Santerno ES851 User manual

•15G0851Q1 •
DATA LOGGER
ES851
BASIC – ADVANCED
USER MANUAL
-Programming Instructions-
Issued on 23/01/09
R. 02
Ver. 1.67x
Elettronica Santerno S.p.A.
Strada Statale Selice, 47 – 40026 Imola (BO) Italy
Tel. +39 0542 489711 - Fax +39 0542 489722
www.elettronicasanterno.com [email protected]
•This manual is integrant and essential to the product. Carefully read the instructions contained herein as they
provide important hints for use and maintenance safety.
•This device is to be used only for the purposes it has been designed to. Other uses should be considered improper
and dangerous. The manufacturer is not responsible for possible damages caused by improper, erroneous and
irrational uses.
•Elettronica Santerno is responsible for the device in its original setting.
•Any changes to the structure or operating cycle of the device must be performed or authorized by the Engineering
Department of Elettronica Santerno.
•Elettronica Santerno assumes no responsibility for the consequences resulting by the use of non-original spare-
parts.
•Elettronica Santerno reserves the right to make any technical changes to this manual and to the device without prior
notice. If printing errors or similar are detected, the corrections will be included in the new releases of the manual.
•Elettronica Santerno is responsible for the information contained in the original version of the Italian manual.
•The information contained herein is the property of Elettronica Santerno and cannot be reproduced. Elettronica
Santerno enforces its rights on the drawings and catalogues according to the law.
English

BASIC - ADVANCED DATA LOGGER
PROGRAMMING INSTRUCTIONS ES851
2/66
0. TABLE OF CONTENTS
0.1. Chapters
0. TABLE OF CONTENTS ................................................................................................................................ 2
0.1. Chapters ................................................................................................................................................... 2
0.2. Figures ...................................................................................................................................................... 2
0.3. Tables ....................................................................................................................................................... 3
1. OVERVIEW ................................................................................................................................................. 4
1.1. Main Features............................................................................................................................................ 4
1.2. How to Use this Manual ............................................................................................................................. 4
2. FIRST STARTUP ........................................................................................................................................... 5
2.1. Connections .............................................................................................................................................. 5
2.1.1. Connection to the Link Service................................................................................................................ 6
2.1.2. LAN Connection .................................................................................................................................... 6
2.1.3. Connection via GSM Modem or Analog Modem ..................................................................................... 7
2.2. ES851 Status Display.................................................................................................................................. 7
2.3. Setting the Routing Table ............................................................................................................................ 7
2.4. Programming the LOGGING Function ........................................................................................................ 7
2.5. Parameter Save.......................................................................................................................................... 8
3. MENU LIST ................................................................................................................................................. 9
3.1. Menus and Submenus.............................................................................................................................. 10
3.1.1. Synoptic Table for M Measures............................................................................................................. 10
3.1.2. Synoptic Table for P, R, I, C Parameters ................................................................................................ 10
3.2. List of the BASIC Measures and Parameters ............................................................................................... 12
3.3. List of the ADVANCED Measures and Parameters ...................................................................................... 14
4. DATA LOGGER MENU .............................................................................................................................. 16
5. DATA LOGGING CONSOLE MENU .......................................................................................................... 20
6. SCAN DEVICE 11-40 MENU ..................................................................................................................... 29
7. UPLOAD CONSOLE MENU....................................................................................................................... 33
8. LOG MONITOR MENU ............................................................................................................................. 34
9. EVENT MONITOR MENU .......................................................................................................................... 37
10. MODBUS CONFIGURATION MENU ..................................................................................................... 40
11. CONNECTION CONFIGURATION MENU ............................................................................................ 41
12. TCP/IP PROXY CONFIGURATION MENU.............................................................................................. 45
13. REAL TIME DATA MENU....................................................................................................................... 46
14. MODEM CONFIGURATION AND STATUS MENU ................................................................................. 47
15. SMS MENU .......................................................................................................................................... 48
16. CLOCK/CALENDAR MENU................................................................................................................... 50
17. ROUTING TABLE ÆZONE MENU ........................................................................................................ 55
18. ROUTING TABLE 1-10 MENU............................................................................................................... 57
19. DOWNLOAD CONSOLE MENU ...........................................................................................................59
20. APPENDIX ............................................................................................................................................ 60
20.1. Sunway TG (ST)........................................................................................................................................ 60
20.2. Sunway M XR (SM) ................................................................................................................................... 61
20.3. Smart String Box (QF)............................................................................................................................... 62
20.4. Penta Drive (PD)....................................................................................................................................... 63
20.5. Multipump Penta (PM) .............................................................................................................................. 64
20.6. Regenerative Penta (PR) ............................................................................................................................ 65
20.7. String Box (QS) ........................................................................................................................................ 66
0.2. Figures
Figure 1: The RemoteDrive/Sunway UPLOAD Console. ................................................................................................ 33
Figure 2: SMS format. ................................................................................................................................................ 48
Figure 3: DOWNLOAD Console as displayed in the RemoteDrive/Sunway.................................................................... 59

