SCS Static Monitor 790 User manual

TB-9015 Page 1 of 7 © 2015 DESCO INDUSTRIES, INC.
Employee Owned
SCS -5,QGXVWULDO'ULYH6DQIRUG1&:HEVLWHStaticControl.com
Static Monitor 790
Installation, Operation and Maintenance
Description
The SCS Static Monitor 790 is designed to monitor the
operation of two wrist strap grounding systems and the
ground connection of a specified equipment chassis.
7KLVSURGXFWKDVEHHQGHVLJQHGDQGWHVWHGIRULQGRRU
XVHRQO\DQGZLWK6&6'XDO&RQGXFWRU:ULVWEDQGV
2300VM Series and SCS Dual Conductor Ground Cord
2300 Series. The monitor operates from a 120VAC
adaptor that is included in the North America version.
2XWVLGH1RUWK$PHULFDREWDLQDQDSSURSULDWH$&
adapter meeting the specifications. The product has not
EHHQWHVWHGRUSURYHQVDIHIRURWKHUXVHV
1RWH6&6'XDO&RQGXFWRU&RUGV:ULVWEDQGV
2300VM Series are required for use with the Static
Monitor 790, ordered separately.
Meets requirements of ANSI/ESD S20.20 and
UHFRPPHQGDWLRQVRI(6'+DQGERRN(6'75
ZKLFKLQFOXGHV³LIWKHSURGXFWVWKDWDUHEHLQJSURGXFHG
DUHRIVXFKYDOXHWKDWNQRZOHGJHRIDFRQWLQXRXV
UHOLDEOHJURXQGLVQHHGHGDQGWKHQFRQWLQXRXV
PRQLWRULQJVKRXOGEHFRQVLGHUHGRUHYHQUHTXLUHG´
June 2015
USER GUIDE TB-9015
Figure 1. SCS Static Monitor 790.
Figure 2. SCS Static Monitor 790 Kit.
AC Adapter Mounting
SCS Static Monitor 790
Chassis/
Ground
Cords with
7ZR:LUH
Connector
Theory of Operation
The SCS Static Monitor 790 is designed to continuously
PRQLWRUWKHYROWDJHOHYHORQDQRSHUDWRUVXVLQJD
high impedance voltage measurement circuit. The
measured operator’s voltage is compared to one of four
XVHUVHOHFWDEOH999DQG9LQWHUQDOUHIHUHQFH
voltages. An alarm will sound with a corresponding
UHGIODVKLQJODPSVZKHQDQRSHUDWRU¶VYROWDJHOHYHO
FDXVHGE\VWDWLFJHQHUDWLRQH[FHHGVWKHVHOHFWHG
LQWHUQDOUHIHUHQFHYROWDJH,QDGGLWLRQDZULVWEDQG
contact detection circuit is also employed to let the user
NQRZLIWKHZULVWEDQGLVEHLQJZRUQLPSURSHUO\RUKDV
H[SHULHQFHGDORVVRIFRQWLQXLW\EHWZHHQWKHJURXQG
FRUGDQGZULVWEDQG
The ground connection of the Static Monitor 790 is
continuously monitored through a low DC current-loop
measurement circuit. The ground connection of an
HTXLSPHQWFKDVVLVFDQDOVREHPRQLWRUHGZKHQ
connected in series with the monitor’s ground
measurement circuit. An alarm will sound with
corresponding red lamps, when this loop resistance
H[FHHGVRKPV
If all monitored components are operating within the
selected operating parameters of the Static Monitor 790,
a green lamp will illuminate.
The Static Monitor 790 uses a modified version of the
6&6'XDO&RQGXFWRU:ULVWEDQG906HULHVDQGWKH
VWDQGDUG6&6'XDO&RQGXFWRU*URXQGLQJ&RUG6HH
$FFHVVRULHV6HFWLRQ
*Voltage alarm levels ±15%
**Ground disconnect ±20%
&$87,217KH6&66WDWLF0RQLWRUGRHVQRWKDYH
WKHFDSDELOLW\RIYHULI\LQJWKDWWKHJURXQGSRLQWLVD
VXLWDEOHJURXQG,I\RXDUHQRWVXUHZKDWDVXLWDEOH
JURXQGLVFRQWDFWDOLFHQVHGHOHFWULFLDQEHIRUH
installation.

TB-9015 Page 2 of 7 © 2015 DESCO INDUSTRIES, INC.
Employee Owned
SCS -5,QGXVWULDO'ULYH6DQIRUG1&:HEVLWHStaticControl.com
Attaching Ground and Chassis Cords
7RROVUHTXLUHG±6PDOOEODGHVFUHZGULYHU
Refer to Figures 3 and 4 for this section.
Two-Wire Connector
AC Adapter Ground Wire
AC Adapter
DC Plug
790 Chassis/Ground Cord
Attach 3M™Static Monitor 790
Chassis/Ground Cord or AC Adapter
Ground Wire
7ZR:LUH&RQQHFWRU
*
AC Adapter
*URXQG:LUH
*
DC Plug
AC Adapter
Attach 790 Chasis/Ground
Cord or AC Adapter
*URXQG:LUH
*
*
*790 Chasis/Ground Cord
AB
Figure 3. Attachment of Ground Cords.
