Select SelectLine Video 8 Digital User manual

Economy functional & digital audio access systems
Video 8 & 16
Digital
Installation Manual
07/06/2002
S
electLine
S
electine
Select Manufacturing Limited
Unit H1 - The Seedbed Centre - Wyncolls Road - Severalls Business Park - Colchester - Essex CO4 9HT
Telephone +44(0)1206 855800 - Facsimile +44(0)1206 855801
Digital Video
Digital Video
Revision 1.8 Date: 05/01/2009

Digital Video
Installation Manual
Engineers Notes

Digital
Systems
Digital Video
Installation Manual

Contents
Page
DIGITAL SYSTEMS:
DC Fail Secure and Fail Safe Lock Release Wiring Detail
Easikey 99, 1000 and 512
System Basic Overview
System with Landing Control
Riser/Landing Controller Overview
System Wiring Overview
Network, Power & Camera Wiring Detail
Digital Panel & Landing Panel Wiring Detail
Concierge 2036 board wiring detail
Flat Programming Form
Digital Panel Programming Instructions
System Summary
50VAC Power Supply wiring Detail
Main Controller Overview (Legacy)
Main Controller Overview (Current)
4
5
6
DIGITAL SYSTEMS WIRING DETAIL:
Privacy, Privacy Indicator and Door Monitoring
Amplifier Wiring Detail
Dual/Landing Panel Display Wiring Detail
Camera and Video Distributor Wiring Detail
Telephone, Amplifier, Strobe and Landing Panel
Camera and Video Distributor
Video Distribution wiring detail
Video Monitor and Strobe/Sounder wiring detail
DC Door Release
Fire Switch, Auxiliary, BST/GMT Time Clock,
Request To Exit wiring detail
PAC Proximity Access Landing Control wiring detail
7
7A
8
9
10
11
11A
12
13-15
19
20
21
22
23
24
24A
18
2-3
Digital Video
Installation Manual
- 2 -
Digital Video
Revision 1.08 Date: 05/01/2009
PAC Proximity Entrance Panel wiring detail
Easikey 99, 1000 and 512

Contents Page
25-27
System Controller Summary
System Default Settings
Programming Instructions
Programming and Example System Settings
Trades Time Clock
Controller to Single Entrance Panel
Controller to Entrance Panel Amplifier
Controller to Dual and Landing Entrance Panel
Controller to Telephone Handset
Telephone Handset to Strobe/Sounder
Controller to Door Release Monitor Contacts
Systems to Door Release (ac and dc)
Controller to Emergency Override Switch
Controller to Request To Exit Button
System Wiring Colour Codes
System Power Specification & Default Settings
User Monitor Instruction Leaflet Type: AM-1702/PID
Commissioning/Final Inspection Test Sheet
37
38
39
34-36
32-33
30-31
29
28
Digital Video
Installation Manual
Digital Time Clock
BST/GMT Time Clock
Digital Video
Revision 1.08 Date: 05/01/2009
- 3 -

Video Digital System Basic with 16 way Controllers Overview
Digital Video
Installation Manual
Riser/Landing Controller
A+D+H+J
M
Optional
Battery
A+D+H+J
Digital Interface
A -Single Earth 2.5mm Mains Type Cable (Continuity)
Cable Requirements
B - 2 Wire (1 Pair) 1mm Mains Type Cable (Lock Release)
D - 8 Wire (4 Pair) CW1308 0.5mm dia Multipair Cable (Minimum)
M - 12 Wire (6 Pair) CW1308 0.5mm dia Multipair Cable (Minimum)
C - 2 Wire (1 Pair) CW1308 0.5mm dia Multipair Cable (Minimum)
H - 2 Wire (1 Pair) 2.5mm Mains Type Cable (50V Power Rail)
J - Coax RG59 Video Cable (Video Coax)
Main Controller
A
J
B
M
J
J
Digital Interface
Battery D
Monitor
Strobe/Sounder
C
Strobe/Sounder
C
A+D+J
A+D+J
Digital Video
Installation Manual
1-16 way
Video
Distribution
Box
1-16 way
Video
Distribution
Box
- 4 -
Monitor
DOOR
OPEN
PRIVACY
ON
PRIVACY
S
elect ine
DOOR
OPEN
PRIVACY
ON
PRIVACY
S
elect ine
Fused Spur
TRADES
D
Digital Video
Revision 1.08 Date: 05/01/2009
1,C
2
6
9
PS
PL
DL
1,C
2
6
9
PS
PL
DL
1,C
2
6
9
PS
PL
DL
1,C
2
6
9
PS
PL
DL
1,C
2
6
9
PS
PL
DL
1,C
2
6
9
PS
PL
DL
1,C
2
6
9
PS
PL
DL
1,C
2
6
9
PS
PL
DL
1,C
2
6
9
PS
PL
DL
1,C
2
6
9
PS
PL
DL
1,C
2
6
9
PS
PL
DL
1,C
2
6
9
PS
PL
DL
1,C
2
6
9
PS
PL
DL
1,C
2
6
9
PS
PL
DL
1,C
2
6
9
PS
PL
DL ENTER
Data Enter
Button
& Indicator
FUNCTION
Function Switch Data Switch
Digital TimeClock
DATA
LINE 2
LINE 1
LINE 4
LINE 5
LINE 6
LINE 7
LINE 8
LINE 9
LINE 10
LINE 11
LINE 12
LINE 13
LINE 14
LINE 15
LINE 16
1,C
2
6
9
PS
PL
DL
LINE 3
5Amp Fuses
System Supply
Indicator
0V
0V
0V
MFL+
VC2
Mains Fail
MFL-
12V
12V
12V
B+
B
TC+
TC-
ON
12 3 4 5 6 7 8
ON
12 3 4 5 6 7 8
PANEL1
3
4
5
6
7
8
9
10
11
12
13
14
15
16
1
2
1
CC
DML
SBL
LS+
FCL
LS1
LS2
SA
SE
LC
LS -
2
+
RTE/T
RTE/T
RTE/T
RTE/T
DMS
DMS
DMS
DMS
PAC1+
PAC1-
0
PANEL2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
1
2
1
CC
DML
SBL
LS+
FCL
LS1
LS2
SA
SE
LC
LS-
2
+
PAC2+
PAC2-
TR
TR
0
8
12V
12V
0V
0V
9
16
R2
R1
R2
R1
R2
R1
R2
R1
R2
R1
R2
R1
R2
R1
R2
R1
R2
R1
R2
R1
R2
R1
R2
R1
R2
R1
R2
R1
R2
R1
R2
R1
Distribution
-+
Cam1P
CamDP1
CamDP2
CamR
VOUT
Cam2P
VC1
1,C
2
6
9
PS
PL
DL
1,C
2
6
9
PS
PL
DL
1,C
2
6
9
PS
PL
DL
1,C
2
6
9
PS
PL
DL
1,C
2
6
9
PS
PL
DL
1,C
2
6
9
PS
PL
DL
1,C
2
6
9
PS
PL
DL
1,C
2
6
9
PS
PL
DL
1,C
2
6
9
PS
PL
DL
1,C
2
6
9
PS
PL
DL
1,C
2
6
9
PS
PL
DL
1,C
2
6
9
PS
PL
DL
1,C
2
6
9
PS
PL
DL
1,C
2
6
9
PS
PL
DL
1,C
2
6
9
PS
PL
DL ENTER
Data Enter
Button
& Indicator
FUNCTION
Function Switch Data Switch
Digital TimeClock
DATA
LINE 2
LINE 1
LINE 4
LINE 5
LINE 6
LINE 7
LINE 8
LINE 9
LINE 10
LINE 11
LINE 12
LINE 13
LINE 14
LINE 15
LINE 16
1,C
2
6
9
PS
PL
DL
LINE 3
5Amp Fuses
System Supply
Indicator
0V
0V
0V
MFL+
VC2
Mains Fail
MFL-
12V
12V
12V
B+
B
TC+
TC-
ON
12 3 4 5 6 7 8
ON
12 3 4 5 6 7 8
PANEL1
3
4
5
6
7
8
9
10
11
12
13
14
15
16
1
2
1
CC
DML
SBL
LS+
FCL
LS1
LS2
SA
SE
LC
LS -
2
+
RTE/T
RTE/T
RTE/T
RTE/T
DMS
DMS
DMS
DMS
PAC1+
PAC1-
0
PANEL2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
1
2
1
CC
DML
SBL
LS+
FCL
LS1
LS2
SA
SE
LC
LS-
2
+
PAC2+
PAC2-
TR
TR
0
8
12V
12V
0V
0V
9
16
R2
R1
R2
R1
R2
R1
R2
R1
R2
R1
R2
R1
R2
R1
R2
R1
R2
R1
R2
R1
R2
R1
R2
R1
R2
R1
R2
R1
R2
R1
R2
R1
Distribution
-+
Cam1P
CamDP1
CamDP2
CamR
VOUT
Cam2P
VC1
To PAC
Controller
A+B+C
Emergency
Override
Emergency
Override
A+B+C
PUSH
TO EXIT
B+C