DATA LOGGER BASIC – ADVANCED
ES851 PROGRAMMING INSTRUCTIONS
3/66
0.3. Tables
Table 1: Default configurations of the available connections........................................................................................... 5
Table 2: Menu List........................................................................................................................................................ 9
Table 3: List of the BASIC measures and parameters.................................................................................................... 13
Table 4: List of the ADVANCED measures and parameters........................................................................................... 15
Table 5: List of the parameters and measures in the Data Logger menu........................................................................ 16
Table 6: List of the parameters and measures in the Data Logging Console menu......................................................... 21
Table 7: Bit-map of the devices boxed after SCANNING. ............................................................................................. 27
Table 8: Bit-map of the recognized devices.................................................................................................................. 27
Table 9: Bit-map of the type of logging for the connected devices................................................................................. 27
Table 10: Bit-map for Event 0 firing for the connected devices. ..................................................................................... 28
Table 11: List of parameters and measures, Scan Device 11-40 ................................................................................... 29
Table 12: Bit-map of the devices boxed after SCANNING. ........................................................................................... 30
Table 13: Bit-map of the recognized devices................................................................................................................ 31
Table 14: Bit-map of the type of logging. .................................................................................................................... 31
Table 15: Bit-map of Event 0 fired for the connected devices. ....................................................................................... 32
Table 16: List of the measures in the Log Monitor menu............................................................................................... 34
Table 17: Bit-map of the Log Status............................................................................................................................. 35
Table 18: List of the measures in the Event Monitor menu. ........................................................................................... 37
Table 19: Bit-map of the Log Status............................................................................................................................. 37
Table 20: Default settings for serial ports COM1 and COM2. ...................................................................................... 40
Table 21: Parameter in the Modbus configuration menu. ............................................................................................. 40
Table 22: List of the parameters in the TCP/IP Configuration menu............................................................................... 41
Table 23: List of the parameters in the TCP/IP Proxy Configuration menu...................................................................... 45
Table 24: Parameter in the Real Time Data menu. ....................................................................................................... 46
Table 25: Parameter in the Modem Configuration menu.............................................................................................. 47
Table 26: List of the measures and parameters in the SMS menu.................................................................................. 48
Table 27: List of the measures and parameters in the Clock/Calendar menu. ............................................................... 50
Table 28: Conventional MODBUS addresses............................................................................................................... 55
Table 29: List of the measures and parameters in the Routing Table ---> ZONE menu.................................................. 55
Table 30: List of the parameters in the Routing Table menu.......................................................................................... 57

BASIC - ADVANCED DATA LOGGER
PROGRAMMING INSTRUCTIONS ES851
4/66
1. OVERVIEW
1.1. Main Features
ES851 Data Logger board allows logging weather variables and operating variables of a photovoltaic (industrial) plant
and allows interfacing the PV plant to a supervisor computer, even a remote computer, through different connecting modes
for data logging and monitoring of the devices connected to the PV plant.
Data is logged to 7 files (Log 1, Log 2, Log 3, Log 4, Log 5, Log 6, Event Log) and can be used to create a database that
can be displayed and graphically represented through the RemoteDrive/Sunway software provided by Elettronica Santerno
(see “How to Use this Manual” below).
ES851 Data Logger board can be handled through dedicated parameters that are divided into menus and submenus.
Each menu includes programmable parameters, measures, and commands.
Data/information is exchanged through COM1 and COM2 serial ports provided with ES851, through the Ethernet socket
for a LAN and the Internet, or through a modem connection.
1.2. How to Use this Manual
This manual covers functionality and first startup of ES851 Data Logger board.
The RemoteDrive/Sunway software provided by Elettronica Santerno allows full exploitation of ES851 Data Logger
functionality. The RemoteDrive/Sunway allows the following functions:
•image acquisition;
•oscilloscope functions and multifunction tester functions;
•table compiler and displayer including operation data log;
•parameter setup and data reception-transmission-storage from and to a computer;
•scan function for the automatic detection of the connected devices (up to 247 devices may be connected).
You can also create your own dedicated software. This manual provides any information concerning addressing (Address
field) and scaling (Range field) for interfacing with the Data Logger.
Some of the operations above can be performed via serial link, through standard RS485 port of the inverter where ES851
is installed, or using the display/keypad unit.
This manual covers the parameter settings as displayed by the RemoteDrive/Sunway; functions implemented in the
display/keypad as well are highlighted accordingly. For more details about functionality of the display/keypad, please refer
to the Programming Instructions manuals relating to the inverters provided with ES851 Data Logger board.