1RWH3HUIRUP6WHSEHORZZKHQPRQLWRULQJGLUHFWO\WR
WKHJURXQGFRQQHFWLRQ)LJ$3HUIRUP6WHSZKHQ
monitoring the ground connection through a grounded
FKDVVLV)LJ%
Installation of Static Monitor 790 with Chassis
Terminal Connected Directly to Earth/Electrical
Ground
Determine how you want to ground the Static Monitor
D,I\RXDUHJURXQGLQJWKH6WDWLF0RQLWRUWKURXJK
WKH:LUH$&DGDSWRU1RUWK$PHULFDVXSSOLHG
SHUIRUPWKHIROORZLQJVWHSV
$WWDFKWKHWLQQHGJURXQGZLUHRIWKH$&
adaptor to the ground terminal of the two-wire
FRQQHFWRUE\LQVHUWLQJLWLQWRWKHRSHQLQJDQG
securing with screwdriver.
$WWDFKRQHRIWKHVXSSOLHG6WDWLF0RQLWRU
&KDVVLV*URXQG&RUGVWLQQHGHQGWRWKH
chassis terminal of the twowire connector in
the same manner.
$WWDFKWKHULQJWHUPLQDOHQGRIWKH&KDVVLV
Ground Cord to an earth/electrical ground with
DVFUHZQRWVXSSOLHG
3OXJWKHWZRZLUHFRQQHFWRULQWRWKHMDFNDWWKH
rear of the Static Monitor 790.
E,I\RXDUHJURXQGLQJWKH6&66WDWLF0RQLWRU
through a Chassis/Ground Cord perform the following
VWHSV
$WWDFKRQHRIWKHVXSSOLHG&KDVVLV*URXQG
&RUGVWLQQHGHQGWRWKHJURXQGWHUPLQDORI
WKHWZRZLUHFRQQHFWRUE\LQVHUWLQJLWLQWRWKH
opening and securing with screwdriver.
$WWDFKWKHRWKHU&KDVVLV*URXQG&RUGWRWKH
chassis terminal of the two-wire connector in
the same manner.
$WWDFKWKHULQJWHUPLQDOHQGVRIERWKFRUGV
VHSDUDWHO\ZLWKWZRVFUHZVQRWVXSSOLHGWRDQ
earth/electrical ground.
3OXJWKHWZRZLUHFRQQHFWRULQWRWKHMDFNDWWKH
rear of the Static Monitor 790.
&$87,21:KHQXVLQJWZR&KDVVLV*URXQG&RUGV
DWWDFKHDFKRIWKHFRUGVWRVHSDUDWHJURXQGERQGLQJ
SRLQWV%\DWWDFKLQJWKHFRUGVWRWKHVDPHJURXQGEXW
DWGLIIHUHQWSK\VLFDOORFDWLRQVWKHPRQLWRUFDQFKHFNIRU
loose or lost connections.
3M™Static Monitor 790 Connected
Directly to Ground
3M™Static Monitor 790 Connected through
Equipment Chassis Ground
Rear of 790 Monitor
AC Adapter
Ground Wire
or Chassis/Ground
Cord
AC Adapter
Ground Wire
or Chassis/Ground
Cord
Chassis/Ground
Cord Chassis/GroundCord
Electrical Ground
Existing Equipment
Ground Wire
790 Connected
Directly to Ground 790 Connected through
Equipment Chassis Ground
Rear of
790 Monitor
AC Adapter
*URXQG:LUH
or Chassis/
Ground Cord
Chassis/
Ground Cord
Electrical Ground
AC Adapter
*URXQG:LUH
or Chassis/Ground
Cord
Chassis/Ground Cord
([LVWLQJ(TXLSPHQW
*URXQG:LUH
AB
Figure 4. SCS Static Monitor 790 Connected Directly to
Ground or Through Equipment Chassis Ground.
Installation of SCS Static Monitor 790 with Chassis
Terminal Connected to a Grounded Equipment
Chassis
Determine how you want to ground the Static Monitor
D,I\RXDUHJURXQGLQJWKH6WDWLF0RQLWRUWKURXJK
the 3-wire AC adaptor supplied, perform the following
VWHSV
$WWDFKWKHWLQQHGJURXQGZLUHRIWKH$&
adaptor to the ground terminal of the two-wire
FRQQHFWRUE\LQVHUWLQJLWLQWRWKHRSHQLQJDQG
securing with screwdriver.
$WWDFKRQHRIWKHVXSSOLHG&KDVVLV*URXQG
&RUGVWLQQHGHQGWRWKHFKDVVLVWHUPLQDORI
the two-wire connector in the same manner.
$WWDFKWKHULQJWHUPLQDOHQGRIWKH&KDVVLV
Ground Cord to the equipment chassis with a
VFUHZQRWVXSSOLHG
3OXJWKHWZRZLUHFRQQHFWRULQWRWKHMDFNDWWKH
rear of the Static Monitor 790.