- 5 -
A+D+H+J
M
A+D+H+J
A -Single Earth 2.5mm Mains Type Cable (Continuity)
Cable Requirements
B - 2 Wire (1 Pair) 1mm Mains Type Cable (Lock Release)
D - 8 Wire (4 Pair) CW1308 0.5mm dia Multipair Cable (Minimum)
J - Coax RG59 Coax (Coaxial Cable)
M - 12 Wire (6 Pair) CW1308 0.5mm dia Multipair Cable (Minimum)
F - 20 Wire (15 Pair) CW1308 0.5mm dia Multipair Cable (Minimum)
C - 2 Wire (1 Pair) CW1308 0.5mm dia Multipair Cable (Minimum)
H - 2 Wire (1 Pair) 2.5mm Mains Type Cable (50V Power Rail)
Main Controller
Fused Spur
Battery
Strobe/Sounder
C
Monitor
A+D+J
M
A+B+F+J
A+B+F+J
Digital Interface
A+B+D+J
Landing Panel 1
Landing Panel 2
J
A+D+J
1-16 way
Video
Distribution
Box
1-16 way
Video
Distribution
Box
J
Digital Interface
Optional
Battery
Riser/Landing Controller
Video Digital System with 16 way Landing Controllers Overview
Digital Video
Installation Manual
Emergency
Override
Emergency
Override
PUSH
TO EXIT
PUSH
TO EXIT
A+B+C A+B+C
PUSH
TO EXIT
PUSH
TO EXIT
A+B+C
Emergency
Override
Emergency
Override
A+B+C
Magnetic Locks
with Door Contact
B+C
Magnetic Locks
with Door
Contact
B+C
Monitor
Strobe/Sounder
C
DOOR
OPEN
PRIVACY
ON
PRIVACY
S
elect ine
DOOR
OPEN
PRIVACY
ON
PRIVACY
S
elect ine
TRADES
D
Digital Video
Revision 1.08 Date: 05/01/2009
1,C
2
6
9
PS
PL
DL
1,C
2
6
9
PS
PL
DL
1,C
2
6
9
PS
PL
DL
1,C
2
6
9
PS
PL
DL
1,C
2
6
9
PS
PL
DL
1,C
2
6
9
PS
PL
DL
1,C
2
6
9
PS
PL
DL
1,C
2
6
9
PS
PL
DL
1,C
2
6
9
PS
PL
DL
1,C
2
6
9
PS
PL
DL
1,C
2
6
9
PS
PL
DL
1,C
2
6
9
PS
PL
DL
1,C
2
6
9
PS
PL
DL
1,C
2
6
9
PS
PL
DL
1,C
2
6
9
PS
PL
DL ENTER
Data Enter
Button
& Indicator
FUNCTION
Function Switch Data Switch
Digital Time Clock
DATA
LINE 2
LINE 1
LINE 4
LINE 5
LINE 6
LINE 7
LINE 8
LINE 9
LINE 10
LINE 11
LINE 12
LINE 13
LINE 14
LINE 15
LINE 16
1,C
2
6
9
PS
PL
DL
LINE 3
5Amp Fuses
System Supply
Indicator
0V
0V
0V
MFL+
VC2
Mains Fail
MFL-
12V
12V
12V
B+
B
TC+
TC-
ON
12 3 4 5 6 7 8
ON
12 3 4 5 6 7 8
PANEL1
3
4
5
6
7
8
9
10
11
12
13
14
15
16
1
2
1
CC
DML
SBL
LS+
FCL
LS1
LS2
SA
SE
LC
LS -
2
+
RTE/T
RTE/T
RTE/T
RTE/T
DMS
DMS
DMS
DMS
PAC1+
PAC1-
0
PANEL2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
1
2
1
CC
DML
SBL
LS+
FCL
LS1
LS2
SA
SE
LC
LS-
2
+
PAC2+
PAC2-
TR
TR
0
8
12V
12V
0V
0V
9
16
R2
R1
R2
R1
R2
R1
R2
R1
R2
R1
R2
R1
R2
R1
R2
R1
R2
R1
R2
R1
R2
R1
R2
R1
R2
R1
R2
R1
R2
R1
R2
R1
Distribution
-+
Cam1P
CamDP1
CamDP2
CamR
VOUT
Cam2P
VC1
1,C
2
6
9
PS
PL
DL
1,C
2
6
9
PS
PL
DL
1,C
2
6
9
PS
PL
DL
1,C
2
6
9
PS
PL
DL
1,C
2
6
9
PS
PL
DL
1,C
2
6
9
PS
PL
DL
1,C
2
6
9
PS
PL
DL
1,C
2
6
9
PS
PL
DL
1,C
2
6
9
PS
PL
DL
1,C
2
6
9
PS
PL
DL
1,C
2
6
9
PS
PL
DL
1,C
2
6
9
PS
PL
DL
1,C
2
6
9
PS
PL
DL
1,C
2
6
9
PS
PL
DL
1,C
2
6
9
PS
PL
DL ENTER
Data Enter
Button
& Indicator
FUNCTION
Function Switch Data Switch
Digital Time Clock
DATA
LINE 2
LINE 1
LINE 4
LINE 5
LINE 6
LINE 7
LINE 8
LINE 9
LINE 10
LINE 11
LINE 12
LINE 13
LINE 14
LINE 15
LINE 16
1,C
2
6
9
PS
PL
DL
LINE 3
5Amp Fuses
System Supply
Indicator
0V
0V
0V
MFL+
VC2
Mains Fail
MFL-
12V
12V
12V
B+
B
TC+
TC-
ON
12 3 4 5 6 7 8
ON
12 3 4 5 6 7 8
PANEL1
3
4
5
6
7
8
9
10
11
12
13
14
15
16
1
2
1
CC
DML
SBL
LS+
FCL
LS1
LS2
SA
SE
LC
LS -
2
+
RTE/T
RTE/T
RTE/T
RTE/T
DMS
DMS
DMS
DMS
PAC1+
PAC1-
0
PANEL2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
1
2
1
CC
DML
SBL
LS+
FCL
LS1
LS2
SA
SE
LC
LS-
2
+
PAC2+
PAC2-
TR
TR
0
8
12V
12V
0V
0V
9
16
R2
R1
R2
R1
R2
R1
R2
R1
R2
R1
R2
R1
R2
R1
R2
R1
R2
R1
R2
R1
R2
R1
R2
R1
R2
R1
R2
R1
R2
R1
R2
R1
Distribution
-+
Cam1P
CamDP1
CamDP2
CamR
VOUT
Cam2P
VC1
To PAC
Controller
A+B+C
Emergency
Override
Emergency
Override
A+B+C
PUSH
TO EXIT
B+C

