SBC PCD7.D450WTP Series User manual

Saia Burgess Controls |A
27-621 ENG07 – Manual – Web Panel MB - PCD7.D450WTPx and PCD7.W470WTPx │ 2020-08-20
Serie PCD7.D450WTPx and PCD7.D570WTPx
Wide Screen Micro-Browser Panels
Manual

B
Saia-Burgess Controls AG
27-621 ENG07 – Manual – Web Panel MB - PCD7.D450WTPx and PCD7.W470WTPx

0-1
Saia-Burgess Controls AG
27-621 ENG07 – Manual – Web Panel MB - PCD7.D450WTPx and PCD7.W470WTPx
Content
0
0 Content
0 Content
0.1 Document versions ............................................................................... 0-4
0.3 Brands and trademarks ........................................................................ 0-4
1 Quickstart
1.1 Introduction ........................................................................................... 1-1
1.2 Denition of the connectors ................................................................... 1-2
1.3 Voltage supply of the panel ................................................................... 1-3
1.4 Dimensions and cut-out [in mm] ............................................................ 1-4
1.4.1 5" panel ................................................................................................. 1-4
1.4.2 7" panel ................................................................................................. 1-4
1.5 Installation of the panels ....................................................................... 1-5
1.5.1 Installation in control cabinet ................................................................. 1-5
1.6 Operation and handling of the touchscreen .......................................... 1-6
1.7 Setting up communications for displaying a website ............................. 1-7
1.7.1 HTTP Direct over ethernet RJ-45 connector ......................................... 1-7
1.7.2 USB port as service port ....................................................................... 1-8
1.7.3
Accessing the web editor on the Micro Browser Panel PCD7.D4xx ............. 1-8
2 Technical data for the two panel types
2.1 Technical data of the WVGA MicroBrowser panel ................................. 2-1
3 Operating the setup menu of the WVGA MB panel
3.1 Open the Setup menu ........................................................................... 3-1
3.2 Customising the start screen ................................................................. 3-2
3.3 Changing the password ........................................................................ 3-2
3.4 Saving and exiting ................................................................................. 3-3
4 Structure and description of the Setup menu
4.1 Network ................................................................................................. 4-2
4.1.1 DCHP On .............................................................................................. 4-2
4.1.2 TCP/IP address ..................................................................................... 4-2
4.1.3 Subnet Mask ......................................................................................... 4-2
4.1.4 Default Gateway .................................................................................... 4-2
4.1.5 Primary DNS Server .............................................................................. 4-2
4.1.6 Secondary DNS Server ......................................................................... 4-2
4.2 Web Connection .................................................................................... 4-3
4.2.1 Connection ............................................................................................ 4-3
4.2.2 Edit connection ...................................................................................... 4-3
4.2.2.1 Connection name .................................................................................. 4-3
4.2.2.2 Start page .............................................................................................. 4-3
4.2.2.3 Remote Host IP ..................................................................................... 4-3
4.2.2.4 Remote port .......................................................................................... 4-3
4.2.2.5 Remote password ................................................................................. 4-3
4.2.3 Default password .................................................................................. 4-3