E,I\RXDUHJURXQGLQJWKH6WDWLF0RQLWRUWKURXJKD
&KDVVLV*URXQG&RUGSHUIRUPWKHIROORZLQJVWHSV
$WWDFKRQHRIWKHVXSSOLHG&KDVVLV*URXQG
&RUGVWLQQHGHQGWRWKHJURXQGWHUPLQDORI
WKHWZRZLUHFRQQHFWRUE\LQVHUWLQJLWLQWRWKH
opening and securing with screwdriver.
$WWDFKWKHRWKHU&KDVVLV*URXQG&RUGWRWKH
chassis terminal of the two-wire connector in
the same manner.

TB-9015 Page 3 of 7 © 2015 DESCO INDUSTRIES, INC.
Employee Owned
SCS -5,QGXVWULDO'ULYH6DQIRUG1&:HEVLWHStaticControl.com
$WWDFKWKHULQJWHUPLQDOHQGRIWKH&KDVVLV
Ground Cord connected to the ground terminal
RIWKHWZRZLUHFRQQHFWRUZLWKDVFUHZQRW
VXSSOLHGWRDQHDUWKHOHFWULFDOJURXQG
$WWDFKWKHULQJWHUPLQDOHQGRIWKH&KDVVLV
Ground Cord connected to the chassis ground
terminal of the two-wire connector, with a
VFUHZQRWVXSSOLHGWRDQHTXLSPHQWFKDVVLV
3OXJWKHWZRZLUHFRQQHFWRULQWRWKHMDFNDWWKH
rear of the Static Monitor 790.
&$87,21:KHQXVLQJWZR&KDVVLV*URXQG&RUGV
DWWDFKHDFKRIWKHFRUGVWRVHSDUDWHJURXQGERQGLQJ
SRLQWV%\DWWDFKLQJWKHFRUGVWRWKHVDPHJURXQGEXW
DWGLIIHUHQWSK\VLFDOORFDWLRQVWKHPRQLWRUFDQFKHFNIRU
loose or lost connections.
Attaching the SCS Static Monitor
790 to a Workbench or Equipment
Chassis
Figure 5. Attachment of Mounting Plate to SCS Static
Monitor 790.
Figure 6. SCS Static Monitor 790 attached to
workbench.
Figure 7. SCS Static Monitor 790 attached to equipment
chassis.
Refer to Figures 5, 6, and 7
Locate the Mounting Plate.
$WWDFKWKH0RXQWLQJ3ODWHLQWKHGHVLUHGORFDWLRQXVLQJ
RQHRIWKHIROORZLQJPHWKRGV
D)RDPWDSHDOUHDG\DSSOLHGWRWKH0RXQWLQJ
3ODWH&OHDQWKHVXUIDFHWREHPRXQWHGWR
with isopropyl alcohol. Remove release liner
IURPWDSHEHIRUHPRXQWLQJ
E7ZRSDQKHDGPDFKLQHRUZRRGVFUHZV
QRWVXSSOLHG
$WWDFKWKH6WDWLF0RQLWRUWRWKHPRXQWHGSODWHDV
shown in Figure 5. Align the plate with the opening on
WKHERWWRPRIWKHPRQLWRUDQGVOLGHIRUZDUGRQWRSODWH
until it latches.
,QSXW-DFN ,QSXW-DFN
OK Lamp
Fault Lamps
Figure 8. Front of SCS Static Monitor 790
Voltage
Selection
Switch
DC Power
Input Jack
Electrical
Ground
Chassis
Ground
Hi-Lo Volume
Level Switch
Voltage
Selection
Switch DC Power
,QSXW-DFN
Electrical
Ground Chasis
Ground
Hi-Lo Volume
Level Switch
Figure 9. Rear of SCS Static Monitor 790.

TB-9015 Page 4 of 7 © 2015 DESCO INDUSTRIES, INC.
Employee Owned
SCS -5,QGXVWULDO'ULYH6DQIRUG1&:HEVLWHStaticControl.com
Operating Your System
5HIHUWR)LJXUHVDQG
Power Up
$SSO\SRZHUWRWKH6&66WDWLF0RQLWRUE\LQVHUWLQJ
the round connector on the end of the AC adaptor, into
WKHMDFNDWWKHUHDURIWKH6WDWLF0RQLWRU3OXJWKH
AC adaptor into an appropriate electrical outlet. The
green lamp should illuminate, signaling that the unit is
operational and that there are no alarm conditions. If
WKHJUHHQODPSGRHVQRWLOOXPLQDWHEXWUHGODPSVDUH
LOOXPLQDWHGZLWKDXGLEOHDODUPVRXQGLQJFKHFNDOOFRUGV
and ground connections.
Audible Alarm Volume Level
6HOHFWWKHGHVLUHGDXGLEOHDODUPYROXPHOHYHODWWKHUHDU
RIWKH6WDWLF0RQLWRUE\VOLGLQJWKHVZLWFKWRWKH+L
or Lo position.
Selection of the Reference Voltage
The Static Monitor 790 allows for the selection of one of
IRXULQWHUQDOUHIHUHQFHYROWDJHV999DQG9ZLWK
9EHLQJWKHPRVWVHQVLWLYHVHWWLQJDQG9WKHOHDVW
VHQVLWLYH6HOHFWDYROWDJHOHYHOE\VOLGLQJWKHVZLWFK
WRWKHDSSURSULDWHSRVLWLRQ7KHVHUDQJHVKDYHEHHQ
GHVLJQHGWRDFFRPPRGDWHJOREDO(6'UHTXLUHPHQWV
7KHVHOHFWLRQRIWKLVRSHUDWLRQDOSDUDPHWHULVEDVHG
upon the user s ESD control program requirements.
