Saunacore Xtreme Steam Tech Steamcore Spa II User manual

OPERATION & INSTALLATION MANUAL
STEAM GENERATORSTEAM GENERATOR
aobsessed with qualiy...
aquality of life
TM

Ŀ¼
User Manual
Manual
Users instruction----------------------------------------------------------------1
The steam equipment installation location----------------------------------- 1
The typical illustration of the steam equipment installation----------2
Installation of the steam line ---------------------------------------------- 3
Drawing of the steam generator----------------------------------------------5
Electrical requirements---------------------------------- ----------------------6
Power line assembly illustration----------------------------------------------7
Generators internal electrical wiring---------------------------------------8
Installation of the mood light--------------------------------------------------11
Choosing your models-----------------------------------------------------------12
Steam generator structural drawing-----------------------------------------13
Safety precautions of the controller-----------------------------------------14
The safety and operating instruction of the controller-----------------14
----------------------------------15
Controller installation instructions ------------------ ---------------------16
----------17
-------------------------18
-----------------------------------------18
-------------------------20
---------------------------------------20
Maintenance of the steam generator ---------------------------------------22
Trouble shooting -----------------------------------------------------------------23
Specifications -------------------------------------------------------------------24
Control panel (both SSI and SSII) dimensions
Temperature sensor installation (only for SS I Control Panel)
Illustration for the controller panel (SS I Control Panel)
Operation instruction (SS I Control Panel)
Illustration on the controller panel (SS II Control Panel)
Operation instructions (SS II Control Panel)

Ö ØÒ ª:
Prologue
Users instruction
δ°´±¾ÊÖ²áÖ¸Òý°²×°Ê¹Óõ¼ÖµÄÒâÍ⣬±¾¹«Ë¾¸Å²»¸ºÔð¡£
Óû§ÐëÖª
¾ ¯
¸ æ:
Caution:
We are not responsible for the malfunction and damage from
installation that does not comply to the user manual.
1.Make sure the model and the accessories are correct,including the voltage imput.
2.Make sure the steam power are matched with the steam room dimension. Pay much
attention to the steam room's cubage and construction.If you have any problem,please
refer to the Page 11 about the dimension selection.
3. Make sure to read this in manual detail.
4.We shall not be responsible for the product damage or malfunction caused by self-
installation.
5.Steamcore Spa II series are packged in a box,please check the goods when it
arrives to assure it is in good conditon, if you find any damage in the package,please
contact the transportation company to file a claim for compensation.
6.This product must be used indoors.
Some locations recommended for installation.
1. The distance to the steam room less than 20ft, the standard cable which link the
controller and the steam generator 22ft.
2. The steam generator should not be installed in the steamroom
3. Do not install outdoorsor in any places that will influence the security of the machine
by the environment.
4. Do not install a frigid loft or any placewater will freeze.
5. Do not install it near burnable and combustible .
objects or chemicals
6. Install in a dry place and make adequate ventilation.
Page 1
Important:
Choosing a right location
Install an exhaust fan outside of the steam room so it can expel
the excessive steam from the shower room.
User Manual
Certified to CAN/CSA Std. No. 88
Conforms to UL. Std. 499
THIS UNIT MUST BE COMPLETELY INSTALLED WITH UNIONS TO ALLOW EASY REMOVAL IF FUTURE SERVICE IS NEEDED.
NOTE: Use teflon tape on the water intake solenoid and the drain solenoid to create a tight seal between the threads.
Absolutely do NOT apply heat to the plastic solenoids (water intake & drain) during installation.
It is strongly recommended that the water intake solenoid be connected to a water supply using a braided hose line.
Teflon tape is required to make a liquid tight seal between the threads and a rubber gasket (washer) is used to seal
between the solenoid and the braided hose attachment. Incorporate thread sealant (teflon tape) on both the water intake
and drain solenoid for a tight seal to avoid leaks.
Technical Hotline 905-951-6662

