SHORE TEL ShoreGear 220T1A User manual

Introduction
About The ShoreGear 220T1A
The ShoreGear 220T1A Voice Switch connects internal extensions or IP phones to a
central ofce (CO) digital trunk line.
The switch provides connectivity through:
• Two RJ-45 LAN connectors
• One RJ-45 T1 port for connecting the switch to a telephone company line
• One RJ-45 T1 monitor port for connecting test equipment
• One RJ-21X port (male) for connecting the switch to a telephone company punch-
down block, patch panel, or 12-port harmonica connector
• One DB-9 (female), RS-232C maintenance port (19200 bps, 8 bits, no parity, 1 stop
bit, no handshake) for serial communications
• One audio input port (3.5 mm stereo) for connecting to a music-on-hold source
• One audio output port (3.5 mm stereo) for connecting to a corporate paging system or
night bell
The ShoreGear 220T1A Voice Switch package contains:
• ShoreGear 220T1A Voice Switch
• Power cord
• Stick-on feet for surface installation
• Mounting Ears – attachable installation brackets
• Cable Retainer for the Telco cable (metal bracket with a Velcro strap)
Installation and Servicing Connections
Mounting the ShoreGear Voice Switch on a Flat Surface
If you plan to mount the switch on a at surface, rst attach the provided rubber feet
to the bottom corners of the device. (You can stack up to three switches in a surface
installation.)
Installing the ShoreGear 220T1A in a 19-inch Rack
The SG-220T1A is placed in a 19-inch rack only by mounting a ShoreGear Dual Tray into
the rack, then installing the SG-220T1A into the Tray. You can install the SG-220T1A on
the left or right side of the tray.
Refer to the Quick Install Guide for the ShoreGear Dual Tray for Tray installation
instructions and information on using the tray.
Installation Location Requirements
To ensure optimum operating conditions for the SG-220T1A voice switch, verify the
operating environment is adequately ventilated, free of gas or airborne particles, and
isolated from electrical noise.
Installation Equipment
To install the switch, you need the following equipment:
• AC surge protector for the power connection
• RJ-45 cables for connecting the switch to the local area network and telco lines
• Music-on-hold source with a standard mini-headphone Y-adapter (optional)
• Permanent earthing connector for grounding the device
• RJ-21 telephone cable (female on end connected to ShoreGear voice switch) for analog
port connections
• RJ-21 to RJ-11 patch panel for connecting telephones and trunk lines
• #1 Phillips screwdriver
After setting up the network connections and conguring the ShoreGear
220T1A Voice Switch for operations, you can connect your T1 line to
the switch.
Use an RJ-45 T1 cable to connect your T1 line to the Telco port.
Connecting a T1 Line
Powering on the ShoreGear Voice Switch
After connecting the switch to the network, power on the device by connecting it to an
AC power source.
1. Plug an AC surge protector (not provided) into a grounded AC power source.
2. Plug one end of the provided power cord into the receptacle on the back of the switch,
then plug the other end into the AC surge protector.
The power LED ashes momentarily, and remains lit.
• If LED is not lit, verify the power cord is plugged into the switch and power source.
• If the LED continues ashing, there is an internal error. Unplug the switch to power it
off, then power it back on. Refer to the “Conguring Switches” chapter in the ShoreTel
Administration Guide for information on ash patterns, or contact the ShoreTel
Support Services at http://www.shoretel.com.
The LAN ports auto-sense the network transport rate. When the network connection is
established, the network LED indicates a transport rate of 10 Mbps or 100 Mbps, and
whether the switch is receiving and transmitting data.
Default
Switch
Audio Output Port
(night bell)
Power
LED
Network
LEDs
LAN 2
Connector
RS-232C
Maintentance
Port
Status
LED
Audio Input Port
(music on hold)
Network
LEDs
T1 LEDs