Fault Conditions – Lamps & Audible Alarms
For wrist strap malfunctions, the Static Monitor 790
indicates different alarms for each operator; a slow
DXGLEOHEHHSIODVKLQJODPSIRUWKHRSHUDWRURQWKHOHIW
LQSXWVLGHDQGDIDVWDXGLEOHFKLUSLQJEHHSIODVKLQJODPS
for the operator on the right input side. For grounding/
chassis-monitoring malfunctions, a continuous tone is
HPLWWHGZLWKERWKODPSVLOOXPLQDWHG
D5HGODPSVIODVKLQJZLWKDQDXGLEOHDODUP
7KLVDODUPPRGHFDQEHFDXVHGE\WZRFRQGLWLRQV
DQGERWKDUHLQWHUUHODWHG,IHLWKHUWKHYROWDJHOHYHO
on the operator is greater than the pre-selected
LQWHUQDOUHIHUHQFHYROWDJHRUSRRUFRQWDFWEHWZHHQ
WKHZULVWEDQGDQGWKHDUPH[LVWWKHDODUPZLOO
activate.
If the SCS Static Monitor 790 alarm activates when
WKHRSHUDWRULVQRWPRYLQJQRUPDOO\DQRQFKDUJLQJ
VLWXDWLRQWKHFDXVHLVPRVWOLNHO\GXHWRSRRU
FRQWDFWEHWZHHQWKHZULVWEDQGDQGWKHDUP7KH
DODUPLQJSHULRGZRXOGQRUPDOO\EHORQJLQGXUDWLRQ
XQOHVVLQWHUPLWWHQWFRQWDFWGXULQJWKLVW\SHRI
FRQGLWLRQ&KHFNFRQWDFWEHWZHHQWKHZULVWEDQGDQG
arm. Some operators may have difficulty in providing
VXIILFLHQWFRQWDFWWRWKHZULVWEDQGEHFDXVHRIGU\
VNLQRUDUPKDLU7KH\PD\QHHGWRXVHDQDSSURYHG
VNLQPRLVWXUL]HURUUHSRVLWLRQWKHZULVWEDQGRQWKH
arm.
If the monitor’s alarm does not activate while the
operator is not moving, then the cause of the alarm
ZDVPRVWOLNHO\GXHWRDYROWDJHEHLQJGHYHORSHGRQ
WKHRSHUDWRU$KLJKUHVLVWDQFHEHWZHHQWKHRSHUDWRU
and ground would allow the operator to charge up as
WKH\PRYHGDERXW7KHDODUPSHULRGIRUWKLVW\SHRI
IDXOWZRXOGQRUPDOO\EHVKRUWDQGFRLQFLGHZLWKWKHLU
ERG\PRYHPHQW
$ODUPLQJFDQDOVREHFDXVHGE\DQLQWHUPLWWHQW
or high resistance in the wrist strap’s dual conductor
JURXQGFRUG5HSODFHDVXVSHFWFRUGZLWKDNQRZQ
JRRGJURXQGFRUGRUFKHFNWKHHQGWRHQGUHVLVWDQFH
RIWKHFRUGXVLQJDQRKPPHWHU$SSUR[LPDWHO\
PHJRKPRIUHVLVWDQFHVKRXOGH[LVWEHWZHHQWKHWLSWR
WLSDQGEDUUHOWREDUUHOFRQWDFWVRIWKHWZRSOXJV
located on opposite ends of the cord.
1RWH7KHRSHUDWRUVPD\FRPSODLQWKDWWKHDODUP
LVVRXQGLQJWRRRIWHQXQWLOWKH\OHDUQWRDGMXVWWKH
ZULVWEDQGWRILWVHFXUHO\RUDSSO\DQDSSURYHGVNLQ
PRLVWXUL]HURQDIUHTXHQWEDVLV3OHDVHUHPHPEHU
that the monitor is informing you that the operator is
H[FHHGLQJWKHHVWDEOLVKHGVWDWLFFRQWUROUHTXLUHPHQWIRU
voltage to ground when wearing a static protective wrist
VWUDSDVVHPEO\7KHVHDODUPVDOHUWWKHRSHUDWRUZKHQ
VHQVLWLYHHOHFWURQLFVDUHSRVVLEO\EHLQJH[SRVHGWR
static electricity. Prior to incorporating the static monitor
into your static control process, the operator was
unaware of these events.
E7ZRUHGODPSVLOOXPLQDWHGFRQWLQXRXVO\ZLWKDQ
DXGLEOHDODUP7KLVLQGLFDWHVWKDWDKLJKUHVLVWDQFH
FRQGLWLRQJUHDWHUWKDQRKPVH[LVWVEHWZHHQWKH
Chassis/Ground Cord and ground. This will include
WKHHTXLSPHQWFKDVVLVJURXQGLIEHLQJPRQLWRUHG
&KHFNWKHJURXQGFRUGVIRUFRQWLQXLW\DQGJURXQG
attachment points.