Steam generator
Water Drain Valve
Water Inlet Pipe
Steam outlet pipe
Control panel
Supply
Steam Outlet
Pressure
relief
valve
!
7.Stable and horizontal.The steam generator has a hanging groove for mounting on the
wall.Make sure the machine is steady and horizontally installed.
8.On both sides and the top of the steam generator needsat least 12 inches of clearance space.
9.The place where the machine is installed must be easily accesible and convenient for
the disassembly of the machine.
10. The installation place must be convinent for the drain ofwater.
11.The steam pipe,safety valve, drain valve,water tube,steam outlet are still very hot after
the steam generator hasstopped working for some time. Keep the steam outlet
away from the people. Bodily injury or burn may occur, provide appropriate protection.
12.The controller must be installed in the steam room,please refer to the instruction
of the controller's installation and operation of the manual.
The steam generator(including the controller)
comply with CE , CSA
and UL certificat ion standards.
!
Page 2
Attention:
Attention:
Installation drawing of the steam generator
The drawing isonly
for sample. As for practical
design of steam room, please
consult with qualified designer,
architect or builder.
User Manual
Fill & Drain Solenoid Valves
Control Cable
(20ft max)

Ó ÉÓ ÚÕ ôÆ ûÅ ç× ìº ÍÕ ôÆ û³ ö¿ Ú· dz £È È£ ¬Ó ¦
± ÜÃ â½ «
Õ ô
Æ ûÅ ç× ì° ²× °Ô ÚÁ ÜÔ ¡Õ ßÈ ÝÒ ×¾ -
³ £½ Ó´ ¥µ ½µ ÄÎ »Ö ã ¬Ò Ôà âÅ ç³ öµ ÄÕ ôÆ û· É
½ ¦£ ¬µ ¼Ö Â
Ì ÌÉ ËÊ ¹Ó ÃÕ ßµ ÄÎ £Ï Õ¡ £
× ¢
Ò â
:
Water supply pipe (1/2'')
!
Ó ÉÓ Ú
Õ ô Æ ûÅ ç× ìº ÍÕ ôÆ û³ ö¿ Ú· dz £È È£ ¬Ó ¦± Üà ⽠«
Õ ô
Æ û
Å ç× ì° ²× °Ô ÚÁ ÜÔ ¡Õ ßÈ ÝÒ ×¾ -
³ £ ½ Ó´ ¥µ ½µ ÄÎ »Ö ã ¬Ò Ôà âÅ ç³ öµ ÄÕ ôÆ û· ɽ ¦
£ ¬µ ¼
Ö Â
Ì Ì
É ËÊ ¹Ó ÃÕ ßµ ÄÎ £Ï Õ¡ £
× ¢
Ò â
:
!
Installation of pipeline
The installation of all the pipes should be done by a qualified
licensed plumber.
Warning:
1. Use threaded unions when connecting pipes to fill/drain valves and steam line(s).
2. Use brass or copper only.
3. Do not use ABS, galvanized or PVC pipes.
1. Connect hot water or cold water. Hot water with a temperature of not more
than 160 .
2. Install shutoff valve in the water supply pipe. The shut off valve should be installed in a
place where it is easily operated in emergency.
3. Clean the water supply pipe completely before connecting the water pipe to the steam
generator.
4. It is suggested that a filter and anti-furring equipment be used in the water supply pipe.
5. The water pressure should be between 15 and 20 psi. If necessary,
decrease the
pressure accordingly. Excess pressure may cause leakage. The water flow rate should be aprox 8 gpm.
.
6. If necessary, install equipment to prevent the water hammering sound, also install an approved
Steam Pipe
1.Do not install any valves in the steam pipes. The steam can never be obstructed.
2.Install one or more steam lines equal to your steam generator steam outlet(s) and with the same
same diameter size copper steam pipe
between the steam outlet and the steam nozzle.
3.The heat insulation material used to insulate the steam pipe should be resistant to
temperature as high as 250 or higher.
4.The horizontal part of the steam pipe should be installed inclining to the steam outlet or
in the direction of steam generator. Do not bend it in a shape to make the cooled
water stay in the curved pipe of the steam line.
5.The shorter the steam pipe, the better. Try to decrease the number of elbows and avoid
abrupt turns. Do Not combine steam lines if generator has more than one steam outlet.
(Pipe Diameter: 3kW/4.5kW pipe size: 1/2'' 6kW & above: 3/4'')
Attention:
Do not install the steam pipe in an upper or lower direction repeatedly,this
will affect the output of steam.
Atte ntion:
Attention :
Since the steam nozzle and steam outlet are very hot, try to avoid installing
the steam nozzle in the position which will easily come into contact with aperson
1.Install the steam nozzle in the position 12 inches above the ground. If the steam bath is
in the bathtub, install the steam nozzle 6 inches above the bathtub. If the
steam room materials like acrylic or non-heat-resistant sheet, install
additional heat insulators.
2.The steam outlet should be installed face down. Install the steam nozzle and tighten
with hands (use silicone).
In order to protect the steamnozzle, do not use wrench or other tools
to tighten, use a little soap water and soft sponge to wipe, and do not use corrisve
chemical solutions or harsh cleaning tools.
Page 3
Steam nozzle (3kW/4.5kW pipe size: 1/2'' 6kW & above: 3/4'')
User Manual
DO N OT H EAT AU T O FI LL / DRAI N V ALV ES WITH TORCH DURING I N ST ALLAT I ON .
This will cause damage to the plastic solenoid valve which will cause malfuction or leakage.
backflow preventer as required by local codes. It is suggested that a thread on braided hose with a rubber
washer be used for the water supply line in order to attach the shutoff valve to the water intake solenoid.
Also use adequate teflon tape around the thread of the solenoids for a tight seal between the two fittings.
Make sure for each steam outlet on the generator there is an individual
steam pipe to the steam room with the same diameter size as the outlet.
Install steam heads away from bathers path or from any direct contact. Add appropriate protection
to avoid bodily harm or burns.

