Shure 92E User manual

Model 92E
Users Guide
Specications
Stylus
Stylus Grip
Color
Output (1 kHz
at 5 cm peak
recorded
velocity) †
Frequency
Response
Channel Bal-
ance
Channel
Separation
Tracking
Force*
M92E
Biradial (elliptical),
.4 x .7 mil
Red 5.0 mV 20 to
18,000 Hz
Within
2 dB
20 dB
at 1
kHz
0.75 to 1.5
grams
(1.25 grams
optimum)
N78S
78 rpm , spherical, Green 4.0 mV 20 to
17,000 Hz Mono Mono 1.5 to
3 grams
†Output voltages given for stereo cut record; for MONO cut record, output voltage
at both left channel and right channel cartridge terminals will be 71% of gure above.
*Do not exceed maximum indicated tracking force.
Optimum Load: 47,000 ohms resistance in parallel with 200 to 300 picofarads capacitance
per channel. Load resistance can be up to 70,000 ohms with almost no audible change in
frequency response. Total capacitance includes both tone arm wiring and amplier input
circuit.
Certication: Conforms to European Union directives, eligible to bear CE marking; meets
European Union EMC Immunity Requirements: EN 50 082-1, 1992.
Net Weight: 7.3 grams including standard 1/2 in. mounting adapter. Without adapter,
cartridge is compatible with pre-set P-Mount arm.
THIS CARTRIDGE FEATURES THE SHURE BIRADIAL NUDE DIAMOND TIP
Its contact area is longer and narrower
than the traditional spherical tip-groove
contact area. This results in dramatic
reduction of both harmonic distortion
and inter modulation distortion.
To clean the stylus, use a soft brush
with alcohol or an alcohol-distilled
water solution. Brush only from back to
front as shown. Commercial cleaning
solutions may cause stylus damage.
©2005, Shure Incorporated
27B2172 (Rev. 2) Printed in U.S. A.
Stylus Cleaning
A
VIEW IN DIRECTION A
27B2172_M92E.indd 1 8/22/2006 3:34:37 PM

Mounting
Tracking Force in a P-Mount Arm
After installing the cartridge, it is not usually necessary to adjust the tracking force in a
pre-set arm.
Skating Compensation (where applicable)
Set the skating compensation mechanism according to the tone arm manufacturer’s
instructions.
To Preserve Stylus Life
Protect stylus with stylus guard when dusting turntable
Regulate tone arm set-down to prevent stylus from striking edge of turntable or record.
Do not handle tone arm while record is being played. Use cuing device if available.
If manual set-down is necessary, release arm as soon as stylus engages groove
Do not activate arm without record on turntable.
Do not use damaged records.
Make certain cartridge is correctly mounted in tone arm and stylus is properly inserted in
cartridge.
Use appropriate vertical tracking force for each cartridge and stylus.
1.
2.
3.
4.
5.
6.
7.
8.
red
rouge
rot
rojo
white
blanc
blanco
weiss
green
vert
grün
verde
blue
bleu
blau
azul
RL
RG LG
A B
C
*
27B2172_M92E.indd 2 8/22/2006 3:34:38 PM

Special Note
To maintain the original performance standards of your cartridge, be certain that any
replacement stylus you buy bears the following certication on the package: “This Stereo
DYNETIC® stylus is precision manufactured by Shure Incorporated.” AVOID INFERIOR
IMITATIONS. THEY WILL SERIOUSLY DEGRADE THE PERFORMANCE OF YOUR
CARTRIDGE. ALL GENUINE “DYNETIC®” STYLI ARE MANUFACTURED BY SHURE
INCORPORATED. LOOK FOR THE NAME SHURE ON THE STYLUS GRIP.
Certication: Eligible to bear CE marking. Conforms to European EMC Directive 89/336/
EEC. Meets applicable tests and performance criteria in European Standard EN 55103
(1996) Parts 1 and 2, for residential (E1) and light industrial (E2) environments.
Warranty
Shure warrants this product to be free in normal use of any defects in workmanship and
materials for two (2) years from the date of purchase. If your Shure product fails within
this period, call 1-800-516-2525 in the United States for details on repair, replacement, or
refund. In Europe, contact Shure Incorporated Europe GMBH at +49 (7131) 7214-0 or +49
(7131) 7214-30 (service hotline) or contact your authorized Shure distributor. This warranty
does not cover abuse or misuse of the product, use contrary to Shure’s instruction, ordinary
wear and tear, an act of God or unauthorized repair.
Patent Notice
Manufactured under one or more of the following U.S. Patents: 3,463,889; 4,194,744;
4,270,758; 4,275,888; D230,741; D230,995; D235,070; D235,351; D235,352; D235,658;
D235,661; D245,022; D245,433; D252,;628; D254,004; D257,676; D255,898; D258,586;
D274,810; D274,811; D274,812; D274,813; 4,441,177; 4,473,897; 4,514,836.
FORCE D’APPUI: Avec un bras recevant directement le brochage “P-Mount” , après le montage
de la cellule, ii n’est pas nécessaire de réajuster la force d’appui d’un bras pré-réglé.
COMPENSATION DE POUSSÉE LATÉRALE: (lorsqu’elle est appliquée) : Suivez les instructions
du fabricant du bras de lecture.
CERTIFICATION: conforme aux directives de l’Union Européenne, qualiée pour les marques
CE; conforme aux exigences CEM de l’Union Européenne EN 50 082-1, 1992.
NETTOYAGE DE LA POINTE DE LECTURE: Utiliser une brosse douce, humectée d’alcool pur
ou dilue. Les liquides de nettoyage vendus dans le commerce peuvent endommager ou corroder
la pointe. II faut toujours brosser de I’arrière vers I’avant, jamais de I’avant vers I’arrière ou d’un
côté à I’autre.
REMARQUE: Assurez-vous que tout diamant de remplacement que vous achetez porte la
garantie suivante sur son emballage: “This Stereo Dynetic Stylus is precision manufactured
by Shure Brothers Inc.” ÉVITEZ LES IMITATIONS DE QUALITÉ INFÉRIEURE ELLES
DETRUIRONT LE RENDEMENT DE VOTRE CELLULE. CHERCHEZ LE NOM DE SHURE SUR
LE SUPPORT DE POINTE EN PLASTIQUE.
Garantie totale de deux ans:
Shure garantit que, pour un usage normal, ce produit sera exempt de tout défaut de fabrication
et de matériaux pour une période de deux (2) ans à compter de la date d’achat. Si ce produit
Shure tombe en panne pendant cette période, appeler le 1-800-516-2525 aux États-Unis pour
obtenir des renseignements sur les réparations, les remplacements ou les remboursements. En
Europe, appeler Shure Incorporated Europe GMBH au +49 (7131) 7214-0 ou +49 (7131) 7214-30
(téléphone rouge du service d’entretien) ou contacter le centre de réparations Shure agréé. Cette
garantie n’est pas applicable en cas d’utilisation abusive ou incorrecte du produit, d’utilisation
contraire aux instructions de Shure, d’usure normale, de catastrophe naturelle ou de réparation
non autorisée.
AUFLAGEKRAFT: In einem vorjustierten P-Mount Arm, nach einbau des Tonabnehmers in einem
P-mount Arm ist eine nachträgliche Korrektur der Auagekraft normalerweise nicht erforderlich.
SKATING KOMPENSATION (falls erforderlich): Die Einstellung der Antiskatingkraft erfolgt nach
den Empfehlungen des Tonarm-Herstellers.
27B2172_M92E.indd 3 8/22/2006 3:34:38 PM
Table of contents
Other Shure Dj Equipment manuals