DATA LOGGER BASIC – ADVANCED
ES851 PROGRAMMING INSTRUCTIONS
5/66
2. FIRST STARTUP
This section outlines the basic setup of ES851 Data Logger board with reference to the parameterization detailed in the
sections below. You can use the RemoteDrive/Sunway from a computer connected in local mode to ES851 via COM1
(which is factory set as RS232, Modbus slave).
The first startup of ES851 control board consists of two steps:
1. Connection configuration (see Connections below);
2. Configuration of the data acquisition function (see Setting the Routing Table and Programming the LOGGING
Function).
2.1. Connections
ES851 Data Logger board can be connected to a computer in one of the following modes:
•Local mode: through COM1 and COM2 ports—RS232, RS485 or Ethernet port—for a direct LAN;
•Remote mode: through the Ethernet port or a GPRS modem, both connected via the Internet, or through an
analog modem or a GSM modem for point-to-point connections.
The following sections explain how ES851 is started when using connecting modes other than the default modes, which are
given in the table below.
Note that all parameters relating to ES851 connections are R parameters, which are read and acquired only after resetting
ES851 Data Logger board.
NOTE Configurations other than the default connections can be required when ordering the
equipment.
CONNECTION DEFAULT CONFIGURATION
COM1 RS232 in Modbus Slave mode
COM2 RS485 in Modbus Master mode
Ethernet Link Service with DHCP and DNS
Table 1: Default configurations of the available connections.

BASIC - ADVANCED DATA LOGGER
PROGRAMMING INSTRUCTIONS ES851
6/66
2.1.1. CONNECTION TO THE LINK SERVICE
The connection via the Internet to the Link service is the default connecting mode. The connection to the Link service can be
implemented as follows:
1) Using a router: in that case, no alteration to the default parameters is required;
CAUTION
The connection to the Link service requires the DHCP in the network where ES851
Data Logger board is installed. If the DHCP is not available, disable the DHCP via
parameter R450 in the TCP/IP PROXY CONFIGURATION MENU by selecting one
of the options that do not require using this protocol (e.g. “5: PROXY Ethernet (No
DHCP, DNS )”, “6:PROXY Ethernet (No DHCP, No DNS )”), then enter the static IP
address, the IP mask and the Gateway in the CONNECTION CONFIGURATION
MENU.
2) Using a GPRS modem: in that case, the following modifications are required:
•Connect ES851 to a computer via COM1 port (RS232 Modbus RTU);
•Set parameter R450 as “2: PROXY GPRS modem” (see the “CONNECTION CONFIGURATION MENU”);
•In the parameters relating to the APN (P3110-P3139), enter the APN of the provider, such as
“ibox.tim.it” (see the “CONNECTION CONFIGURATION MENU”);
•Set the PIN of the SIM card being used in parameter R287, which is included in the “MODEM
CONFIGURATION AND STATUS MENU”;
•Save the parameters you have changed (see the “Parameter Save” section);
•Reset the Data Logger so that new settings will take effect.
2.1.2. LAN CONNECTION
CAUTION
The LAN administrator must reserve a STATIC IP address so that it is uniquely
identified, as a dynamic control of IP addresses can change the association
between the MAC address of the Data Logger and the IP address whenever the
equipment is started. As a result, the address required for communication cannot
be known beforehand.
•Connect ES851 to a computer via COM1 port (RS232 Modbus RTU);
•Set parameter R450 = “8: Direct Ethernet” (see the “CONNECTION CONFIGURATION MENU”);
•Save the parameters you have changed (see the “Parameter Save” section);
•Reset the Data Logger so that new settings will take effect.

