manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Sgooway
  6. •
  7. Security System
  8. •
  9. Sgooway ZC-GSM015 User manual

Sgooway ZC-GSM015 User manual

1
MOBILE CALL
GSM Alarm System
ZC-GSM015 User’s Manual
Profile
For a better understanding of this product, please read this
user manual thoroughly before using it.
2
Function Instruction:
7 wired and 99 wireless defense zones;
LCD screen with time clock display;
Voice prompt for all operations;
3 groups of timely arm and disarm;
Can store 6 phone numbers: when alarming, system will make
alarm call to these numbers automatically;
Can store 3 SMS numbers: when alarming, system will send
alarming SMS automatically;
10-second automatic message recording;
Built-in artificial intelligent digital voice announcer;
Built-in artificial intelligent English message;
Users can make calls by using keypad on alarm panel, just like a
telephone;
One-key-control function: Out Arm, Home Arm, Remote Arm;
SOS, fire, gas, door, hall, window, balcony, and boundary places
alarm;
Real-time, delay, 24 hours, bypass defense zones programming
function;
Wireless coding: easy to add additional wireless accessories;
Remote control Arm, Disarm, Monitor, and Intercom by phone;
SMS alert for power failure or recovery;
Built-in AAA NI-HI rechargeable battery: make alarm when power
off;
Comply with CCC safety standard and GB12663-2001 national
standard.
Alarm Host Diagram
In order to make the main unit get the wireless signal well for all wireless
accessories, please put the alarm host at the central place of your defense area.
Makesureit’saway from largemetal objects and household appliances which
may cause high frequency interference, as well as barriers such as reinforced
concrete wall or fire door, etc.
3
Alarm Panel front schematic diagram:
Alarm Panel back schematic diagram:
Wired terminal block:
Z 1
Z 2
SP+
+-
SP
LB+
LB
GN D
GND
Z 3
Z 4
Z 5
Z 6
GND
Z 7
4
1 LB- Negative of two-way speaker (black cable)
2 LB+ Positive of two-way speaker (red cable)
3 GND Ground
4 Z1 Wired sensor 1: support NO and NC
5 GND Ground
6 Zone 2 Wired sensor 2: support NO and NC
7 Zone 3 Wired sensor 3: support NO and NC
8 GND Ground
9 Zone 4 Wired sensor 4: support NO and NC
10 Zone 5 Wired sensor 5: support NO and NC
11 GND Ground
12 Zone 6 Wired sensor 6: support NO and NC
13 Zone 7 Wired sensor 7: support NO and NC
14 SP- Negative of Siren (black cable)
15 SP+ Positive of Siren (red cable)
Note:
1. “LB-”and “LB+”are to connect external speaker. If you think the
internal speaker is not loud enough, please contact us for professional
speakers.
2. Connect one cable of the wired sensor to GND and the other to
“Z1/Z2/Z3.../Z7”.
3. Please pay attention to the siren connection. Do not mix the two cables
together when connecting. Otherwise,it will damage the transistor in the
main panel.
5
LCD display:
Function Settings
1. Initialization
Please insert SIM card and plug in power adaptor, and then power on the
system, all the LED lights will be on for 2 seconds and you will hear a
long beep; the system comes into initialization. After the time clock
displays on the LCD screen, the [SGM] starts flashing and the main unit
starts to detect the GSM network until a long beep. Then the [SGM]
indicator goes out indicating the system comes into disarm status.
Finally, turn on the backup battery switch.
2. Enter Settings
In the state of disarm, input 4-digit password by the keypad on the main
unit and press [#] button to confirm. You will hear a voice prompt: please
enter instruction. At the same time, [SET] indicator is on without flashing
and [0000] displays on the screen, indicating the system enters setting
status. You can perform different settings repeatedly as long as the system
keeps in setting status. The system will exit setting mode and return to
disarmstatusif you don’t pressany keypadbutton for 40 seconds.
6
Note:In setting status,press can delete the numbers input.
The system default password is [8888].
Operating method: [XXXX] [#]
Xindicates the new 4-digit password.
LCD display:
3. Exit Settings
Press [*] and [#] buttons, the main unit emits a long beep and exits
settings. The [SET] indicator goes out and the system returns to disarm
state.
Operating method: 【*】 【#】]
4. Factory Reset
In disarm status, use keypad to input [95175308246] and press [#] to
confirm, all the LED indicators will be on for 2 seconds and you will
hear a long beep. The main unit gets all its settings cleared and restores
to its factory settings successfully.
Operating method: [95175308246] + [#]
5. Coding of Remote Controller
The remote controller has to be code to the alarm host in order to
perform normally.
In setup state, use keypad to input [20], input the remote controller
number [1~8], and then press [#] to confirm. The main unit emits a long
beep and you will hear “remotecontrol coding”. The [ ] indicator is