!
!
Important:
1.Please consult your distributors of building materials like acrylic, fiber glass or other
anti-heat sheet about the installation position of steam nozzle. It is suggested that MS-
103412 anti-heat material can be used.
2.In the entire steam room, it is required that steam must not leak out. The pipes, its
accessories and the holes in the wall should be airproof by applying silicone so
that no steam will enter the holes in the wall.
If non-heat-resistant material like
acrylics is used as building material,
reserve a gap no less than 1/4''
and fill with silcone.
Silicone
Use silicone to fill in the
gaps in the wall to
achieve the water proof and
damp-proof effect.
Inside wall of the steam room
Drainpipe (1/2'')
According to national or local codes, the steam generator drainage valve should be equipped
with a drain pipe. The steam generator drains the water by using gravity.
The drain pipe should not incline upwards so as to prevent the drainage of water.
Safety Pressure valve(s)
1.Pressure valve is a safety equipment in order to prevent too much steam pressure in
the steam generator due to various reasons; such as, steam line blockage,
2. The Steam Safety Pressure Valve & Switch Application is Mandatory.
Attention:
Page 4
User Manual
(Supplied only - must be installed on-site by plumber)
A Pressure Safety Valve (Steam Pressure Valve) has been supplied with this steam generator unit.
The steam generator has removable sealed plugs in place of the pressure valve mounting location (labelled).
Unscrew the plugs, and screw on the pressure relief safety valve supplied. Make sure hi-heat silicone
is used to seal the safety valves to the boiler tank when attaching, allow silicone to cure 24 hours.
The Pressure safety relief valve must be installed by a qualified licensed experienced plumber.
undersized steam lines, steam line traps, vandalism, etc.
A qualified licensed plumber must install the supplied pressure valve during installation of the steam generator.
Steam Generators 18 KW (18000 watts) and higher will have a factory installed Steam Pressure Switch.
This switch will cut power to the steam generator when the inside of the boiler tank or steam line(s)
pressure reaches over the manufacture's recommended limit. The switch will reset and activate power
when the excessive pressure has been substantially reduced. This will re-occure until the cause of excessive
pressure has been rectified.
DO NOT H EAT AU T O FI LL / DRAI N V ALV ES WITH T ORCH DU RI N G INST ALLAT ION.
This will cause damage to the plastic solenoid valve which will cause malfuction or leakage.
DO NOT REDUCE THE STEAM LINE PIPE DIAMETER.
Steam generators 10.5 kw and up have an additional manual drain port
right next to the auto drain port. This is only used for manual draining and
should remain closed at all times.
Aroma Essence Reservoir
(apply a few drops)