T1 LEDs
LAN 1
Connector
T1 Monitor
Port
T1 Telco
Port
RJ-21X
Telco Port
Once the SG-220T1A Voice Switch is secured to a rack or surface-
mounted, you can connect it to the data network. Use an RJ-45 Ethernet
cable to connect one or both of the LAN ports to the network subnet.
While both ports can detect and respond to link status, the switch uses
only one LAN port at a time.
Connecting the ShoreGear Voice Switch to the Network
Optional Connections
After connecting the voice switch to the LAN, you can make optional
connections, including input from a music-on-hold source or output to
your internal paging system.
1. Connect a music-on-hold source (CD player or other audio source) to
the audio input port.
2. Connect your site’s paging system to the audio output port.
German: Das ShoreGear Voice-Schaltgerät auf einer ebenen
Oberäche montieren
Wenn Sie planen, das Gerät auf einer ebenen Oberäche zu montieren, befestigen Sie
zunächst die mitgelieferten Gummifüße an den unteren Ecken des Geräts. (Bei einer
Oberächeninstallation können Sie bis zu drei Schaltgeräte übereinander stapeln.)
Attaching an Earthing Connector
To meet electrical safety requirements for proper grounding, you must connect a
permanent earthing protector between the ShoreGear voice switch and the wiring system
ground.
1. Connect a ground wire (#14 AWG wire or larger) to the screw on the back of the unit
and to the right of the product label.
2. Connect the other end of the ground wire to the wiring system ground.
CAUTION: Always connect the permanent earthing connector before attempting to connect
the switch to a LAN segment and telecommunication lines.
German: Einen Erdungsleiter anschließen
Um den elektrischen Sicherheitsanforderungen für eine korrekte Erdung nachzukommen,
müssen Sie einen permanenten Erdungsschutz zwischen dem ShoreGear-Gerät und der
Erde des Kabelsystems installieren.
1. Schließen Sie ein Erdungskabel (Nr. 14 AWG oder größer) an die Schraube an der
Rückseite des Geräts an, die sich rechts neben dem Produktetikett bendet.
2. Schließen Sie das andere Ende des Erdungskabels an die Erde des Kabelsystems an.
VORSICHT: Schließen Sie immer zuerst den permanenten Erdungsschutz an, bevor Sie ver-
suchen, das Gerät an ein LAN-Segment und Telekommunikationsleitungen anzuschließen.
Connecting Trunk and Telephone Lines
Use the provided cable retainer to connect the voice switch to the
telephone company’s punch-down block or patch panel.
1. Use a #1 Phillips screwdriver to remove the two screws on either side
of the RJ-21X port, then place the retainer on the port and re-attach
the screws.
2. Plug the Telco cable into the port, then pull the Velcro strap tightly
around the cable connector and fasten it.
3. Connect the other end of the Telco cable to the punch-down block or
patch panel.
CAUTION: To reduce risk of re, use only No. 26 AWG or larger (e.g., 24 AWG) UL Listed
or CSA Certied Telecommunication Line Cord
VORSICHT: Um das Brandrisiko zu verringern, verwenden Sie nur Telekommunikationslei-
tungen Nr. 26 AWG oder größer (z.B. 24 AWG) mit UL- oder CSA-Zulassung
For detailed information on switch port and trunk conguration, see the “Conguring
Switches” and “Conguring Trunks” sections in the ShoreTel Administration Guide.
Servicing Procedures
WARNING: The SG-220T1A contains no internal eld serviceable parts. Return the equipment to
ShoreTel for any required service procedures.
CAUTION: Internal fuses should be serviced only by qualied ShoreTel personnel. If internal fuses
are blown and require replacement, return the SG-220T1A to ShoreTel for service.
WARTUNGSVERFAHREN
ACHTUNG: Der SG-220T1A enthält keine internen Teile, die vor Ort gewartet werden können.
Senden Sie das Gerät an ShoreTel, falls Wartungsarbeiten erforderlich sein sollten.
VORSICHT: Interne Sicherungen dürfen nur von qualizierten ShoreTel-Mitarbeitern gewartet
werden. Wenn interne Sicherungen ausgetauscht werden müssen, senden Sie den SG-220T1A zur
Wartung an ShoreTel.