on without flashing; press any button on the wireless remote controller,
the main unit makes a long beep and you will hear “coding completed”,
[ ] indicator goes out, indicating the remote controller succeeds in
coding.
Operating method: [20] [A] [#]
Aindicates:1~8 remote controllers number.
7
You can add maximum 8 remote controllers.
LCD display:
`
6. Delete Remote Controller
Theremotecontroller can’t control the main unit after it’sdeleted.
In setup state, use keypad to input [21], then input the remote controller
number [1-8], and then press [#] to confirm. The main unit emits a long
beep and the [Signal] indicator flickers once. You will hear a voice
prompt “delete completed”.
Operating method: [21] [A] [#]
Aindicates:1~8 remote controllers number.
Coding of Defense Zone
Wireless detectors have to be coded to the main unit in order to trigger it
alarm.
In setup state, use keypad to input [23], input the defense zone number
you want to code [01~99], and then input [#] to confirm. The main unit
emits a long beep and the corresponding defense zone is displayed on the
screen. You will hear a voice prompt “detector coding”. Then trigger a
wireless detector to emit a wireless signal; after receiving the signal, the
main unit makes a long beep, and you will hear “coding completed”, the
[ ] indicator goes out at the same time.
Operating method: [23] [XX] [#]
XX indicates: 01 ~99 defense zones number
LCD display:
8. Delete Defense Zone
The wireless detector can’t control the main unit after it’sdeleted.
In setup state, use keypad to input [24], then input the defense zone
number you want to delete [01~99], and then input [#] to confirm. The
8
main unit emits a long beep and the defense zone indicator flickers once.
You will hear a voice prompt “delete completed”.
Operating method: [24] [XX] [#]
XX indicates: 01 ~99 defense zones number
9. Change Password
1) Change Operation Password
Operation password is the password used to disarm or remote control.
In setup status, use keypad to input [30], then input the 4-digit new
password, and then press [#] to confirm. The main unit will make a long
beep and you will hear a voice prompt “settingcompleted”.
Operating method: [30] [XXXX] [#]
XXXX indicates: the new 4-digit password
For example: change the system password to 1012
Operating method: [30] [1012] [#]
LCD display:
2 ) Change Program Password
Program password is the password you should input in order to setup
the system.
In setup status, use keypad to input [31], then input the 4-digit new
password, and then press [#] to confirm. The main unit will make a long
beep and you will hear a voice prompt “settingcompleted”.
Operating method: [31] [XXXX] [#]
XXXX indicates: the new 4-digit password
For example: change the system password to 2846
Operating method: [31] [2846] [#]
LCD display:
Note:the operation password and the programming password can not be set
as the same number.
9
10. Clock Setting
In setup status, use keypad to input [32], then input the last 2 digits [AA]
of the present year, the two digits [BB] of the month, the two digits [CC]
of the date, the two digits [DD] of the hour (24-hour system), the two
digits [EE] of the minute, the two digits [FF] of the second, and finally
enter [#] to confirm. You will hear a long beep and a voice prompt
“settingcompleted”.
Operating method: [32] [AA] [BB] [CC] [DD] [EE] [FF] [#]
AA indicates: the last 2 digits of the present year
BB indicates: the 2 digits of the present month
CC indicates: the 2 digits of the present date
DD indicates: the 2 digits of the present hour
EE indicates: the 2 digits of the present minute
FF indicates: the 2 digits of the present second
For example: set the time as 15:35:40, Oct. 1st, 2009
Operating method: [32] [09] [10] [01] [15] [35] [40] [#]
11. Timing Settings
1 ) Timely Arm
In setup status, use keypad to input [33~35], then input the hour [AA] and
minute [BB] of the time you want to set to arm, and finally input [#] to
confirm. You will hear a long beep and a voice prompt “setting
completed”.
Operating method: [XX] [AA] [BB] [#]
XX indicates: the address code 33, 34, 35 of the timely arming
AA indicates: the hour of the setting time
BB indicates: the minute of the setting time
For example: set the arm time as 45’10pm
Operating method: [33] [22] [45] [#]
LCD display:
10
2 ) Timely Disarm
In setup status, use keypad to input [36~38], then input the hour [AA] and
minute [BB] of the time you want to set to disarm, and finally input [#] to
confirm. You will hear a long beep and a voice prompt “setting
completed”.
Operating method: [XX] [AA] [BB] [#]
XX indicates: the address code 36, 37, 38 of the timely disarming
AA indicates: the hour of the setting time
BB indicates: the minute of the setting time
For example: set the arm time as 55’7pm
Operating method: [33] [22] [45] [#]
LCD display:
3) Timing Control
In setup status, use keypad to input [39], then input the number indicating
turning on timely arm/ disarm [1/0], and then input [#] to confirm. You
will hear a long beep and a voice prompt “setting completed”. The factory
default is off.
Operating method: [39] [0/1] [#]
0: turn off the function of timely arm/ disarm
1: turn on the function of timely arm/ disarm
For example: turn on the function of timely arm/ disarm
Operating method: [39] [1] [#]
12. Time setting for OutArm Delay (Default: 60sec)
In setup state, input the command: 44+(XX) + #
XX indicates: the delay time of out arm: XX=01-99:1 sec to 99 sec
Note: The setting is effective only with the keypad operation.
The operation by remote controller or SMS is immediate arm without
delay.
11
13. Time Setting forAlarm Delay (Default: 40sec)
In setup state, input the command: 45+(XX) + #
XX indicates: the delay time of out arm: XX=01-99:1 sec to 99 sec
Note:The setting is effective only when a zone is set as Alarm Delay Zone
Note:Before the system enters arm or alarm status
It will emit a “Di”sound per second
14. Alarm Number Setting
In setup state, input [51] ~ [56], then input the voice alarm-receiving
number (mobile number or telephone number), and then press [#] to
confirm. The main unit will make a long beep, the [Signal] indicator will
flicker once, and you will hear “setting completed”, which indicate voice
alarm-receiving number is set successfully.
Operating method: [XX] [YY…YY] [#]
XX indicates:the 1- 6 alarming user number [51] ~ [56]
YY…YY indicates: voice alarm-receiving phone number
For example: set 13811111111 as the first voice call number
Operating method: [51] [13811111111] [#]
LCD display:
15. Delete Phone Number
In setup state, input [51] ~ [56], and then press [#] to confirm the main
unit will make a long beep and the [Signal] indicator will flicker once and
you will hear “delete completed”, which indicate the alarming user
number is deleted successfully.
Operating method: [XX] [#]
XX indicates:the 1- 6 alarming user number [51] ~ [56]
For example: Delete the third alarming user number from the system.
Operating method: [53] [#]
LCD display:
12
16. SMS Receiving Number Setting
SMS Receiving number means when system is alarming, it will only
send SMS to this mobile number. You can set maximum 3 SMS numbers.
In setup state, input [57] ~ [59], then input the SMS receiving number,
and then press [#] button to confirm. The main unit will make a beep, the
[Signal] indicator will flicker once and you will hear “setting completed”,
which indicate setup successfully.
Operating method: [XX] [YY…YY] [#]
XX indicates: address codes of message-receiving numbers from the first
group to the third group [57] ~ [59]
YY…YY indicates: the SMS receiving number
For example: setup 13822222222 as the first SMS receiving number
Operating method: [57] [138222222] [#]
17. Delete SMS Receiving Number
In setup state, use keypad to input [57] ~ [59], and then press [#] button
to confirm. The main unit will make a beep, the [Signal] indicator will
flicker once and you will hear “delete completed”, which indicate SMS
number is deleted successfully.
Operating method: [XX] [#]
XX indicates: address codes of message-receiving numbers from the first
group to the third group [57] ~ [59]
For example: delete the first SMS user number from the system
Operating method: [57] [#]
18. SMS Notification forArm/Disarm (Default: OFF)
In setup state,input the command [77] + [1/0] + [#] (1:NO, 0:OFF)
After starting this function,the system can send SMS to three SMS
receiving numbers (57-59 as mentioned above) when the system enters
arm/disarm status through wireless remote controllers or its keypad
opeation
13
19. Defense Zone Programming
If you want to change the alarm attribute of defense zone, such as turn off
the siren when system alarms, you can do it by defense zone
programming. In setup state, first input [60], then the defense zone
number [01~99], then input defense zone type [1~4], then input defense
zone location number [1~8], and then select siren on/off [0/1], at last
press [#] to confirm. You will hear the main unit emit a long beep and a
voice prompt “setting completed”.
Operating method: [60] [AA] [B] [C] [D] [#]
AA: defense zone number [01~99] means zone 1 to zone 99;
B: defense zone type
[1]: real-time defense zone [2]: 40 seconds delay defense zone
[3]: 24 hours defense zone [4]: bypass defense zone
C: defense zone location
[1] SOS Alarm [2] Fire Alarm [3] Gas Leak Alarm
[4] Door Alarm [5] Hall Alarm [6] Window Alarm
[7] Balcony Alarm [8] Boundary Alarm
D: siren ON/OFF: [0] OFF, [1] ON
For example: set defense zone 12 to be 24-hour, fire alarm and siren on
Operating method: [60] [12] [3] [2] [1] [#]
20. HomeArm Defense Zone Setting
If you want some detectors work and some do not, you can use [Home
Arm] function.
