Model3012, 10/100/1000Mbps adaptive Gigabit Ethernet fiber
converter uses the switching technology to conduct media
conversion, which meets the standards of IEEE802.3, IEEE802.3u,
IEEE802.3z and IEEE802.3ab. This kind of media converter
supports two types of media network connections: 10Base-
T/100Base-TX/1000Base-T and 1000Base-SX/LX. Model3012 can
conduct mutual conversion between 10Base-T/100Base-
TX/1000Base-T twisted pair electrical signals and 1000Base-
SX/LX optical signals. This media converter extends the
transmission distance of a network from 100m over copper wires to
20 Km. This media converter supports transmission in dual-fiber
multi-mode, dual-fiber single-mode , SC/ST/FC style fiber-optic
connections.
Packing
Packing
Packing
Packing
L
L
L
L
ist
ist
ist
ist
:
:
:
:
Model 3012 is shipped with following items.
1. Model3012 ×1
2. 5VDC power adapter ×1(Media converter/5VDC)
3. User manual ×1
F
F
F
F
eatures:
eatures:
eatures:
eatures:
1. Accord to IEEE802. 1 10Base-T , IEEE802.3 u 100Base-TX, IEEE
802.3ab 1000Base-TX , IEEE802.3 z 100 0 Base- SX/LX
2. MDI/MDI-X auto negotiation, 10M/100 M/1000 M auto
negotiation
3. Supports full /half duplex, Point-to-point transparent transfer
4. Power External input
5. Plug-and-play, easy to installation
6. Can insert to 2U 19", 14 slots Rack mount(power external)

Your
Serial and Data Communications Expert
Shen zhen 3onedata Technology Co.,Ltd
P
P
P
P
inout
inout
inout
inout
Configuration:
Configuration:
Configuration:
Configuration:
Power
Power
Power
Power
Model3012 adopt the power supply input is 5VDC external.
Ethernet(RJ45),Optical
Ethernet(RJ45),Optical
Ethernet(RJ45),Optical
Ethernet(RJ45),Optical
fiber
fiber
fiber
fiber
interface
interface
interface
interface
Optical
Optical
Optical
Optical
fiber
fiber
fiber
fiber
interface:
interface:
interface:
interface:
Optic fib er interface need use in pairs, OUT port is fiber send side
,
connect another long-range light of interface fiber receive end IN;
IN port is fiber receive side
,
connect long-range same fiber send side :
Optic fib er s spent both ends mark the label (the following picture
show: A-A, B-B, can also mark another: A1-A2, B1-B2), in order to
use.
NOTE:
NOTE:
NOTE:
NOTE:
SC, ST or FC, for optic fiber interface, SM is look the same
to MM for form. For example,Model 3012 SM/SC,the optic fiber
interface(SC) is look the same to Mode 3012 MM/SC.

Your
Serial and Data Communications Expert
Shen zhen 3onedata Technology Co.,Ltd
Ethernet
Ethernet
Ethernet
Ethernet
interface:
interface:
interface:
interface:
Ethernet( RJ45 ) interface supports MDI/MDI-X auto negotiation,
can use straight- through cable connect PC or server, use across-
over connect cable Switch or HUB.
MDI: PIN 1, 2, 3, 6 connects opposite.
MID-X: 1 → 3
,
2 → 6
,
3 → 1
,
6 → 2
MDI/MDI-X 10Base-T/100Base-TX P IN define as follow:
Note
:
“TX ±” Transfer data ±
,
“RX ±” Receive data ±
,
“—” None 。
MDI:
MDI:
MDI:
MDI:
MDI-X:
MDI-X:
MDI-X:
MDI-X:
PIN
MDI
MDI-X
1
TX+
RX+
2
TX-
RX-
3
RX+
TX+
6
RX-
TX-
4、5、7、8
—
—
1
8
RJ
45
TX
+
TX
-
TX
-
RX
+
RX
+
RX
-
RX
-
TX
+
2
3
6
1
2
3
6
1
1
8
RJ
45
TX
+
TX
-
TX
-
RX
+
RX
+
RX
-
RX
-
TX
+
2
3
6
1
6
1
2
3
(
TX
- )
(
RX
+)
(
RX
- )
(
TX
+)
(
TX
+)
(
TX
- )
(
RX
+)
(
RX
- )
1 8

