manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Saxon
  6. •
  7. Portable Generator
  8. •
  9. Saxon AA1678 User manual

Saxon AA1678 User manual

AA1678
Waste electrical products should not be
disposed of with household waste. Please
recycle with your local authority or retailer.
POWER STATION
Manual
Please read the following safety and operating instructions carefully
Product No: AA1678
The AA Power Station is an ideal home accessory and an emergency power pack
which can be used to jump start a battery, inflate tyres and illuminate an area when
required.
This Power Station is suitable for starting 2.5L Petrol / 1.6L Diesel vehicles with
overload and over charge protection. The Power Station contains with an air
compressor which can be used to inflate tyres in an emergency.
The Power Station has an LED status indicator to show how much charge is left in the
unit, plus a battery status indicator to give an instant view of available charge. It
comes with an AC power supply for easy recharging providing up to 6 hours of DC
power when 240V sockets are not available. It has a tough, durable case with a built
in LED light for roadside emergency repair.
POWER STATION
WARNING
PLEASE READ INSTRUCTIONS CAREFULLY BEFORE USE.
ALWAYS CHECK EQUIPMENT BEFORE USE. IF DAMAGED, DO NOT USE AND DISCARD.
PLEASE RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE
This Power Station is designed for domestic use and for intended purpose only. It is not designed
and is not fit for commercial, industrial or rental use.
This appliance is not intended for use by children or by persons with reduced physical, sensory
on mental capabilities.
Read all instructions and warnings prior to using this product. Improper use of this product may
result in product damage, excess heat, toxic fumes, fire or explosion, for which the manufacturer
is not responsible.
IMPORTANT SAFETY INFORMATION:
• Inspect the Power Station before each use, ensuring there is no damage to the
components. Do not open the Power Station to replace the internal battery, there are
no user-replaceable parts inside.
• Always check your vehicle’s user manual before attempting to jump-start your vehicle
to determine that on-board computers will not be damaged.
• Do not use on a broken or frozen battery.
• Do not submerge this appliance in water, or expose it to rain or moisture.
• Do not expose your Power Station to fire, intense heat, or flammable liquids.
• Keep away from and out of reach of children.
• Must only be used by a responsible adult.
• Do not insert foreign objects into ANY inputs or outputs.
• Do not use this product where there are flammable fumes, gases, or dust present.
• Connect this Jump Starter as per your vehicles manual.
• Do not expose to temperatures over +140°F (+60°C) or under -4°F (-20°C).
• Always disconnect the jump start cables from the Jump Starter after use and store as
indicated.
• Never leave the Jump Starter/Air Compressor connected to the car battery
unattended.
• Keep the power cord in good condition i.e. by avoiding extreme temperatures and not
lifting using cord etc.
• Must be charged in a well ventilated environment.
• In case of an electrical or mechanical fault, immediately switch off and unplug the
compressor.
• Do not bend or restrict the air hose whilst the compressor is in use.
• The compressor should not be used for more than 10 minutes at any one time. If using
for extended periods give the compressor a 15 minute break allowing for it to cool
between use.
• For safety reasons the compressor should not be left running unattended.
• Please refer to your vehicle handbook for the correct tyre pressure required for your
vehicle.
• Only use on tyres and inflatable items taking care not to over inflate.
• Store in safe dry place when not in use.
• Only use with 12v lead acid batteries.
• Do not smoke, use matches or lighters near this equipment.
• Do not submerge in water.
• Keep clamps in storage compartment when not in use.
• Your Power Station must be disposed of properly at your local recycling facility when
it is no longer able to be used.
Please retain manual for future for future reference.
Saxon disclaims any liability for damage arising from misuse of this product.
TECHNICAL SPECIFICATIONS
JUMP STARTER:
AIR COMPRESSOR:
Suitable for vehicles
2.5 Petrol / 1.6 Diesel
Note – extreme cold temperatures will affect the
battery and product performance. If you operate in
these conditions for any length of time, please consider
using an alternative product
Battery
Start/peaking current
12V 10Ah lead acid battery. Maintenance free, including
overload protection & reverse polarity indicator
250-600A
Maximum Pressure 150psi / 10 bar
Pressure Gauge
Light
Selectable readings in PSI / BAR (Accurate to +/- 3 PSI)
LED work light & flash light
Output 12V/15 Amp
Air hose length 60cm
USB 5V/2 Amp
3
POWER
USB
ON/OFF
SWITCH
LED
LIGHTS
JUMP STARTER
CLAMPS
DC 12V
SOCKET
CHARGE
SOCKET
CHARGE
POWER STATION
BATTERY
STATUS INDICATOR
(REVERSE)
AIR COMPRESSOR
& AIR HOSE
240V POWER
SUPPLY
WARNING
PLEASE READ INSTRUCTIONS CAREFULLY BEFORE USE.
ALWAYS CHECK EQUIPMENT BEFORE USE. IF DAMAGED, DO NOT USE AND DISCARD.
PLEASE RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE
This Power Station is designed for domestic use and for intended purpose only. It is not designed
and is not fit for commercial, industrial or rental use.
This appliance is not intended for use by children or by persons with reduced physical, sensory
on mental capabilities.
Read all instructions and warnings prior to using this product. Improper use of this product may
result in product damage, excess heat, toxic fumes, fire or explosion, for which the manufacturer
is not responsible.
IMPORTANT SAFETY INFORMATION:
• Inspect the Power Station before each use, ensuring there is no damage to the
components. Do not open the Power Station to replace the internal battery, there are
no user-replaceable parts inside.
• Always check your vehicle’s user manual before attempting to jump-start your vehicle
