Show Tec Net-8/3 User manual

Net-8/3 V1
Highlite International B.V. –Vestastraat 2 –6468 EX –Kerkrade –the Netherlands
Ordercode: 50804
MANUAL
ENGLISH

1
Ordercode: 50804
Net-8/3
Table of contents
Warning ...............................................................................................................................................................................2
Safety Instructions .........................................................................................................................................................2
Operating Determinations ..........................................................................................................................................4
Connection with the mains.........................................................................................................................................4
Return Procedure..........................................................................................................................................................5
Claims..............................................................................................................................................................................5
Description of the device.................................................................................................................................................6
Frontside..........................................................................................................................................................................6
Backside .........................................................................................................................................................................7
Installation...........................................................................................................................................................................7
Set Up and Operation .......................................................................................................................................................7
Control Modes...............................................................................................................................................................8
Setup Net-8/3 with Laptop/PC................................................................................................................................8
Setup Net-8/3 with Lighting controller ...................................................................................................................9
Fixture Linking...............................................................................................................................................................10
Data Cabling...............................................................................................................................................................10
Control Panel ...............................................................................................................................................................11
Status Menu .................................................................................................................................................................11
Main Menu Options....................................................................................................................................................12
1. Rename .................................................................................................................................................................12
2. Set DHCP ...............................................................................................................................................................12
3. Set IP Address .......................................................................................................................................................12
4. Set Netmask ..........................................................................................................................................................13
5. Set DMX Port .........................................................................................................................................................13
6. Set Device ID ........................................................................................................................................................15
7. Set LCD Backlight ................................................................................................................................................15
8. Set Display .............................................................................................................................................................15
9. User preset.............................................................................................................................................................16
10. Set Default ..........................................................................................................................................................16
11. Version .................................................................................................................................................................16
Maintenance....................................................................................................................................................................17
Replacing the Fuse.....................................................................................................................................................17
Troubleshooting ...............................................................................................................................................................17
No Light.........................................................................................................................................................................17
No Response to DMX..................................................................................................................................................17
Product Specification .....................................................................................................................................................19
Dimensions........................................................................................................................................................................20
Notes..................................................................................................................................................................................21

2
Ordercode: 50804
Net-8/3
Warning
Unpacking Instructions
Immediately upon receiving this product, carefully unpack the carton and check the contents to ensure
that all parts are present, and have been received in good condition. Notify the dealer immediately and
retain packing material for inspection if any parts appear damaged from shipping or the carton itself
shows signs of mishandling. Save the carton and all packing materials. In the event that a fixture must be
returned to the factory, it is important that the fixture be returned in the original factory box and packing.
Your shipment includes:
●Showtec Net-8/3
●Schuko to Pro Power connector power
cable (1,3m)
●User manual
Safety Instructions
Every person involved with the installation, operation and maintenance of this device has to:
●be qualified
●follow the instructions of this manual
Before your initial start-up, please make sure that there is no damage caused by transportation.
Should there be any, consult your dealer and do not use the device.
To maintain perfect condition and to ensure a safe operation, it is absolutely necessary for the user to
follow the safety instructions and warning notes written in this manual.
Please consider that damages caused by manual modifications to the device are not subject to
warranty.
This device contains no user-serviceable parts. Refer servicing to qualified technicians only.