In setup state, use keypad to input [61], then choose the corresponding
defense zone number [01~99], then choose [Home Arm], and then
choose whether alarm [0/1] button, and finally press [#] to confirm. The
main unit will make a long beep and a voice prompt “setting completed”.
Operating method: [61] [XX] [A] [#]
XX indicates: [01~99] is defense zone 1 to defense zone 99
A indicates: [0] Home arm but not alarm
[1] Home arm and alarm
For example: set defense zone 11 to be Home arm and alarm
Operating method: [61] [11] [1] [#]
14
For example: set defense zone 12 as Home arm but not alarm
Operating method: [61] [12] [0] [#]
21. Voice Recording
In setup state, use keypad to input [701], and then press [#] to confirm.
The main unit will emit a beep and the [ ] indicator is on, and after
10 seconds countdown, recording starts: record at 30cm away from the
main unit with moderate tone; 10 seconds later, the main unit will make a
beep indicating the recording stops and the recorded voice will replay.
Operating method: [701] [#]
LCD display:
22. Siren Setting
In setup state, use keypad to input [75]; in the operation of arm/ disarm by
remote control, select if the siren sounds or not by [0/1] button, and then
press [#] to confirm. The main unit will emit a long beep and a voice
prompt “setting completed”.
Operating method: [75] [A] [#]
Aindicates: [0] Siren off; [1] Siren on; System default: [0] Siren off
For example: set siren on when arm/ disarm
Operating method: [75] [1] [#]
LCD display:
23. Siren Setting in “Emergency Help”mode
In setup state, use keypad to input [76], and then [1/0], finally press [#]
to confirm,The main unit will make a long beep and a voice prompt
“setting completed”.
Operating method: [76] [A] [#]
A indicates :
[0] : siren off in “Emergency Help”mode
15
[1] : siren on in “Emergency Help”mode
System default: [0] siren off
Operation Instructions
1. System status.There are 4 status as following:
1) Arm: defense zone 1~99 will alarm when detectors are triggered
2) Home Arm: in arm status, the defense zone which is set as [Home
Arm] will alarm when detectors are triggered.
3) Disarm: defense zone 1~99 will not alarm when detector triggered
(except 24 hours defense zone)
4) System setup status: In this status, all defense zones will not alarm
when detectors are triggered.
2. Remote Controller Operation
Users can use remote controller to set system as Out Arm, Home Arm,
Emergency Alarm, Real-time Disarm and etc.
Out Arm: Press button
Disarm: Press button
Home Arm: Press button
Emergency Alarm: Press button, system will alarm at once.
3. Out Arm
It means to guard all around your house while everyone is going out; all
the detectors of the host are always working; when the detector is
triggered by detecting source (anti-theft, fire prevention, gas leak, etc.),
the alarm system will sound the alarm.
Press [Out Home ] button on keypad, system will make a beep per
second and totally 60 beeps. The [OUT ARM] indicator will be on
without flashing. It means Out Arm is set successfully.
Arm Operation: Press [Out Home ] button , the system will enter arm
status 60 seconds later.
LCD display:
You can also set out arm by SMS remotely. The SMS command is :
16
Operation Password (Default: 1234) + [1]
After the setting,the main unit makes a “Di”Sound,ARM LED is on and you
will receive a SMS: System armed.
4. HomeArm
It means, for the safety, while somebody is at home, you need to enable
the peripheral door, window, balcony and boundary detectors of the alarm
system while prevent from triggering the indoor detectors, which may
cause improper warning; then, you shall select Arm at Home, let just part
of the detectors work and disable the other parts.
Main Unit Operation: Press [At Home ] button on keypad
Remote Control Operation: Press [ ] button on remote controller.
LCD display:
5. Disarm
It means to stop the alarm when the main unit sounds the alarm or make
the alarm system in the state of non-warning. After disarming, even if you
trigger the detector, the main unit would not sound alarm (excluding
24-hour defense areas).
Use keypad to input system password, then press [#] button. [Out Home]
or [At Home] lights will be off. It means set system disarm successfully.
Remote Control Operation: Press [ ] button on remote controller
Main Unit Operation: input system password + [#]
LCD display:
You can also set disarm by SMS remotely.The SMS command is: Operation
Password (Default: 1234) + [2]
After the setting , the main unit makes
17
6. AnswerAlarm Call
When the main unit sounds alarm, it will dial the preset numbers. If no
one answers the call, the system will call the next user number
automatically. The system will call each preset numbers for 3 times in
order.
If you answer the call, you will hear the pre-record voice. You can set
system via your telephone or mobile phone keypad.
