PLATFORM SCAFFOLD STAND
MODEL NO: SSCL1.V2
TOWER EXTENSION PACK 3 MODEL NO: SSCL3
TOWER EXTENSION PACK 4 MODEL NO: SSCL4
Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these instructions,
and properly maintained, give you years of trouble free performance.
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE
THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR
PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.
1. SAFETY
WARNING! Take care when using and moving scaffolding, extended ladders and other such equipment in the vicinity of power
cables - risk of potentially fatal electric shock.
WARNING! Ensure Health and Safety, local authority, and general workshop practice regulations are adhered to when using this
equipment.
9Familiarise yourself with the application and limitations of the scaffold, as well as the potential hazards.
9Maintain the equipment in good condition.
8DO NOT use the equipment if any parts are damaged or missing as this may cause failure and/or personal injury.
9Replace or repair damaged parts. Use genuine parts only.
9Non-authorised parts may be dangerous and will invalidate the warranty.
9Keep the work area clean, uncluttered and ensure there is adequate lighting.
WARNING! Use scaffold on level and solid ground and ensure the brakes are applied and/or that the scaffold is anchored and held firmly
in place by some means.
WARNING! DO NOT erect or use the scaffolding on sloping or unstable ground.
WARNING! Never over-reach when on the scaffolding.
9Keep children and unauthorised persons away from the working area.
8DO NOT use the scaffolding for any purpose other than that for which it is designed.
8DO NOT allow children to climb the scaffolding.
8DO NOT use the equipment when you are tired, under the influence of alcohol, drugs or intoxicating medication.
9When not in use store in a safe, dry, childproof area.
8DO NOT use the equipment without side guardrails, knee rails and toe boards fitted. Use all the components supplied.
9When used outside, mobile scaffold towers should, wherever possible, be secured to a building or other reliable structure.
9It is good practice to tie in all scaffold towers of any height, especially when left unattended or in exposed windy conditions.
Use only the recommended wall anchors.
9Beware of strong wind conditions. DO NOT erect or use a free standing tower if the wind is likely to exceed 7.7m/sec (17mph or Beaufort
force 4).
9Take care when using mobile scaffold towers in hangers or uncovered buildings as wind force may be increased due to funnelling effects.
8DO NOT climb a tower from the outside. Never climb on the horizontal or diagonal braces. You should only climb the tower on the
inside using the ladder end frames.
8DO NOT lean ladders against the tower. Never use ladders or boxes to gain additional height.
8DO NOT bridge between the mobile scaffold tower and buildings.
9Stabilisers and ballast weights shall always be tted where specied. Ballast is used at the base to stabilise towers from
overturning. Ballast must be of solid material (i.e. NOT water or loose sand) and should be positioned so as not to overload
individual legs. Ballast should be secured from accidental removal.
9Keep equipment clean and inspect before and after use for damage. Use serviceable equipment only. All working parts e.g.
castors, adjustable legs; stabiliser clamps should be lubricated lightly with oil. Repairs should only be carried out by the supplier or
other competent person approved by the supplier.
9Ensure that all personnel, tools and materials are removed from the tower prior to moving it. Only move the scaffold tower
manually on a rm level surface, which is free of any obstacles.
9Only move it longitudinally or diagonally. DO NOT exceed normal walking speed. Raise the stabilisers 12mm (½”) from the ground.
9 After moving re-lock the castors, check that the tower is level and ensure that the stabilisers are secure and have a rm footing.
8DO NOT exceed the safe working load of the platform. The maximum capacity of the working platform for an evenly distributed load is
1.5 kN/m² (according to HD1004 – scaffold tower Class 2).
8DO NOT jump on to or off the platforms.
8DO NOT use any lifting equipment on the mobile scaffold tower.
2. INTRODUCTION
SSCL1.V2: EN1004 Approved Scaffold Tower System designed to meet the UK PASMA 3T standards. Robust aluminium frame unit with
durable corrosion resistance. Heavy-duty platform with trap door for safe access to platform. SSCL1 can be used as a 3mtr or 3.8mtr
working height platform by fitting extension kit supplied with the unit. Unique design enables the unit to be quickly and easily folded down without
tools for transportation or storage. 860mm depth means unit will pass through most doorways even when fully erected. Hand rails for comfort and
safety. Four large Ø125mm castors for easy mobility.
Refer to
instruction
manual
Original Language Version
© Jack Sealey Limited SSCL1.V2, SSCL3, SSCL4 | Issue:3 (3) 12/11/19