3
Ordercode: 50804
Net-8/3
IMPORTANT:
The manufacturer will not accept liability for any resulting damages caused by the non-observance of
this manual or any unauthorized modification to the device.
Never let the power cord come into contact with other cables! Handle the power cord and all
connections with the mains with particular caution!
Never remove warning or informative labels from the unit.
Never use anything to cover the ground contact.
Never leave any cables lying around.
Do not connect this device to a dimmerpack.
Do not switch the device on and off in short intervals, as this would reduce the device’s life.
Do not touch the device’s housing bare-handed during its operation. Allow the fixture to cool for at
least 5 minutes before handling.
Do not shake the device. Avoid brute force when installing or operating the device.
Only use device indoor, avoid contact with water or other liquids.
Only operate the fixture after having checked that the housing is firmly closed and all screws are
tightly fastened.
Only operate the device after having familiarized with its functions.
Avoid flames and do not put close to flammable liquids or gases.
Always keep case closed while operating.
Always allow free air space of at least 50 cm around the unit for ventilation.
Always disconnect power from the mains, when device is not used or before cleaning! Only handle
the power cord by the plug. Never pull out the plug by tugging the power cord.
Make sure that the device is not exposed to extreme heat, moisture or dust.
Make sure that the available voltage is not higher than stated on the rear panel.
Make sure that the power cord is never crimped or damaged. Check the device and the power
cord from time to time.
If device is dropped or struck, disconnect mains power supply immediately. Have a qualified
engineer inspect for safety before operating.
If the device has been exposed to drastic temperature fluctuation (e.g. after transportation), do not
switch it on immediately. The arising condensation water might damage your device. Leave the
device switched off until it has reached room temperature.
If your Showtec device fails to work properly, discontinue use immediately. Pack the unit securely
(preferably in the original packing material), and return it to your Showtec dealer for service.
For adult use only. Device must be installed out of the reach of children. Never leave the unit running
unattended.
Never attempt to bypass the thermostatic switch or fuses.
The user is responsible for correct positioning and operating of the Net-8/3. The manufacturer will not
accept liability for damages caused by the misuse or incorrect installation of this device.
This device falls under protection class I. Therefore it is essential to connect the yellow/green
conductor to earth.
Repairs, servicing and electric connection must be carried out by a qualified technician.
WARRANTY: Till one year after date of purchase.

4
Ordercode: 50804
Net-8/3
Operating Determinations
●This device is not designed for permanent operation. Consistent operation breaks will ensure that the
device will serve you for a long time without defects.
●The maximum ambient temperature ta = 40°C must never be exceeded.
●The relative humidity must not exceed 50 % with an ambient temperature of 40° C.
●If this device is operated in any other way, than the one described in this manual, the product may
suffer damages and the warranty becomes void.
●Any other operation may lead to dangers like short-circuit, burns, electric shock, crash etc.
You endanger your own safety and the safety of others!
The Net-8/3 can be mounted in a 19-inch mounting rack.
Improper installation can cause serious damage to people and property!
Connection with the mains
Connect the device to the mains with the power-plug.
Always pay attention, that the right color cable is connected to the right place.
International
EU Cable
UK Cable
US Cable
Pin
L
BROWN
RED
YELLOW/COPPER
PHASE
N
BLUE
BLACK
SILVER
NULL
YELLOW/GREEN
GREEN
GREEN
EARTH
Make sure that the device is always properly connected to the earth!
Improper installation can cause serious injuries and/or damage of property!

5
Ordercode: 50804
Net-8/3
Return Procedure
Returned merchandise must be sent prepaid and in the original packing, call tags will not be issued.
Package must be clearly labeled with a Return Authorization Number (RMA number). Products returned
without an RMA number will be refused. Highlite will not accept the returned goods or any responsibility.
Call Highlite 0031-455667723 or mail aftersales@highlite.nl and request an RMA prior to shipping the fixture.
Be prepared to provide the model number, serial number and a brief description of the cause for the
return. Be sure to properly pack fixture, any shipping damage resulting from inadequate packaging is the
customer’s responsibility. Highlite reserves the right to use its own discretion to repair or replace
product(s). As a suggestion, proper UPS packing or double-boxing is always a safe method to use.
Note: If you are given an RMA number, please include the following information on a piece of paper
inside the box:
01) Your name
02) Your address
03) Your phone number
04) A brief description of the symptoms
Claims
The client has the obligation to check the delivered goods immediately upon delivery for any short-
comings and/or visible defects, or perform this check after our announcement that the goods are at their
disposal. Damage incurred in shipping is the responsibility of the shipper; therefore the damage must be
reported to the carrier upon receipt of merchandise.
It is the customer's responsibility to notify and submit claims with the shipper in the event that a fixture is
damaged due to shipping. Transportation damage has to be reported to us within one day after receipt
of the delivery.
Any return shipment has to be made post-paid at all times. Return shipments must be accompanied with
a letter defining the reason for return shipment. Non-prepaid return shipments will be refused, unless
otherwise agreed in writing.
Complaints against us must be made known in writing or by fax within 10 working days after receipt of the
invoice. After this period complaints will not be handled anymore.
Complaints will only then be considered if the client has so far complied with all parts of the agreement,
regardless of the agreement of which the obligation is resulting.

