1. SAFETY
8DO NOT use for any purpose other than that which the extinguisher is intended for.
9 Extinguishersshouldremainintheirallocatedlocation,andshouldbeusedonlyforthepurposesofextinguishingare.
9On no account should the extinguisher be removed for any other purpose, and should not be subjected to any impact, force, heat,
abrasion or any other misuse or condition that may be detrimental to the integrity of the extinguisher.
9 Conrmthatthepressuregaugeindicator(whereapplicable)isinthegreenzoneatroomtemperature.
9 Conrmthattheanti-tampersealholdingthesafetypininplaceisintact.
9 Conrmthatthedischargehose,hornornozzlesarermlyattachedtotheextinguisher.
9 Checkthattheextinguisherhassuerednophysicaldamageintransit.
9It is essential that extinguishers are not subjected to temperatures outside of the temperature range stated on the extinguisher.
2. i INTRODUCTION
SFE06AFFF(aqueousfilm-formingfoam)extinguishersuitableforuseonA,BClassfires.Leak-testedandfeaturespolypropylene
lined cylinder with brass valve assembly. Five year warranty. Refillable, supplied with wall mounting bracket and pressure gauge. Fully
accreditedtoBSEN3andKitemarked.
3. i SPECIFICATION
Model No: ................................................................... SFE06
Capacity:........................................................................... 6ltr
Class/Type: ............................................................. AB/Foam
Fire Test Rating:..................................................... 13A/144B
Working Pressure:.........................................................12bar
Height/Diameter: ................................................. 540/220mm
Weight:........................................................................ 10.1kg
Discharge Duration: ..................................................... 38sec
Discharge Range: ........................................................3-4mtr
Working Temperature:......................................... +5 to +60°C
4. INSTALLATION
4.1. Fire extinguishers should be commissioned and installed by a Competent Fire Engineer who will check the product prior to installation
and apply a service label. Some Insurance Policies may be invalidated if the service label does not carry a Fire Engineers signature.
4.1.1. ThenamesofFireEngineeringcompaniescanbefoundon-lineorinYellowPagesorsimilarundersuchheadingsasFireProtection
EngineersandFireExtinguishing.TheseCompanieswillnotonlyinstallyourextinguisher(s)butprovidelongertermservicingcover.
4.1.2. WewouldrecommendthataCompanyapprovedbyFETA,BAFE,BSIortheBritishFireConsortiumbeselected.
4.1.3. ForfurtheradviceonthelocationofyourextinguisherpleasecontactyourlocalFireEngineerorFireBrigade.
4.1.4. Theextinguishermountingbracketshouldbexedtothewallsothattheextinguisherhandleisapproximately1metreabovetheoor.
4.1.5. Extinguishersshouldremainintheirallocatedlocation,andshouldbeusedonlyforthepurposesofextinguishingare.
4.1.6. On no account should the extinguisher be removed for any other purpose, and should not be subjected to any impact, force,
heat, abrasion or any other misuse or condition that may be detrimental to the integrity of the extinguisher. It is essential that
extinguishers are not subjected to temperatures outside of the temperature range stated on the extinguisher.
4.1.7. Fireextinguishersarelifesavingappliancesandassuch,needtooperatecorrectlyintheeventofare.
DO NOT use as a toy.
SFE06Issue2(H,4,5,F)12/11/18
Original Language Version
© Jack Sealey Limited
Refer to
instruction
manual

5. MAINTENANCE
5.1. Theextinguishersshouldbevisuallyinspectedatleastquarterly,butpreferablymonthly,bytheuser,toensurethattheequipmentisin
itsdesignatedposition,hasnotbeenusedandhasnotbeentamperedwith.Theservicingofreghtingequipmentmustbecarried
outbyacompetentpersonusingthecorrecttoolstofollowtheproceduresofBS5306part3,2003andthemanufacturersinstructions.
This maintenance should be performed at least annually.
5.1.1. Inspect regularly for damage and operational serviceablility.
5.1.2. Ifpressureindicatorisintheredzonerechargetheextinguisher.
DO NOT test prior to use.
5.1.3. CheckservicabilityatleastannuallyinaccordancewithBS5306PART3:2003.
5.1.4. Recharge after complete or partial use.
5.1.5. RellingandservicingshouldbecarriedoutbyacompetentpersoninaccordancewithBS5306-9:2015
5.1.6. Use only product and spare parts approved by the manufacturer for this model.
5.1.7. Rellcharge:6litres(100%).Water:5.82litres(97%),AFFF:0.18litres(3%).Pressurisedwithnitrogentoaworkingpressureof12
bar at 200C.
5.1.8. Storage/operating temperature range : +50C to + 600C. Protect from frost.
5.1.9. Testpressure(PT):27bar.
Original Language Version
© Jack Sealey Limited
Sealey Group, Kempson Way, Suffolk Business Park, Bury St Edmunds, Suffolk. IP32 7AR
01284 757500 01284 703534 sales@sealey.co.uk www.sealey.co.uk
ENVIRONMENT PROTECTION
Recycle unwanted materials instead of disposing of them as waste. All tools, accessories and packaging should be sorted, taken to
a recycling centre and disposed of in a manner which is compatible with the environment. When the product becomes completely
unserviceableandrequiresdisposal,drainanyfluids(ifapplicable)intoapprovedcontainersanddisposeoftheproductandfluids
according to local regulations.
Note: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior
notice.
Important: No Liability is accepted for incorrect use of this product.
Warranty:Guaranteeis12monthsfrompurchasedate,proofofwhichisrequiredforanyclaim.
SFE06Issue2(H,4,5,F)12/11/18
Table of contents
Popular Fire Extinguisher manuals by other brands

First Alert
First Alert FE5GO-MN Product specifications

First Alert
First Alert FESA5 user manual

First Alert
First Alert FE1A10GO Product specifications

Glasdon
Glasdon FIREXPIRE Assembly and maintenance instructions

First Alert
First Alert M08-0036-001 user manual

Sea-Fire
Sea-Fire FM200 FG Installation instructions & owner's manual