Scheiber BLOC 9 User manual

SCHEIBER
2 Bellevue, 85120 Saint-Pierre du Chemin •France
Phone : +33 (0)2 51 51 73 21 •clients@scheiber.fr •sav@scheiber.fr •www.scheiber.fr
Domotique embarquée
Embedded home automation
Domotique embarquée
Embedded home automation
Acknowledgement...................................................P.2
Safety Warnings.........................................................P.2
Accessories / Associated references.................P.2
Equipment description..........................................P.3
Technical characteristics........................................P.4
Electrical characteristics.........................................P.4
Description of the markings used.....................P.4
Installation instructions..........................................P.6
Connection..................................................................P.6
Wiring............................................................................P.7
Operation....................................................................P.8
IBS sensor....................................................................P.8
Troubleshooting guide...........................................P.9
Terms and conditions.............................................P.10
Warranty terms.........................................................P.10
User Manuel & Troubleshooting Guide
BLOC 9
Réf : 41.70509.01

Domotique embarquée
Embedded home automation
P. 2
Domotique embarquée
Embedded home automation
Acknowledgement
We thank you for your purchase and hope that you are fully satised with this product.
Before you use this product, we recommend you read the instructions below carefully.
This manual explains how to use and install the product in accordance with its intended use.
Safety Warnings
WARNING: Do not disassemble the device
Any contact with the product's internal components can cause injury. In the event of a malfunction, only a qualied technician is
authorised to repair the device
WARNING: In the event of impact
If the product falls or undergoes heavy impact, immediately contact a qualied person to ensure the device is working correctly
WARNING: Unpacking the equipment
After unpacking the product, make sure that it is complete and in good condition. If you are not sure, immediately contact a person
with the required professional qualication
WARNING: Unpacking the equipment
Do not leave any part of the packaging within the reach of children or vulnerable adults
Accessories / Associated references
Designation Reference
120Ω BUS CAN Termination 0D.CRD399
CAN cable (length available from 0.2m to 15m) 0D.CRD470 - 486
LIN cable (length available from 0.4m to 15m) 0D.CRD570 - 585
Power cable (length available from 1, 5 or 10m in 6mm²) 0D.CRD212.010 ou .050 ou .100
Quick connectors
(be careful, some references are sold with the connectors)
62.SAC13004A00
Labels (10x10mm) On demand

Domotique embarquée
Embedded home automation
P. 3
Domotique embarquée
Embedded home automation
The power bloc can control up to 6 functions
With this box, it's possible to :
- Centralize power commands of 6 electrical functions.
- Provide electrical protection for each output.
- View the status of each system through status LED.
- Physically troubleshoot each order in the event of an electronic failure.
- Receive data from 6 IBS sensors (Intelligent Battery Sensor).
- Integrate into a MULTIBLOC compatible network, and therefore be controlled by equipment of the type:
• NAVICOLOR display.
• WIFI server.
• Multiplexed switch module.
A forced operation of each output is possible using a bypass fuse (2 fuses are supplied : 15A et 25A).
The 6 power outputs are adjustable from 3 to 25A and can control 12/24 DC networks like:
- interior lights,
- navigation instruments,
- navigation lights,
- the pumps,
- comfort devices,
- etc, ...
Several modules (Bloc 9 can be installed side by side depending on the number of functions to be controlled.
Integration in a Multibloc Network
One or more Blocs 9 can be integrated in a MULTIBLOC network. A NAVICOLOR display can then be used to:
- Congure the Bloc 9 outputs
- Control the outputs
- Read the output status
- Read the IBS measurements of battery status.
This network is provided through the CAN bus.
The various Blocs 9 in the network are differentiated via the MICROSWITCH which can be used to allocate anumber in the network.
Additional function of Bloc 9 when integrated into a Multibloc network:
Fuel transfer
Associated with a Bloc 7 and a Navicolor, Bloc 9 allows operation of pumps to make fuel transfers form one tank to another one directly
from the touch screen.
Equipment description
LED Status
One LED per function indicates the status of the system:
- LED off: the circuit is inactive.
- LED on: the circuit is active.
Troubleshooting
The Bloc 9 has 6 fuse holders (for Mini Blade Fuse) to install the bypass for each circuit.
This solution allows each output to be overridden if there is a major failure of
the electronic system.
Electrical protection
The Bloc 9 provides electrical protection for your systems:
- Rating adjustable from 3 to 25 A according to your needs
- Reverse polarity protection (+/- battery inversion)
- Current surge protection.
Management of IBS sensors
The bloc 9 can manage up to 6 IBS which can
transmit the following battery information:
- Voltage
- Incoming and outgoing current
- Charge and discharge current
- Battery temperature
- Residual capacity
- Ageing.
The IBS are connected to the bloc 9 through the LIN
bus. Measurements are read and alerts congured
through a NAVICOLOR display.