Connecting an Operator to the SCS
Static Monitor 790
$WWDFKD6&6'XDO&RQGXFWRU:ULVWEDQGWRWKH
DUPDQGDGMXVWWKHEDQGIRUDVQXJILWIROORZLQJWKH
LQVWUXFWLRQVUHFHLYHGZLWKWKHZULVWEDQG
,QVHUWD'XDO&RQGXFWRU*URXQG&RUGORQJHUSOXJ
HQGLQWRHLWKHURQHRIWKHLQSXWMDFNVORFDWHGRQ
the front of the Static Monitor 790. The wrist strap
monitoring function is activated during this step.
7KHJUHHQODPSH[WLQJXLVKHVDWWKLVWLPHDQGWKH
FRUUHVSRQGLQJUHGODPSZLOOLOOXPLQDWHZLWKDQDXGLEOH
alarm.
,QVHUWWKHRWKHUHQGRIWKHJURXQGFRUGVKRUWHUSOXJ
HQGLQWRWKHZULVWEDQGVRFNHW7KHUHGODPSDQGWKH
DXGLEOHDODUPVKRXOGEHH[WLQJXLVKHGDWWKLVWLPH
1RWH)ROORZLQJWKHDWWDFKPHQWVHTXHQFHDERYH
SURYLGHVDQRSHUDWRUVZLWKDVLPSOHJRQRJRWHVWRI
the wrist strap function every time they connect to the
Static Monitor 790.

TB-9015 Page 5 of 7 © 2015 DESCO INDUSTRIES, INC.
Employee Owned
SCS -5,QGXVWULDO'ULYH6DQIRUG1&:HEVLWHStaticControl.com
Quick Review of Functions
,IWKHPRQLWRU¶VJURXQGFRQQHFWLRQLVPDLQWDLQHG
LQFOXGLQJWKHFKDVVLVJURXQGFRQQHFWLRQZKHQ
PRQLWRUHGDQGWKHRSHUDWRU¶VYROWDJHLVKHOGEHORZ
WKHSUHVHOHFWHGUDQJHWKHFRUGZULVWEDQGDQG
contact to the arm of the wearer are all considered to
EHIXQFWLRQLQJFRUUHFWO\$WWKLVWLPHWKHJUHHQODPS
illuminates on the front of the monitor.
,IDQRSHUDWRUVGHYHORSVDYROWDJHWKDWH[FHHGV
WKHSUHVHOHFWHGYROWDJHGXULQJQRUPDOZRUNDFWLYLWLHV
or the monitor loses its ground connection, the green
ODPSH[WLQJXLVKHVDQGUHGODPSVZLOOLOOXPLQDWHZLWK
DFRUUHVSRQGLQJDXGLEOHDODUP7KLVLVDQLQGLFDWLRQ
RIDQH[FHHGHGYROWDJHFRQGLWLRQRQWKHRSHUDWRUGXH
WRSRRUHOHFWULFDOFRQWDFWEHWZHHQWKHDUPDQGEDQGRU
LQWHUPLWWHQWRUEURNHQJURXQGFRUG
$QRSHUDWRU¶VIDXOWFRQGLWLRQLVHDVLO\LGHQWLILHGE\
RQHRIWKHWZRUHGODPSVQH[WWRHDFKLQSXWMDFN
7KHIODVKLQJUHGODPSVLGHQWLILHVWKHRSHUDWRUWKDW
LVH[SHULHQFLQJWKHIDXOWFRQGLWLRQ7KHUHGODPSVDQG
DXGLEOHDODUPVIODVKDQGEHHSDWGLIIHUHQWUDWHVWRKHOS
identify the location of the fault.
SCS Standby Jack 3057
8VHRIDQRSWLRQDO6WDQGE\-DFNDWWKH
ZRUNVWDWLRQH[WHQGVWKHOLIHRIWKHPRQLWRUVLQSXW
MDFNV7KHRSHUDWRUGLVFRQQHFWVWKHJURXQGFRUGIURP
WKHZULVWEDQGDQGSOXJVLQWRWKH6WDQGE\-DFN
WKDWLVPRXQWHGDWWKHZRUNVWDWLRQ3OXJJLQJLQWRWKH
6WDQGE\-DFNSUHYHQWVWKH6WDWLF0RQLWRU
from continuously alarming when disconnected from the
ZULVWEDQG
Verification Procedure
This procedure verifies the positive/negative voltage
detection levels and ground monitoring performance of
the SCS Static Monitor 790 as stated in, Specifications
section of this user guide.
(TXLSPHQW5HTXLUHG±6XSSOLHGE\8VHU
'&3RZHU6XSSO\'&36ZLWKFRQQHFWLQJZLUHV
Output 0 to +10VDC minimum.
'&9ROWPHWHU'&9ZLWKGLJLWDOGLVSOD\DFFXUDF\
and test leads. Use of a voltmeter is only required if
DCPS does not include a digital display.
5HVLVWDQFH6XEVWLWXWLRQ%R[56%RKPVWR
RKPVPLQLPXPRUGLVFUHWHUHVLVWRUVDQG
ohms ±1% value.