6
Ordercode: 50804
Net-8/3
Description of the device
Features
The Showtec Net-8/3 node is a cutting-edge network routing device which convert ArtNET to DMX512
and DMX512 to ArtNET. A maximum of 4096 channels can be transported over a single CAT5. This makes
the NET-8/3 suitable for small to large scale events. The NET-8/3 embeds a built-in network switch to be
used as a Ethernet repeater as well as 8 isolated DMX-512 universes which can be used as an input or
output. All settings can be done by the easy-to-use menu on the graphic display and buttons on the
front.
Supports both Artnet or Klingnet protocol
1 Gbps data speed
8 universes DMX input or output
High speed network in and output
Input voltage: 100-240VAC, 50/60 Hz
Power consumption: 20W max.
Fuse: F1A / 250V
Connections: 8 x 3-pin XLR OUT, 2 x RJ45, Pro Power connector
Control protocol: ArtNET, KlingNET, sACN, TCP/IPv4, DMX-512
LCD display for easy setup
IP rating: IP20
Operating temperature: 0 to +40 °C
Dimensions: 483 x 143 x 44 mm (LxWxH); 19 inch x 1HE (LxH)
Weight: 2,22 kg
Frontside
Fig. 01
01) Power LED indicator
This indicator will light up when you switch power on.
02) Link LED indicator
This indicator will light up when a network-signal is received.
03) Activity LED indicator
This indicator will light up when a DMX-signal is received.
04) LCD display
05) Menu buttons

7
Ordercode: 50804
Net-8/3
Backside
Fig. 02
06) Power switch ON/OFF
07) Pro Power connector power in
08) Fuse F1A / 250V
09) 8 x 3-pin XLR DMX OUT with LED Indicators
10) Ethernet RJ45 connecter 1 with Activity and Speed LED indicators
11) Ethernet RJ45 connecter 2 with Activity and Speed LED indicators
Installation
Remove all packing materials from the Net-8/3. Check that all foam and plastic padding is removed.
Connect all cables.
Do not supply power before the whole system is set up and connected properly.
Always disconnect from electric mains power supply before cleaning or servicing.
Damages caused by non-observance are not subject to warranty.
Set Up and Operation
Follow the directions below, as they pertain to your preferred operation mode.
Before plugging the unit in, always make sure that the power supply matches the product specification
voltage. Do not attempt to operate a 120V specification product on 230V power, or vice versa.

8
Ordercode: 50804
Net-8/3
Control Modes
Setup Net-8/3 with Laptop/PC
01) Fasten the distributor to a 19-inch rack.
02) Use a 3-pin XLR cable to connect the Net-8/3 with your fixtures by using the DMX outputs.
03) Connect the network switch with the Net-8/3 (cat 5, 6, etc cable).
04) Connect the Laptop/PC with the network switch (cat 5, 6, etc cable).
05) Supply electric power: Plug the units mains power cord into a proper electric power supply socket.
Do not supply power before the whole system is set up and connected properly.
06) Set the IP address from PC/Laptop to 2.0.0.1 and the node to 2.0.0.2.
Setup Net-8/3 with Laptop/PC
Fig. 03
Note: Link all cables before connecting electric power