0-2
Saia-Burgess Controls AG
27-621 ENG07 – Manual – Web Panel MB - PCD7.D450WTPx and PCD7.W470WTPx
Content
04.2.4 Search ................................................................................................... 4-4
4.2.4.1 Range Start ........................................................................................... 4-4
4.2.4.2 Range Size ............................................................................................ 4-4
4.2.4.3 TCP Ports .............................................................................................. 4-4
4.2.4.4 Result List ............................................................................................. 4-4
4.2.4.5 Search ................................................................................................... 4-4
4.2.4.6 Clear ...................................................................................................... 4-4
4.2.5 Connection List ..................................................................................... 4-5
4.3 System .................................................................................................. 4-6
4.3.1 Info ........................................................................................................ 4-6
4.3.2 Production data ..................................................................................... 4-6
4.3.3 Settings ................................................................................................. 4-7
4.3.4 Special Settings .................................................................................... 4-8
4.3.5 Log ........................................................................................................ 4-9
4.3.6 Firmware download ............................................................................... 4-9
4.3.7 Restart ................................................................................................... 4-9
4.4 Display .................................................................................................. 4-10
4.4.1 Brightness ............................................................................................. 4-10
4.4.2 Backlight [min] ....................................................................................... 4-10
4.4.3 Rotation ................................................................................................. 4-10
4.4.4 Calibrate Touchscreen ........................................................................... 4-10
4.5 Keyboard ............................................................................................... 4-11
4.5.1 SIP (Virtual Keyboard) ........................................................................... 4-11
4.5.2 Name of the rst keyboard .................................................................... 4-11
4.5.3 Width of the Focus (in Pixels) ............................................................... 4-11
4.6 Password .............................................................................................. 4-12
4.7 Language .............................................................................................. 4-12
5 Localles/localserver
5.1 Connecting via FTP access................................................................... 5-1
5.2 INTFLASH/WEBPAGES ........................................................................ 5-2
6 Updating and special settings
6.1 Firmware update ................................................................................... 6-1
6.1.1 Additional information on downloading FW ........................................... 6-1
6.1.2 Secure Firmware Download via USB .................................................... 6-1
6.2 Reset / Resetting the device to factory settings .................................... 6-2
6.3 Backlight ................................................................................................ 6-2
6.4 Typefaces supported by MB panel PCD7.D4xx .................................... 6-3
6.5 Special Unicode fonts ........................................................................... 6-5
6.5.1 General information ............................................................................... 6-5
6.5.2 Multi-languages: Example ..................................................................... 6-7
6.5.3 Analysing incorrect fonts, font sizes or format templates ...................... 6-9
6.5.4 Web Editor ............................................................................................. 6-9
6.6 Internal special functions ....................................................................... 6-10
6.6.1 Container variable for WVGA MB panel ................................................ 6-10
6.6.2 uBT_BackLight Containerdiagramm ..................................................... 6-15
6.6.3 Additional uBTerminal container for "Save logs to File” function ........... 6-15
6.7 List of message box messages ............................................................. 6-16

0-3
Saia-Burgess Controls AG
27-621 ENG07 – Manual – Web Panel MB - PCD7.D450WTPx and PCD7.W470WTPx
Content
0
7 Handling: precautionary measures
7.1 Glass touchscreen ................................................................................ 7-1
7.2 Information on the LCDs of the MB panel display ................................. 7-1
7.3 Care ...................................................................................................... 7-1
8 General recommendations for the Web Editor 5
8.1 In the "Project congurations" ............................................................... 8-1
8.2 In the Web Editor project (general information) ..................................... 8-1
8.3 Denition of an object in the Web Editor ............................................... 8-2
8.4 Handling ................................................................................................ 8-2
8.5 Some rules regarding gif images .......................................................... 8-2
8.5.1 Decompression in the video cache at startup using the Gif list ............. 8-3
8.5.2 Decompression of Gif les in the video cache at startup
using a dummy start screen .................................................................. 8-4
8.5.3 Decompression of Gif les: analysis/calculation ................................... 8-4
8.6 Expanded error messages for the WVGA panel ................................... 8-5
8.7 Extended alarm macros ........................................................................ 8-5
8.8 Trend macros for MB panels with "save logs to les" ........................... 8-5
A Appendix
A.1 Icons ......................................................................................................A-1
A.2 Safety information .................................................................................A-2
A.3 Waste of Electrical and Electronic Equipment (WEEE) disposal ..........A-3
A.4 Contact ..................................................................................................A-4

0-4
Saia-Burgess Controls AG
27-621 ENG07 – Manual – Web Panel MB - PCD7.D450WTPx and PCD7.W470WTPx
Document versions | Brands and trademarks
Content
00.1 Documentversions
Version Published Redactor Remarks
ENG01 2013-06-21 ErDa First version of manual
ENG02 2013-07-31 HaMa Small changes
ENG03 2015-05-18 HaMa New translation from German
ENG04 2016-01-22 HaMa Changes for new xation set
ENG05 2018-07-20 HaMa Removed «uBT_Buzz..» from the table «uBT»
ENG06 2020-02-24
2020-03-06
HaMa
HaMa
New dimensions after “Value Engineering”
Last page - Partner Channel
ENG07 2020-08-19 HaMa Removed the Buzzer
0.3 Brands and trademarks
Saia PCD®and Saia PG5®
are registered trademarks of Saia-Burgess Controls AG.
Technical modications are based on the current state-of-the-art technology.
Saia-Burgess Controls AG, 2020. © All rights reserved.