Digital 50VAC Main Power Supply Overview
Digital Video
Installation Manual
- 6 -
230VAC to 50VAC Supply
Fused Spur
50VAC Rail
to a Controller
AC2
5Amp Fuse
AC1
Digital Video
Revision 1.08 Date: 05/01/2009

Digital Video
Installation Manual
Digital Main Controller Overview
Camera Supply x 5
18VDC
Monitor
Supply
To Video
Monitor
Video Output (Dist)
Video Output (Dist)
Riser Output
Riser Output
Digital Panel Input
Digital Panel Input
Lobby Camera2 Input
Lobby Camera1 Input
Lobby Camera2 Input
Lobby Camera1 Input
Panel Camera1 Input
Panel Camera1 Input
Panel Camera2 Input
Panel Camera2 Input
Mains Fail Output
to Door LED
3 x 12 VDC Auxilliary
Power Outputs
TX
TX
AC Power Input
from LV Transformer
Secondary Trades
Clock input
Mains Fail Indicator
Backup Battery
Input
PAC Entrance 2 Input
PAC Entrance 2 Input
TR
TR Trades Button
RESET
System Reset
Button
16 Apartment Inputs
Flat Called Indicator
Flat Called Indicator
Entrance Panel 1 Amplifier
Entrance Panel 1 Button Common
Entrance Panel 1 Busy & Enter Display
DC Lock Power
Healthy Indicator
Lock Released
Indicator
Call Indicator
Lock Released
Indicator
DC Lock Power
Healthy Indicator
12V DC Lock Release
Output ( N/O & N/C )
Request to Exit ( Timed )
Door Monitoring Switch
Request to Exit ( Timed )
Door Monitoring Switch
Entrance Panel 2 Amplifier
Entrance Panel 2 Button Common
Entrance Panel 2 Busy/Enter Display
12V DC Lock Release
Outputs ( N/O & N/C )
5 Amp Fuses
System Supply
Indicator
Auxilliary Supply
Indicator
0V
0V
0V
MFL+
MF
MFL-
12V
12V
12V
B+
B
TC+
TC-
FUNCTION
Function Switch Data Switch
DATA
ON
1 2 3 4 5 6 7 8
ON
1 2 3 4 5 6 7 8
PANEL 1
1
CC
DML
SBL
LS+
FCL
LS1
LS2
SA
SE
LC
LS -
2
+
RTE/T
RTE/T
RTE/T
RTE/T
DMS
DMS
DMS
DMS
Entrance Panel 1
Buttons
TR
TR Trades Button
3
4
5
6
7
8
9
10
11
12
13
14
15
16
1
2
PAC1+
PAC1 -
PAC Entrance 1 Input
PAC Entrance 1 Input
0
PANEL 2
1
CC
DML
SBL
LS+
FCL
LS1
LS2
SA
SE
LC
LS-
2
+
PAC2+
PAC2 -
0
PAC Jumpers
See page 11
PAC Jumpers
See page 11
Telephone Door open Tone ON/OFF Default OFF
Lock Supply + Input (12V-24VAC/DC
Lock Supply - Input (12V-24VAC/DC
Lock Supply + Input (12V-24VAC/DC
Lock Supply - Input (12V-24VAC/DC
Entrance Panel 2
Buttons
3
4
5
6
7
8
1
2
9
10
11
12
13
14
15
16
Monitor
Activation
5 Amp Fuse
Panel 1 Busy
18VDC Supply Indicator
18VDC
Distributor Supply
Panel 2 Busy
8
+
+
+
+
-
-
-
-
-
+
9
16
1
5
Vout
Scn
CamR
CamDP
Cam2P
Cam1P
Scn
Scn
Scn
Scn
Cam1L
Cam2L
Scn
Scn
1,C
2
6
9
PS
PL
DL
1,C
2
6
9
PS
PL
DL
1,C
2
6
9
PS
PL
DL
1,C
2
6
9
PS
PL
DL
1,C
2
6
9
PS
PL
DL
1,C
2
6
9
PS
PL
DL
1,C
2
6
9
PS
PL
DL
1,C
2
6
9
PS
PL
DL
1,C
2
6
9
PS
PL
DL
1,C
2
6
9
PS
PL
DL
1,C
2
6
9
PS
PL
DL
1,C
2
6
9
PS
PL
DL
1,C
2
6
9
PS
PL
DL
1,C
2
6
9
PS
PL
DL
1,C
2
6
9
PS
PL
DL
LINE 2
LINE 1
LINE 4
LINE 5
LINE 6
LINE 7
LINE 8
LINE 9
LINE 10
LINE 11
LINE 12
LINE 13
LINE 14
LINE 15
LINE 16
1,C
2
6
9
PS
PL
DL
LINE 3
ENTER
Data Enter
Button
& Indicator
R2
R1
R2
R1
R2
R1
R2
R1
R2
R1
R2
R1
R2
R1
R2
R1
R2
R1
R2
R1
R2
R1
R2
R1
R2
R1
R2
R1
R2
R1
R2
R1
Sbl1
Sbl2
Distribution
-+
BST/GMT Output
BST/GMT Input
Speaker Output
Speaker Input
AC1
TXP
TXP
50Vac Riser Output
Fuse 3.15A
Anti surge
50VAC Supply Indicator
Data Status Indicator
Speech Active Indicator
50VAC 50Vac Riser Input
50Vac Riser Output
50Vac Riser Input
AC1
AC2
AC2
CTS
OV
OV
TC
TC
CTS
Data Select
Data Select
Data Output
Data Input
Mic Output
0V Output
0V Input
Mic Input
SD
SD
2
2
1
1
Note:
Fitted Links will give a
12VDC Lock output. With the Links
removed a seperate 12VDC/AC
-24VDC/AC Lock Power Supply can
be connected to LS1(+) and LS2 ( - )
TIME CLOCK
- 7 -
Digital Video
Revision 1.08 Date: 05/01/2009