9
Ordercode: 50804
Net-8/3
Setup Net-8/3 with Lighting controller
01) Fasten the distributor to a 19-inch rack.
02) Use a 3-pin XLR cable to connect the Net-8/3 with your fixtures by using the DMX outputs.
03) Connect the network switch with the Net-8/3 (cat 5, 6, etc cable).
04) Connect the lighting controller with the network switch (cat 5, 6, etc cable).
05) Supply electric power: Plug the units mains power cord into a proper electric power supply socket.
Do not supply power before the whole system is set up and connected properly.
06) Set the IP address from Console to 2.0.0.1 and the node to 2.0.0.2.
Setup Net-8/3 with Lighting controller
Fig. 04
Note: Link all cables before connecting electric power

10
Ordercode: 50804
Net-8/3
Fixture Linking
You will need a serial data link to run light shows of one or more fixtures using a DMX-512 controller or to
run synchronized shows of two or more fixtures set to a master/slave operating mode. The combined
number of channels required by all the fixtures on a serial data link determines the number of fixtures the
data link can support.
Important:
Fixtures on a serial data link must be daisy-chained in a single line. To comply with the
EIA-485 standard, no more than 30 devices should be connected on one data link.
Connecting more than 30 fixtures on one serial data link without the use of a DMX optically
isolated splitter may result in deterioration of the digital DMX signal.
Maximum recommended DMX data link distance: 100 meters
Maximum recommended number of fixtures on a DMX data link: 30 fixtures
Data Cabling
To link fixtures together you must obtain data cables. You can purchase DAP Audio certified DMX cables
directly from a dealer/distributor or construct your own cable. If you choose to create your own cable
please use data-grade cables that can carry a high quality signal and are less prone to electromagnetic
interference.
DAP Audio DMX Data Cables
•DAP Audio Basic microphone cable for allround use. bal. XLR/M 3-pin > XLR/F 3-pin. Ordercode
FL01150 (1,5 m), FL013 (3 m), FL016 (6 m), FL0110 (10 m), FL0115 (15 m), FL0120 (20 m).
•DAP Audio X-type data cable XLR/M 3-pin > XLR/F 3-pin. Ordercode FLX0175 (0,75 m),
FLX01150 (1,5 m), FLX013 (3 m), FLX016 (6 m), FLX0110 (10 m).
•DAP Audio cable for the demanding user with exceptional audio-qualities and connector made by
Neutrik®. Ordercode FL71150 (1,5 m), FL713 (3 m), FL716 (6 m), FL7110 (10 m).
•DAP Audio cable for the demanding user with exceptional audio-qualities and connector made by
Neutrik®. Ordercode FL7275 (0,75 m), FL72150 (1,5 m), FL723 (3 m), FL726 (6 m), FL7210 (10 m).
•DAP Audio 110 Ohm cable with digital signal transmission. Ordercode FL0975 (0,75 m),
FL09150 (1,5 m), FL093 (3 m), FL096 (6 m), FL0910 (10 m), FL0915 (15 m), FL0920 (20 m).
•DAP Audio DMX adapter: 3-pin/5-pin. Ordercode FLA30.

11
Ordercode: 50804
Net-8/3
Control Panel
A) LCD display
B) UP button
C) RIGHT button
D) HOME button
E) LEFT button
F) DOWN button
Fig. 05
Status Menu
In the start up mode ( ) you can see 4 different status modes on the display. It gives you
instant information on the 4 important parameters. You can scroll with the “UP/DOWN” buttons through
the 4 modes.
This status mode shows the device name
which can be changed in the main menu. For
more information see “1. Rename”on page
12.
With this mode you are able to see which port
is connected (√), not connected (X) or
disabled (-). It also shows whether a port is an
Input (-) or Output.
This status mode shows the Devices ID. It can
be set in the main menu. For more information
see “6. Set Device ID”on page 15.
This status mode shows the IP address of the
device. It can be set in the main menu (see
“3.Set IP Address” on pages 12/13) or
obtained directly from the network switch.

