SATTLER LUCE VERDE SLIM User manual

1
Assembly instruction Date: 01.10. 2015
LUCE VERDE SLIM
Bom. (Caps) Part Quantity
Package 1
Circular aluminum-profile 11 unit
acrylic glass ring and 4 steel cables,
Inner surface made of dried moss
Package 2
Canopy 21 unit
incl. power supply unit
External power supply unit 31 unit
White gloves 41 pair
Screwdriver 1 unit
Assembly instructions 1 unit
Dimmer
Not dimmable
DMX interface
Dimmer interface 0-10V
DALI interface
Installation Version
Supply line 24 V
Technical Data:
Measurements Ø mm / inches Weight kg / lbs
Light Fixture Canopy/
Operating Unit
Ø 1300 / 51.2 35 / 77.1 5.0 / 11.0
B
Page 7
A
Page 5
E
Page 3
1
4 2 3
Page 6
W
GENERAL REMARKS ON SAFETY:
Read all of these instructions before installing fixtures.
• Keep all of the instructions for future reference.
• Turn off power before installing fixture.
• Installation is to be performed by a qualified electrician only.
• All installations are to conform to the standards of National
Electrical Code as well as all local jurisdictional codes and
regulations.
• Any modification of the luminaire will void any and all written or
implied warranties.
• Do not open the luminaire - this will void the IP rating
• The manufacturer accepts no responsibility for damage to
persons of property arising through improper use or installation.
THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE
WITH THE APPLICABLE INSTALLATION CODE BY A PERSON
FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF
THE PRODUCT AND THE HAZARDS INVOLVED

2
2 Packages
Assembly instruction Date: 01.10. 2015
Delivery contains 2 packages
Unpack the light fixture and check the bill of material.
Use enclosed cloth gloves to prevent smudging of polished frame,
screws and acrylic.
Do not remove the protective foil until after assembly.
Warranty
Use the enclosed assembly instructions for
the installation of the lighting fixture. Non-
compliance of the assembly instruction will
automatically void the warranty.
The supplied light fixture has been tested
and is fully operational.
LUCE VERDE SLIM, Pendant Light, assembly version
E
LUCE VERDE SLIM
LUCE VERDE SLIM, Wall Light, assembly version
W

3
E
E
LUCE VERDE SLIM
Assembly instruction Date: 01.10. 2015
Light fixture with canopy –
Connection of the light fixture
with separate power supply cable
Mounting of the canopy
Make sure the ceiling has sufficient support capacity!
1. Fit the base of the canopy to the ceiling with the 4 mounting
points. Ø Drill 6mm / 1/4“ holes and anchor to fasten canopy
to ceiling (see scale sketch on the left).
2. Connect the power supply and the control signal to the terminal
block of the canopy (see wiring diagram page 8.
Connection of the light fixture
3. Fix light fixtures with 4 cables (depending on light fixture
diameter) to the canopy at the provided cable grippers and
align by applying light pressure on the steel cable grippers.
Observe minimum / maximum suspension height on page 4.
Consider the polarity of the current-carrying cables in
accordance with the markings on the light fixture and the
canopy.
Never adjust the suspension under pressure. The steel
cables might get damaged.
4. Lock the cable grippers in place by use of the insulated knurled screw.
5. Shorten excessive steel cables in order to prevent short circuits.
Shortened cables can only be replaced by the factory!
6. Insert the power supply line through the side of the ceiling plate
and connect it to the terminal block in accordance with the wiring
diagram (p. 8)
7. Mount the canopy cover and fasten it with screws from the side.
8. Check whether the light fixture is functioning.
Canopy with mounted cover
Canopy Ø 290 mm / 11,4“ with 4 steel cables

4
E
LUCE VERDE SLIM
Ø 1300 mm / 51.2“
LUCE VERDE SLIM
Assembly instruction Date: 01.10. 2015
Light fixture with canopy
1300 mm / 51.1“
minimum (b) respectively maximum (c) ceiling suspension

5
A
A
L
H
W
L
H
W
12
3
LUCE VERDE SLIM
Assembly instruction Date: 01.10. 2015
Light fixture with steel cable
suspension – Connection of the
light fixture with external power
supply unit
Mounting of the cable grippers, installation of
the light fixture
Make sure the ceiling has sufficient support capacity!
1. Mark the 4 anchor positions of the light fixture on the ceiling.
2. Drill Ø 6mm / 1/4 holes, insert anchors and fasten steel cable
holders, see pictures 1 + 2.
The steel cable grippers cannot be used for outdoor are-
as. Make sure cables are not damaged. Prior to moun-
ting, the nozzle of the steel cable bracket has to have
noticeable spring pressure. In order to ensure full sus-
pension, the steel cables have to be clean and free from
greases, oils and rust. The steel cable grippers can only
be used in connection with the provided fixation cables
for stationary and static loads, see picture 3
3. Insert the cables which have been pre-attached to the light
fixture in the steel cable grippers.
4. Lift the light fixture in its desired position and adjust by applying
light pressure on the steel cable grippers.
5. If provided, lock the steel cable grippers in place by use of the
insulated knurled screw.
6. Shorten excessive steel cables.
Shortened cables can only be replaced by the factory!
Assembly of the operating unit, connection to
light fixture
Mount external power supply unit only in a dry and aerated
place!
Power supply cable from the operating unit to the light fixture
max. 10m / 33 feet
Assembly of external power supply vertically or horizon-
tally (see sketch)
7. Open the housing of the operating unit by loosening the 4 screws.
8. Fasten operating unit sufficiently.
9. Connect primary connection and power supply cable of the light
fixture according to the wiring diagram (p.8), then fasten the
housing of the operating unit again.
10. Check whether the light fixture is functioning.
suspended ceiling
ceiling external power supply unit
The cable exit angle at
the nozzle must not be
more than 10° in any
case.
max. 10°
Power supply unit DE 1F
L/W/H
360 x 150 x 85 mm
4.7 x 5.9 x 3.3“
The measurements of the power
supply unit may vary depending on
light fixture configuration.
max. 10m / 33 feet