If you hang-up directly without answering the call, the system will call
each preset number for 3 times circularly.
Press [*]: Read the alarm information.
Press [1]: Main unit stops alarming and Arm; it stops calling users.
Press [2]: Main unit stops alarming and Disarm; it stops calling users.
Press [3]: Siren off and monitors the scene for 30 seconds; for continued
monitoring, press [3] again to monitor for another 30
seconds.
Press [4]: Main unit starts a 30-second two-way intercom. During this
time, the main unit cannot be controlled by the mobile until
30 seconds later.
7. Remote Control
Dial the number associated to the alarm main unit by phone (mobile
phone), and after one ringing cycle, you can hear a voice prompt “Please
enter password”. If the password is right, you will here “Press 1 to arm,
Press 2 to disarm, Press 3 to Monitor, Press 4 to Intercom”. If the
password is wrong, you will hear a prompt voice “wrong password,
please re-enter”.
Press [1]: arm, if finished successfully, you will hear a voice prompt
“Systemarmed”.
Press [2]: disarm, if finished successfully, you will hear a voice prompt
“System disarmed”.
Press [3]: monitoring for 30 seconds, to continue monitoring, press [3]
again to monitor for another 30 seconds.
Press [4]: two-way intercom for 30 seconds. You can’t operate the main
unit during this time.
18
8. Emergency Help
Press [Emergency ] button on keypad, or [ ] button on remote
controller or wireless panic button, the main unit will alarm and make call
to the preset user numbers.
9. System Dialing Function
In disarm status; you can use the main unit to make any call just like a
land-line telephone. Dial telephone number on keypad, press [ ] button,
the main unit will make a beep and the [Signal] indicator will be flashing.
After the call, press [ ] button again, the main unit will be in disarm
status.
Alarming Record Checking
In disarm state, input [*0#], then the main unit will make a long beep and
enters the state of alarm record checking. After displaying the alarm and
defense zone number indicator, the LCD screen will display the exact
alarming time of this defense zone. Press 2, you can upturn to check the
previous alarming record; press 8, downturn to check; and press [*#] to
exit checking.
For example: the 51st defense zone; the 7th alarming; alarming time:
12:00, August 1st, 2008. LCE display
for one second,
and then display the alarming time:
GSM Signal Checking
Before installing the main unit, you should check the signal of the
installing place in order to ensure the unit can perform well. In setup
19
state, input [81] #, the main unit will make a long beep and display
00+XX (XX indicates the intensity of the signal). And the intensity
should be within the range of 07-31; if it’s less than 07, you should
change place.
For example: if the signal intensity is 12, it will display as:
Maintenance
10. System Checking
Although the alarm system is used everyday, periodical maintenance and
test are required to assure that it can run stably, reliably and safely.
Usually thorough test must be performed on the alarm main unit every
three months. You’d better check the detector once a month; if not
permitted by condition, you should check it at least every three months.
Check the main unit:
1. Whether it can arm/disarm normally.
2. Whether it can dial the number for alarm normally.
3. Whether it can receive wireless detectors’ signal normally
4. Whether the back-up battery can work normally.
Check the wireless detectors:
1. Trigger wireless detectors to see if system can alarm normally.
2. Check all detectors’ batteries toseeif it’sinlow voltage.
3. Check whether wireless detectors can send signal to the main unit
normally.
11. Notes:
Please do not disassemble, repair and alter the products without
permission, or it may cause accidents and faults.
Do not drop this product on the ground or on hard objects, as it may lead
to massive impact to cause faults and damages.
20
Technical Parameters
List 1:
Input Voltage DC12V/1A
Standby Current <55mA
Alarming Current <450mA
Wireless Frequency 433/315MHz, 2262/4.7MΩ
GSM Frequency 900/ 1800/ 1900MHz
Back-up Battery NI-HI AAA*6 DC7.2V
Siren Volume 110dB
List 2:
Defense Zone Arm Home
Arm Type Alarm
Information Siren
Zone 1 effective invalid real-time Door alarm yes
Zone 2 effective invalid real-time Hall alarm yes
Zone 3 effective effective real-time Window alarm yes
Zone 4 effective effective real-time Balcony alarm yes
Zone 5 effective effective 24 hours Fire alarm yes
Zone 6 effective effective 24 hours Gas alarm yes
Emergency
button
effective effective 24 hours Emergency alarm no
Zone 7-99 effective invalid real-time Emergency alarm yes
Wired defense
zone(96-99)
effective invalid real-time Emergency alarm yes
Operation Password 8888 Remote control On
Remote control Password 1234 Siren Off
Siren sound time 180 sec. Home Appliance Optional