Digital Video
Installation Manual
Digital Main Controller Overview
Camera
Supply
x 2
18VDC
Monitor
Supply
To Video
Monitor
Mains Fail Output
to Door LED
3 x 12 VDC Auxilliary
Power Outputs
TX
TX
AC Power Input
from LV Transformer
Secondary Trades
Clock input
Mains Fail Indicator
Video Control (Pre wired)
Backup Battery
Input
PAC Entrance 2 Input
PAC Entrance 2 Input
TR
TR Trades Button
RESET
System Reset
Button
16 Apartment Inputs
Flat Called Indicator
Flat Called Indicator
Entrance Panel 1 Amplifier
Entrance Panel 1 Button Common
Entrance Panel 1 Busy & Enter Display
DC Lock Power
Healthy Indicator
Lock Released
Indicator
Call Indicator
Lock Released
Indicator
DC Lock Power
Healthy Indicator
12V DC Lock Release Output ( N/O & N/C )
Request to Exit ( Timed )
Request to Exit ( Timed )
Door Monitoring Switch
Entrance Panel 2 Button Common
Entrance Panel 2 Busy/Enter Display
12V DC Lock Release
Outputs ( N/O & N/C )
5 Amp Fuses
System Supply
Indicator
Auxilliary Supply
Indicator
Panel Amplifier Active
Panel Amplifier Active
0V
0V
0V
MFL+
VC2
VC1
MFL-
12V
12V
12V
B+
B
TC+
TC-
FUNCTION
Function Switch Data Switch
DATA
ON
1 2 3 4 5 6 7 8
ON
1 2 3 4 5 6 7 8
PANEL 1
1
CC
DML
SBL
LS+
FCL
LS1
LS2
SA
SE
LC
LS -
2
+
RTE/T
RTE/T
RTE/T
RTE/T
DMS
DMS
DMS
DMS
Sub Entrance
Panel 1 Buttons
TR
TR Trades Button
3
4
5
6
7
8
9
10
11
12
13
14
15
16
1
2
PAC1+
PAC1 -
PAC Entrance 1 Input
PAC Entrance 1 Input
0
PANEL 2
1
CC
DML
SBL
LS+
FCL
LS1
LS2
SA
SE
LC
LS-
2
+
PAC2+
PAC2 -
0
Telephone Door Release Tone ON/OFF Default OFF
Lock Supply + Input (12V-24VAC/DC
Lock Supply - Input (12V-24VAC/DC
Lock Supply + Input (12V-24VAC/DC
Lock Supply - Input (12V-24VAC/DC
Sub Entrance
Panel 2 Buttons
3
4
5
6
7
8
1
2
9
10
11
12
13
14
15
16
Monitor
Activation
5 Amp Fuse
18VDC
Supply
Indicator
18VDC
Distributor
Supply 12VDC
Camera
Supply
18 - 24VDC
Monitor
Supply
8
12V
12V
0V
0V
9
16
Output To Video
Distributors
Video Output
To Next Controller
Digital Panel
2 Input
Digital Panel
1 Input
Func Panel
Camera1 Input
Functional Panel
Camera 2 Input
1,C
2
6
9
PS
PL
DL
1,C
2
6
9
PS
PL
DL
1,C
2
6
9
PS
PL
DL
1,C
2
6
9
PS
PL
DL
1,C
2
6
9
PS
PL
DL
1,C
2
6
9
PS
PL
DL
1,C
2
6
9
PS
PL
DL
1,C
2
6
9
PS
PL
DL
1,C
2
6
9
PS
PL
DL
1,C
2
6
9
PS
PL
DL
1,C
2
6
9
PS
PL
DL
1,C
2
6
9
PS
PL
DL
1,C
2
6
9
PS
PL
DL
1,C
2
6
9
PS
PL
DL
1,C
2
6
9
PS
PL
DL
LINE 2
LINE 1
LINE 4
LINE 5
LINE 6
LINE 7
LINE 8
LINE 9
LINE 10
LINE 11
LINE 12
LINE 13
LINE 14
LINE 15
LINE 16
1,C
2
6
9
PS
PL
DL
LINE 3
ENTER
Data Enter
Button
& Indicator
R2
R1
R2
R1
R2
R1
R2
R1
R2
R1
R2
R1
R2
R1
R2
R1
R2
R1
R2
R1
R2
R1
R2
R1
R2
R1
R2
R1
R2
R1
R2
R1
Distribution
-+
BST/GMT Output
BST/GMT Input
Speaker Output
Speaker Input
AC1
TXP
TXP
50Vac Riser Output
Fuse 3.15A
Anti surge
50VAC Supply Indicator
Data Status Indicator
Speech Active Indicator
50VAC 50Vac Riser Input
50Vac Riser Output
50Vac Riser Input
AC1
AC2
AC2
CTS
OV
OV
TC
TC
CTS
Data Select
Data Select
Data Output
Data Input
Mic Output
0V Output
0V Input
Mic Input
SD
SD
2
2
1
1
Note:
Fitted Links will give a
12VDC Lock output. With the Links
removed a seperate 12VDC/AC
-24VDC/AC Lock Power Supply can
be connected to LS1(+) and LS2 ( - )
TIME CLOCK
SML2000-3
SML2021-3
Cam1P
CamDP1
CamDP2
CamR
VOUT
Cam2P
Doors
Lock Release Tone and
Door Open Tone Adjustment
1 2
1 & 2 ON No PAC connected
2 & 3 ON PAC connected
(RED & BLACK must
BOTH be moved).
12 3
12 3
Entrance Panel 2 Amplifier
12VDC Lock Release from
PAC Controller to be
programmed to 2 seconds
Fail Safe.
Door Open Indicator
12VDC
Supply
Indicator
- 7A -
Digital Video
Revision 1.08 Date: 05/01/2009
Progressive
Ring Tone
Default ON
Door Monitoring Switch
PAC Jumpers
1 & 2 ON No PAC connected
2 & 3 ON PAC connected
(RED & BLACK must BOTH be moved).
12 3
12 3

