Programming remotes in
1. Default the unit before you begin a new installation. This erases all previously programmed remotes.
2. Press the LEARN switch once to step to relay 1. (1 x beep sounds)
3. Press the button on the remote control a few times to learn in to the RX4-500 (2x beeps sound)
4. Continue to learn in any additional remote controls until all the remotes are programmed in.
5. Press the LEARN switch again to step to relay 2. (1x beep sounds)
6. Repeat Step 3; 4 & 5 until all the remotes are programmed in to each respective relay.
7. Once Relay 4 is programmed, press the LEARN switch once more to step past relay 4 and exit out
of learn mode. (1 x long beep sounds)
Note: The unit can be programmed with up to 80 remotes. When the memory limit has reached its limit the
RX1-500 will auto exit out of program mode. The unit auto exits out of program mode if nothing is received after
10 -20 seconds.
Code-Hopping Encryption
1 x Relay output
Normally Open / Closed
Weather-proof ABS housing
Frequency stability controlled +/- 75KHz
Order Codes:
This product is approved for use in residential, commercial andlight
Industrial environment and complies with the essential protection
requirements of the R&TTE Directive 1999/EC on the
approximation of the laws of the Member states relating to
electromagnetic compatibility and radio spectrum.
Certifications:
ETSI EN300 220-V2.4.1
ETSI EN301-489-3 V1.4.1
ETSI EN301-489-1 V1.9.2
IEC 60950-1:2005 + A1:2009
Model No: RX1-500
1 Channel Receiver : 500m Code Hopping
Approvals: * (pending)
Installation Instructions - For Service Persons Only
III
Model:
Encryption type:
Transmission frequency:
Transmission method:
Modulation
Transmission range:
Memory capacity:
Voltage range:
Standby current consumption:
Current consumption all on:
Operating Temperature:
Dimension (lxbxh)
Gross weight:
RX1-500
Code hopping
403MHz (local) 433MHz (export)
OOK
AM
500m “Line of sight”
80 remotes
10V to 16VDC
+/-22mA 10%
+/-126mA 10%
-3°C to 49°C
145 x 66 x 40mm
135g
Technical Specifications:
Features:
For more info visit our web site: www.sherlotronics.com
1 Channel Receiver : 500m Code-hopping RX1-500
English
RX1 - 5 0 0
Warranty
This product is sold subject to our standard warranty conditions and is warrantied against defects in workmanship
for a period of two years.
Customer Support line: +2711 462 5101 E-mail: [email protected]
LEARN Press and hold for more than
10 Seconds. When the beeping
stops the unit is defaulted.
Wait a few seconds until it re-boots.
Note: Please default the unit first before installation.
This will erase any previously programmed factory
test remotes from the memory.
Defaulting the RX4-500
Relay time jumper settings
Programming the ON/OFF function
1. Default the unit before you begin a new installation. This erases all previously programmed remotes.
2. Select the 1 sec & 3 sec relay time jumpers respectively.
3. Press the LEARN switch once to step to relay 1 (ON command) (1 x beep sounds)
4. Press the button on the remote control for the ON command. (2 x short beeps sound)
5. Press the LEARN switch again to advance to the OFF command. (2 x beep sounds)
6. Press the button on the remote control for the OFF command. (2 x short beeps sound)
7. Press the LEARN switch again to advance to the next relay channel.
8. Repeat Step 3 - 6 until all the remotes are programmed in to each respective relay.
7. Once Relay 4 is programmed, press the LEARN switch once more to step past relay 4 and exit out
of learn mode. (1 x long beep sounds)
3 Seconds
Gate &
garage door
automation
Panic
on alarm
panel
Maglock
release /
beam bypass
Arming &
Disarming
alarm panels
1 Second Latch/un-Latch On / Off
Code 1 = ON
Code 2 = OFF
60 Seconds
Siren output
or beam
bypass
1sec
3sec
Latch
1min
3min
On/Off
1sec
3sec
Latch
1min
3min
On/Off
1sec
3sec
Latch
1min
3min
On/Off
3 Min
1sec
3sec
Latch
1min
3min
On/Off
1sec
3sec
Latch
1min
3min
On/Off
1sec
3sec
Latch
1min
3min
On/Off
Erasing individual remotes
1. Link the ERASE jumper
2. Press the LEARN switch
3. Press the remote to be erased
4. Repeat step 2 & 3 for each
remote to be erased.
5. Remove ERASE jumper when
done Press the button
to be erased
Repeat for each remote
to be erased.
You must erase
one remote
at a time.
20 beeps
LEARN
ERASE
Link On
Mag Lock
+
-
For more info visit our web site: www.sherlotronics.com
Opening the unit Wiring diagram
The plastic housing is splash proof, and may be mounted externally if
required. The unit should be mounted vertically for best performance.
Ensure that you do not mount the unit close to electric fence cables or
energizers, as these products produce extreme levels of interference
and may reduce the performance of the product. If mounting indoors
try and centralise the unit, and keep it at least 3 metres away from
armed response company’s alarm radio transmitters.
We recommend the unit to be mounted more than 3 metres above the
floor height just above the trap door. For large properties that require
exceptional range, mount the unit externally.
Always conduct a signal range test before you hand over the product
to the client, ensuring that the system works reliably. You may need to
move the unit if you encounter dead spots. In rare cases you may
need to install a booster repeater unit for coverage around large multi
levelled sites.
Remove the Aerial and make sure the screw on the bottom side is removed.
Carefully lift the lid up from the back end and unclip the top.
Screw hole
Mounting advice
A
B3m
For more info visit our web site: www.sherlotronics.com
Relay time
jumpers
Terminal blocks
Status
LED
LEARN
switch
Relay
output
Aerial
Typical gate motor wiring Typical alarm panel wiring
D5
Typical mag lock Typical panic to radio transmitter
Safe Common
Aux 12V Out
Trg
Ped
Com
FRX
Aux
Status
Com
Motor
Motor
12V -
12V +
Aux IO
Lck/Stp
Close
Open
Light
Light
+-
12V DC
Power- supply
YEL
GRN
Z1
BLK
AUX -
RED
AC
AC
AUX +
BELL+
BELL-
COM
Z2
COM
Z3
COM
Z4
COM
Z5
Z6
Z7
Z8
Positive trip
Panic
ERASE
switch