Domotique embarquée
Embedded home automation
P. 4
Domotique embarquée
Embedded home automation
BLOC 9
REFERENCE 41.70509.01
POWER SUPPLY 8-32 V DC up to 16 mm2
DETAILS AND FEATURES OF THE INPUTS - 2 x CAN connectors type 6-way Micro-Fit
- 1 x LIN connector type 4-way Micro-Fit
DETAILS AND FEATURES OF THE OUTPUTS - 6 adjustable power outputs in current from 3 to 25A.
- 2 x connectors 6-way in 6mm² max.
BYPASS FUSE (SUPPLIED)
15A (blue) 25A (brown)
Check that the cable section is sufcient depending on the size of
the fuse used
LIN BUS To manage up to 6 IBS sensor
CAN BUS 2 x connectors type 6-way Micro-Fit
ENVIRONMENTAL CONDITIONS
Indoor use
Altitude up to 2000m
Operating temperature: 0 to +50 °C
Relative humidity: 0 to 93% - non-condensing
Protection index: IP20
MOUNTING Organize a panel cut-out 84,50 x 125,50 mm and 2 screws support
MOUNTING DISTANCE 138 mm
MECHANICAL ABS Box UL94-V0
WEIGHT 0,19 Kg
STANDARDS EN 60945
FIRMWARE VERSION V7.21 or higher
DIMENSIONS (LxWxH) 150 x 95 x 69,6 mm (with socket mounted)
Technical characteristics
INPUT RATED VOLTAGE (VDC)8-32 V DC
OUTPUT RATED VOLTAGE (VDC)equal to the input voltage
SELF-CONSUMPTION 60 mA max.
MAXIMUM CURRENT PER OUTPUT adjustable from 3 to 25A
MAXIMUM CUMULATIVE CURRENT 50A
Electrical characteristics
Description of the markings used
VVolt
AAmpere
ou DC Direct current

Domotique embarquée
Embedded home automation
P. 5
Domotique embarquée
Embedded home automation
Front view
Side view
(connector mounted)
Back view
55,3
23,5
14,3
95
84,50
150
138
125,50
3,20
(-) S3
(+) S3
(-) S2
(+) S2
(-) S1
(+) S1
Plug
1
Power
connector
Plug
2
(-) S6
(+) S6
(-) S5
(+) S5
(-) S4
(+) S4
X3 LIN BUS X2 CAN BUS
X1 CAN BUS
Bypass fuse bracket
S1
S2
S3
S4
S5
S6
Bypass fuses
Microswitch
Control button
Output status LED
-
+
Location of
the labels
Block status LED

Domotique embarquée
Embedded home automation
P. 6
Domotique embarquée
Embedded home automation
Installation instructions
• This device must be placed in a place protecting it from any risk of water splashing. Install in a ventilated location
• Do not install on supports that are sensitive to heat, such as carpet or PVC ooring, etc.
• The product must be installed away from heat and humidity
Meaning of the LEDs:
- LED off: the circuit is inactive.
- LED on: the circuit is active.
!WARNING: Connection/disconnection with power on
Do not perform connection or disconnection with power on.
INPUT / POWER SUPPLY
Type of connection
Cross section
Clip 8mm + connector 2-way
de 6 à 16 mm²
OUTPUT
Type of connection
Cross section
2 x spring connectors 6-way
6 mm²
CAN BUS 2 x CAN connectors type 6-way Micro-Fit
LIN BUS 1 x LIN connector type 4-way Micro-t
CODAGE With DIP SWITCH
PROTECTION TO BE PROVIDED ON THE SUPPLY LINE
Protection rating
Protection location
Fuse or circuit breaker 50A maximum
Accessible and identied for the user
Connection
Mounting:
95
84,50
150
138
125,50
3,20
Installation cutouts:
84,50 x 125,50 mm
Mounting distance :
45 x 138 mm
Mounting distance of the 2 screws support :
138 mm
Visible thickness after mounting :
14,3 mm
Back clearance zone for connection :
80 mm (behind the product)
47,5
6

Domotique embarquée
Embedded home automation
P. 7
Domotique embarquée
Embedded home automation
Wiring
12
3
5
Allocate a number to the module 9 using the microswitches. Connect the cables of the equipment to be controlled to
the quick connectors, complying with the numbering on
the "BACK VIEW" diagram.
Connect quick connectors on plugs 1 & 2
Connect the LIN bus to the IBS Connect the power plug
4Connect either a connection cable with another device or a
120 Ω termination to each CAN connector.
2.4 Ghz
Terminaison 120 Ω
liaison CAN
S4
S3
S2
S1
S5
S6
DC
AC
Alimentation 230V AC 8-32V DC
6
Microswitch
Front view
Back view
Plug 1 Plug 2
IBS sensor
Towards power
supply
Example :
1 2 3 4
OFF
Allocate number 3
ON
120 Ω termination
CAN cable