Your
Serial and Data Communications Expert
Shen zhen 3onedata Technology Co.,Ltd
LED
LED
LED
LED
indications:
indications:
indications:
indications:
Specifications:
Specifications:
Specifications:
Specifications:
Standards : comply with IEEE802. 1 10Base-T
,
IEEE802.3 u
100Base-TX, IEEE 802.3ab 1000Base-TX , IEEE802.3 z
100 0 Base- SX/LX standards
RJ45 port rate: 10/100/1000Mbps auto negotiation
Optic port rate: 1000Mbps
Transfer distance: RJ45port: 100m
Fiber optic:20,40,60,80,120km(SM),
220m,550m(MM) optional
RJ45 port cable: UTP 5E
Fiber connector: 2 ×SC, 2 ×
ST,
2×FC optional
Fiber optic cables: Single Mode:8.3/125,8.7/125,9/125 or 10/125
LED
STATE
INDICATION
PWR
PWR
PWR
PWR
(Power)
OFF
Power Off
BRIGHT
Power On
FX
FX
FX
FX
(Fiber Link Port)
OFF
Ethernet is not
Connected
BRIGHT
Ethernet is Connected
100M
100M
100M
100M
(10/100M)
OFF
10M Ethernet
BRIGHT
100M Ethernet
1000M
1000M
1000M
1000M
OFF
Not 1000M Ethernet
BRIGHT
1000M Ethernet
DUP
DUP
DUP
DUP
(Duplex Mode)
OFF
Half Duplex
FLASHING
Full Duplex
TP-
TP-
TP-
TP-
TX
TX
TX
TX
(Ethernet Port)
OFF
Ethernet is not
Connected
FLASHING
Transmitting or
Receiving Data
BRIGHT
Ethernet is Connected

Your
Serial and Data Communications Expert
Shen zhen 3onedata Technology Co.,Ltd
um
Muti-Mode: 62.5/125, 50/125 um
Wavelength:850nm,1310nm,1550nm
Power supply: External 5VDC input
Dimensions: 94.0mm ×71.0mm ×26.0mm
Installation: support DIN-Rail installation
Operating temp:-10 °
C
to 65 ° C
Storage temperature: -20 to 70 ° C
Operating humidity : 5% to 95% (no condensation)
Warranty: 5 years
Approvals: FCC,CE, RoHS approvals
Applications
Applications
Applications
Applications
:
:
:
:
Extending
Extending
Extending
Extending
10/100/100M
10/100/100M
10/100/100M
10/100/100M
Ethernet
Ethernet
Ethernet
Ethernet
data
data
data
data
distance
distance
distance
distance
Installation
Installation
Installation
Installation
:
:
:
:
Model3012 provides DIN-rail and wall mounting two types of
installation.
Wall
Wall
Wall
Wall
mounting
mounting
mounting
mounting
installation
installation
installation
installation