1-1
Saia-Burgess Controls AG
27-621 ENG07 – Manual – Web Panel MB - PCD7.D450WTPx and PCD7.W470WTPx
Introduction
Quickstart
1
1 Quickstart
1.1 Introduction
This manual describes the technical aspects of the PCD7.D4xxWTPx Wide Screen
MB Panel. The objective of the “Quick Start” chapter is the quick installation of the
PCD7.D4xxxT5F components. You will nd information on:
■ Denition of the connectors
■ Power supply and consumption
■Dimensions
■Possible communications modes
Other chapters contain additional details regarding:
■ Hardware
■ Software (Setup menu step-by-step and conguration)
■ Usage, rmware update, etc.
■Maintenance
Supplementary manuals:
■PG5 2.0 User guide | 26-732
■ File System and FTP Server | 26-855
■ Ethernet TCP/IP | 26-766
■ Smart RIO PCD3.T665 | 26-892
■ Serial interface modules PCD7.F1xxx | 27-664

1-2
Saia-Burgess Controls AG
27-621 ENG07 – Manual – Web Panel MB - PCD7.D450WTPx and PCD7.W470WTPx
Denition of the connectors
Quickstart
1
1.2 Denitionoftheconnectors
PCD7.D450WTPx
Ethernet USB Power supplyReset button
Ground using screw M4 (cable lug)
or mounting plate 6.3 mm (FastOn) Fixation set
PCD7.D470WTPx
Ethernet USB Power supplyReset button
Ground using screw M4 (cable lug)
or mounting plate 6.3 mm (FastOn) Fixation set
Protective earth must be connected
Power supply Ground/Earth (-) / 24V (+) Connector, 2-pole
Communications 1× Ethernet 1× RJ 45 with LED display
USB Standard USB slave
Reset button Pushbutton

1-3
Saia-Burgess Controls AG
27-621 ENG07 – Manual – Web Panel MB - PCD7.D450WTPx and PCD7.W470WTPx
Voltage supply of the panel
Quickstart
1
1.3 Voltage supply of the panel
Pin Signal
124V (+)
2Earth (-)
Power supply:
→ 24 VDC +30% / –20%
or
→ 19 VAC ±15% current supply with full-wave rectier
Current consumption Power output without backlight
PCD7.D450WTPF
PCD7.D450WTPZ11
PCD7.D450WTPZxx
Max 350 mA 8 W
PCD7.D470DTPF
PCD7.D470DTPZ11
PCD7.D470DTPFZxx
Max 350 mA 8 W
Current supply with jack plug for cable of max. 1.5 mm2.

1-4
Saia-Burgess Controls AG
27-621 ENG07 – Manual – Web Panel MB - PCD7.D450WTPx and PCD7.W470WTPx
Dimensions and cut-out [in mm]
Quickstart
1
1.4 Dimensions and cut-out [in mm]
1.4.1 5" panel
40 5.6
Front panel W × H, 166 × 126
Display 5.0" W × H, 109.4 × 66.2
Cut-out W × H, 157 × 117
1.4.2 7" panel
44 5
Front panel W × H, 204 × 157
Display 7.0" W × H, 154.08 × 85.92
Cut-out W × H, 189 × 142

1-5
Saia-Burgess Controls AG
27-621 ENG07 – Manual – Web Panel MB - PCD7.D450WTPx and PCD7.W470WTPx
Installation of the panels
Quickstart
1
1.5 Installation of the panels
1.5.1 Installation in control cabinet
■ The mounting position is horizontal. Place the unit in the installation cut-out.
■ Make sure that the ventilation slots (at the top of the unit and on both sides) are
not covered to allow air to circulate.
■ Mount the 4 (or 6 for 7”) attachment parts. (2 on the device and 2 under the de-
vice and 2 on the sides for 7”). See the photo below.
4 × mounting clamps
6 × mounting clamps
Attachment parts of the PCD7.D450WTPx
Attachment parts of the PCD7.D470WTPx