Digital Video
Installation Manual
Digital Riser Controller Overview
Camera
Supply
x 2
18VDC
Monitor
Supply
To Video
Monitor
Mains Fail Output
to Door LED
3 x 12 VDC Auxilliary
Power Outputs
TX
TX
AC Power Input
from LV Transformer
Secondary Trades
Clock input
Mains Fail Indicator
Video Control (Pre wired)
Backup Battery
Input
PAC Entrance 2 Input
PAC Entrance 2 Input
TR
TR Trades Button
FUNCTION
Function Switch Data Switch
DATA
RESET
System Reset
Button
16 Apartment Inputs
Flat Called Indicator
Flat Called Indicator
Entrance Panel 1 Amplifier
Entrance Panel 1 Button Common
Entrance Panel 1 Busy & Enter Display
DC Lock Power
Healthy Indicator
Lock Released
Indicator
Call Indicator
Lock Released
Indicator
DC Lock Power
Healthy Indicator
12V DC Lock Release Output ( N/O & N/C )
Request to Exit ( Timed )
Request to Exit ( Timed )
Door Monitoring Switch
Entrance Panel 2 Button Common
Entrance Panel 2 Busy/Enter Display
12V DC Lock Release
Outputs ( N/O & N/C )
5 Amp Fuses
System Supply
Indicator
Auxilliary Supply
Indicator
Panel Amplifier Active
Panel Amplifier Active
0V
0V
0V
MFL+
VC2
VC1
MFL-
12V
12V
12V
B+
B
TC+
TC-
ON
1 2 3 4 5 6 7 8
ON
1 2 3 4 5 6 7 8
PANEL 1
1
CC
DML
SBL
LS+
FCL
LS1
LS2
SA
SE
LC
LS -
2
+
RTE/T
RTE/T
RTE/T
RTE/T
DMS
DMS
DMS
DMS
Sub Entrance
Panel 1 Buttons
TR
TR Trades Button
3
4
5
6
7
8
9
10
11
12
13
14
15
16
1
2
PAC1+
PAC1 -
PAC Entrance 1 Input
PAC Entrance 1 Input
0
PANEL 2
1
CC
DML
SBL
LS+
FCL
LS1
LS2
SA
SE
LC
LS-
2
+
PAC2+
PAC2 -
0
Lock Supply + Input (12V-24VAC/DC
Lock Supply - Input (12V-24VAC/DC
Lock Supply + Input (12V-24VAC/DC
Lock Supply - Input (12V-24VAC/DC
Sub Entrance
Panel 2 Buttons
3
4
5
6
7
8
1
2
9
10
11
12
13
14
15
16
Monitor
Activation
8
12V
12V
0V
0V
9
16
1,C
2
6
9
PS
PL
DL
1,C
2
6
9
PS
PL
DL
1,C
2
6
9
PS
PL
DL
1,C
2
6
9
PS
PL
DL
1,C
2
6
9
PS
PL
DL
1,C
2
6
9
PS
PL
DL
1,C
2
6
9
PS
PL
DL
1,C
2
6
9
PS
PL
DL
1,C
2
6
9
PS
PL
DL
1,C
2
6
9
PS
PL
DL
1,C
2
6
9
PS
PL
DL
1,C
2
6
9
PS
PL
DL
1,C
2
6
9
PS
PL
DL
LINE 2
LINE 1
LINE 4
LINE 5
LINE 6
LINE 7
LINE 8
LINE 9
LINE 10
LINE 11
LINE 12
LINE 13
LINE 14
1,C
2
6
9
PS
PL
DL
LINE 3
R2
R1
R2
R1
R2
R1
R2
R1
R2
R1
R2
R1
R2
R1
R2
R1
R2
R1
R2
R1
R2
R1
R2
R1
R2
R1
R2
R1
R2
R1
R2
R1
BST/GMT Output
BST/GMT Input
Speaker Output
Speaker Input
AC1
TXP
TXP
50Vac Riser Output
Fuse 3.15A
Anti surge
50VAC Supply Indicator
Data Status Indicator
Speech Active Indicator
50VAC 50Vac Riser Input
50Vac Riser Output
50Vac Riser Input
AC1
AC2
AC2
CTS
OV
OV
TC
TC
CTS
Data Select
Data Select
Data Output
Data Input
Mic Output
0V Output
0V Input
Mic Input
SD
SD
2
2
1
1
Note:
Fitted Links will give a
12VDC Lock output. With the Links
removed a seperate 12VDC/AC
-24VDC/AC Lock Power Supply can
be connected to LS1(+) and LS2 ( - )
Doors
Lock Release Tone and
Door Open Tone Adjustment
1 2
1 & 2 ON No PAC connected
2 & 3 ON PAC connected
(RED & BLACK must
BOTH be moved).
12 3
12 3
Entrance Panel 2 Amplifier
12VDC Lock Release from
PAC Controller to be
programmed to 2 seconds
Fail Safe.
Door Open Indicator
ENTER
Data Enter
Button
& Indicator
5 Amp Fuse
18VDC
Supply
Indicator
18VDC
Distributor
Supply 12VDC
Camera
Supply
18 - 24VDC
Monitor
Supply
Output To Video
Distributors
Video Output
To Next Controller
Digital Panel
2 Input
Digital Panel
1 Input
Func Panel
Camera1 Input
Functional Panel
Camera 2 Input
1,C
2
6
9
PS
PL
DL
1,C
2
6
9
PS
PL
DL
LINE 15
LINE 16
Distribution
-+
Cam1P
CamDP1
CamDP2
CamR
VOUT
Cam2P
12VDC
Supply
Indicator
- 8 -
Digital Video
Revision 1.08 Date: 05/01/2009
Door Monitoring Switch
Progressive
Ring Tone
Default ON
Telephone Door Release Tone ON/OFF Default OFF
PAC Jumpers
1 & 2 ON No PAC connected
2 & 3 ON PAC connected
(RED & BLACK must BOTH be moved).
12 3
12 3
SML2000-4
SML2021-4

- 9 -
Digital System Wiring Overview
Door Contact Switch
Request to Exit Switch
(Timed)
Sw1
Prog
External Volume
Adjustment
Internal Volume
Adjustment
Sw2
Up
Load
Sw3
Down
Load
To Next Riser/Landing
Controller
50Volt Power Rail
Data Line
Digital Entrance Panel
1
2
+VE
-VE
Vout
SCN
SCN
SCN
RTE T
RTE T
DMS
DMS
PAC
CTS
CTS
0V
Stb+
Stb-
SE
SA
LC
LS1
LS2
SD
SD
Cam1
Cam2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
1
2
1
CC
2
+
TR
TR
TR
TR
FUNCTIONAL ENTRANCE PANEL
3
4
5
6
7
8
9
10
11
12
13
14
15
16
1
2
1
CC
DML
SBL
2
+
0
0
(See Amplifier wiringdetail)
(SeeCamera wiring detail)
(See Amplifier wiring detail)
DML
-0
SBL
LANDING ENTRANCE PANEL
To Video Input
To Camera Power Input
(See Video Monitor wiring detail)
PANEL 1
PANEL 2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
1
2
1
1,C
2
6
9
PS
PL
DL
1,C
2
6
9
PS
PL
DL
1,C
2
6
9
PS
PL
DL
1,C
2
6
9
PS
PL
DL
1,C
2
6
9
PS
PL
DL
1,C
2
6
9
PS
PL
DL
1,C
2
6
9
PS
PL
DL
1,C
2
6
9
PS
PL
DL
1,C
2
6
9
PS
PL
DL
1,C
2
6
9
PS
PL
DL
1,C
2
6
9
PS
PL
DL
1,C
2
6
9
PS
PL
DL
1,C
2
6
9
PS
PL
DL
1,C
2
6
9
PS
PL
DL
1,C
2
6
9
PS
PL
DL
1,C
2
6
9
PS
PL
DL
CC
DML
SBL
RTE
RTE
FS
FS
SA
SE
LC
LAC ac
LAC
RTE T
2
+
Tx
Rx
OV
OV
OV
OV
TX
TX
B+
B--
FUNCTION
Digital Time Clock
DATA
TC
TC
12V
12V
12V
1
CC
DML
SBL
RTE
RTE
FS
FS
SA
SE
LC
LAC
LAC
RTE T
RTE T
DMS
ac
DMS
RTE T
DMS
DMS
2
+
LINE 2
LINE 1 LINE 3
LINE 4
LINE 5
LINE 6
LINE 7
LINE 8
LINE 9
LINE 10
LINE11
LINE 12
LINE 13
LINE 14
LINE 15
LINE 16
ENTER
RESET
Door Contact Switch
Request to Exit Switch
(Timed)
Lock Release
ac/dc
PAC
TR
TR
PAC
TR
TR
Video Monitor
System Controller
0
0
dc
dc
2 Amp Fuses
Lock Release Button
Privacy Button
Privacy On Indicator
Door Monitoring Indicator
75 Ohm (End of Line)
Resistor
R1
R2
1.C
2
6
9
PS
PL
DL
AM-1202/PID Video Monitor
connection plate
Monitor
Video Coax
To Video
Distributor
L
I
N
E
1
R2
R1
R2
R1
R2
R1
R2
R1
R2
R1
R2
R1
R2
R1
R2
R1
R2
R1
R2
R1
Vout
Scn
CamR
CamDP
Cam2P
Cam1P
Scn
Scn
Scn
Scn
R2
R1
R2
R1
R2
R1
R2
R1
R2
R1
R2
R1
+
+
+
+
-
-
-
-
-
+
Camera Power x 5
Camera Power x 5
Cam1L
Cam2L
Scn
Scn Distribution
-+
Sbl1
Sbl2
Digital Video
Installation Manual
Digital Video
Revision 1.08 Date: 05/01/2009

