logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Sea gull lighting
  6. •
  7. Landscape Lighting
  8. •
  9. Sea gull lighting HC-564 Manual

Sea gull lighting HC-564 Manual

Other Sea gull lighting Landscape Lighting manuals

Sea gull lighting Unique Lightscaping 91057-147 Cardinal Programming manual

Sea gull lighting

Sea gull lighting Unique Lightscaping 91057-147 Cardinal Programming manual

Popular Landscape Lighting manuals by other brands

Intex SL1006 owner's manual

Intex

Intex SL1006 owner's manual

LED Group ROBUS R2IN13W quick start guide

LED Group

LED Group ROBUS R2IN13W quick start guide

Patriot Lighting 343-1484 installation manual

Patriot Lighting

Patriot Lighting 343-1484 installation manual

LIGMAN JET 44 installation manual

LIGMAN

LIGMAN JET 44 installation manual

Hess SERA G: SERA S Installation and operating instructions

Hess

Hess SERA G: SERA S Installation and operating instructions

LIGMAN MALTA 1 installation manual

LIGMAN

LIGMAN MALTA 1 installation manual

Cooper Lighting Invue 42 - 175W Specification sheet

Cooper Lighting

Cooper Lighting Invue 42 - 175W Specification sheet

Saxby Lighting Islay 68784 Instruction leaflet

Saxby Lighting

Saxby Lighting Islay 68784 Instruction leaflet

LIGMAN EU-10016-3 installation manual

LIGMAN

LIGMAN EU-10016-3 installation manual

Cooper Lighting McGraw-Edison ZD Credenza specification

Cooper Lighting

Cooper Lighting McGraw-Edison ZD Credenza specification

LIGMAN KI-60475 installation manual

LIGMAN

LIGMAN KI-60475 installation manual

Cooper Lighting Generation CLB25MWW5C373 Specification sheet

Cooper Lighting

Cooper Lighting Generation CLB25MWW5C373 Specification sheet

Malibu Boats CL905K instructions

Malibu Boats

Malibu Boats CL905K instructions

LIGMAN NYB-30161 installation manual

LIGMAN

LIGMAN NYB-30161 installation manual

LIGMAN SI-80021 installation manual

LIGMAN

LIGMAN SI-80021 installation manual

Volt 2-in-1 Tiki-Brass Torch Light installation instructions

Volt

Volt 2-in-1 Tiki-Brass Torch Light installation instructions

Malibu Boats CM110P instructions

Malibu Boats

Malibu Boats CM110P instructions

LIGMAN VIENNA 1 installation manual

LIGMAN

LIGMAN VIENNA 1 installation manual

https://manuals.online logo
https://manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

FOR YOUR SAFETY
WARNING: BE SURE THE ELECTRICITY TO THE WIRES
YOU ARE WORKING ON IS TURNED OFF; EITHER
THE FUSE REMOVED OR THE CIRCUIT BREAKER SET
AT OFF.
9219-12 Well Light
NOTE: INSTALL PIPE FLUSH WITH GROUND FOR
VERTICAL TO HORIZONTAL ILLUMINATION. FOR ACUTE
ANGLES THREAD 9344 STAKE (NOT INCLUDED) AT THE
BOTTOM OF WELL LIGHTS.
ASSEMBLY
1. Snap MR16 lamp into lamp bracket.
2. Push socket onto lamp pins.
3. Install lamp and bracket into the well light housing until
bracket lip come in contact with housing lip.
4. Do not allow cable to touch the MR16 lamp. The heat
from the lamp may cause the cable insulation to melt,
resulting in a short.
5. OPTIONAL: Squeeze accessory ring ends and remove
from shroud. Insert optional accessory (not included).
Secure with accessory ring.
6. Secure shroud to well light housing with set screw.
INSTALLATION AND SAFETY INSTRUCTIONS HC-564
SHROUD
SET SCREW
*MR16 LAMP
LAMP BRACKET
BRACKET LIP
REFLECTOR
SOCKET
WELL LIGHT
HOUSING
*NOT INCLUDED
ACCESSORY RING
* ACCESSORY
LOW VOLTAGE
FIXTURE CABLE
Installation And Safety
Instruction
HC-564
050605
Line art shown may not exactly match the fixture enclosed.
However, the installation instructions do apply to this fixture.
Fill In Item Number On Carton And
File This Sheet For Fixture Reference. ITEM#_______________
®
Fig. 1
O-RING
FINAL INSTALLATION
1. Insert well light lamp housing assembly into hole allowing
enough loose socket leads for relamping. Run cable
along surface of ground. Tamp ground to secure in place.
2. Attach fixture cable to main supply cable with connector
(#9477) (supplied) or use silicone filled wire nuts (#9386)
(not included).
*CONNECTOR
FIXTURE
CABLE
WELL LIGHT
HOUSING
*GRAVEL
6”
*NOT INCLUDED
INSTRUCTIONS PERTAINING TO A RISK OF FIRE, OR
INJURY TO PERSONS.
IMPORTANT SAFETY INSTRUCTIONS!
Lighted lamp is HOT!
WARNING: TO REDUCE THE RISK OF FIRE OR INJURY
TO PERSONS:
1. Turn off/unplug and allow to cool before replacing lamp.
2. Lamp gets HOT quickly! Contact only switch/plug when
turning on.
3. Do not touch hot lens, guard, or housing.
4. Keep lamp away from materials that may burn.
5. Do not touch the lamp at any time. Use a soft cloth.
Oil from skin may damage lamp.
6. Do not operate the fixture with a missing or damaged shield.
SAVE THESE INSTRUCTIONS!
INSTALLATION AND SAFETY INSTRUCTIONS
FOR YOUR SAFETY HC-564
WARNING: Be sure the electricity to the wires you are working
on is shut off; either the fuse removed or the circuit breaker off.
RISK OF FIRE: Exceeding maximum wattage may result in
over-heating conductors. Read instructions carefully. If you are
unclear as to how to proceed, consult a qualified electrician.
NOTE:
The supplied connector works with maximum 12/2 Ambiance
landscape cable. To connect this well light to 10/2 Ambiance
cable, silicone wire nuts (#9386) should be used.
FIXTURE
WIRE
NOTCH
CONTACT
MAX. 50W AT 12V (OUTDOOR)
1. Cut the fixture wire to desired length.
2. Split ends of wire about (1/2") and insert each end of the wire
as far as possible into the plug. Do not strip any insulation off
the wire.
3. Insert contact into one end of plug and press or use pliers until
contact is flush with plug. Repeat with other contact (see Fig. 3)
4. Twist wires sideways, insert into notch in plug and twist back
straight.
5. Snap landscape clip under the low voltage supply cable.
6. Snap plug on to clip and cable.
INSTALLATION OF (9477) CONNECTOR
FIG. 3
SET SCREW
WIRE CLIP
#9477
CONNECTOR
*LOW VOLTAGE
LANDSCAPE CABLE
FIG. 4
WARNING: TO AVOID EXCESSIVE HEAT AND THE
POSSIBILITY OF DAMAGE TO THE FIXTURE AND
SURROUNDING AREA, MAKE SURE THE HOUSING AND
GLASS LENS ARE NOT BURIED AND FREE FROM
DEBRIS.
FIG. 2
*NOT INCLUDED
FIXTURE
CABLE
#9477
CONNECTOR
FIXTURE CABLE
INSTALLATION
1. Dig hole the diameter of plastic pipe and about six inches
deeper - fill bottom of hole with gravel for drainage.