DATA LOGGER BASIC – ADVANCED
ES851 PROGRAMMING INSTRUCTIONS
7/66
2.1.3. CONNECTION VIA GSM MODEM OR ANALOG MODEM
•Connect ES851 to a computer via COM1 port (RS232 Modbus RTU);
•In parameter R450, choose the type of modem being used by selecting “3: Direct GSM modem” or “4: Direct
Analog Modem” (see the CONNECTION CONFIGURATION MENU);
•If you are using a GSM modem, enter the PIN of the SIM card in parameter R287 (see the CONNECTION
CONFIGURATION MENU);
•Save the parameters you have changed (see the “Parameter Save” section);
•Reset ES851 so that new settings will take effect.
If you are using a GSM modem, you can set a mobile phone number receiving SMS when Events fire (see the SMS MENU).
2.2. ES851 Status Display
From the DATA LOGGER MENU, you can display the status of ES851, which is programmed with factory settings. In
particular, the MAC address is displayed.
Make sure that no alarm trips. If so, try to reset the alarm; if the alarm persists, please contact Elettronica Santerno.
2.3. Setting the Routing Table
The routing table defines the map where the identifier of each device connected to the Data Logger through a given
transmitting device matches with the virtual identifier which the connected device responds to through the Data Logger
itself. In that way, the networked devices can also connected to different apparatuses and can be controlled exactly in the
same way via the Data Logger.
The Routing Table is preset for the automatic detection of the devices connected to RS485 serial link (COM2), if their
identifiers have been previously set to values higher than or equal to 3. Unique identifiers are to be assigned to avoid
conflicts. According to factory settings, COM2 port is already set as Master Modbus, thus allowing handling all the
connected devices. Each address mapped in the table is enabled by default.
The ROUTING TABLE ÆZONE MENU can be used for easier programming of ES851 controlling very complex plants.
2.4. Programming the LOGGING Function
The default LOGGING parameters have been studied by Elettronica Santerno’s technicians in respect to the variables to be
monitored (see APPENDIX). As a result, no modification is required for the DATA LOGGING CONSOLE MENU.
If the number of devices connected to ES851 is limited, an extended (C161) LOGGING can be performed, allowing
monitoring more variables than factory-set variables.
Once the type of LOGGING is selected, activate the SCANNING of the connected devices through I160, allowing
detecting the acronym and the routing address for all the devices connected to ES851. Measure M5049 displays the status
of the LOGGING commands allowing checking if they are correct.
After sending the SCAN command, ES851 performs automatic settings of the parameters for the monitoring of the device
variables (BOXING).
If no LOGGING is required for some of the detected devices, they can be excluded by setting the ‘Type’ field of parameters
C165-C180 and C480-C503. BOXING will be automatically performed by ES851 based on the new information.
You can now start LOGGING through I160. From the LOG MONITOR MENU and the EVENT MONITOR MENU, check if
LOGGING is correct.
To view the logged data, follow the procedure explained in the UPLOAD CONSOLE MENU.

BASIC - ADVANCED DATA LOGGER
PROGRAMMING INSTRUCTIONS ES851
8/66
NOTE
LOGGING is to be activated as the last installation step. Any procedure for the
connection configuration (see sections below) must be performed before LOGGING is
activated.
NOTE The type of LOGGING (extended or standard logging) can be changed for any boxed
device.
To sum up, do the following to activate the LOGGING function in the “DATA LOGGING CONSOLE MENU”:
•Select the type of LOGGING from parameter C161;
•Press the SCAN button;
•Activate LOGGING , I160 “ENABLE All Logs”.
2.5. Parameter Save
After entering the new settings, execute the Eeprom command “5: Save All” (see the “DATA LOGGER MENU”) to keep
them stored even after ES851 is reset. If you are using the RemoteDrive/Sunway software, just press the S key after
changing a parameter, or send the Save All Command.

DATA LOGGER BASIC – ADVANCED
ES851 PROGRAMMING INSTRUCTIONS
9/66
3. MENU LIST
The menu list and the main features of each menu are contained in Table 2 below. Each menu is then detailed on the
following pages.
MENU FUNCTIONALITY
Data Logger Main measures and functions of ES851
Data Logging Console Console for the main logging functions
Scan Device 11-40 Console displaying the connected devices whose IDs range from 11 to 40
Upload Console Console for the acquisition of stored data from ES851
Log 1 Monitor Log 1 status
Log 2 Monitor Log 2 status
Log 3 Monitor Log 3 status
Log 4 Monitor Log 4 status
Log 5 Monitor Log 5 status
Log 6 Monitor Log 6 status
Event Monitor Event status
Modbus Configuration Serial port configuration parameters
TCP/IP Proxy Configuration Configuration parameters for TCP/IP communications with the Link server
Real Time Data Configuration parameters for sending real-time data
Modem Configuration and
Status Modem configuration parameters
SMS SMS activation console
Clock/Calendar Console for clock/calendar settings and display
Routing Table ÆZONE Zone configuration parameters
Routing Table 1-10 Table for the virtual mapping of the devices connected to the Data Logger for IDs 1-10
Download console Console for uploading files to the Data Logger
Table 2: Menu List.