1-6
Saia-Burgess Controls AG
27-621 ENG07 – Manual – Web Panel MB - PCD7.D450WTPx and PCD7.W470WTPx
Operation and handling of the touchscreen
Quickstart
1
Note:
■ The attachment parts can be mounted more easily if another user is holding
the panel at the front.
■ A 2.5 mm Allen key is required for the screws.
■ Turn the screws in the attachment parts until they lock onto the micro browser
and are not obstructed by the plate.
■ Fasten the attachment bracket on the panel and tighten the screws until they
touch the plate.
■ The required torque to seal the gasket is 20 cNm. Do not exceed 30 cNm to
avoid breaking of the clamp.
How to ensure spray water protection according to IP65:
The device must be mounted on a at surface or wall. Tighten the bolts until the
front plate of the PCD7.D4xx is just touching the mounting surface/wall.
1.6 Operation and handling of the touchscreen
To operate the touchscreen, use only your nger, the stylus or a soft nger stylus.
Do not use sharp tools (e.g., sharp metallic objects, paperclips or a screwdriver,
etc.).

1-7
Saia-Burgess Controls AG
27-621 ENG07 – Manual – Web Panel MB - PCD7.D450WTPx and PCD7.W470WTPx
Setting up communications for displaying a website
Quickstart
1
1.7 Setting up communications for displaying a website
1.7.1 HTTPDirectoverethernetRJ-45connector
The fastest communication connection is the Ethernet port via RJ 45 if the HTTP
direct proto-col is selected. The speed is either 10 Mbit/s or 100 Mbit/s with an Auto-
Negotiation protocol via the connected device.
Connectiontoexternaldevices
The HTTP connection can be established between our PCD7.D4xx and any Saia
PCD control-ler if there is an Ethernet connection to the automation server.
Ethernet http direct
Quick test of the WVGA panel
■ A web application must rst be loaded into the Saia PCD that was created with
the Web Editor (see 26-838_Manual_Web-Editor). Ask the SBC Support team for
some examples. They will also soon be available on our website.
■ With a CAT5 cable, you can connect the display PCD7.D4xx to the Saia PCD.
The display supports auto-crossing so that a crossover cable is no longer re-
quired.
■ Dening the HW settings of the Saia PCD with the PG5: The S-Bus support
must be selected together with the TCP/IP channel in which a valid IP address
must be en-tered.
Setup settings of the WVGA panel:
Congure the WVGA panel by opening the setup menu (see chapter 4):
■ First make sure that they are in the same subnet of the network as the PCD. An
exam-ple: If the Saia PCD IP address is 192.168.12.92, enter an IP address such
as 192.168.12.90 at your terminal (in the network menu) as the subnet mask is
normally 255.255.255.0.
■ In the conguration menu, enter the address of the start page that corresponds
to the IP address of the Saia PCD and also the name of the HTML start page.
Now the MB panel should be connected to the Saia PCD and the selected start
page should be displayed on the monitor. Now you can navigate through your web-
sites!

1-8
Saia-Burgess Controls AG
27-621 ENG07 – Manual – Web Panel MB - PCD7.D450WTPx and PCD7.W470WTPx
Setting up communications for displaying a website
Quickstart
1
1.7.2 USBportasserviceport
This port is generally used as a service port with the WVGA standard MB panels. It
is mainly used to load new rmware into the device.
The USB port complies with the USB 1.1 specication. Highest speed: 12 Mbit/s.
1.7.3
Accessing the web editor on the Micro Browser Panel PCD7.D4xx
Detailed documentation can be downloaded from our website. See manual 26-838
Manual Web-Editor. To access the programming of the MB panel, you must note
some special features:
■ When creating a new project and receive no help from the assistant, you must
congure the project as follows:
● Use of the virtual keyboard with WVGA MB panels, see "4.5 Keyboard" on
page 4-11
● If you want to use the le Background.teq or foreground.teq, you should rst
create these les. The reason for this is… These les are rst positioned on
each page be-fore any objects or texts and elds appear
● Once the project is ready for download, enter the relevant HTML le name and
create a build project. Now execute a web server build in the Saia PG5 project
manager so that all les access the PCD. If you only want to access the PCD
with the MB panel PCD7.D4xx and not a PC browser, you can reduce the data
quantity by deleting the .jar les as they are already available on the panel.