Steam generator blue print.
Page 5
Safety valve
Steam outlet
Water inlet
Water
drainage
160mm
148mm
98mm
25mm
35mm
130mm
209mm
230mm
244mm
260mm
395mm
Fuse for wire power supply
Power wire hole Controller wire
and light wirehole
304mm
Safety valve
Steam outlet
Water inlet
Water
drainage
213mm
190mm
115mm
29mm
156mm
260mm
307mm
315mm
335mm
465mm
383mm
Fuse for wire power supply
Power wire hole Controller wire
and light wirehole
Fuse for wire
power supply
User Manual
Fuse for wire
power supply
(metal conduit connector
required)
(metal conduit connector
required)

!
!
!
Electrical requirements:
Electricity supply:
1.Test the voltage of electricity supply and make sure steam generator with suitable electric
voltage is used.
2.Insulated copper wire should be used with an anti-heat temperature of 90 and a
specified voltage of 300V. Refer to national or local electricity consumption code for
specifications.
3.Install an independent circuit breaker between the power supply and the steam
generator so to provide an electricity supply with overflow protection and electricity
leakage protection.
All the connectionsmust be in accordance with national and local
electricity consumption code and be installed by professional licensed electricians.
Attention:
to facilitate maintenance, keep the steam engine clean. If the information
provided is limited, do not touch the pipeline and electric equipment.
Attention:
Caution:
to avoid damage to the equipment, do not connect strong electric current
directly to the components.
510mm
435mm
Steam outlet
Safety valve
Water inlet
Water
drainage
Fuse for wire power supply
Power wire hole Controller wire
and light wirehole
300mm
340mm
350mm
385mm
205mm
265mm
215mm
142mm
28mm
Page 6
User Manual
Fuse for wire
power supply
A suitable metal conduit and metal conduit connector should be used for the main power wiring connections.
(metal conduit connector
required)

!
Ampere Meter
!
The data provided above are for 240V(1PH) and 208V(3PH). Consult the manufacturer for
three-phased electricity or electric voltage of other specifications. Within the steam generator,
install an independent circuit breaker so as to provide an electricity supply with
overflow protection and electricity leakage protection (ground fault interrupter.)
Power Supply Wire Connection
To avoid damage to the equipment, do not connect strong electric
current to the component directly.
This drawing is for explanation only. For actual installation, refer to
national and local electricity consumption codes by professional licensed electricians.
Attention:
Warning:
Page 7
240V~ 1PH
240V~ 1PH
240V~ 1PH
240V~ 1PH
240V~ 1PH
208V~ 3PH
240V~ 1PH
240V~ 1PH
208V~ 3PH
12.5A
18.75A
25A x 3
Type Applicable space of
3
the room (m )
Electricity
supply
Electric
current (A)
L1 L2 L3
(240V~ 1PH) (208V~ 3PH)
L1
L1 L2 L3
Power connection terminal
User Manual
3kW
4.5kW
6kW
7.5kW
9kW
10.5kW
12kW
13.5kW
15kW
18kW
208V~ 3PH
208V~ 3PH
208V~ 3PH 18~22
15~20
14~18
12~15
12~15
10~13
8~12
8~12
6~10
5~8
4~7
3~6
25A
31.25A
37.5A
43.75A
50A
33.3A x 3
37.5A x 3
41.7A x 3
50A x 3
L2
L1 L2
The total connected load should not be more then 80% of the rating of the overcurrent devices.
European Connection
( L2 = N "Neutral")