12
Ordercode: 50804
Net-8/3
Main Menu Options
1. Rename
2. Set DHCP
3. Set IP Address
4. Set Netmask
5. Set DMX Port
6. Set Device ID
7. Set LCD Backlight
8. Set Display
9. User Preset
10. Set Default
11. Version
Note: If no button is pressed after 10 seconds, the display will return to the start-up (Status Menu) screen.
1. Rename
01) Press the LEFT button to enter the main menu.
02) In the main menu, press the UP/DOWN buttons to select Rename and press the RIGHT button to open
the submenu. The display shows:
03) Press the UP/DOWN buttons to scroll through the letters, Cancel or Enter.
04) Press the RIGHT button to select a letter. The selected letter will be highlighted.
05) Press the UP/DOWN buttons to change the selected letter. Press the RIGHT button to confirm.
06) Press the LEFT button to go back to the previous step.
07) After editing the name, press the UP/DOWN buttons to select Cancel to exit without saving or Enter to
save the setting.
08) Press the RIGHT button to confirm the desired option.
2. Set DHCP
01) Press the LEFT button to enter the main menu.
02) In the main menu, press the UP/DOWN buttons to select Set DHCP and press the RIGHT button to
open the submenu. The display shows:
03) Press the UP/DOWN buttons to scroll through the two options Enable or Disable.
04) The selected option will be highlighted.
05) Press the RIGHT button to confirm the desired option.
06) If you select Enable, the network switch will automatically provide an IP-Address to the device.
07) If you select Disable you’ll have to set the IP address manually.
3. Set IP Address
01) Press the LEFT button to enter the main menu.
02) In the main menu, press the UP/DOWN buttons to select Set IP Address and press the RIGHT button to
open the submenu. The display shows:

13
Ordercode: 50804
Net-8/3
03) Press the UP/DOWN buttons to scroll through the numbers, Cancel or Enter.
04) Press the RIGHT button to select three numbers. The selected numbers will be highlighted.
05) Press the UP/DOWN buttons to change the numbers (0-255).
06) Press the LEFT button to go back to the previous step.
07) After editing the numbers, press the UP/DOWN buttons to select Cancel or Enter.
08) Press the RIGHT button to confirm the desired option.
4. Set Netmask
01) Press the LEFT button to enter the main menu.
02) In the main menu, press the UP/DOWN buttons to select Set Netmask and press the RIGHT button to
open the submenu. The display shows:
03) Press the UP/DOWN buttons to scroll through the three options A, Bor C.
04) The selected option will be highlighted.
05) Press the RIGHT button to confirm the desired option.
5. Set DMX Port
01) Press the LEFT button to enter the main menu.
02) In the main menu, press the UP/DOWN buttons to select Set DMX PORT and press the RIGHT button to
open the submenu. The display shows:
03) Press the UP/DOWN buttons to scroll through the ports 1-8.
04) Press the RIGHT button to select a port. The selected port will be highlighted.
05) The next display shows:
06) Press the UP/DOWN buttons to scroll through the 10 options. For more explanation see the next page.
07) Press the RIGHT button to select a option. The selected option will be highlighted.
08) Press the UP/DOWN buttons to edit the desired option and confirm with the RIGHT button.
09) Press the LEFT button to go to the previous submenu.
10) Press the LEFT button again to go back to the main menu.