6&69HULILFDWLRQ.LW9.2UGHUHG6HSDUDWHO\
6&6'XDO&RQGXFWRU*URXQG&RUG
7ZRZLUHPDOHFRQQHFWRUZLWKWLQQHGOHDGZLUHV
7HVWZULVWEDQGVRFNHW
Procedure:
*URXQG'LVFRQQHFW+L/R$XGLEOH$ODUP9ROXPH
/HYHO)XQFWLRQV*URXQG'LVFRQQHFW6SHFLILFDWLRQ
10 ohms ±20%
D&RQQHFWWKH56%WRWKHWZRZLUHPDOH
FRQQHFWRUZLWKWLQQHGOHDGZLUHV,QVHUW
the two-wire male connector into the mating
MDFNORFDWHGDWWKHUHDURIWKHPRQLWRU
E&RQQHFWWKH$&DGDSWRUVXSSOLHGZLWKWKH
Static Monitor 790 to the 25VDC input
SRZHUMDFNORFDWHGDWWKHUHDURIWKHPRQLWRU
and plug the AC adaptor into a wall outlet.
F6HWWKH56%DVIROORZVDQGREVHUYHDOOODPSV
DQGDXGLEOHDODUP
RKPV±*UHHQODPS215HGODPSV2))
DQGDXGLEOHDODUP2))
RKPV±*UHHQODPS2))5HGODPSVERWK
21&RQWLQXRXVLOOXPLQDWLRQDQGDXGLEOH
DODUP21&RQWLQXRXVWRQH
1RWH&RQILUP+LDQG/RDXGLEOHDODUPYROXPHOHYHOV
GXULQJRKPVWHVWFRQGLWLRQE\DGMXVWLQJ+L/RVOLGH
switch located at the rear of the monitor while alarm is
sounding.
:ULVW6WUDS)XQFWLRQ±2SHQ&LUFXLW7HVW
D$GMXVWWKH56%FRQQHFWHGWRWKHWZRZLUH
PDOHFRQQHFWRUWRRKPVRUOHVVWRVLOHQFH
the Ground Disconnect alarm. The green
ODPSVKRXOGEH21DWWKLVWLPH
E&RQQHFWWKH6&6'XDO&RQGXFWRU&RUG
ORQJHUSOXJHQGLQWRRQHRIWKHZULVWVWUDS
inputs on the SCS Static Monitor 790.
/HDYHWKHRWKHUHQGRIWKHFRUGVKRUWHUSOXJ
HQGRSHQFLUFXLWHGDWWKLVWLPH9HULI\WKDW
the green lamp is now OFF, red lamp nearest
WKHZULVWVWUDSLQSXWEHLQJWHVWHGLVIODVKLQJ
DQGWKDWWKHDXGLEOHDODUPLVVRXQGLQJ
1RWH7KHUHGODPSRQWKHOHIWVLGHRIWKHPRQLWRU
flashes at a slower rate than the lamp located on the
ULJKW$OVRWKHDXGLEOHDODUPZLOOVRXQGDWWKHVDPH
UDWHDVWKHLQGLFDWLQJIODVKLQJUHGODPSV7KLVIXQFWLRQ
allows for identifying the fault location.
F5HSHDWWKLVVWHSIRUWKHRWKHUZULVWVWUDS
LQSXWYHULI\LQJSHUIRUPDQFHDVVWDWHGDERYH
Voltage Level Test
9/HYHO6SHFLILFDWLRQ999DQG9
G8QSOXJWKH$&DGDSWRUIURPWKHZDOORXWOHW
H$GMXVW'&36RXWSXWWR9'&
I&RQQHFWDZLUHEHWZHHQWKHSRVLWLYHRXWSXW
WHUPLQDORIWKH'&36DQGWRRQHRIWKHEDFN
SODWHVRIWKHWHVWZULVWEDQGVRFNHW&RQQHFW
DZLUHEHWZHHQWKHFRPPRQRIWKH'&36WR
WKHRWKHUEDFNSODWHRIWKHWHVWZULVWEDQG
VRFNHW
1RWH%HFDUHIXOQRWWRFDXVHDVKRUWFRQGLWLRQEHWZHHQ
the two connecting wires.

TB-9015 Page 6 of 7 © 2015 DESCO INDUSTRIES, INC.
Employee Owned
SCS -5,QGXVWULDO'ULYH6DQIRUG1&:HEVLWHStaticControl.com
J,QVHUWWKH'XDO&RQGXFWRU&RUGVKRUWHUSOXJ
HQGLQWRWKHWHVWZULVWEDQGVRFNHWDQGWKH
RWKHUHQGRIWKHFRUGORQJHUSOXJHQGLQWR
one of the wrist strap inputs on the front of
the Static Monitor 790.
K3OXJWKH$&DGDSWRULQWRWKHZDOORXWOHW
Voltage Level Tolerances
V-Level Switch +15% -15%
1V 1.15VDC 9'&
3 V 3.45VDC 2.55VDC
6 V 6.9VDC 5.1VDC
9 V 10.35VDC 7.65VDC
L6HOHFWWKH9OHYHOXVLQJDVPDOOWLSWRRORQ
the V-Level switch located at the rear of the
monitor.
