SIB K35 User manual

Keypad Access Control User Manual

1.Introduction
3.Technical Specifications
12
Operating Current: ≤100mA
Operating Voltage: DC 12-24V
Operating Humidity: 0%~95%
Standby Current: ≤35mA
Operating Temperature: -40℃~60℃
Access ways: Card, code, or multiple combination
methods, mobile APP
2.Features
Feature Specification
Card Type
Keypad Characteristic
Output Way
Access Way
Admin Card
User Capacity
Read 125KHz EM Card and HID Card (Optional)
Read 13.56MHz Mifare card and CPU card (Optional)
Metal backlight keypad
Contain reader mode, the transmission format could be adjusted by user.
Support card plus code, multi cards access ways.
Support admin add card and admin delete card
10,000 card users and 600 fingerprint users.
5.Wiring
No. Color Marks Description
1Green
White
Grey
Yellow
Brown
Red
Black
Blue
Purple
Orange
Pink
Pink
D0
D1
ALARM
OPEN/ BEEP
D_IN/ LED
+12V
GND
NO
COM
NC
BELL_A
BELL_B
2
3
4
5
6
7
8
9
10
11
12
Wiegand input (Wiegand output as reader mode)
Wiegand input (Wiegand output as reader mode)
Alarm signal MOS tube drain output end (optional)
Exit button input end (Beeper input as reader mode)
Door contact switch input (LED input as reader mode) (optional)
Positive power supply or AC power supply end
Negative power supply
Relay NO end
Relay COM end
Relay NC end
Doorbell one end(optional)
Doorbell the other end(optional)
4.Installation
Remove the back cover from the keypad using the supplied special screw driver
Drill 2 holes on the wall for the self-tapping screws and I hole for the cable
Put the supplied rubber bungs to into the two holes
Fix the back cover firmly on the wall with 2 self tapping screws
Thread the cable through the cable hole
Attach the keypad to the back cover. (See the figure below)
This series’ product is a new generation of multi-function standalone access control. It adopts
new ARM core 32-bit microprocessor design, which is powerful, stable and reliable. It contains
reader mode and standalone access control mode etc.. It’s widely applied to different occasions,
such as office, residential communities, villa, bank and prison etc..

3
6.Diagram
4
6.1 Common Power Supply
6.2 Special Power Supply
Note: The doorbell, door contact and alarm function are optional. Note: The doorbell, door contact and alarm function are optional.

5 6
6.3 Reader Mode 7.Sound and Light Indication
Light indicatorOperation Status Buzzer
Beep—
Beep-Beep-Beep
Beep—
Beep
Beep—
Beep-Beep
Alarm
Red indicator flash slowly
Red
Green
Red indicator flash slowly
Red indicator flash slowly
Red indicator flash slowly
Orange
Green
Red indicator flash quickly
Stand by
Operation successful
Operation failed
Read card under card plus code mode
Read multi user cards
Enter programming mode
Enter setting status
Unlocking
Buzzer alarm
Press access code
Press * key
Press digital key
Admin card exit programming
Admin card enter programming
8.Admin Menu
8.1 Standalone Mode Settings
Device Management
Enter
programming Menu Operation steps Description Default
value
Press *
Admin code #
(Default
admin code is
"999999")
New admin code # new admin
code # Change admin code
Set admin add card
Set admin delete card
Reader mode
Standalone access control
mode
Read card *
Read card *
0#
1#
2#
Unlocking code # (4-6 digits)
00
01
02
03
08
Relay toggle mode
WIFI matching Optional
1
Public code09
999999