BASIC - ADVANCED DATA LOGGER
PROGRAMMING INSTRUCTIONS ES851
10/66
3.1. Menus and Submenus
Three programming levels are available. They can be changed by setting P298 accordingly.
BASIC (factory setting): permits to view the main measures and to set parameters P298 (programming level) and allows
changing basic programming;
ADVANCED: permits to access the BASIC parameters and the parameters relating to the programming of the available
connections;
ENGINEERING: allows accessing all parameters.
NOTE This manual covers BASIC/ADVANCED parameters only.
3.1.1. SYNOPTIC TABLE FOR MMEASURES
(Read-only)
Mxxx Range Device representation
(integer)
Display on the display/keypad and the
RemoteDrive/Sunway software
(may be a decimal figure)
plus unit of measure
Level Access Level (BASIC / ADVANCED )
Address Modbus address which the measure can be read from
(integer)
Measure Name
Function Measure description.
3.1.2. SYNOPTIC TABLE FOR P, R, I, CPARAMETERS
(Read-Write)
Pxxx Range Device representation
(integer)
Display on the display/keypad and the
RemoteDrive/Sunway software (may be
a decimal figure)
plus unit of measure
Default Parameter factory-setting
(as represented for ES851 board)
Parameter factory-setting (as displayed)
plus unit of measure
Level Access Level (BASIC / ADVANCED)
Address ModBus address which the parameter can be read from/written to
(integer)
Parameter Name
Function Parameter description

DATA LOGGER BASIC – ADVANCED
ES851 PROGRAMMING INSTRUCTIONS
11/66
NOTE
Pxxx Parameters (Always R/W).
Cxxx Parameters (Read-only with LOGGING function activated; R/W with
LOGGING function deactivated).
Rxxx Parameters Always R/W, but they activate only when the device is next
powered on.
Ixxx Inputs These are not parameters, but inputs (the values assigned to these
inputs are not stored to non-volatile memory. They are always set to 0 when the
inverter is powered on).

BASIC - ADVANCED DATA LOGGER
PROGRAMMING INSTRUCTIONS ES851
12/66
3.2. List of the BASIC Measures and Parameters
Menu Parameter FUNCTION MODBUS
Address Default
4 DATA LOGGER MENU P298 Access Level 298 BASIC
I012 EEPROM Command 2003 No Command
M475 Software Version 475 -
M5000 Alarm Condition 5000 -
M5003 Active Access Level 5003 -
M5004 Flash Card Error 5004 -
M5006 MAC Address 5006, 5007,
5008 -
M5199
Latest EEPROM command not
executed 5199 -
8 LOG 1 MONITOR MENU M5050 Log 1 Length 5050 -
M5057 Log 1 Status 5057 -
M5070a-b Year and Month of Activation of Log 1 5070 -
M5071a-b Day and Time of Activation of Log 1 5071 -
M5072a-b
Minutes and Seconds of Activation of
Log 1 5072 -
8LOG 2 MONITOR MENU M5051 Log 2 Length 5051 -
M5058 Log 2 Status 5058 -
M5073a-b Year and Month of Activation of Log 2 5073 -
M5074a-b Day and Time of Activation of Log 2 5074 -
M5075a-b
Minutes and Seconds of Activation of
Log 2 5075 -
8 LOG 3 MONITOR MENU M5052 Log 3 Length 5052 -
M5059 Log 3 Status 5059 -
M5076a-b Year and Month of Activation of Log 3 5076 -
M5077a-b Day and Time of Activation of Log 3 5077 -
M5078a-b
Minutes and Seconds of Activation of
Log 3 5078 -
8 LOG 4 MONITOR MENU M5053 Log 4 Length 5053 -
M5060 Log 4 Status 5060 -
M5079a-b Year and Month of Activation of Log 4 5079 -
M5080a-b Day and Time of Activation of Log 4 5080 -
M5081a-b
Minutes and Seconds of Activation of
Log 4 5081 -
8 LOG 5 MONITOR MENU M5054 Log 5 Length 5054 -
M5061 Log 5 Status 5061 -
M5082a-b Year and Month of Activation of Log 5 5082 -
M5083a-b Day and Time of Activation of Log 5 5083 -
M5084a-b
Minutes and Seconds of Activation of
Log 5 5084 -

DATA LOGGER BASIC – ADVANCED
ES851 PROGRAMMING INSTRUCTIONS
13/66
8 LOG 6 MONITOR
MENU M5055 Log 6 Length 5055 -
M5062 Log 6 Status 5062 -
M5085a-b
Year and Month of Activation of Log
6 5085 -
M5086a-b Day and Time of Activation of Log 6 5086 -
M5087a-b
Minutes and Seconds of Activation of
Log 6 5087 -
9 EVENT MONITOR MENU M5056 Evt Log Length 5056 -
M5063 Evt Log Status 5063 -
M5088a-b
Year and Month of Activation of Evt
Log 5088 -
M5089a-b Day and Time of Activation of Evt Log
5089 -
M5090a-b
Minutes and Seconds of Activation of
Evt Log 5090 -
16 CLOCK/CALENDAR
MENU M5010a Year 5010 -
M5010b Month 5010 -
M5011a Day of the Week 5011 Mon
M5011b Day of the Month 5011 1
M5012a Hours 5012 -
M5012b Minutes 5012 -
M5013 Seconds 5013 -
Table 3: List of the BASIC measures and parameters.

