Message Meaning Action Required
No message in display. The Topside Panel will be disabled until power
returns. Spa settings will be preserved until the
next power up.
Temperature unknown. After the Circulation Pump has been running for
2 minutes, the temperature will be displayed.
‘Overheat' - The Spa has shut down. DO NOT ENTER THE WATER. Remove the Spa
One of the sensors has detected Cover and allow water to cool. Once the Heater
48oC at the Heater. has cooled, reset by pushing any button.
If Spa does not reset, shut off the power to the Spa
and call your Dealer or Service Organisation.
Sensors are out of balance. If the problem persists, contact your Dealer or
If alternating with temperature, Service Organisation.
it may just be a temporary condition,
if flashing by itself, Spa is shut down.
A substantial difference in temperature Check water level in Spa. Refill if necessary.
has been detected between temperature If the water level is correct, make sure the Pumps
sensors. This could indicate a low have been primed. Turn Spa off, take out and clean
flow problem. the filters with filter cleaner. Turn Spa back on
again to restore heating. If problem persists,
contact your Dealer or Service Organisation.
Inadequate water detected in Heater. Check water level in Spa. Refill if necessary.
If the water level is correct, make sure the Pumps
have been primed. Press any button to reset.
When the Spa is first activated it will
Priming Mode will last for up to 4 minutes and
then the go into Priming Mode. Spa will begin to heat and maintain the water
temperature in the Standard Mode.
SETTING ‘F’ (FILTRATION) CYCLES
The first filter cycle begins 6 minutes approximately
after the Spa is energised. The second filter cycle
begins 12 hours later. Filter duration is programmable
for 2,4,6, 8 hours or for continuous filtration (indicated
by ‘FC'). The default filter time is 2 hours. If Circulation
Pump is used the purpose of the filtration cycles are
only to conduct heating in SL and Ec Modes.
At the beginning of each filter cycle the Blower purges
for 30 seconds; the Pump purges for 5 minutes.
1. PRESS TEMP BUTTON and then
2. PRESS JETS 2 BUTTON
3. Either
F2 - 2 hours x 2 times per day
F4 - 4 hours x 2 times per day
F6 - 6 hours x 2 times per day
F8 - 8 hours x 2 times per day
FC - Filtration Continuously
Will be displayed on the LCD Screen.
4. PRESS TEMP BUTTON again to change ‘F'
Cycle hours.
5. PRESS JETS 2 BUTTON once you have selected the
desired ‘F' Mode.
Warning! Shock Hazard! No user Serviceable Parts.
Do not attempt service of this control system. Contact your Dealer or Service Organization for assistance. Follow all owner's manual power
connection instructions. Installation must be performed by a licenced electrician and all grounding connections must be properly installed.
SCS Industries Pty Ltd 6-16 Keppel Drive, Hallam Victoria 3803 Australia Ph: 61 3 9702 3144