Domotique embarquée
Embedded home automation
P. 8
Domotique embarquée
Embedded home automation
Operation
Bloc 9 can be congured from:
- a NAVICOLOR display
- a PC with MULTICOM software and its CAN / USB interface
- the WiFi server conguration interface
- a CAN / CAN SD interface with a conguration created from the Scheiber conguration software.
CONFIGURATIONCONFIGURATION
When switching on, check that the MULTIBLOC devices are connected to each other by the CAN network and correctly supplied. The two 120 Ω
terminations must also be correctly placed.
Check for each function that:
- The control keys (ON / OFF) are used to control each of the outputs.
- Bypass fuses are used to activate each function.
If your network has a NAVICOLOR type front panel, check that:
- The facade allows to control each of the outputs.
If your network has a NAVICOLOR type front and IBS sensors are mounted on Block 9 check that:
- The front panel allows the values of the batteries to be read and that these values are in accordance with the expected results.
For any problems encountered please consult the chapter "TROUBLESHOOTING GUIDE"
IBS sensor
How to read the measurements of an IBS sensor?
The NAVICOLOR panel displays the status of the batteries using the following information:
Voltage
Current
Health
Battery
temperature
Battery
number
State of charge
*Image not contractual

Domotique embarquée
Embedded home automation
P. 9
Domotique embarquée
Embedded home automation
Troubleshooting guide
Detach the Bypass fuse and connect it to the fuse holder 3
In order to force the electrical function in the event of any malfunction of Bloc 9, you must install the Bypass fuse on the output concerned.
In the following example we force exit S3 from Bloc 9.
S3 output
Bypass fuse 3 bracket
1
2
Bypass fuse
3
Remove the front cover
Locate the fuse holder corresponding to output 3

Domotique embarquée
Embedded home automation
P.10
Domotique embarquée
Embedded home automation
Terms and conditions
The manufacturer cannot be held responsible and accepts no responsibility in the event of harm to persons or property due to
improper use and in reference to the warnings provided in this manual.
SCHEIBER reserves the right to change the characteristics of its products in the interest of its customers. The manual supplied with this
product must not be reproduced, transmitted, stored in a search system or translated into any language, in full or in part, by any means,
without the prior written consent of SCHEIBER.
Although every effort has been made to provide you full and accurate information in this manual we ask that you inform the SCHEIBER
representative of your country in case of any error or omission we may have overlooked.
SCHEIBER reserves the right to change the characteristics of the hardware and software described in these manuals at any time and
without prior notice.
WARRANTY SUBJECT:
The company SCHEIBER warranties all its products’ range against failures or masked-failures according to the article 1641 and followings
of the Civil Code. Repairs and replacement of the equipment during the warranty period do not change terms or time of this warranty
which is of 2 years. Repairs and replacement of the faulty parts under warranty are made only on presentation of the invoice which
certies the warranty beginning date.
WARRANTY DOES NOT APPLY:
This warranty can not be applied in case of misuse, wrong installation, repair by anyone else than a SCHEIBER authorised technician,
damage arising from improper use (fuses replaced by another value), utilisation in an unsuitable environment or if the equipment has
suffered from physical damages through handling, transport. It does not cover calibration or verication due to the normal age of the
components. Warranty modalities: The equipment freight will be charged to the customer. If the returned equipment is not conform,
our company considers it has the right to refuse the free repair and proposes an estimate.
RESPONSIBILITY LIMITS:
In any case, the company SCHEIBER will not be held responsible for direct damages or damages not due to the normal use of the
equipment. In case of a dispute arising between the parties, the case shall be submitted to the French Right to the court specied by
the company SCHEIBER.
Warranty terms & after-sales

2 Bellevue,
85120 • Saint-Pierre du Chemin
France
Phone : +33 (0)2 51 51 73 21
sav@scheiber.fr
www.scheiber.fr
Question ?
contact@scheiber.fr
Problem ?
sav@scheiber.fr
L’innovation française depuis 1965
This manual suits for next models
1
Table of contents
Popular Control Unit manuals by other brands

Siemens
Siemens SIMADYN D FM 458 user manual

SICK
SICK CMP400 Fitting instructions

Texas Instruments
Texas Instruments LM5123EVM-BST user guide

VAT
VAT 590 Series Installation, operating, & maintenance instructions

Festo
Festo MS6N-SV Assembly Installation Safety Instructions

Viessmann
Viessmann 5215 operating instructions

System Sensor
System Sensor i3 Series Installation and maintenance instructions

Graco
Graco ProMix 2KS Operation manuals

Danfoss
Danfoss PVG 100 Service manual

Grundfos
Grundfos Vaccuperm VGS -141 Installation and operating instructions

SRA
SRA iPAMM installation manual

WEG
WEG SSW900-CDN-N Installation, configuration and operations guide