Other manuals for RX4-500

1

This manual suits for next models

1

Other Sherlotronics Receiver manuals

Sherlotronics RX1-150 User manual

Sherlotronics

Sherlotronics RX1-150 User manual

Sherlotronics COMPLEX_RX_V3 User manual

Sherlotronics

Sherlotronics COMPLEX_RX_V3 User manual

Sherlotronics RX4-500 User manual

Sherlotronics

Sherlotronics RX4-500 User manual

Popular Receiver manuals by other brands

Pioneer VSX-924-K quick start guide

Pioneer

Pioneer VSX-924-K quick start guide

NOVAK NER 2S manual

NOVAK

NOVAK NER 2S manual

LENCO DR-439 user manual

LENCO

LENCO DR-439 user manual

JVC KD-AV300 instruction manual

JVC

JVC KD-AV300 instruction manual

Boss Audio Systems BV9364B user manual

Boss Audio Systems

Boss Audio Systems BV9364B user manual

Denon AVR-X7200W owner's manual

Denon

Denon AVR-X7200W owner's manual

Wildlife Materials International TRX-1000S quick start guide

Wildlife Materials International

Wildlife Materials International TRX-1000S quick start guide

Kenwood KRF-V9993D How to operate

Kenwood

Kenwood KRF-V9993D How to operate

LG MDD64-A0U owner's manual

LG

LG MDD64-A0U owner's manual

Icom IC-RX7 instruction manual

Icom

Icom IC-RX7 instruction manual

Integra DTR-5.1 instruction manual

Integra

Integra DTR-5.1 instruction manual

Jasmine Jasmine BL-I user manual

Jasmine

Jasmine Jasmine BL-I user manual

Onkyo TXSR574 - AV Receiver user guide

Onkyo

Onkyo TXSR574 - AV Receiver user guide

Televes 237520 manual

Televes

Televes 237520 manual

Harman Kardon AVR 365 Service manual

Harman Kardon

Harman Kardon AVR 365 Service manual

Abocom VM311R product manual

Abocom

Abocom VM311R product manual

WODASIGN WodaPlug WP-A001E Easy start

WODASIGN

WODASIGN WodaPlug WP-A001E Easy start

RODE Microphones Wireless PRO quick start guide

RODE Microphones

RODE Microphones Wireless PRO quick start guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.