Page 8
J2-1
J2-2
J1-2
J1-1
J1J2
S S
Supply
Red
Black
Red
Black
Red
Red
ToControl Panal
Fill water valve
Drain water valve
Terminal Block Yellow/Green
Red
Black
Red
Black
Yellow
Red
Black
Red
Red Red
Red
Water Level Sensor
Red(Short Pin)
Black(Long Pin)
Yellow(Middle Pin)
Red
Black
Red
Blue
Brown Red
Light
J1-1
J1-2
J1
S S
L1
G
Supply
Red
Red
Black
To Control Panal
Fill water valve
Drain water valve
Terminal Block
Yellow/Green
Red
Black
Red
Black
Yellow
Red
Black
Red
Red Red
Red
Water Level Sensor
Red(Short Pin)
Black(Long Pin)
Yellow(Middle Pin)
Black
Red
Blue
Brown Red
Light
J1-1
J1-2
J1
S S
Supply
Red
Red
Black
To Control Panal
Fill water valve
Drain water valve
Terminal Block
Yellow/Green
Red
Black
Red
Black
Yellow
Red
Black
Red
Red Red
Red
Water Level Sensor
Red(Short Pin)
Black(Long Pin)
Yellow(Middle Pin)
Black
Red
Blue
Brown Red
Light
L2
Black
Black
Wiring Diagram 240V(1PH)
N L
L1
G
L2
N L
L1
G
L2
N L
Optional
Optional
Optional
Steamcore Spa * * 3kW (240V - 1PH)
Steamcore Spa * * 4.5kW (240V - 1PH)
Steamcore Spa * * 6kW / 7.5kW / 9kW (240V - 1PH)
Steamcore Spa * *
auto reset
hi-limit
auto reset
hi-limit
auto reset
hi-limit
manual
reset
hi-limit
manual
reset
hi-limit
manual
reset
hi-limit
European Connection
( L2 = N "Neutral")

J1-1
J3-2
J2-2
J1-2
J1
S S
Red
Black
Red
Black
Red
Red
To Control Panal
Fill water valve
Drain water valve
Terminal Block
Yellow/Green
Red
Black
Red
Black
Yellow
Red
Black
Red
Red Red
Red
Water Level Sensor
Red(Short Pin)
Black(Long Pin)
Yellow(Middle Pin)
Red
Black
Red
Blue
Brown Red
Light
Red
Red
Supply
J2J3
J2-1
Black
J3-1
Black Black
Black
L1
G
L2
N L
Optional
Steamcore Spa * * 10.5kW / 18kW (240V - 1PH)
auto reset
hi-limit
manual
reset
hi-limit
European Connection
( L2 = N "Neutral")

Wiring Diagram 208V (3PH)
Page 10
J2-1
J1-2
J1-1
J1J2
S S
Supply
Red
Red
Black
Red
Red
ToControl Panal
Fill water valve
Drain water valve
Terminal Block
Yellow/Green
Red
Black
Red
Black
Yellow
Red
Black
Red
Red Red
Red
Water Level Sensor
Red(Short Pin)
Black(Long Pin)
Yellow(Middle Pin)
Red
Red
Blue
Brown Red
Light
G
L1L2L3
Red
Red
J2-2
J2-1
J3-1
J1J3
S S
Supply
Red
Red
Black
Red
Red
ToControl Panal
Fill water valve
Drain water valve
Terminal Block
Yellow/Green
Red
Black
Red
Black
Yellow
Red
Black
Red
Red Red
Red
Water Level Sensor
Red(Short Pin)
Black(Long Pin)
Yellow(Middle Pin)
Red
Red
Blue
Brown Red
Light
G
L1L2L3
Red
Red
J1-2 Red
Red
J1-1 Red
Red
J3-2 Red
Red
J2
To Control Panal
Terminal Block
J2-2
J1-1
J1-2
J3-1
J2-1
J3-2
J1J2J3
Yellow/Green
Red
Black
Black
Red
Black
G
Supply
L1L2L3
Red
S S
Fill water valve
Drain water valve
Yellow
Red
Black
Red
Red Red
Red
Water Level Sensor
Red(Short Pin)
Black(Long Pin)
Yellow(Middle Pin)
Red
Blue
Brown Red
Light
Optional
Optional
Optional
Steamcore Spa * * 15kW / 18kW (208V - 3PH)
Steamcore Spa * * 9kW (208V - 3PH)
Steamcore Spa * * 10.5kW / 12kW / 13.5kW (208V - 3PH)
Steamcore Spa * *
manual reset
hi-limit
auto reset
hi-limit
auto reset
hi-limit
manual
reset
hi-limit
manual
reset
hi-limit
auto reset
hi-limit
12 psi pressure switch (UL - USA Application 18kw & Up)
European Connection
( L2 = N "Neutral")

