Thankyouforpurchasingthislightfitting.Pleasereadtheinstructionscarefullybeforeusetoensuresafeandsatisfactory
operation of this product. Please retain these instructions for future reference.
Warning
This light fitting is Class 1 and must be connected to
an Earth circuit
Please read these instructions carefully before
commencing any work.
It is recommended that these floor standing lights
are installed by a qualified electrician in accordance
withcurrentIEEWiringRegulationsandlocalBuilding
RegulationsandarefortheDomesticenvironmentonly.
Topreventelectrocutionswitchoffatmainssupply
before installing or maintaining this fitting. Ensure other
persons cannot restore the electrical supply without
your knowledge. If you are in any doubt, please consult a
qualified electrician.
Thislightfittingshouldbeconnectedtoacircuitwitha
30mARCDfitted.
If replacing an existing fitting, make a careful note of the
connections.
Thissystemcontainsnon-replaceablepartsandcannotbe
serviced. If damage occurs the part should be scrapped.
Waste electrical products should not be disposed of with
household waste. Please recycle where facilities exist.
Check with your local authority or retailer for recycling
advice.
TheselightshaveanIP54(splashproof)ratingsuitable
for use outdoors.
Thisproductisnotsuitablefordimming.
Thisproductisnotsuitableforlocationinorneara
marine or sea environment.
Specification
Voltage: 240V 50Hz a.c.
Lamp: 9W LED (SMD 5630)
IP rating: 54
Layout
• Planthedesiredlayoutofthisfittingcarefully,ensuring
the cables will reach the distance between the junction
box and the light fitting
• Avoidlocatinganycablesinpositionsthatwould
cause a hazard. Position cables and junction boxes (not
supplied) away from areas where they may be at risk
from being cut, trapped or damaged
• Cablesinwallsmustbeprotectedusingsuitable
conduit or plastic trunking.
• WerecommendthatyouuseH05RN-Fspecification
cable (not supplied) which is an outdoor grade, rubber
sheathedcable.Themainssupplycablemusthavea
minimum cross sectional area of 1.0mm²
• Thesefittingmustbemountedoneitheraconcrete
surface or a paving slab that has been concreted in
position.
Installation
Existing fittings must be completely removed before
installationofanewproduct.Beforeremovingtheexisting
fitting, carefully note the position of each set of wires.
• Usingthebaseplateasatemplate,markthefixing
holes onto the mounting surface.
• Drillholestothenecessarysizeanddepth-takingcare
not to damage any concealed pipes or wiring below the
mounting surface.
• Thisproductcomescompletewithscrewandrawlplugs
which are suitable for use on most surfaces, however
alternative fixings may be required.
• Pushtherawlplugsintothemountingholes.
• Fitbaseplatetomountingsurfaceusingsupplied
screws
Wiring
Having correctly identified the wiring from your existing
light fitting, pull the wire through the hole and connect to
the connection block inside the product in the following
way:
• Pullterminalblockfrominsideoftube.
• Unscrewthe4screwswhichattachtheblackboxto
the spacing strip. Open the black box and pull out the
terminal block.
• ConnectLiveinputwiretobrownwireonproduct(or
terminal on terminal block marked ‘L’).
• ConnectNeutralinputwiretobluewireonproduct(or
terminalonterminalblockmarked‘N’).
• ConnectInputEarthwire(Green/yellow)toEarthwireon
fitting,
• Checkthatyouhavecorrectlyidentifiedthesupply
wires, the connections are tight and that no loose
strands have been left out of the connection block.
• Pushterminalblockbackintotheblackbox.Re-attach
the black box to the mounting bracket.