M$FWLYDWHWKHRXWSXWRIWKH'&36DQGDGMXVWWR
1.15VDC. Verify that the green lamp has
turned OFF, red lamp nearest the wrist strap
LQSXWEHLQJWHVWHGLVIODVKLQJDQGWKDWWKH
DXGLEOHDODUPLV21
1RWH7KHUHGODPSRQWKHOHIWVLGHRIWKHPRQLWRU
flashes at a slower rate than the lamp located on the
ULJKW$OVRWKHDXGLEOHDODUPZLOOVRXQGDWWKHVDPH
UDWHDVWKHLQGLFDWLQJIODVKLQJUHGODPSV7KLVIXQFWLRQ
allows for identifying the fault location.
N$GMXVWWKH'&36WR9'&9HULI\WKDW
the green lamp is ON, red lamp nearest the
ZULVWVWUDSLQSXWEHLQJWHVWHGLV2))DQG
WKDWWKHDXGLEOHDODUPLV2))
O5HSHDWVWHSV-.KRZHYHUQRZ
DGMXVWLQJWKH6&66WDWLF0RQLWRUIRU
V-Levels of 3, 6, and 9VDC and the DCPS
to the appropriate voltage level tolerances as
VWDWHGLQWKHDERYHWDEOH$ODUPLQGLFDWLRQV
ZLOOIROORZDVVWDWHGLQWKH9OHYHOFKHFN
P5HSHDWVWHSV-/XVLQJWKHRWKHUZULVW
strap input on the SCS Static Monitor 790,
YHULI\LQJSHUIRUPDQFHDVVWDWHGDERYH
Q&KDQJHYROWDJHSRODULW\WRWKHZULVWEDQG
WHVWVRFNHWE\UHYHUVLQJWKHZLUHVSUHYLRXVO\
FRQQHFWHGLQVWHSIDERYHDWWKHWHVWVRFNHW
or at the output terminals of the DCPS and
YHULI\SHUIRUPDQFHUHSHDWLQJVWHSV,0
Specifications
Dimensions
+[:['PP[
PP[PP
:HLJKW R]J
Power Supply
Requirements* ,QSXW9$&1RUWK$PHULFD
2XWVLGH1RUWK$PHULFD$VUHTXLUHG
2XWSXW9'&#P$UDWHGORDG
2XWSXW3OXJ3RODUL]DWLRQ&HQWHU
Negative
2XWSXW3OXJ'LPHQVLRQVPP
2'[PP,'[PP/HQJWK
Accuracy The following parameters are valid
for altitudes up to 2000 m. Pollution
GHJUHH&ODVV(TXLSPHQW
9ROWDJH'HWHFWLRQ/HYHOV9
3V, 6V, and 9V ±10%
*URXQG'LVFRQQHFWRKPV
(QYLURQPHQWDO2SHUDWLQJ&RQGLWLRQV
7HPSHUDWXUH0D[LPXP)&
0LQLPXP)&
+XPLGLW\0D[LPXP5+
5HIHUHQFH+HOPV0DQ,QGXVWULDO&R/WG0RGHO1R
DPX411454G
&$87,213XUFKDVHGSRZHUVXSSO\PXVWKDYHDOOORFDO
required regulatory certifications. Line voltage within
WKHSRZHUVXSSO\VKDOOEHLVRODWHGIURPORZYROWDJH
E\GRXEOHRUUHLQIRUFHGLQVXODWLRQ7KH$&DGDSWRULV
required to operate the Static Monitor 790. If the ground
wire of the AC adaptor is not used, it is recommended
WKDWWKHZLUHEHWDSHGEDFNRQWRWKHPDLQFDEOHRIWKH
AC adaptor using electrical tape.
Parts Included
1 ea. SCS Static Monitor 790
1 ea. User’s Guide
HD0RXQWLQJ3ODWHZLWK5HPRYDEOH)RDP7DSH
1 ea. AC Adaptor
2 ea. Chassis/Ground Cords
1 ea. Two-wire Connector

TB-9015 Page 7 of 7 © 2015 DESCO INDUSTRIES, INC.
Employee Owned
SCS -5,QGXVWULDO'ULYH6DQIRUG1&:HEVLWHStaticControl.com
Required Accessories and Optional
Available Parts
Item
Description Size
90 SCS Dual Conductor
)DEULF:ULVWEDQG
$GMXVWDEOH
2360 SCS Dual Conductor
Coil Cord P
2370 SCS Dual Conductor
Coil Cord P
2371 SCS Dual Conductor
Coil Cord P
3057 6&66WDQG%\-DFN [[
[[FP
790VK 6&69HUL¿FDWLRQ.LW
724P SCS Power Supply
Replacement AC
Adapter
Regulatory Information
China RoHS
Electronic Industry Standard of the
3HRSOH¶V5HSXEOLFRI&KLQD6-
T11363-2006, Requirements for
Concentration Limits for Certain
+D]DUGRXV6XEVWDQFHVLQ(OHFWURQLF
Information Products.