!
The calculation formula for selecting the size of steam generator is for
reference only. Due to the variability of the building, the specifications and size
illustration are used as guidelines only. If we have complete information, including
actual blueprint, project instruction and building details, we can select the type of
generator.
Important:
Page 11
User Manual
Sizing steam generator
Measure the length, width and height (feet) of the current steam shower or bathtub area
Example;
L:7xW:5xH:8 = 280 Cubic Feet
You would need a 9000 watt (9KW) steam generator.
However, if your shower materials are;
x 25% for Ceramic Wall Finish = 61.25 (61.25+280) = 341 Total.
that has a ceramic wall finish.
(is multiplied by:)
Acrylic, cultured marble.
Ceramic Tile on Cement Board.
Ceramic Tile on Mortar Bed.
Glass or Glass Block
Porcelain tile on cement board
NATURAL STONE TILE (marble, granite, slate, travertine, etc)
On Cement Board.
On Mortar Bed.
Natural Stone Slabs over 1/2" thick
Each Exterior Wall(s) Insulated
0.08
1.30
1.30
1.35
1.60
1.90
2.00
2.25
1.10 for each outside wall

!
Installation of the top light
CAUTION:
The rating of the light should not surpass 40W(rated power) to prevent damage to
the transformer.
The light should be installed on the top of the steam room or in a place which is not
accessible to children.
!
CAUTION:
Take some moisture proof measures in the process of installation. Do
not let the electrical components be exposed to moisture or, it will cause damage or
short circuit.
The illustration is just for explaination,the practical installation must comply with
the nation's electric criteria,and performed by aprofessional licensed electrician.
!
CAUTION:
(Possible location)
The steam outlet
Under Sink
(possible location)
The steam generator
Light
The steam control panel
Page 12
User Manual

1
2
3
5
4
6
12
14
11
8
10
7
15
17
16
1Enclosure
2
3
Circuit board
4
Steam Outlet
5
6
Water fill valve
7
Water drain valve
8
Subsidiary water tank
9
Main water tank
10
Heating Element
Heat Hi-limit
Transformer
11
12
Terminal block
Fuse
Ground wire connector
16
Relay
Water level sensor
17
15
14
13
Page 13
Configuration of steam generator
Fuse
13
17
9
User Manual
Use teflon tape and rubber gasket (washer) when attaching fittings to the water fill and drain valve to create a liquid tight seal.
Pressure Safety Valve
DO NOT HEAT
DURING INSTALLATION.
(heating with torch will cause
damage to plastic solenoid valve)
Mood light transformer
18 Manual Reset Hi-Limit
18
19
19

!
!
!
Controller Maintenance
1.Use soft cloth with a little soap/water to clean the controller.
2.Do not use harsh cleaning tools.
3.If the controller is damaged, call a service electrician to replace it.
Safety and operation information of the controller
Warning:
If the installation and operation instruction is not read or understood, do
not install. In case there should be any dangerous installation and improper
operation.
Install the controller based on the installation instruction otherwise, the temperature in
the steam room will be too high or not heated enough.
If the controller is installed outside the steam room, the temperature sensor must be
installed in the steam room.
Caution:
Do not install the controller wire in the same conduit with high voltage electric
wire. Do not install close to hot water or steam pipe.
Important:
Before installing the controller, make sure the steam generator power is
off otherwise the controller may be damaged.
The instruction includes important safety, operation and maintenance information.
Keep the instruction in the user's hands.
If the steam generator is damaged or does not work normally, do not continue to install
or use the controller. Turn main power supply off.
Page 14
User Manual

Page 15
User Manual
Control panel (both SSI and SSII) dimension
113mm 25mm
75mm
SSI and SSII Control panel may be switched for Spa II
SS I
SS II
160mm
120mm
23mm
70mm