2-1
Saia-Burgess Controls AG
27-621 ENG07 – Manual – Web Panel MB - PCD7.D450WTPx and PCD7.W470WTPx
Technical data of the WVGA MicroBrowser panel
Technical data
2
2 Technical data for the two panel types
2.1 Technical data of the WVGA MicroBrowser panel
HMI - Line Base Base
Type PCD7.D450WTPF,
PCD7.D450WTPZ11
PCD7.D470WTPF,
PCD7.D470WTPZ11
Display
Display size 5" TFT 7" TFT
Resolution (pixels) WVGA 800 × 480 WVGA 800 × 480
Colours 65,536 65,536
Adjustable contrast Yes
Background lighting LED (dimmable in 20 stages)
Touch Screen Resistive 4-wire
CPU
Processor Coldre CF5373L / 240 MHz
Memoryforlocallesystem 128 MB
Real-time clock (RTC) Yes with Super-Cap
Interfaces
Ethernet 1× Ethernet Interface RJ 45 / http direct
USB 12M 1× Client
Serial ---
Operating system Saia PCD®COSinus
Browser Saia PCD® Micro Browser
Server FTP server
Software tools
Graphic editor Web Editor 8 and 5
Use of PG5 resources Yes
Technical data
Power supply 18…32 VDC
Current draw 350 mA 400 mA
Housing protection type
(front)
IP65
Operating temperature 0 … 50 °C –20 … 70 °C
Storage temperature –20 … 70 °C
(non-condensing)
–25 … 70 °C
(non-condensing)
Dimensions (W×H×D ) [mm] 166 × 127 × 45.6 204 × 157 × 49
Cut-out (W×H) [mm] 157 × 117 189 × 142
Display size (W×H) [mm] 109.4 × 66.2
Display size (W×H) [mm]
up to HW: <F
152 × 91.44
Display size (W×H) [mm]
starting with HW: ≥F
154.08 × 85.92

2-2
Saia-Burgess Controls AG
27-621 ENG07 – Manual – Web Panel MB - PCD7.D450WTPx and PCD7.W470WTPx
Technical data of the WVGA MicroBrowser panel
Technical data
2

3-1
Saia-Burgess Controls AG
27-621 ENG07 – Manual – Web Panel MB - PCD7.D450WTPx and PCD7.W470WTPx
Open setup menu
Operating the setup menu
3
3 Operating the setup menu of the WVGA MB panel
This chapter describes the menu structure of the WVGA Micro Browser Panel
Micro Browser WVGA Panel
● PCD7.D450WTPF (5.0” WVGA)
● PCD7.D450WTPZ11 (5.0” WVGA)
● PCD7.D470WTPF (7.0” WVGA)
● PCD7.D470WTPZ11 (7.0” WVGA)
3.1 Open the Setup menu
SAIA BURGESS CONTROLS
Call up setup menu:
Îby pressing and holding any area for 4 seconds at any time (buttons excluded)
Îby pressing on the icon depicted while booting up (see section “3.2 Customising
the start screen” on page 3-2)
Îthe SETUP menu also includes an ONLINE function help (press the Help icon)

3-2
Saia-Burgess Controls AG
27-621 ENG07 – Manual – Web Panel MB - PCD7.D450WTPx and PCD7.W470WTPx
Customising the start screen | Changing the password
Operating the setup menu
3
3.2 Customising the start screen
The title screen is displayed for a few seconds, immediately after the panel is
switched on with ON. The greeting and welcome screen can be dened under
System Start screen (see “4.3.3 Settings” on page 4-7).
Available for a few seconds only,
pressing on this icon will take you
directly to the Setup menu.
= Animated icon for “Please wait, data is being loaded”
User-dened System Start screen: “4.3.3 Settings” on page 4-7.
3.3 Changing the password
MB panels of the PCD7.D4xxxx series are supplied without a password on the
Setup menu.
However if ac-cessing the setup menu was restricted with a password, the correct
password must be en-tered and conrmed with OK.
ÎFor information on entering passwords, see “4.6 Password” on page 4-12.

3-3
Saia-Burgess Controls AG
27-621 ENG07 – Manual – Web Panel MB - PCD7.D450WTPx and PCD7.W470WTPx
Saving and exiting
Operating the setup menu
3
3.4 Savingandexiting
If you have changed one or more parameters, you must conrm if you want to save
the changes, to save & reboot, or to reset the new parameters without saving.

3-4
Saia-Burgess Controls AG
27-621 ENG07 – Manual – Web Panel MB - PCD7.D450WTPx and PCD7.W470WTPx
Saving and exiting
Operating the setup menu
3
This manual suits for next models
7