14
Ordercode: 50804
Net-8/3
Explanation options DMX port
1. Disp Type
With this option you can choose between two display formats: Hexadecimal (0-F)
or Decimal (0-255).
2. DMX Status
This option is for setting the status of the port. It can be an Output, Input or Disable.
3. DMX Mode
With this option you can set the DMX mode depending on which status the port is
given.
If the port is an Input you can choose between two options: NORMAL or BACKUP.
NORMAL: The DMX port receives the DMX signal and sends it to the first
selected ArtNet universe.
BACKUP: In case of a failure, or when there are no DMX values on the first
selected ArtNet universe for more than 3 seconds, the NET 8/3 automatically
starts sending the DMX values from the backup port.
If the port is an Output you can choose between three options: SINGLE, HTP or LTP.
SINGLE: The DMX signal is sent to the DMX port from the first selected ArtNet
universe.
HTP (Highest Takes Precedence): The DMX signal is sent to the DMX port from
the merging of the 1st and 2nd ArtNet selected universe. It will compare the
values on the inputs and sends the highest value to the DMX port for each
DMX channel in both universes.
LTP (Latest Takes Precedence): The DMX signal is sent to the DMX port from the
merging of the 1st and 2nd ArtNet selected universe. It will compare the values
on the inputs and sends the last changed value to the DMX port for each
DMX channel in both universes.
Note: DMX Merging is when two or more sources of DMX are combined into one
control stream in order to control a single set of lighting fixtures.
For example: You can use two different DMX consoles to control the same lighting
fixtures. The first DMX console with 24 DMX channels on board, controls the first 24
DMX channels. The second DMX console with 24 DMX channels on board, controls
DMX channels 25 till 49.
4. Protocol
This option is for choosing a control protocol, you can choose between ArtNet,
sACN or KlingNet.
5. Framerte/fs
With this option you can set the DMX frames per second which will be sent. The
factory setting is 40 fr/second. You can change it to 10, 15, 20, 25, 30 or 35
fr/second.
6. Network
This option is for defining your network from 0-127.
7. Sub network
This option is for defining your sub network from 0-15.
8. Primary
With this option you can select the 1st Artnet Universe dedicated to this port,
from 0-15.
9. Secondary
With this option you can select the 2nd Artnet Universe dedicated to this port,
from 0-15.
This function only works if the DMX Status is set to Output and DMX Mode is HTP/LTP.
10. Resend
With this option the merged signal from the 1st and 2nd ArtNet selected universe
keeps sending data if there is no activity. You can select to which Artnet universe
(from 0-15 and DISABLED) the data has to be sent to.
This function only works if the DMX Status is set to Output and DMX Mode is HTP/LTP.

15
Ordercode: 50804
Net-8/3
6. Set Device ID
01) Press the LEFT button to enter the main menu.
02) In the main menu, press the UP/DOWN buttons to select Set Device ID and press the RIGHT button to
open the submenu. The display shows:
03) Press the UP/DOWN buttons to scroll through the number, Cancel or Enter.
04) Press the RIGHT button to select the number. The selected number will be highlighted.
05) Press the UP/DOWN buttons to change the selected number from 0-255.
06) After editing the number, press the LEFT button to go back to the previous step.
07) Press the UP/DOWN buttons to select Cancel or Enter.
08) Press the RIGHT button to confirm the desired option.
7. Set LCD Backlight
01) Press the LEFT button to enter the main menu.
02) In the main menu, press the UP/DOWN buttons to select LCD Backlight and press the RIGHT button to
open the submenu. The display shows:
03) Press the UP/DOWN buttons to choose “ON” or “OFF”.
04) The selected option will be highlighted.
05) If you choose “ON” the LCD display will always light up.
06) Choose “OFF” and the display will blackout if no button is pressed after 30 seconds.
Press one of the control panel buttons and the LCD display will light up.
07) Press the RIGHT button to confirm the desired option.
8. Set Display
01) Press the LEFT button to enter the main menu.
02) In the main menu, press the UP/DOWN buttons to select Set Display and press the RIGHT button to
open the submenu. The display shows:
03) Press the UP/DOWN buttons to choose “Normal” or “Inversion”.
04) The selected option will be highlighted.
05) If you select “Normal” the text on the LCD display is displayed normal.
06) Select “Inversion” and the text on the LCD display is displayed upside down.
07) Press the RIGHT button to confirm the desired option.