Installation instruction of controller
!
Important:
Before installing the controller, make sure the steam generator is shut off
otherwise the controller may be damaged.
Step one
Determine the installation location of the controller.
The controller is designed to be installed in the steam
room :
1. 4-5 feet from the ground.
2. Away from the steam nozzle and do not expose
under the direct path of steam.
3. Installation on perpendicular wall.
4. The position of installation should facilitate easy
operation and convenient wiring.
The controller wire is 1.0feet long with a controller
lengthened wire of 20 feet long at the most. In the
installation of controller, it should be in a position not
more than 21 feet from the steam engine. If longer
wire is needed, contact professional service personnel.
!
Important:
Page 16
User Manual
!
Important:
Do not install the controller under the
water pipe or in a position where water comes into contact.
Step two
Drill a round hole of 35mm in diameter in a chosen
position, no larger or smaller.
Step
three
Pull the controller wire through the round hole,
connect it to the lengthened wire and then to the steam
generator ,and connect with the corresponding wire in
the
generator .When the computer wire is plugged in, aim
at
the direction and insert horizontally, instead of shaking
left and right in case the computer needles could be
damaged. Do the same when unplugging.
!
Do not pull tight, or clip tight the
controller wire
in case
of causing damage to it.
Step four
Start the power supply of steam engine, check and
adjust connection, check each item on the page to
make sure all functions work well.
before repairing the controller, make
sure the steam generator is shut off otherwise the
controller may be
damaged.
Important:
Aor
Control Panel
(1ft)
(1ft)
(20ft)
SS II
Extended wire
Steam Generator
Control Panel SS I

!
Page 17
User Manual
Control Panel SS I
Control Panel SS I
Control Panel SS II
Temperature sensor
Locknut for temperature
sensor base
Drill
10
1cm
Ground
1.2~1.5m
1.The position of the temperature sensor should be within a range of 1.2-1.5M above the
ground. Try to avoid installing near the steam nozzle or the opening side of the steam
room door.
2.As shown in Fig.1, drill a small hole of 10mm in the selected position.
3.Apply a circle of silicone along the edge of the back of the sensor base (as shown in Fig.2).
4.Use a locknut to lock the sensor foundation. (As shown in Fig.2)
5.Let the temperature sensor go through the back of the sensor holder (As shown in Fig.3)
6.The temperature sensor should be installed by extending about 1cm from the front of
the room to make sure the speed and accuracy of temperature control.
7.Apply silicone to the back and fix the sensor. (As shown in Fig.3)
(Fig.1) (Fig.2)
(Fig.3)
Temperature sensor
base (optional)
Step five
Remove the paper on the backside.
To achieve good sticking effect, keep
the mounting surface clean and dry.
Step six
Locate the display screen in the
direction of 12 o'clock, and press tight
the controller to stick it to the wall.
To ensure horizontal
installation of the controller, use a
level if necessary.
Important:
Control Panel SS II
Temperature sensor installation(only for SS I )Control Panel

Illustration ofthe controller panel (SS I )Control Panel
Page 18
User Manual
Operation instruction (SS I )Control Panel
1
5
2
10
2
1
2
Steam Temperature Adjust Key--HIGH
3
4
5
6
Steam ON/OFF
Power Indicator LED
LED SCREEN
Mood Light Indicator LED
Mood Light ON/OFF
Steam Time Adjust Key--LOW
7
8
9
10
Power ON/OFF
Steam Temperature Adjust Key--LOW
Steam Time Adjust Key--HIGH
2 9
3
2
8
2
4 7
6 6
Power ON/OFF
When unit is powered on, power indicator LED should be lit. Press
and release button to activate system and all function buttons.
Meanwhile, power indicator LED goes out. Water input steam boil
tank automatically, and LED screens display . Shut down the
system, press button again. System drains out water in generator
water tank automatically. (NOTE: If power indicator LED flashes
when system is activated, it reports that generator water tank is lack
of water. System shuts down power supply to heater elements, and
opens water inlet valve to refill water until reaching required volume.)
IN/OUT SHOWER USE
Table of contents
Other Saunacore Iron manuals
Popular Iron manuals by other brands

BLACK DECKER
BLACK DECKER BXIR2400E Original instructions

Silvercrest
Silvercrest SDBS 2400 A1 operating instructions

EUROPRO
EUROPRO EP171 Use and care instructions

EUROPRO
EUROPRO POWERPRO GI468H owner's manual

BLACK DECKER
BLACK DECKER F550 Original instructions

Silvercrest
Silvercrest SDBK 2200 A1 operating instructions