6
W
1116 mm / 43.9“
558 mm / 21.9“
2 wall hooks for fixing
LUCE VERDE SLIM
Assembly instruction Date: 01.10. 2015
Wall lamp incl. 2 wall hooks for fixing and external power supply unit in false wall

7
B
B
max. 10m / 33 feet
Ø cover plate
Ø body
3
12
LUCE VERDE SLIM
Assembly instruction Date: 01.10. 2015
Typ Canopy Maße mm / inch
DB 290 Ø 290 / 260 mm / 11.4 x 10,2“
The cable exit angle at
the nozzle must not be
more than 10° in any
case.
max. 10°
Light fixture with steel cable
suspension – Connection of the
light fixture with separate
canopy
Mounting of the cable grippers, installation of
the light fixture
Make sure the ceiling has sufficient support capacity!
1. Mark the 4 anchor positions of the light fixture on the ceiling.
2. Drill Ø 6mm / 1/4 holes, insert anchors and fasten steel cable
holders, see pictures 1 + 2.
The steel cable grippers cannot be used for outdoor are-
as. Make sure cables are not damaged. Prior to moun-
ting, the nozzle of the steel cable gripper has to have
noticeable spring pressure. In order to ensure full sus-
pension, the steel cables have to be clean and free from
greases, oils and rust. The steel cable gripper can only be
used in connection with the provided fixation cables for
stationary and static loads, see picture 3
3. Insert the cables which have been pre-attached to the light
fixture in the steel cable grippers.
4. Lift the light fixture in its desired position and adjust by applying
light pressure on the steel cable grippers.
5. If provided, lock the steel cable grippers in place by use of the
insulated knurled screw.
6. Shorten excessive steel cables.
Shortened cables can only be replaced by the factory!
Assembly of the canopy, connection to light fixture
Power supply cable from the operating unit to the light
fixture max. 10m / 33 feet
7. Mark the 4 anchor positions of the canopy on the ceiling according
to the scale sketch (page 3) – different measurements
depending on size. Drill Ø 6mm / 1/4 holes, insert anchors and
fasten canopy.
8. Connect primary connection in accordance with the wiring
diagram.
9. Insert the power supply cable that has been pre-attached to
the light ring in the side of the canopy and connect to the
terminal block according to wiring diagram (p. 8).
10. Mount canopy cover and fasten with screws from the side.
11. Check whether the light fixture is functioning.

8
LUCE VERDE SLIM
Assembly instruction Date: 01.10. 2015
Wire shall be #18AWG stranded minimum. Large gauge wire shall be used to limit voltage
drop in order to maintain the proper operating voltage. Take every precaution to avoid interferance from other
electrical circuits and equipment.
LEDs shall be wired in parallel as shown in wiring diagram. CAUTION: incorrect wiring may damage LEDs.
Wiring Key Points
Dimming circuits are more sensitive to voltage drop and electrical interference from other
electrical sources.
Isolating LED wiring by dedicated circuit for each control zone is recommended.
1.
6.
5.
4.
3.
2.
LED’s can be permanently damaged if these points are not followed
7.
prior to energizing the circuit.
All Class II power cable remote wiring and driver enclosures by others.8.
-
+
24VDC
Constant
Voltage
Driver
Hot
Neutral
AC input
ground
(green)
Fixtures wired in PARALLEL.
Check driver’s rated wattage
information below.
DC output
+
LED
Conductor colors may vary.
+
-
TYPICAL DIAGRAM
-
+
-
+
-
Maximum wiring distance*
* Voltage drop guide for 24VDC. Actual
Voltage drop to be calculated by installer.
LED LED
≤48W ≤72W ≤96W
#18AWG 37' 25' 18'
#16AWG 59' 39' 29'
#14AWG 95' 63' 47'
#12AWG 151' 101' 75'
#10AWG 241' 160' 120'
Wire gauge
Load per driver
US & Canada contact: Inter-lux, 3741 Commerce Dr. #306-308, Baltimore, MD 21227. Main (410) 381 1497 www.inter-lux.com
The manufacturer accepts no responsibility for damage to persons or property arising through improper use or installation.
Table of contents
Other SATTLER Light Fixture manuals
Popular Light Fixture manuals by other brands

RSA Lighting
RSA Lighting Combolight GRF416 Specifications

Knightsbridge
Knightsbridge LED3 Series Installation & maintenance manual

LUCIS
LUCIS PALA LR Mounting instructions

Lightolier
Lightolier 4SB115 specification

Home Accents Holiday
Home Accents Holiday Adorable Dogs LED Husky Assembly instructions

Osram
Osram KREIOS FL Installation and safety instructions

Robe
Robe Ambiane user manual

Cooper Lighting
Cooper Lighting ALL-PRO Series specification

WAC Lighting
WAC Lighting Mini Flood 5121-27/30BZ Installation instruction

Safegate Group
Safegate Group SafeLED Series manual

ProLights
ProLights Astra Wash7PixIP user manual

Lightronics
Lightronics FXLD127FR5I owner's manual