Digital Video
Installation Manual
- 10 -
Note:
See page 18 for PAC connections and
jumper positions.
Pre-wired
To Panel Amplifier
+
_
1
2
Display
BUSY
FLAT CALLED
TALK NOW
ENTER
AC1
TXP
TXP
Fuse 3.15A
Anti surge
50VAC Supply Indicator
AC1
AC2
AC2
CTS
OV
OV
TC
TC
CTS
SD
SD
2
2
1
1
AC1
TXP
TXP
Fuse 3.15A
Anti surge
50VAC Supply Indicator
AC1
AC2
AC2
CTS
OV
OV
TC
TC
CTS
SD
SD
2
2
1
1
Main Controller
Riser Controller
Next Riser
Controller
0V
0V
0V
MFL+
MF
MFL-
12V
12V
12V
B+
B
TX
TX
TC+
TC-
15
16
PAC2+
PAC2 -
TR
TR
Note:
Pre-wired for 12VDC Lock Output.
If a 12VAC/DC Lock Output is required use LS1& LS2
with a secondary power Supply.
If a Volt free contact is required to trigger a PAC Controller
RTE then remove both links and use LS1 & SA for Normally
Closed and LS1 & SE for Normally Open.
This will give Volt free contacts when a Lock release is
initiated from the Telephone/Monitor or system RTE is
pressed
For Fail Secure (SE)
Lock Releases
wire N/O to RTE/T only.
Common
1
Normally
Open
4
Normally
Closed
2
RTE
N/C
N/O
Magnetic Locks
with Door Contact
B+C
Emergency Override Switch
Digital Entrance Panel
1
2
+VE
-VE
12V
12V
0V
Sw1
Prog
Sw2
Up
Load
Sw3
Down
Load
LS2
PAC +
LS1
LC
SA
SE
Stb-
Stb+
0V
CTS
SD
DMS
DMS
RTE/T
RTE/T
Vout
0V
SCN
Flat Programming
Button
Board Healthy
Indicator
12V
0V
SCN
SIG
CAM2 (Lobby)
12V
0V
SCN
SIG
CAM1(Panel)
+
_
1
2
Pcb. 2024
With DDA
facility
PAC relay healthy
indicator
12 3
12 3
Door Open Tone
Control
PAC -
12VDC Lock Release from PAC
Controller to be programmed to
2 seconds Fail Safe.
If the above PAC option is required
please move both jumpers to 2 & 3.
Digital Video
Revision 1.08 Date: 05/01/2009
Network and Power wiring detail

Note:
To be fitted if a 12VDC Lock Release is required
If 12Vac or 24VAC/DC is required then use terminal
LS1 & LS2 and a secondary power supply.
Vout
Scn
CamR
CamDP
Cam2P
Cam1P
Cam1L
Cam2L
Scn
Scn
Scn
Scn
Scn
Scn
Video Output
Video Output
Panel Camera1 Input
Panel Camera1 Input
Panel Camera2 Input
Panel Camera2 Input
Camera Supply x 5
+
+
+
+
-
-
-
-
-
+
Note:
See Camera detail
Busy Display
Digital Video
Installation Manual
Sw1
Prog
Sw2
Up
Load
Sw3
Down
Load
LS2
LS1
LC
SA
SE
Stb-
Stb+
0V
CTS
SD
DMS
PAC+
PAC-
DMS
RTE T
RTE T
Vout
SCN
Flat Programming
Button
12V
0V
SCN
SIG
CAM2 (Lobby) CAM1(Panel)
Digital Entrance Panel wiring detail
Main Controller
Network Interface
Board
Door Alarm Strobe/
Sounder
Door Monitoring Contacts
+12-24VDC/AC LockPower Input Supply
-12-24VDC/AC Lock Power Input Supply
Entrance Panel Video Input
1
2
+VE
-VE
12V
12V
0V
0V
+
_
1
2
12V
0V
SCN
SIG
Entrance Panel 1
Camera
TC+
TC-
SIG
SCN
Emergency Override Switch
For Fail Safe (SA) Lock Releases.
Common
1
Normally
Open
4
Normally
Closed
2
RTE
N/C
N/O
SA
LC
Main or Landing Video Controller Landing Entrance Panel
Landing Entrance Video Panel wiring detail
PANEL 1
3
4
5
6
7
8
9
10
11
12
13
14
15
16
1
2
Brown of White
White of Brown
Slate of White
White of Slate
Red of Orange
Orange of Red
Green of Red
Red of Green
Brown of Red
Red of Brown
Black of Blue
Blue of Black
Black of Orange
Orange of Black
Green of Black
Black of Green
Blue of White
White of Blue
Blue of Red and Red Blue
White of Orange and Orange of White
Slate of Red and Red of Slate
Black of Slate
Slate of Black
1
CC
DML
SBL
FCL
2
+
FCL
DML
SBL
1
+
-
Black of Brown
Brown of Black
TR
TR
0
0
SBL1
SBL2
Magnetic Locks
with Door Contact
12 3
12 3
Door Open Tone
Control
- 11 -
Digital Video
Revision 1.09 Date: 15/12/2010
1
2
+
-
To PAC
Controller
12V
12V
12V
0V
3 x 12VDC Auxiliary
Power Outputs
0V
0V
Note:
See Amplifier detail
Page 8
To
Controller
Panel Amplifier
To
Controller
-
+
1
2
Intercall
Functional