Conguration & Specications Switch Status
Quick Install Guide
ShoreGear 220T1A Voice Switch
Copyright © 1998-2012 by ShoreTel Inc., Sunnyvale, California, USA. All rights reserved. Printed in the United States of America. Contents of this publication may not be reproduced or transmitted in any form or by any means,
electronic or mechanical, for any purpose, without prior written authorization of ShoreTel, Inc. ShoreTel, Inc. reserves the right to make changes without notice to the specications and materials contained herein and shall not be
responsible for any damage (including consequential) caused by reliance on the materials presented, including, but not limited to typographical, arithmetic or listing errors. ShoreTel, ShoreTel (and logo), ControlPoint, Brilliantly Simple,
Brilliantly Simple Communication, ShoreCare, ShoreGear, ShorePhone, and ShoreWare are registered trademarks of ShoreTel, Inc. in the United States and/or other countries. The ShoreTel logo is a trademark of ShoreTel, Inc. in the
United States and/or other countries. All other copyrights and trademarks herein are the property of their respective owners.
PN 850-1114-02
960 Stewart Drive Sunnyvale, California 94085
Phone: +1.408.331.3300 OR +1.800.425.9385 Fax: +1.408.331.3333 www.shoretel.com
Power LED
The power LED indicates the operating status of the switch.
Light Description
Steady The switch is powered on, and the internal software is running.
Flashing Two ashes indicates a failed internal self-test (i.e. hardware failure). Refer to “Conguring
Switches” in the ShoreTel Administration Guide for details on other ash patterns.
Off The switch is not powered on, or the software is not running.
Status LED
The status LED provides voice switch activity information.
Color Activity Description
Off No ports are assigned
Green Steady No ports are handling active calls
Green Flashing-Fast At least one port is handling an active call.
Yellow Steady No ports are handling active calls and at least one port is out of service.
Yellow Flashing-Slow The switch is not connected (or has lost connection) to a ShoreTel server.
Yellow Flashing-Fast At least one port is handling an active call and at least one port is out of
service.
Network LEDs
Each LAN connector provides two LEDs (Link/Act and 100) that indicates the activity
and communication speed of the connected network.
LED Color/State Description
Link/Act Off This switch cannot detect an Ethernet network.
Link/Act Green-Steady This switch is connected to an Ethernet network.
Link/Act Green-Flashing This switch detects network data trafc.
100 Off Network interface is operating at 10 Mbps.
100 Green Network interface is operating at 100 Mbps.
T1 LEDs
The T1 LEDs indicate line coding, network framing, and loopback status.
LED Color/State Description
Line coding Green The AMI or B8ZS line coding signal is good.
Line coding Yellow This switch is receiving bipolar violations (BPV) at one-second intervals.
Line coding Red A loss of signal (LOS) has occurred.
Line coding Off The switch has no power.
Framing Green The T1 signal is in frame (synchronized)
Framing Yellow The CO has sent a yellow alarm.
Framing Yellow-Flashing The frame-bit error rate has exceeded its limits
Framing Red T1 signal is out-of-frame (OOF) and cannot be framed to the Extended
Superframe (ESF) or D4 format.
Framing Off This switch has no power.
LC/Framing Red-Flashing Loopback is enabled. (Loopback can be set from Shoreline Director or
at the CO).
Network Conguration
Once the ShoreGear voice switch is installed and powered on, it must be congured for
network operations. A voice switch gets a network conguration by assignment from a
DHCP or BOOTP server, or directly from an administrator console (see procedure below).
For more information on setting up a switch for automatic conguration by a DHCP or
BOOTP server, see the ShoreTel Planning and Installation Guide.
Conguring the Voice Switch from a Console
1. Use a straight-through serial cable, DB9 male to DB9 female, to connect the switch to a
console PC.
2. On the PC or laptop, start a terminal emulation program and connect to the voice
switch using these serial communication settings: 19200 bps, 8 data bits, no parity,
one stop bit, no handshake.
3. At the login prompt, enter:
Login: anonymous
Password: ShoreTel
4. Choose Menu Options and follow the onscreen instructions for setting network
parameters, including IP address, subnet mask, and gateway.
Specications
Feature Specication
Dimensions 1.69 x 8.39 x 14.28 inches (43 x 213 x 378)
Weight 5.3 lb (2.4 kg)
Input voltage 100-240 VAC, 50-60 Hz
Power consumption 1A max.
Humidity 0-90% relative humidity (non-condensing)
Operating temperature 0-50˚ C
ShoreGear 220T1A Voice Switch RJ-21X Port Pinout
An RJ-21 telephone cable, wired straight through, allows the ShoreGear 220T1A Voice
Switch to connect to a standard 12-port patch panel or 12-port harmonica block. When
connecting to a 24-port patch panel, the voice switch’s six analog extension ports map to
ports 1 and 3 and ports 17, 19, 21, and 23 on the patch panel. The Power Fail Transfer
Unit provides an electrical connection between trunk channel 1 and the extension on
channel 12.
Pin No. 12345678910 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25
Port No. 12 9 10 11 12
X
Port Type T T E E E E
X
Pin No. 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50
Pin pairs Assignment
1,26 3,28 Two loop start ports (T) for trunks.
17,42 19,44 21,46 23,48 Four congurable ports (E) for telephones or DID trunks.
Other SHORE TEL Cables And Connectors manuals
Popular Cables And Connectors manuals by other brands

Splitvolt
Splitvolt Splitter Switch SPS 01-011 Quick start user guide

Burndy
Burndy Continental Industries ThermOweld CB-8 instructions

Binary
Binary B-230-HDSPLTR-1x4 installation manual

SIIG
SIIG USB-to-PS/2 Adapter Quick installation guide

Heitronic
Heitronic 21041 Installation and operating instructions

Yamaichi Electronics
Yamaichi Electronics Y-CON Cover-40-PP Assembly instructions

Lightolier
Lightolier Lytespan "T instructions

Festo
Festo NEBC-D12G4-E D12G4-ET Series Assembly instructions

TRENDnet
TRENDnet TPE-112GS datasheet

Rolls
Rolls MS20c owner's manual

Hall Research Technologies
Hall Research Technologies Mini-Cat UV4-S user manual

TE Connectivity
TE Connectivity AMPACT 83452 Series instruction sheet