The information in this document is subject to change without notice. (04|2018)
iMS 58 G
iMS 58 E
iMS 54 E
iMS Bridge
iMS NT
MANUAL
Modular Multiswitch System
MANUAL
Modular Multiswitch System
SEITE 4 PAGE 1
www.satrix-MEDIA-COM
skytronic Multimedia Technologie GmbH
Hasselborner Strasse 19-21
35647 Waldsolms (GERMANY)
Phone: +49 6085 9897950
E-Mail: [email protected]
Safety Instructions
The main socket should be easily accessible. In the event of operational error,
the plug must be immediately removed from the socket. The power supply is
started up when the plug is inserted in the socket. To turn off the power supply,
the plug must be removed from the socket. Never pull at the cable. The power
supply contains dangerous voltages and the cover should not be removed. All
service or maintenance work should be carried out by qualifed personnel who
can get assistance by contacting the manufacturer’s agent. With visible damages
to the device do not use this any more.
Standards
CE-Sign (Conformity Declaration of European Union):
The CE symbol documents compliance with the directives of the european union.
Protection insulation
This device has protection class II.
The power supply is double and high insulated.
Mounting
Use only in dry rooms. This product is only designed for indoor use and should not
come into contact with water or dust. To prevent overheating the power supply
should not be covered when it is in use. The ambient temperature must not
exceed 55 ° C. Only mount on a fire-proof area.
Disposal
Electronic equipment is not domestic waste - it must be disposed of properly in
accordance with directive 2002/96/EC OF THE EUROPEAN PARLIAMENT AND
THE COUNCIL dated 27th January 2003 concerning used electrical and electronic
appliances. At the end of its service life, take this device for disposal at a designated
public collection point. WEEE-Reg.-Nr.: DE 78634072
www.satrix-MEDIA-COM
QUATTRO
or
QUAD LNC
Installation
.
Please fix the mounting brackets with the nuts on the F-Jacks of the main body as shown on the picture
below (use the 2 F-Jacks which are closest to the LNB-Inputs). Connect the 4 cables coming from LNB
(VL/HL/VH/HH) and the optional terrestrial antenna to the related inputs of the multi- switch. If you are
using a Quattro-LNB please make sure the outputs of the LNB are connected to the correct inputs of the
multiswtich (VL to VL / HL to HL / VH to VH / HH to HH). If you are using
a switchable QUAD-LNB you can use any cable from LNB to any input of
multiswitch.
Extension to more outputs
.
You can upgrade the basic unit SATRIX iMS 58 G (8 subscriber outputs) with the extension unit
SATRIX iMS 54 E (4 subscriber outputs) or unit SATRIX iMS 58 E (8 subscriber outputs) up to a total
number of 48 subscribers. For the installation of one or several extension units please follow below
steps:
• Unplug the AC cable of the Unit SATRIX iMS 58 G power supply from the mains.
• Release the screws on the left and right side of the ABS power supply housing.
• Unplug the power supply from the main body of the multiswitch SATRIX iMS 58 G.
• Plug the extension unit (SATRIX iMS 54 E or iMS 58 E) direct to the power supply and fix the power
supply with the screws.
• Plug the original main unit SATRIX iMS 58 G to the extension unit (SATRIX iMS 54 E or iMS 58 E)
and fix the units with the supplied screws.
• Make sure that no matter how many extension units are installed so that the first unit
• closest to LNB is the original main unit SATRIX iMS 58 G.
Mounting of extension unit
.
Basic unit iMS 58 G und extension unit iMS 54 E:
iMS54E iMS NT
iMS58G
iMS58G
iMS58E
Basic unit iMS 58 G und extension unit iMS 58 E:
Important Notice:
.
The basic unit SATRIX iMS 58 G is equipped with an integrated terrestrial amplifier, which has
enough gain to supply a quality signal to the extension units. For this reason, it is necessary to
install the basic unit SATRIX iMS 58 G always as the first unit closest to the LNB and the extension
units between the basic unit and the power supply, otherwise the function can be affected.
Optional accessories:
.
SATRIX iMS Bridge - Cascade extension adapter
PAGE 2 PAGE 3
www.satrix-media.com www.satrix-media.com
iMS NT

This manual suits for next models

4

Popular Switch manuals by other brands

HP HP E1368A/69A/70A user manual

HP

HP HP E1368A/69A/70A user manual

Cisco TOPSPIN SFS 3012 Hardware guide

Cisco

Cisco TOPSPIN SFS 3012 Hardware guide

Heathkit Heathkit HD-1481 Operation manual

Heathkit

Heathkit Heathkit HD-1481 Operation manual

Enterasys Matrix E1 1G694-13 Configuration guide

Enterasys

Enterasys Matrix E1 1G694-13 Configuration guide

KSR KUEBLER BGU D Series operating instructions

KSR KUEBLER

KSR KUEBLER BGU D Series operating instructions

LEGRAND 0 488 07 manual

LEGRAND

LEGRAND 0 488 07 manual

ClodPi Labs ATOM Hub quick start guide

ClodPi Labs

ClodPi Labs ATOM Hub quick start guide

Intellitronix N3210 Installation guides

Intellitronix

Intellitronix N3210 Installation guides

StarTech.com HB20A7AME instruction manual

StarTech.com

StarTech.com HB20A7AME instruction manual

ATEN KVMP CS1822 user manual

ATEN

ATEN KVMP CS1822 user manual

Siemens SENTRON VL Series operating instructions

Siemens

Siemens SENTRON VL Series operating instructions

3Com Gigabit Switch 8 installation guide

3Com

3Com Gigabit Switch 8 installation guide

GE MULTILINK ML2400 instruction manual

GE

GE MULTILINK ML2400 instruction manual

PowerBox Systems PowerBox 12 operating instructions

PowerBox Systems

PowerBox Systems PowerBox 12 operating instructions

Fujitsu XG2000CR Hardware guide

Fujitsu

Fujitsu XG2000CR Hardware guide

ZyXEL Communications ZyXEL Dimension ES-2724 Specifications

ZyXEL Communications

ZyXEL Communications ZyXEL Dimension ES-2724 Specifications

NTI UNIMUX-2X8-U Installation and operation manual

NTI

NTI UNIMUX-2X8-U Installation and operation manual

Champion Power Equipment RELIANCE CONTROLS ARM Series installation manual

Champion Power Equipment

Champion Power Equipment RELIANCE CONTROLS ARM Series installation manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.