Instructions for use 1402
1. Turn the Master On/Off toggle to the ‘On’ position. It is located under the left side
edge of the control head.
2. The handpieces are automatically activated when removed from their hanger.
3. Depress the Foot Control to operate the activated handpiece. Pressure is shown on
the gauge for the handpiece being used.
•NOTE: Individual handpiece pressure adjustments are located at the bottom rear
of the control head.
To adjust the pressure to each handpiece, turn the adjustment screw clockwise to
decrease pressure or counterclockwise to increase pressure.
CAUTION:When adjusting the handpiece pressure, do not over-tighten the screws.
This may result in unnecessary damage to the handpiece control block.
4. To activate water spray, turn the Water On/Off Toggle to the ‘On’ position. It is
located on the right-side edge under the control head. Flow adjustment to the ‘wet’
handpieces is controlled by the controls labeled ‘Flow Control’.