BASIC - ADVANCED DATA LOGGER
PROGRAMMING INSTRUCTIONS ES851
14/66
3.3. List of the ADVANCED Measures and
Parameters
Menu Parameter FUNCTION MODBUS
Address Default Setting
5 DATA LOGGING
CONSOLE MENU M164 Min. Sampling Time 164 -
P229 Initial SCANNING Address 229 1
P230 Final SCANNING Address 230 40
C238 Fast Sampling Only 238 No
C161 Type of Data Logging 161 Standard
C162 Fast Log Sampling Time 162 60 s (1 min)
C163 Fast Log Sample N. 163 1
C245 Fast Log Min. Variation Percent 245 0,0%
C242 Slow Log Sampling Time 242 3600s (1 hour)
C243 Slow Log Sample N. 243 1
C244 Slow Log Min. Variation Percent 244 0.0%
I160 Logger Command 160 No command
M5049 LOGGING Command Status 5049 -
M5016 N. of Devices Detected when
SCANNING 5016 -
M5017 Modbus ID of the Device being
SCANNED 5017 -
C165-a ÷C174-a ID of the Connected Device 165-174 0
C165-b ÷C174-b Type of Connected Device 165-174 No device
detected
M214 Connected Device Boxing 214 -
M215 Recognized Connected Device 215 -
C241 Extended Logging for the
Connected Device 241 Standard logging
for each device
M512 Event 0 Fired for the Connected
Device 512 -
6 SCAN DEVICE 11-40
MENU
C175-a ÷C180-a
C480-a ÷C503-a Connected Device ID 175-180
480-503 0
C175-b ÷C180-b
C480-b ÷C503-b Type of Connected Device 175-180
480-503
No device
detected
M204, M205 Boxing of the Connected Device 204, 205 -
M207, M208 Connected Device Recognized 207, 208 -
C239, C240 Extended Logging for the
Connected Device 239, 240 Long standard for
each device
M510, M511 Event 0 Active for the Connected
Device 510, 511 -
10 MODBUS
CONFIGURATION MENU R297 ES851 Device Id 297 1

DATA LOGGER BASIC – ADVANCED
ES851 PROGRAMMING INSTRUCTIONS
15/66
11 CONNECTION
CONFIGURATION MENU R450 Type of Remote Connection 450 PROXY Ethernet
(DCHP, DNS )
P272 Type of TCP/IP Connection 272 Ethernet
R276 ÷R277 IP Address 276, 277 192.168.0.2
R278 ÷R279 Network Mask 278, 279 255.255.255.0
R247 ÷R248 Gateway 247, 248 0.0.0.0
M5037 RemoteDrive/Sunway Connection
Status 5037 -
12 TCP/IP PROXY
CONFIGURATION MENU P3110 ÷P3139 APN 3110 ÷3139 ‘web.omnitel.it’
13 REAL TIME DATA MENU P578 Time Period for Sending Real-time
Data 578 Data Send
Disabled
14 MODEM
CONFIGURATION AND
STATUS MENU
R287 SIM card PIN 287 “0000”
15 SMS MENU R420 ÷R422 Phone Number 1 420 ÷422 “390000000000”
R423 ÷R425 Phone Number 2 423 ÷425 “390000000000”
M5066 SMS Status 5066 -
P3150 ÷P3177 Message Header 3150 ÷3177 -
P580 SMS Mode 580 Proxy
P294 SMS Sent After Event Disappeared 294 Yes
16 CLOCK/CALENDAR
MENU P2010a Year To Be Changed 2010 2000
P2010b Month To Be Changed 2010 January
P2011a Day Of The Week To Be Changed 2011 Mon
P2011b Day Of The Month To Be Changed
2011 1
P2012a Time (Hour) To Be Changed 2012 0
P2012b Time (Minutes) To Be Changed 2012 0
I2013b Clock/Calendar Editing Command
2013 0
R3200
Time Lag (Hours) of the Local Time
Zone 3200 1
R3201
Time Lag (Minutes) of the Local
Time Zone 3201 0
17 ROUTING TABLE Æ
ZONE P200 ZONE Start ID 200 23
P201 ZONE End ID 201 44
I200 Enable Zone Command 160 -
M5049 Enable Zone Status 5049 -
18 ROUTING TABLE 1-10
MENU P00a ÷P009a Medium for Virtual Address 1-10 0-9
1: ES851 Local
2: ES821 DPR
3 ÷ 9: RS485
Modbus
P00b ÷P009b Device ID for Virtual Address 1-10 0-9 1 ÷ 10
P00c ÷P009c Virtual Address 1-10 Enable 0-9 1
Table 4: List of the ADVANCED measures and parameters.

