranted to be free from defects in material and
workmanship for a period of two year from the date of purchase. This
warranty covers normal operation and does not cover misuse, abuse,
alteration, neglect, improper maintenance.
CONTACT US
Zhaobei Building B, the 7th Industrial Road 75#,
Shekou, Shenzhen, 518067,
Guangdong, China
Email: info@santacary.com
All rights reserved including the right of
reproduction in whole or in part in any form.