TESTING:
The light source contained in this luminaire shall only be replaced by the manufacturer or his service agent
or a similar qualified person.
1. Switch off the electricity at the mains.
2. Remove the diffuser.
3. Remove the screws on the gear tray, and open the fitting
4. Unplug the battery lead from the main board.
5. Unplug the LED lead from the PCB board.
6. Unplug the LED PCB from the gear tray.
7. Change the LED Module based on the module name on module PCB
Led replacement
This marking indicates that this product should not be disposed with other household wastes
throughout the EU. To prevent possible harm to the environment or human health from uncon-
trolled waste disposal, recycle it responsibly to promote the sustainable reuse of material resourc-
es. To return your used device, please use the return and collection systems or contact the retailer
where the product was purchased. They can take this product for environmental safe recycling.
Installation and maintenance Record:
Installer
Installation test duration & Date
Installation Type
Month
1 Short
Signed Date Date Date Date DateSigned Signed Signed Signed
Short
Short
Short
Short
Short
1 Hr.
1 Hr.
3Hr.
Short
Short
Short
Short
2
3
4
5
6
7
8
9
10
11
12
Test 1 Year
st 2 Year
st 3 Year
st 4 Year
st 5 Year
st
43
The emergency lighting must be inspected and tested regularly in accordance with local Codes of practice,
Note: tests should be carried out during day time for safety reasons.
The testing should be done by a qualified person. in an dry environment.
Move the plastic diffuser, press the test button to simulate failure of mains power, the Emergency light should
be on and driven by battery.
The minimum recommended test schedule is as follows: Charge the battery for 36 hours after installation to
ensure the battery is full and then observe if the light can discharge for 3 hours.
1. Daily check that charge indicator LED is working.
2. Monthly interrupt power for a short period to check LED lights.
3. Semiannually check 1 hour duration.
4. At the end of year and subsequent year. Check 3 hour duration: batteries must be replaced when they can
no longer support 3 hour operation.
5. Complete record sheet on installation and retain file.
6. Update file with ongoing test records for inspection by fire officer or other daily authorized person.
0
30
60
90
120
150
-/+180
-150
-120
-90
-60
-30
C0/180,117.4°
UNIT:cd
C90/270,96.9°
0.0
15.0
30.0
45.0
60.0
75.0
MH(m)
10
14
18
22
26
30
34
38
42
46
50
0.0 18.5 37.0
S(m)
0.3600
0.3000
0.2400
0.1800
0.1200
0.0600
0.0480
0.0300
0.0240
0.0180
LUMINOUS INTENSITY DISTRIBUTION DIAGRAM CO PLANE ISOLUX DIAGRAM (UNIT:1x)
AVERAGE BEAM ANGLE (50%): 107.1 DEG
STEML-U9