to determine that on-board computers will not be damaged.
• Do not use on a broken or frozen battery.
• Do not submerge this appliance in water, or expose it to rain or moisture.
• Do not expose your Power Station to fire, intense heat, or flammable liquids.
• Keep away from and out of reach of children.
• Must only be used by a responsible adult.
• Do not insert foreign objects into ANY inputs or outputs.
• Do not use this product where there are flammable fumes, gases, or dust present.
• Connect this Jump Starter as per your vehicles manual.
• Do not expose to temperatures over +140°F (+60°C) or under -4°F (-20°C).
• Always disconnect the jump start cables from the Jump Starter after use and store as
indicated.
• Never leave the Jump Starter/Air Compressor connected to the car battery
unattended.
• Keep the power cord in good condition i.e. by avoiding extreme temperatures and not
lifting using cord etc.
• Must be charged in a well ventilated environment.
• In case of an electrical or mechanical fault, immediately switch off and unplug the
compressor.
• Do not bend or restrict the air hose whilst the compressor is in use.
• The compressor should not be used for more than 10 minutes at any one time. If using
for extended periods give the compressor a 15 minute break allowing for it to cool
between use.
• For safety reasons the compressor should not be left running unattended.
• Please refer to your vehicle handbook for the correct tyre pressure required for your
vehicle.
• Only use on tyres and inflatable items taking care not to over inflate.
• Store in safe dry place when not in use.
• Only use with 12v lead acid batteries.
• Do not smoke, use matches or lighters near this equipment.
• Do not submerge in water.
• Keep clamps in storage compartment when not in use.
• Your Power Station must be disposed of properly at your local recycling facility when
it is no longer able to be used.
Please retain manual for future for future reference.
Saxon disclaims any liability for damage arising from misuse of this product.
HOW TO CHARGE:
The internal battery should only be charged using the accessories provided.
1. Via mains power (240V), AC charger plug provided.
2. Via 12V power socket.
USER GUIDE:
1. The Power Station and USB power can be turned on/off using the Power Switch.
2. Pressing the “ON/OFF BUTTON” will indicate the battery status of the Power Station.
The unit will automatically turn off after 15 seconds of inactivity to
conserve power.
3. A long press of the “ON/OFF BUTTON” will operate the LED light. Press it again to
operate the flash setting and pressing for a further time will turn the LED lights off.
When the three lights are fully lit on the Battery Status Indicator the Power Station is fully
charged. If only two lights are showing, the unit is at 50% of its maximum power. When one light
remains or the lights are flashing, the unit needs to be fully re-charged. The lights will flash
during charging and all 3 lights will remain on until the power supply is removed.
For maximum battery life, it is recommended that you keep the Power Station fully charged at all
times. Once you have used the unit as a jump starter, please fully recharge the appliance. For
each attempt at jump starting, an additional 4 hours is required to charge the internal battery.
Do not attempt more than four restarts of the vehicle. If your vehicle doesn’t start after four
attempts, please seek alternative assistance.
54
USING THE JUMP STARTER
The Jump Starter provides a current up to 600 amp to assist starting a car.
Check to ensure the following before connecting the booster cable clamps to the car battery:
• Ensure the ignition is off.
• Ensure all ancillary equipment (lighting, radio etc.) is switched off.
• Ensure the vehicle battery is rated at 12V and is not damaged in any way.
• Ensure the battery terminals are perfectly clean, the clamps are firm and perfectly secure.
Before using the Power Station to jump start your vehicle, please read and follow these
instructions and consult your vehicle manual.
1. Identify the polarity of the battery terminals. The battery terminal is typically marked with a
(+) symbol for the positive terminal and a (-) for the negative terminal.
2. Identify if you have a negative or positive grounded vehicle. This can be done by identifying
which battery post ( + / - ) is connected to the chassis.
6
12
3. For a negative grounded vehicle (most common),
connect the RED POSITIVE clamp first to the battery
terminal, then connect the BLACK NEGATIVE clamp to
the negative terminal or vehicle chassis. Note, when
disconnecting, do so in reverse sequence, removing
the negative first (or positive first for positive grounded
systems).
4. Attempt to switch on the engine of the casualty vehicle.
5. Once the engine starts running, disconnect the black clamp " - " first and return it
to its storage position. Then disconnect the red clamp " + " from the battery
terminal and restore it to its storage position. Important: If your engine doesn’t
start, wait at least 3 minutes before trying again. Do not allow the positive and negative
cables to touch during this process.
Re-charge your Power Station as soon as possible after using it as a jump starter. Please see
charging table for a representation of charging times relative to the amount of attempts for using
as a jump starter.
USING THE AIR COMPRESSOR
• Remove your tyre dust cap from the tyre valve.
• Carefully uncoil the air hose on the Power Station and attach to your vehicles tyres.
• Wait a few moments and your current air pressure will be displayed.
• Switch the “ON/OFF SWITCH” on the Power Station to “ON” and the compressor will
automatically start to inflate.
DO NOT USE CONTINUOUSLY FOR MORE THAN 10 MINUTES
• Once the desired pressure has been met, turn the “ON/OFF SWITCH” to “OFF”, then
disconnect the valve connection
• Replace any dust caps which have been removed
Not suitable for use with domestic inflatable items.
7
PRESSURE
GAUGE
ON/OFF
SWITCH
Air compressor on reverse of Power Station.
30
60
90
120
150
0
0
1
23
4
5