Your
Serial and Data Communications Expert
Shen zhen 3onedata Technology Co.,Ltd
DIN-Rail
DIN-Rail
DIN-Rail
DIN-Rail
Installation
Installation
Installation
Installation
Troubleshooting
Troubleshooting
Troubleshooting
Troubleshooting
instructions:
instructions:
instructions:
instructions:
1. Make sure the power is connected and turned on.
2. Make sure the converter Ethernet and fiber optic cables are
connected properly.
3. Check the connections according to the connection diagram.
4. Check the LED Indication status and identify possible problems
from the Indication LED table above.
Note:
Note:
Note:
Note:
1. M ed ia C o n v e r t e r is a s e n s i t i v e e l e c t r on i c i t e m , p l e a s e d o
h a n d l e w i t h e x t r a c a r e o n d e l i v e r y , s h i ft i n g a n d h u m i d i t y .
2. T h is u n i t w i l l b e w a rr a n t y f o r 5 y e a r s .
3. W h ene v e r t he r e is a p r ob l e m r e g a r d i n g t h e q u a l i t y i ss u e w i t h i n
t h e w a rr a n t y pe r i o d , w e w i l l t a k e t h e r e s p on s i b i l i t y t o r e p a i r w i t h
f r e e .
4. A ft e r t h e w a rr an t y p e r i o d , w e w i l l c h a r g e a c c o r d i ng l y
d e pend i n g o n t h e f a u l t o r d a m a g e .
5. W h ene v e r t h e r e is a f au l t , y o u c a n c o n t a c t o u r t e c h n i c a l
s u p p o r t a f t e r y o u i d e n t i f y t h e p r o b l e m a n d t h e a l a r m .

Your
Serial and Data Communications Expert
Shen zhen 3onedata Technology Co.,Ltd
Common
Common
Common
Common
Problems
Problems
Problems
Problems
:
:
:
:
1.
1.
1.
1.
PWR
PWR
PWR
PWR
power
power
power
power
supply
supply
supply
supply
indicator
indicator
indicator
indicator
lamp
lamp
lamp
lamp
not
not
not
not
lighting
lighting
lighting
lighting
Cause:
Cause:
Cause:
Cause:
1. Power supply not properly connected
2. Protector tube damaged
3. P ower input tie-line in reverse connection
4. Internal power supply circuit with failure
Solution
Solution
Solution
Solution
:
:
:
:
1. Check power switch and jack
2. Replace protector tube
3. Correct power supply line connection
4. Returned to the manufacturer for repair.
2
2
2
2
.
.
.
.
FX(Fiber
FX(Fiber
FX(Fiber
FX(Fiber
Link
Link
Link
Link
Port)
Port)
Port)
Port)
indicator
indicator
indicator
indicator
lamp
lamp
lamp
lamp
not
not
not
not
lighting
lighting
lighting
lighting
Cause:
Cause:
Cause:
Cause:
Optic fiber port link is fault.
Solution:
Solution:
Solution:
Solution:
1. Check fiber optic is link or not.
2. Check fiber optic loss is high.
3. Clean the connector of optic interface.
4. Insert the well connector in place.
5. Returned to the manufacturer for repair.
3
3
3
3
.
.
.
.
TP-T
TP-T
TP-T
TP-T
X(
X(
X(
X(
Ethernet
Ethernet
Ethernet
Ethernet
Port)
Port)
Port)
Port)
indicator
indicator
indicator
indicator
lamp
lamp
lamp
lamp
not
not
not
not
lighting
lighting
lighting
lighting
Cause:
Cause:
Cause:
Cause:
Ethernet port link is fault.
Solution:
Solution:
Solution:
Solution:
1. Check Ethernet(RJ45) line is link or not.
2. Check Ethernet(RJ45) port is loose.
3. Check the rate of selected media converter
4. Check the rate of Network.
5. Returned to the manufacturer for repair.
4
4
4
4
.
.
.
.
Network
Network
Network
Network
packet
packet
packet
packet
loss
loss
loss
loss
Solution:
Solution:
Solution:
Solution:
1. Check Ethernet rate or full/half duplex is matched or not.
2. Ethernet(RJ45) port is loose contact, or optic port is loose
contact and soiled .
3. Ethernet cable not comply with Ethernet standard.

Your
Serial and Data Communications Expert
Shen zhen 3onedata Technology Co.,Ltd
Certifications:
Certifications:
Certifications:
Certifications:
Shenzhen
Shenzhen
Shenzhen
Shenzhen
3onedata
3onedata
3onedata
3onedata
Technology
Technology
Technology
Technology
Co.,Ltd
Co.,Ltd
Co.,Ltd
Co.,Ltd
Tel: +86-755-26702688 Fax: +86-755-26703485
www.3onedata.com
Table of contents