Note:
To be fitted if a 12VDC Lock Release is required
If 12Vac or 24VAC/DC is required then use terminal
LS1 & LS2 and a secondary power supply.
Digital Video
Installation Manual
Sw1
Prog
Sw2
Up
Load
Sw3
Down
Load
LS2
LS1
LC
SA
SE
Stb-
Stb+
0V
CTS
SD
DMS
PAC+
PAC-
DMS
RTE T
RTE T
Vout
SCN
Flat Programming
Button
12V
0V
SCN
SIG
CAM2 (Lobby) CAM1(Panel)
Digital Entrance Panel wiring detail
Main Controller
12V
12V
12V
0V
3 x 12VDC Auxiliary
Power Outputs
0V
0V
Network Interface
Board
Door Alarm Strobe/
Sounder
Door Monitoring Contacts
+12-24VDC/AC LockPower Input Supply
-12-24VDC/AC Lock Power Input Supply
Entrance Panel Video Input
1
2
+VE
-VE
12V
12V
0V
0V
+
_
1
2
12V
0V
SCN
SIG
Entrance Panel 1
Camera
TC+
TC-
SIG
SCN
Emergency Override Switch
For Fail Safe (SA) Lock Releases.
Common
1
Normally
Open
4
Normally
Closed
2
RTE
N/C
N/O
SA
LC
Magnetic Locks
with Door Contact
12 3
12 3
Door Open Tone
Control
- 11A -
Digital Video
Revision 1.09 Date: 15/12/2010
Digital Panel
1 Input
To PAC
Controller
CamDP1
Functional Video Panel with DDA display wiring detail
Video Entrance Panel
PANEL 1
3
4
5
6
7
8
9
10
11
12
13
14
15
16
1
2
Brown of White
Note:
See Camera detail
White of Brown
Slate of White
White of Slate
Red of Orange
Orange of Red
Green of Red
Red of Green
Brown of Red
Red of Brown
Black of Blue
Blue of Black
Black of Orange
Orange of Black
Green of Black
Black of Green
Blue of White
White of Blue
Blue of Red and Red of Blue
White of Orange and Orange of White
Slate of Red and Red of Slate
Black of Slate
Slate of Black
Red of Blue
Black of Brown
Brown of Black
1
CC
DML
SBL
FCL
2
+
TR
TR
0
Camera
FCL
DML
SBL
1
+
-
0
BUSY
FLAT CALLED
TALK NOW
ENTER
Note:
See page 8 for
wiring detail
Note:
See Amplifier detail
Page 8
1
2
+
-
Camera
Supply
x 2 12V
12V
0V
0V
Distribution
-+
Output To Video
Distributors
Video Output
To Next Controller
Digital Panel
2 Input
Digital Panel
1 Input
Func Panel
Camera1 Input
Functional Panel
Camera 2 Input Cam1P
CamDP1
CamDP2
CamR
VOUT
Cam2P
System Video Controller
Panel Amplifier
To
Controller
-
+
1
2
Intercall
Functional

Digital Entrance Panel
Pre-wired
To Panel Amplifier
Main Controller
0V
0V
12V
12V
C
W
W
W
W
O
O
O
O
Aux1In
Aux2In
Aux3In
Aux4In
Aud1
Aud1
Aud2
Aud2
V Out
A1 OutA2OutA3OutA4Out
V in
V in
C
C
C
CTS
12V
0V
CTS
12V
0V
12V
12V
N/O - N/C Auxiliary Output 1
N/O - N/C Auxiliary Output 2
N/O - N/C Auxiliary Output 3
N/O - N/C Auxiliary Output 4
Audio Microphone Transmission
Hard Wired
Input Switches
Audio Speaker Transmission
Video Input from Digital Panel
Video Output to Concierge
Auxiliary Input 1
Auxiliary Input 2
Auxiliary Input 3
Auxiliary Input 4
Switched via
the Data Line
0V
V Out
1
2
SD
0V
1
2
SD
0V
0V
S1
S2
L1
L2
A0
01
A2
12VDC Supply from 12VDC
ControllerAuxiliary
Auxiliary Output
On/Off
Remote Speech
Adjustment
SML-2036
Building Interface card
A
G
R
T
RS232
D
C
B
RS475
RS232 Transmission Input/Output
RS485 Transmission Input/Output
Concierge Building Interface Card (Multi-Building) wiring detail
PC Input/Output
Controller 2
Interface
Card
AC1
TXP
TXP
Fuse 3.15A
Anti surge
50VAC Supply Indicator
AC1
AC2
AC2
CTS
OV
OV
TC
TC
CTS
SD
SD
2
2
1
1
Controller 2
Interface
Card
AC1
TXP
TXP
Fuse 3.15A
Anti surge
50VAC Supply Indicator
AC1
AC2
AC2
CTS
OV
OV
TC
TC
CTS
SD
SD
2
2
1
1
+
_
1
2
Display
BUSY
FLAT CALLED
TALK NOW
ENTER
+
_
1
2
1
2
+VE
-VE
12V
12V
0V
Sw1
Prog
Sw2
Up
Load
Sw3
Down
Load
LS2
PAC+
PAC-
LS1
LC
SA
SE
Stb-
Stb+
0V
CTS
SD
DMS
DMS
RTE/T
RTE/T
Vout
0V
SCN
Flat Programming
Button
Board Healthy
Indicator
12V
0V
SCN
SIG
CAM2 (Lobby)
12V
0V
SCN
SIG
CAM1(Panel)
Telephone
Audio to and
from Concierge
DIGITAL PANEL
INTERFACE
Digital Entrance Panel
PAC relay
Healthy Indicator
1 2 3
1 2 3
Door Open
Tone Control
- 11B -
Digital Video
Installation Manual
Digital Video
Revision 1.08 Date: 05/01/2009

Video Digital System Flat Programming Form
Digital Video
Installation Manual
Note: Remember to PRESS the Enter button after setting Dill switch positions.
- 12-
1 3 4 5 6 7 82 1 3 4 5 6 7 82
1 3 4 5 6 7 82 1 3 4 5 6 7 82 1 3 4 5 6 7 82 1 3 4 5 6 7 82 1 3 4 5 6 7 82
1 3 4 5 6 7 82 1 3 4 5 6 7 82 1 3 4 5 6 7 82
FUNCTION SWITCH
1 13 34 45 56 67 78 82 2
DATA SWITCH DATA SWITCH
Controller ControllerControllerControllerController
1 3 4 5 6 7 82
DATA SWITCH
1 3 4 5 6 7 82
DATA SWITCH
1 3 4 5 6 7 82
DATA SWITCH
FUNCTION SWITCH FUNCTION SWITCH FUNCTION SWITCH FUNCTION SWITCH
1 2 3 4 5
FUNCTION SWITCH
1 13 34 45 56 67 78 82 2
DATA SWITCH DATA SWITCH
Controller ControllerControllerControllerController
13 4 5 6 7 82
DATA SWITCH
1 3 4 5 6 7 82
DATA SWITCH
1 3 4 5 6 7 82
DATA SWITCH
FUNCTION SWITCH FUNCTION SWITCH FUNCTION SWITCH FUNCTION SWITCH
6 7 8 9 10
ON (1)
OFF(0)
OFF(0)
ON (1)
ON (1)
OFF(0)
ON (1)
OFF(0)
Line No. Flat Stb Priv
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
Stb PrivFlat Stb PrivFlat Stb PrivFlat Stb PrivFlat
Line No. Flat Stb Priv
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
Stb PrivFlat Stb PrivFlat Stb PrivFlat Stb PrivFlat
Digital Video
Revision 1.08 Date: 05/01/2009