Popular Portable Generator manuals by other brands

Troy-Bilt 030594-00 Wiring diagram

Troy-Bilt

Troy-Bilt 030594-00 Wiring diagram

COM-power corporation APF-5060 instruction manual

COM-power corporation

COM-power corporation APF-5060 instruction manual

Matsusada Precision RK Series instruction manual

Matsusada Precision

Matsusada Precision RK Series instruction manual

Power SUA2700i quick start guide

Power

Power SUA2700i quick start guide

Generac Power Systems 15 kW EcoGen Installation guidelines

Generac Power Systems

Generac Power Systems 15 kW EcoGen Installation guidelines

Onan DYH Series Operator's manual and parts catalog

Onan

Onan DYH Series Operator's manual and parts catalog

Generac Power Systems GP Series owner's manual

Generac Power Systems

Generac Power Systems GP Series owner's manual

Westinghouse WH4500 owner's manual

Westinghouse

Westinghouse WH4500 owner's manual

MinXray HF100 Service manual

MinXray

MinXray HF100 Service manual

Westerbeke BCD 4.4KW Operator's manual

Westerbeke

Westerbeke BCD 4.4KW Operator's manual

Milwaukee MXF PS Original instructions

Milwaukee

Milwaukee MXF PS Original instructions

DUROMAX XP20HP Service manual

DUROMAX

DUROMAX XP20HP Service manual

GenConnex Honda EU7000is Assembly instructions

GenConnex

GenConnex Honda EU7000is Assembly instructions

Winco W10000VE/B Installation & operator's manual

Winco

Winco W10000VE/B Installation & operator's manual

Briggs & Stratton 30335 Wiring diagrams

Briggs & Stratton

Briggs & Stratton 30335 Wiring diagrams

Powermate Professional 9375 PM0557501 owner's manual

Powermate

Powermate Professional 9375 PM0557501 owner's manual

Porter-Cable BSI550-W instruction manual

Porter-Cable

Porter-Cable BSI550-W instruction manual

TEKSAN GO ON 300W user manual

TEKSAN

TEKSAN GO ON 300W user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.