7KLVV\PEROSHU0DUNLQJIRUWKH&RQWURORI3ROOXWLRQ
&DXVHGE\(OHFWURQLF,QIRUPDWLRQ3URGXFWV6-
T11364-2006, means that the product or part does
FRQWDLQDVXEVWDQFHDVGHWDLOHGLQWKHFKDUWEHORZLQ
H[FHVVRIWKHIROORZLQJPD[LPXPFRQFHQWUDWLRQYDOXHV
LQDQ\KRPRJHQHRXVPDWHULDODE\ZHLJKWIRU
OHDGPHUFXU\KH[DYDOHQWFKURPLXPSRO\EURPLQDWHG
ELSKHQ\OVRUSRO\EURPLQDWHGGLSKHQ\OHWKHUVRUE
E\ZHLJKWIRUFDGPLXP8QOHVVRWKHUZLVHVWDWHG
E\6&6LQZULWLQJWKLVLQIRUPDWLRQUHSUHVHQWV6&6¶V
EHVWNQRZOHGJHDQGEHOLHIEDVHGXSRQLQIRUPDWLRQ
SURYLGHGE\WKLUGSDUW\VXSSOLHUVWR6&6
7KLVQXPHULFDOUHIHUHQFHVKRXOGQRWEHFRQVWUXHG
as a representation regarding the product’s life or
DQH[WHQVLRQRIDSURGXFWZDUUDQW\,QWKHHYHQWDQ\
product is proven not to conform with SCS’s Regulatory
,QIRUPDWLRQ6KHHWWKHQ6&6¶VHQWLUHOLDELOLW\DQGEX\HU¶V
H[FOXVLYHUHPHG\ZLOOEHDW6&6¶VRSWLRQHLWKHUL
replacement of product with a conforming product,
RULLUHIXQGRIWKHSXUFKDVHSULFHSDLGE\EX\HUIRU
HDFKQRQFRQIRUPLQJSURGXFWZLWKLQDUHDVRQDEOHWLPH
after written notification of said nonconformance and
return of said product to SCS. SCS shall not under any
FLUFXPVWDQFHVEHOLDEOHIRUGLUHFWLQFLGHQWDOVSHFLDORU
FRQVHTXHQWLDOGDPDJHVLQFOXGLQJEXWQRWOLPLWHGWRORVV
RISURILWVUHYHQXHRUEXVLQHVVUHODWHGWRRUDULVLQJRXW
RIWKLVFHUWLILFDWLRQLQFOXGLQJWKHXVHPLVXVHRULQDELOLW\
to use the product. Unless stated otherwise in writing,
WKHIRUHJRLQJODQJXDJHFDQQRWEHZDLYHGPRGLILHGRU
supplemented in any manner whatsoever.
WEEE Statement
7KHIROORZLQJLQIRUPDWLRQLVRQO\IRU(8PHPEHU6WDWHV
7KHPDUNVKRZQWRWKHULJKWLVLQFRPSOLDQFHZLWK:DVWH
Electrical and Electronic Equipment Directive 2002/96/
(&:(((7KHPDUNLQGLFDWHVWKHUHTXLUHPHQW127
to dispose the equipment as unsorted municipal waste,
EXWXVHWKHUHWXUQDQGFROOHFWLRQV\VWHPVDFFRUGLQJWR
local law.
cULus Statement
Meets UL Safety Requirements.
FCC
1RWH7KLVHTXLSPHQWKDVEHHQWHVWHGDQGIRXQGWR
comply with the limits for a Class A digital device,
pursuant to Part 15 of the FCC Rules. These limits are
GHVLJQHGWRSURYLGHDUHDVRQDEOHSURWHFWLRQDJDLQVW
harmful interference when the equipment is operated in
a commercial environment. This equipment generates,
uses, and can radiate radio frequency energy and, if not
installed and used in accordance with the instruction
manual, may cause harmful interference to radio
communications. Operation of this equipment in a
UHVLGHQWLDODUHDLVOLNHO\WRFDXVHKDUPIXOLQWHUIHUHQFH
LQZKLFKFDVHWKHXVHUZLOOEHUHTXLUHGWRFRUUHFWWKH
LQWHUIHUHQFHDWWKHLURZQH[SHQVH
1RWH0RGLILFDWLRQVWRWKLVGHYLFHVKDOOQRWEHPDGH
ZLWKRXWWKHZULWWHQFRQVHQWRI6&68QDXWKRUL]HG
modifications may void the authority granted under
Federal Communication Rules and Industry Canada
Rules permitting the operation of this device.
This device complies with Part 15 of the FCC Rules.
2SHUDWLRQLVVXEMHFWWRWKHIROORZLQJWZRFRQGLWLRQV
this device may not cause harmful interference, and
WKLVGHYLFHPXVWDFFHSWDQ\LQWHUIHUHQFHUHFHLYHG
including interference that may cause undesired
operation.
ICES Statement
This Class A digital apparatus meets all requirements
of the Canadian Interference-Causing Equipment
Regulations.
Cet appareil numérique de la classe A respecte toutes
OHVH[LJHQFHVGX5qJOHPHQWVXUOHPDWpULHOEURXLOOHXUGX
Canada.
Made in China
Limited Warranty, Warranty Exclusions, Limit of
Liability and RMA Request Instructions
6HHWKH6&6:DUUDQW\
KWWSVWDWLFFRQWUROGHVFRLQGXVWULHVFRPZDUUDQW\DVS[
Table of contents
Other SCS Monitor manuals