- 13 -
Digital Video
Installation Manual
Digital Entrance Panel Programming Instructions
System Function Programming
Function 1 (Lock Release)
Function 2 (Door Open Alarm Duration)
Function 3 (Door Open Alarm Delay)
Function 4 (Service Access Code)
Function 5 (Engineering Access Code)
Press 1 on the Digital Panel keypad and then press the PROG button.
Enter between 1 and 255 seconds and press CALL.
This will set the Lock Release duration time for that Panel.
Press 2 on the Digital Panel keypad and then press the PROG button.
Enter between 1 and 255 minutes and press CALL.
This will set the Door Alarm Duration time.
Press 3 on the Digital Panel keypad and then press the PROG button.
Enter between 1 and 255 minutes and press CALL.
This will set the Door Alarm Delay time.
Press 4 on the Digital Panel keypad and then press the PROG button.
Enter up to 5 digits and press CALL.This will establish a Service Access Code.
If a 5 digit service code has already been entered the Digital Panel will display AC?
alternating with the remaining 4 numbers, i.e. AC1 - 2345.
This can, if required be deleted by pressing the CANCEL button.
Press the TRADES button, Enter Code and then press Trades or Call to release the Door.
Press 5 on the Digital Panel keypad and then press the PROG button.
Enter up to 5 digits and press CALL.This will establish an Engineering Access Code.
If a 5 digit engineering code has already been entered the Digital Panel will display
EA1 alternating with the remaining 4 numbers, i.e. EA1 - 2345.
This can, if required be deleted by pressing the CANCEL button.
Press the TRADES button, Enter Code and then press Trades or Call to release the Door.
Function Description Parameters Notes
1Lock Release Time 1 - 255 Seconds
2
Door Alarm Delay Time
1 - 255 Minutes
10
27
Panel Facility Configuration
Erase All Memory and Reset -
9Communication Test facility - Controller Interface Data Continuity Test
90 Second Erase on a 30 count will automatically re-set the default values
Alpha Numeric, Cameras, Concierge and Door Tone On/Off
8Set Digital Panel Number 1 - 9
A F
7Call Duration Time 1 - 255 Seconds
6Monitor Ring Time 1 - 255 Seconds
5Engineers Access Code (EA) 1 - 5 Digits Code + Trades to release door
4Service Access Code (AC) 1 - 5 Digits Code + Trades to release door
3
Door Open Duration Time
1 - 255 Minutes Zero minutes will disable the Door Alarm
Function 6 (Telephone Ring Time)
Press 6 on the Digital Panel keypad and then press the PROG button.
Enter between 1 and 255 seconds and press CALL.
This can if required be deleted by using the CANCEL button.
This will set the Digital Panel to Telephone ring time.
Function 7 (Call Duration Time)
Press 7 on the Digital Panel keypad and then press the PROG button.
Enter between 1 and 255 seconds and press CALL.
This can if required be deleted by using the CANCEL button.
This will set the Digital Panel to Telephone Call Duration time.
Digital Video
Revision 1.08 Date: 05/01/2009

- 14 -
Digital Video
Installation Manual
Digital Entrance Panel Programming Instructions cont...
System Function Programming cont...
Press 8 on the Digital Panel keypad and then press the PROG button.
Enter from 1 to a maximum of 9 depending on the position of the Digital Panel in the system
and press CALL.
If required a set Panel position can be deleted by using the CANCEL button.
This will set the Digital Panel position in a Single or Multi Entrance system.
Press 9 on the Digital Panel keypad and then press the PROG button.
The display will now scroll through all connected Controller Interfaces on the system
only pausing when data continuity is broken.
This will establish all Controllers have continuity of Data.
Press 10 on the Digital Panel keypad and then press the PROG button.
The display will now show the factory default setting as shown on the rear of the Digital panel. If there is a
requirement to change the default mode then press CANCEL, enter the new code number and press CALL
to accept the change.
Press 27 on the Digital Panel keypad and then press the PROG button. This will put the system into
erase mode. Erase mode will be indicated by the Display initially reading E.000 and then following on
with a count of 30. The system will not reset itself to default at 30. To initiate the default setting,
the batteries must be disconnected and the Fused spur must be switched off. This must be for a period
of no less than 5 seconds or the extinguishing of the on board healthy LED’s
Once instigated the erasing of the system cannot be stopped until completion (Approximately
90 seconds).
Note:
Default settings are as follows,
Function 1 Lock Time 10 seconds
Function 2 Door Alarm Delay Time OFF
Function 3 Door Open Duration Time OFF
Function 4 Service Access Code Blank
Function 5 Engineers Access Code Blank
Function 6 Telephone Ring Time 30 seconds
Function 7 Call Duration Time 30 seconds
Function 8 Digital Panel Position No. 1
Function 10 Panel Facility Configuration 007 (No Door Open Tones)
Note:
Function 8 (Setting Digital Panel Number(s)
Function 9 (Data Communication Test Facility)
Function 10 (Panel Facility Configuration)
Function 27 (Erase All Memory and Reset System to Default)
On a Multi Entrance system it is important that all Digital Panels are
assigned an individual position number (FUNCTION 8) AFTER
Downloading system data.
Non Alpha
A
AB
ABC
ABCD
ABCDE
ABCDEF
Concierge with
Panel & Lobby
Camera
without Door
Open Tone
006
014
022
030
038
046
054
Concierge with
Panel & Lobby
Camera
with Door
Open Tone
070
078
086
094
102
110
118
Non Concierge
Panel & Lobby
Camera
without Door
Open Tone
007
015
023
031
039
047
055
Non Concierge
Panel & Lobby
Camera
with Door
Open Tone
071
079
087
095
103
111
119
Digital Video
Revision 1.08 Date: 05/01/2009

- 15 -
Digital Video
Installation Manual
Digital Entrance Panel Programming Instructions cont...
Main and Riser/Landing Controllers
1) Program the Main and Riser/Controllers to the Controller Programming Sheet..
2) Set all Controllers to their specified Riser/Landing positions for a Digital System.
(See Controllers and Flat Location form).
An existing or previously used Digital Panel at switch on having pressed the PROG button
should read 01.01 and will then alternate between 01.01 and a clear display or the previously
entered flat number.
To Start Programming
1) Press the PROG button. The Panel display should now read 01.01, Blank or Digits.
2) Press CANCEL to clear the previously programmed flat number(s) if required.
3) Enter flat number required and press CALL to store the flat number you have selected.
4) The display should now read 01.02.
5) If a new Digital Panel continue with item 3 until all required flats are programmed.
6) If you are programming an existing or previously used Digital Panel continue with
items 2 & 3 until all required flats are programmed.
Finally press the PROG button to exit the programming mode.
Note 1:
When there is a need to edit or check an already programmed flat on the system
use the following procedure.
Enter Controller number i.e. 2. Enter Line Output number i.e. 03 and press PROG.
To edit a flat number press CANCEL enter new flat number and press CALL to store.
Finally press PROG to exit edit mode.
The Edit/Check flat number operation is now complete.
Note 2:
01.01 relates to 01. Controller position and .01 Telephone/Monitor Line 1.
Note 3:
On initial programming if the Red Busy Indicator on the Digital Panel illuminates when a flat is
called and does not ring, either the flat has not been programmed or the Privacy is in the
ON mode.
Digital Entrance Panel Controls
button Used to put the Digital Panel in and out of programming mode.
UPLOAD button With the Primary Digital Panel programmed pressing the
UPLOAD button(s) on all Secondary Panels will make them
ready for information to be downloaded.
DOWNLOAD button Pressing the DOWNLOAD button on the Primary Digital Panel will send
program information to all prepared Secondary Digital Panels.
INTERNAL Volume Digital Panel to Telephone/Monitor volume adjustment
EXTERNAL Volume Telephone/Monitor to Digital Panel volume adjustment
Digital Entrance Panel Programming
PROG
Digital Video
Revision 1.08 Date: 05/01/2009
This manual suits for next models
1
Table of contents
Popular Intercom System manuals by other brands

urmet domus
urmet domus Miwi Matibus SE manual

Elvox
Elvox 12F3 Installation and operation manual

Aiphone
Aiphone TAR-3 Installation & operation manual

Aiphone
Aiphone LAF-3B installation manual

Bticino
Bticino Classe 300 EOS KIT User and installation manual

Aiphone
Aiphone HOME INTERCOM LAF-1B installation manual