16
Ordercode: 50804
Net-8/3
9. User preset
01) Press the LEFT button to enter the main menu.
02) In the main menu, press the UP/DOWN buttons to select User preset and press the RIGHT button to
open the submenu. The display shows:
03) Press the UP/DOWN buttons to scroll through the options:
8 x INPUT: The node converts 8 x DMX512 inputs into 8 separate ArtNet universes.
DMX Split 1-7: DMX splitter with 1 input and 7 isolated DMX outputs.
DMX port 1 is input and DMX port 2-8 are outputs.
DMX Split 1-3: DMX splitter with 2x input and 3 isolated DMX outputs.
DMX port 1 is input and DMX port 2-4 are outputs.
DMX port 5 is input and DMX port 6-8 are outputs.
DMX Clone: The node converts 4 x DMX512 inputs into 4 separate ArtNet universes and
duplicates the 4 input signals to the DMX ports 5-8. A network configuration needs
to be done according to your network and your ArtNet receiver.
Isolated mode: The node receives 8 separate ArtNet unverses and sends them to the 8 DMX output
ports. A network configuration needs to be done according to your network and
your ArtNet receiver.
04) Select one of the 5 pre-programmed presets, the selected preset will be highlighted.
05) Press the RIGHT button to confirm the desired preset.
10. Set Default
01) Press the LEFT button to enter the main menu.
02) In the main menu, press the UP/DOWN buttons to select Set Default and press the RIGHT button to
open the submenu. The display shows:
03) Press the UP/DOWN buttons to select “NO” or “YES”.
04) The selected option will be highlighted.
05) If you choose “Yes”, the device will be reset and all the made settings return to the factory settings.
06) Press the RIGHT button to confirm the desired option.
11. Version
01) Press the LEFT button to enter the main menu.
02) In the main menu, press the UP/DOWN buttons to select Version and press the RIGHT button to open
the submenu. The display shows:
03) The display shows the current software version of the device.

17
Ordercode: 50804
Net-8/3
Maintenance
The operator has to make sure that safety-related and machine-technical installations are to be
inspected by an expert after every year in the course of an acceptance test.
The operator has to make sure that safety-related and machine-technical installations are to be
inspected by a skilled person once a year.
The following points have to be considered during the inspection:
01) All screws used for installing the device or parts of the device have to be tightly connected and must
not be corroded.
02) There may not be any deformations on housings, fixations and installation spots.
03) Mechanically moving parts like axles, eyes and others may not show any traces of wearing.
04) The electric power supply cables must not show any damages or material fatigue.
The Showtec Net-8/3 requires almost no maintenance. However, you should keep the unit clean.
Disconnect the mains power supply and then wipe the cover with a damp cloth. Wipe the front glass
panel clean with glass cleaner and a soft cloth. Do not use alcohol or solvents. Do not immerse in liquid.
Keep connections clean. Disconnect electric power, and then wipe the DMX and audio connections
with a damp cloth. Make sure connections are thoroughly dry before linking equipment or supplying
electric power.
Replacing the Fuse
Power surges, short-circuit or inappropriate electrical power supply may cause a fuse to burn out. If the
fuse burns out, the product will not function whatsoever. If this happens, follow the directions below to do
so.
01) Unplug the unit from electric power source.
02) Insert a flat-headed screwdriver into a slot in the fuse cover. Turn the screwdriver to the left, at the
same time gently push a bit (Turn and Push). The fuse will come out.
03) Remove the used fuse. If brown or unclear, it is burned out.
04) Insert the replacement fuse into the holder where the old fuse was. Reinsert the fuse holder. Be sure
to use a fuse of the same type and specification. See the product specification label for details.
Troubleshooting
No Light
This troubleshooting guide is meant to help solve simple problems.
If a problem occurs, carry out the steps below in sequence until a solution is found. Once the unit
operates properly, do not carry out following steps.
If the light effect does not operate properly, refer servicing to a technician.
Suspect three potential problem areas as: the power supply, the distributor or the fuse.
01) Power supply. Check if the unit is plugged into an appropriate power supply.
02) The distributor. Return the Net-8/3 to your Showtec dealer.
03) The fuse. Replace the fuse. See page 17 for replacing the fuse.
04) If all of the above appears to be O.K., plug the unit in again.
05) If you are unable to determine the cause of the problem, do not open the Net-8/3, as this may
damage the unit and the warranty will become void.
06) Return the device to your Showtec dealer.
No Response to DMX
Response: Suspect the DMX cable or connectors, a controller malfunction, a light effect DMX card
malfunction.
01) Check the DMX setting. Make sure that DMX addresses are correct.
02) Check the DMX cable: Unplug the unit; change the DMX cable; then reconnect to electrical power.
Try your DMX control again.
03) Determine whether the DMX recorder, light controller or light effect is at fault. Does the controller
operate properly with other DMX products ? If not, take the controller in for repair. If so, take the DMX
cable and/or the light effect to a qualified technician.

