4
Programming
The Keypad is programmed via the buttons using a 4 Digit Master code and each User code
has a slot number 001-050 for each 2-8 Digit code to be stored. The Door open time for the
relay can be set for 1-99 seconds or can be set to Toggle On and Off.
To Add a Single User code (2-8 Digits):-
1. Enter: # 1 2 3 4 # - Double beep and Red Led flashes.
2. Enter: 3 digit Slot number 001 to 050 - Double beep.
3. Enter: New Code # Repeat Code - Double beep.
4. Enter: # to exit Programming - Double beep and Red Led goes out.
Note: Individual codes can't be deleted but can be re-programmed into the Slot number.
To unlock the Door:-
Enter: User code # - If correct - Long beep and Yellow Led (If incorrect code - Long beep Red Led)
To Change Door Open time:-
1. Enter: # 1 2 3 4 # - Double beep and Red Led flashes on/off.
2. Enter: 251 to change time - Double beep.
3. Enter: Number of Seconds # Repeat Number of Seconds - Double beep.
(Number of seconds must be 01 to 99 or 00 for Toggle option*)
*Note: Toggle option can only be used with 12v DC systems.
4. Enter: # to exit Programming - Double beep and Red Led goes out.
To Delete ALL user codes:-
1. Enter: # 1 2 3 4 # - Double beep and Red Led flashes on/off.
2. Enter: 253 to delete all users - Double beep.
3. Enter 8 8 8 8 # 8 8 8 8 - Wait for long beep.
4. Enter: # to exit Programming - Double beep and Red Led goes out.
To Change the 4 digit Master code:-
1. Enter: # 1 2 3 4 # - Double beep and Red Led flashes on/off.
2. Enter: 000 to change Master code - Double beep.
3. Enter: New 4 digit Code # Repeat 4 digit Code - Double beep.
4. Enter: # to exit Programming - Double beep and Red Led goes out.
To Reset keypad to Factory defaults:
1. Switch off power to the keypad (check blue Led has gone out).
2. On the back of the keypad (top left corner of PCB) move the black peg from Normal position to
Restore position.
3. Switch on the power and move peg back to Normal position. Unit is new reset to Factory default.
Contents:
Page 2: Installation instructions and Wiring for Fail Locked Electric strike
Page 3. Wiring detail for Fail Un-Locked Electric Strike and Magnetic Lock
Page 4. Programming Instructions and Restore Factory defaults procedure
Specification:
Operating Voltage: 12v AC or DC +/- 10%
Maximum Operating current: 80mA
Maximum Relay Output: 2amps @ 12v DC
Number of users: 1 to 50
Dimensions: 116 x 74 x 22mm
Contact Securefast for assistance
Tel: +44(0)1704 502815
email: [email protected]
fax: +44 (0)1704 502810
or visit www.securefast.co.uk
23
NUL NUL GND DECT NO COM NC REMO DC / AC
Keypad Connection terminals
Com N/O
Exit Button
Electric Release
12v AC or DC
Fail Locked
0v / -
12v / +
Transformer
or
Power Supply
F
U
S
E
Note: Do not switch power on
until all connections are made
The APX-15 Keypad is a robust vandal resistant keypad which is suitable for Internal/External installations for
controlling an Electric Lock or Magnetic Lock. It can also be used to trigger an Automatic Door or Barrier.
The keypad can be connected to a 12v AC Transformer or 12v DC Regulated Power supply with a minimum
load rating of 1 amp. The maximum current draw of the Lock or Magnet is 2 amps. A Single User code or up to
50 codes can be added (2-8 digits long). The Relay of the keypad can be set for 1-99 seconds delay or can
be set to Toggle On/Off. Programming is done via the buttons using a 4 digit Master code. NUL NUL GND DECT NO COM NC REMO DC / AC
Keypad Connection terminals
Com N/O
Exit Button
-
+
Regulated
Power Supply
12v DC 1A
F
U
S
E
Installation
Step 1. Using the keypad backplate as a template fix to a flat/level surface.
(the keypad should be fitted at 1 to 1.5 metres from the floor).
Step 2. Run 2 core 0.5mm2 cables through the wall for the Electric lock,
Power unit and Exit Button (if required). Seal cable entry hole.
Step 3. Fit Transformer or Power supply as per Manufacturer instructions.
Fit Electric lock/Magnetic lock as per Manufacturer instructions.
If required fit Exit Button as per Manufacturer Instructions.
Step 4. Connect the Electric lock and Exit Button (if required), then connect
the Transformer/Power supply as per the wiring detail below.
Fix the Keypad to the backplate with the Torx screw at the bottom.
Step 5. Apply power to the Transformer/Power supply and check that the
Blue LED is lit on the keypad. If an Exit button is fitted press it and
check if the Yellow LED lights and the Electric Lock/Magnetic lock is
released.
Wiring detail for 12v AC or DC Electric Strike Fail Locked
Wiring detail for 12v DC Electric Strike Fail Un-Locked
Electric Release
12v DC
Fail Un-Locked
Note: Do not switch power on
until all connections are made
NUL NUL GND DECT NO COM NC REMO DC / AC
Keypad Connection terminals
Com N/O
Exit Button
F
U
S
E
Wiring detail for 12v DC Electro-Magnetic lock c/w Emergency Call Point
Magnetic Lock 12v DC
Note: Do not switch power on
until all connections are made
Regulated
Power Supply
12v DC 1A
-
+
-
+
Com
N/C
Emergency
Call Point
Please contact Technical for all other wiring configurations

Popular Keypad manuals by other brands

Texecom Premier Elite LCDLP-W manual

Texecom

Texecom Premier Elite LCDLP-W manual

DSC PC1000 instruction manual

DSC

DSC PC1000 instruction manual

RS Advantage 6 quick start guide

RS

RS Advantage 6 quick start guide

rako WCM-060 instruction manual

rako

rako WCM-060 instruction manual

Philio PSK01 user manual

Philio

Philio PSK01 user manual

Crestron C2N-DB12 Operations & installation guide

Crestron

Crestron C2N-DB12 Operations & installation guide

Comelit UT9279M Technical manual

Comelit

Comelit UT9279M Technical manual

perixx PERIPAD-202 user manual

perixx

perixx PERIPAD-202 user manual

ASTRO-PHYSICS GTO KEYPAD Addendum

ASTRO-PHYSICS

ASTRO-PHYSICS GTO KEYPAD Addendum

Velleman CTC1000KP user manual

Velleman

Velleman CTC1000KP user manual

Intelligent Security 868SLH quick start guide

Intelligent Security

Intelligent Security 868SLH quick start guide

SCS Sentinel CodeAccess RFID Installation and user manual

SCS Sentinel

SCS Sentinel CodeAccess RFID Installation and user manual

Partizan PAS-EMHK12 Service manual

Partizan

Partizan PAS-EMHK12 Service manual

Speco SG-W300 instruction manual

Speco

Speco SG-W300 instruction manual

Velux KLI 110 instructions

Velux

Velux KLI 110 instructions

Belkin F8E855EA user manual

Belkin

Belkin F8E855EA user manual

Hama SK 120 Operating	 instruction

Hama

Hama SK 120 Operating instruction

CAMDEN CV-940 Series installation instructions

CAMDEN

CAMDEN CV-940 Series installation instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.