BASIC - ADVANCED DATA LOGGER
PROGRAMMING INSTRUCTIONS ES851
16/66
4. DATA LOGGER MENU
The Data Logger menu contains all data relating to ES851 and its basic settings. The first parameter being displayed is the
MAC Address, which uniquely identifies ES851 Data Logger board.
The Data Logger menu allows changing the programming level (P298) and displaying the software version (M475)
implemented in ES851. It also allows restoring default values and storing and deleting data acquired by ES851 through
the EEPROM (I012) command. ES851 Data Logger board is provided with two Flash cards for data storage. Parameters
are contained in the DATA FLASH; the Restore Default or Save All commands affect this portion of memory. The Restore
Default command also restores the parameters relating to ES851 for the inverter where the Data Logger is installed. On
the other hand, data stored when LOGGING are stored to 8-Mb FLASH CARD of ES851. As a result, any log operation
(e.g. Erase Log) affects ES851 Flash Card.
M5199 indicates the latest EEPROM command that has not been executed, as well as the alarm tripped and its fault code.
Parameter FUNCTION Access Level
MODBUS Address
P298 Access Level BASIC 298
I012 EEPROM Command BASIC 2003
M475 Software Version BASIC 475
M5000 Alarm Condition BASIC 5000
M5003 Active Access Level BASIC 5003
M5004 Flash Card Error BASIC 5004
M5006 MAC Address BASIC 5006, 5007, 5008
M5199 Latest EEPROM command not executed BASIC 5199
Table 5: List of the parameters and measures in the Data Logger menu.
P298 Access Level
P298 Range 0 ÷2
0: Basic
1: Advanced
2: Engineering
Default 0 Basic
Level BASIC
Address 298
Access Level
Function
The programming parameters for ES851 are grouped by access levels based on
their functions (more or less complex functions).
Some menus, or some parts of menus, are not displayed when a given access level
is selected.
W
hen the BASIC access level is selected if the ES851 parameterization is correct,
navigation is easier, as only frequently accessed parameters are displayed.
In this manual, the Access Level is stated for each parameter.

DATA LOGGER BASIC – ADVANCED
ES851 PROGRAMMING INSTRUCTIONS
17/66
I012 EEPROM Command
I012 Range 0, 5, 11, 30 ÷36, 777
0: No Command
5: Save all
11: Restore Default
30: Erase Log 1
31: Erase Log 2
32: Erase Log 3
33: Erase Log 4
34: Erase Log 5
35: Erase Log 6
35: Erase Event Log
37: Erase All Logs
777: Erase Fault List
Default This is not a parameter: I012
is set to zero at power on and whenever the
EEPROM command is executed.
Level BASIC
Address 2003
EEPROM Command
Function
This parameter saves and restores the entire set of parameters that can be
accessed by the user:
5:Save All, The current value of the RAM parameters is stored to non-volatile
memory (DATA FLASH). All parameters are saved at a time.
11:Restore Default, Factory-set values are restored for all parameters; each
factory-set value is stored to non-volatile memory (DATA FLASH).
30 to 35: Erase Log1,2,3,4,5,6,Event Log, Erases any data in the specified log
(data is stored to FLASH CARD).
36: Erase All Logs, Erases data acquired in all logs (data is stored to FLASH
CARD).
777: Erase Fault List, Erases the fault list stored to DATA FLASH memory.
M475 Software Version
M475 Range 1000÷9999 1000 ÷9999
Level BASIC
Address 475
Software Version
Function This measure indicates the software version implemented in ES851.

BASIC - ADVANCED DATA LOGGER
PROGRAMMING INSTRUCTIONS ES851
18/66
M5000 Alarm Condition
M5000 Range 0 ÷6, 99 ÷103
0: No Alarm
1: Par Save KO
2: Log Write Failure
3: ES821 Init. Failure
4: RS232 Init. Failure
5: RS485 Init.Failure
6: TCP/IP Stack Init. Failure
99: No Flash Card
100: Invalid Stream
101: TCP/IP Socket
103: ES821 Clock
104: Modem Init.
105: Modem KO
Default 0 0: No Alarm
Level BASIC
Address 5000
Alarm Condition
Function
This measure indicates the current alarm tripped for ES851. Please contact
Elettronica Santerno and state the alarm number and name.
0: No Alarm
1: Parameter Save Error
2: Log Write Error
3: FBS Configuration Error
4: Modbus RS232 Configuration Error
5: Modbus RS485 Configuration Error
6: TCP/IP Stack Configuration Error
99: Flash Card Missing or Inaccessible
100: Invalid Access to Stream
101: TCP/IP Socket Error
103: Clock 821 Error
104: Modem Initialization Error
105: Modem Off or Not Connected
M5003 Active Access Level
M5003 Range 0 ÷2
0: Basic
1: Advanced
2: Engineering
Level BASIC
Address 5003
Active Access Level
Function This measure indicates the access level that is currently selected.