18
Ordercode: 50804
Net-8/3
Problem
Probable cause(s)
Solution
One or more
fixtures do not
function at all
No power to the fixture
•Check if power is switched on and
cables are plugged in
Primary fuse blown
•Replace fuse
ArtNet protocol is not active
•Configure and activate ArtNet
Fixtures reset
correctly, but all
respond
erratically or not
at all to the
controller
The controller is not connected.
•Connect controller.
3-pin XLR Out of the controller
does not match XLR Out of the first
fixture on the link (i.e. signal is
reversed)
•Install a phase reversing cable
between the controller and the
first fixture on the link
Fixtures reset
correctly, but
some respond
erratically or not
at all to the
controller
Poor data quality
•Check data quality. If much lower
than 100 percent, the problem
may be a bad data link
connection, poor quality or
broken cables, missing termination
plug, or a defective fixture
disturbing the link
Bad data link connection
•Inspect connections and cables.
Correct poor connections. Repair
or replace damaged cables.
Data link not terminated with 120
Ohm termination plug
•Insert termination plug in output
jack of the last fixture on the link
Incorrect addressing of the fixtures
•Check address setting
One of the fixtures is defective and
disturbs data transmission on the
link
•Bypass one fixture at a time until
normal operation is restored:
unplug both connectors and
connect them directly together.
•Have the defective fixture
serviced by a qualified technician
3-pin XLR Out on the fixtures does
not match (pins 2 and 3 reversed)
•Install a phase-reversing cable
between the fixtures or swap pin 2
and 3 in the fixture that behaves
erratically
LEDs damaged
•Disconnect the fixture and return it
to your dealer
The power supply settings do not
match local AC voltage and
frequency
•Disconnect fixture. Check settings
and correct if necessary

19
Ordercode: 50804
Net-8/3
Product Specification
Model:
Showtec Net-8/3
Input Voltage:
100-240 VAC, 50/60 Hz
Power consumption:
20W
Fuse:
F1A / 250V
Dimensions:
483 x 143 x 44 mm (LxWxH)
19 inch x 1HE (LxH)
Weight:
2,22 kg
Operation and Programming
Signal pin OUT:
pin 1 earth, pin 2 (-), pin 3 (+)
Setup:
LCD display for easy setup
Signal input:
3-pin XLR male, RJ45
Signal output:
3-pin XLR female, RJ45
Power connection:
Pro Power connector
Control protocol:
ArtNET, KlingNET, sACN, TCP/IPv4, DMX-512
Electro-mechanical effects
●8 universes DMX input or output
●Data signal: 1 Gbps data speed
●IP20 Rating
Max. ambient temperature ta:
40°C
Max. housing temperature tB
80°C
Minimum distance:
Minimum distance from flammable surfaces:
0,5m
Minimum distance to lighted object:
1m
Design and product specifications are subject to change without prior notice.
Website: www.Showtec.info
Email: service@highlite.nl
This manual suits for next models
1
Table of contents
Other Show Tec Network Router manuals
Popular Network Router manuals by other brands

Cisco
Cisco RV340 Series Easy setup guide

TP-Link
TP-Link TL-MR3420 Quick installation guide

Quidel
Quidel Virena WR11 installation instructions

D-Link
D-Link DES-3528 - xStack Switch - Stackable Hardware installation guide

KYLAND Technology
KYLAND Technology KIEN6000 user manual

Patton electronics
Patton electronics SmartLink 4020 Series quick start guide