Popular Security System manuals by other brands

NETGEAR Arlo user manual

NETGEAR

NETGEAR Arlo user manual

Velleman DWH G955 Installation and operation instruction manual

Velleman

Velleman DWH G955 Installation and operation instruction manual

NAPCO PRO410 operating instructions

NAPCO

NAPCO PRO410 operating instructions

Pioneer HD-V9000 Service manual

Pioneer

Pioneer HD-V9000 Service manual

Honeywell Ademco VISTA-20P quick start guide

Honeywell

Honeywell Ademco VISTA-20P quick start guide

Concept Smoke Screen Sentinel S70 Installation and operation manual

Concept Smoke Screen

Concept Smoke Screen Sentinel S70 Installation and operation manual

Fidelis XPS user guide

Fidelis

Fidelis XPS user guide

Rokonet ORBiT-14 user manual

Rokonet

Rokonet ORBiT-14 user manual

ADEMCO LYNXR quick start guide

ADEMCO

ADEMCO LYNXR quick start guide

Pyle plcmtr82wir user manual

Pyle

Pyle plcmtr82wir user manual

FBII XL-2 owner's manual

FBII

FBII XL-2 owner's manual

Gira Alarm Connect quick start guide

Gira

Gira Alarm Connect quick start guide

Smarti SmartHome Installation and operating instructions

Smarti

Smarti SmartHome Installation and operating instructions

i3 International 6E32 Series Quick connection guide

i3 International

i3 International 6E32 Series Quick connection guide

SECO-LARM SLI 820R owner's manual

SECO-LARM

SECO-LARM SLI 820R owner's manual

Bosch PVA-1EB quick start guide

Bosch

Bosch PVA-1EB quick start guide

Salus CSB600 installation manual

Salus

Salus CSB600 installation manual

Stahl 8491/2 Series operating instructions

Stahl

Stahl 8491/2 Series operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.