DATA LOGGER BASIC – ADVANCED
ES851 PROGRAMMING INSTRUCTIONS
19/66
M5004 Flash Card Error
M5004 Range 0 ÷7
0: No Error
1: Stream Full
2: Checksum Error
3: Invalid Descriptor
4: Invalid Stream
5: Chain Error
6: Invalid Partitioning
7: Stream Busy
Level BASIC
Address 5004
Flash Card Error
Function
The errors above concern the flash card (the memory zone where logs are
stored) and its relevant operations. If an alarm trips, please contact Elettronica
Santerno and mention the alarm number and name.
M5006 MAC Address
M5006 Range 0 ÷248 0 ÷248
Level BASIC
Address 5006, 5007, 5008
MAC Address
Function The MAC Address is the physical address for ES851 network interface.
A unique MAC Address is assigned to each ES851 board.
M5199 Latest EEPROM Command Not Executed
M5199 Range 0, 32773, 32779, 32798 ÷32805,
33545
0: No Command
5: Save all
11: Restore Default
30: Erase Log 1
31: Erase Log 2
32: Erase Log 3
33: Erase Log 4
34: Erase Log 5
35: Erase Log 6
36: Erase Event Log
37: Erase All Logs
777: Erase Fault List
Level BASIC
Address 5199
Latest EEPROM
Command Not
Executed Function
This measure indicates the latest EEPROM command that has not been correctly
executed.
Codification is the same as for I012, but the most significant bit is set to one,
thus changing the range of values that can be assigned to this measure.

BASIC - ADVANCED DATA LOGGER
PROGRAMMING INSTRUCTIONS ES851
20/66
5. DATA LOGGING CONSOLE MENU
This is the main operating menu. The parameters contained in this menu permit to SCAN the devices controlled by the
Data Logger, to automatically program the parameters relating to the variables monitored by the device LOGGING (this
function is called BOXING) and to activate/deactivate/delete the files containing LOGGING-monitored data.
The parameters specific to the variables monitored by the LOGGING (BOXING) function are automatically programmed
after SCANNING (I160) and after programming certain parameters that can be modified by the user. Parameters specific
to the monitored variables can be accessed only if the Engineering access level is selected. Variables that can be monitored
are automatically divided into 6 groups, which are called Log1, 2, 3, 4, 5, 6.
Automatic LOGGING can be either standard or extended logging (C161). When extended logging is activated, more
variables are monitored if compared to the standard logging.
According to factory setting (standard LOGGING for each device), each ES851 board can perform the LOGGING function
for each device connected to the plant, up to max. 40 devices. The type of LOGGING can be selected for each connected
device, for the optimization of the number of devices that can be boxed.
In both cases, the acquired variables are detected within a parameter set contained in a table which is unique to each
device and which is stored to ES851 when factory setting is performed (see APPENDIX).
Two log groups are available: Fast Log (C162, C163, C245) and Slow Log (C242, C243, C244), which are characterized
by a different factory-set sampling time of the logged variables. The parameters above allow the user to change the
sample number and the minimum variation percent of a data item for its logging.
ES851 Data Logger is also capable of logging data relating to each connected inverter when one of its variables changes.
Besides recording the alarms of the connected devices, ES851records to the Event file the non-response from one of the
connected devices (a non-response event is an Event 0). The parameters specific to the Event Log are inaccessible at a
Basic level and are automatically BOXED along with the parameters of the other logs. Their values are stated in the tables
stored during the factory setting stage (see APPENDIX).
After SCANNING, you can manually deselect some of the detected devices.
This menu views the first 10 devices that are detected from ES851 Data Logger. The setting of the next 30 devices, if
detected, can be viewed and changed in the SCAN DEVICE 11-40 MENU.
After each operation on the parameters above, ES851 performs automatic BOXING based on the new stored values.
The Data Logging Console menu also includes a set of measures indicating the command status and the programming
status of ES851.
NOTE
The factory-settings of the parameters included in the Data Logging Console menu
do not require any customization. You can just use the SCAN command and the Log
Enable command through parameter I160.
Table of contents
Popular Data Logger manuals by other brands

Wavetronix
Wavetronix Click 514 Installation & quick start guide

socomec
socomec DATALOG H60 quick start

DAC
DAC Data Logger v2 Series General user manual

MadgeTech
MadgeTech QuadTCTempV2 Product user guide

Worldwide Construction And Forestry Division
Worldwide Construction And Forestry Division 2054 Operator's manual

Omega
Omega OM-91 quick start guide