7 8
Add and Delete Users
Access Ways
Advanced Settings
Enter
programming Menu Operation steps
Delete users
Description Default
value
Enter
programming Menu Operation
steps Description Default
value
Enter
programming Menu Operation
steps Description Default
value
Press *
Admin code #
(Default
admin code is
"999999")
Press *
Admin code #
(Default
admin code is
"999999")
Press *
Admin code #
(Default
admin code is
"999999")
“…” means
repeating the
previous
operation,
Press * key
to exit.
“…” means
repeating the
previous
operation,
Press * key
to exit.
Read card ... * Add card users continuously
Door opening time range: 0-300S
0 equals to 50mS
Alarming time sets 0S, means no alarm
Alarming time range: 1-99 min
Normal working mode
Disable light indicator
Enable light indicator
Disable the keypad backlight
Enable the keypad backlight
Disable buzzer
Enable buzzer
Time of keypad backlight: 2-99 sec
The external alarm and built-in buzzer
will work if wrong operations are over
5 times.
The device will be locked out for 10
min if wrong operations are over 5
times.
Add card users by card number
Add card users by specific ID
number
Add card users by specific ID
number and card number
Add an independent user code
by specific ID number
Add conductive number card
Delete card users by reading
card
Press 8 or 10 digits card
number # … *
Press ID number # press
code # … *
Press ID number # press 8
or 10 digits card number #
input card quantity #
Read card … *
Press 8 or 10 digits card
number #… * Delete card users by card number
Delete users by ID number
Delete all users
Forbidden opening door
Entry by code only
Entry by card only
Entry by card + code
Entry by card or code
Entry by multi-card
Set door open by 1 user card
Set door open by 2-10 user cards
Press ID number # … *
0000#
Press ID number # read
card … *
Press ID number # press 8
or 10 digits card number #
… *
11
31
41 (0-300) # 5
0
0
1
1
1
(1-99) #
1#
2#
0#
1#
0#
1#
(2-99) #
0#
1#
0#
0 #
42
61
62
63
64
4
1
0#
1#
2#
3#
4#
7#
1#
2-10 #
32
13
21
20

9 10
9.Admin Card Operation
9.1 Add Card
10.User Operation
11 Other Operation
11.1 Remove Alarm
8.2 Reader Mode Settings
11.2 Reset to Factory Default
Change the user code by ID number
Change the user code by card
Note:
When the alarm is activated, user can remove the alarm by reading a valid card or pressing
valid admin code .
Note:
The default code “1234” of matching card can’t open the door unless revising other
codes.
Note:
ID number has to be known from admin before changing the code, user code can’t be
default code “1234”.
Note:
Registered user data won’t be deleted when reset to factory default.
Users can reset to the factory default when the admin code is forgotten, or tthe default settings
have been modified, operation as below:
Power off, press and hold the # key or the exit button continuously, power on, release the # key
or the exit button until hearing beep sound twice, the admin code has been reset to 999999,
factory default settings are successful.
Enter programming Menu Operation steps Description Default
value
Press * Admin
code #
(Default admin
code is "999999")
New admin code #
new admin code # Change admin code
Set device number
Wiegand output:26-58 bits
Keypad transmission format 4 bits
Keypad transmission format 8 bits
Virtual card number output
(0-255)#
(26-58)#
0#
1#
2#
Read card Old code # New code # New code #
#
Press
ID number Old code # New code # New code #
Press
9.2 Delete Card
Note:
The delete card is used to delete card users continuously and quickly. When you read the
admin delete card at the first time, you will hear short "BEEP" sounds twice and the indicator
light turns orange, it means you have entered into delete user programming, when you read the
admin delete card at the second time, you will hear long "BEEP" sound once, the indicator light
turns red, it means you have exited the delete user programming.
Read admin delete card Read the 1
st
user card Read the 2
nd
user card Read admin delete card
…
Note:
The add card is used to add card users continuously and quickly. When you read the
admin add card at the first time, you will hear short "BEEP" sounds twice and the indicator light
turns orange, it means you have entered into add user programming, when you read the admin
add card at the second time, you will hear long "BEEP" sound once and the indicator light turns
red, it means you have exited the add user programming.
Read admin add card Read the 1
st
user card Read the 2
nd
user card Read admin add card
…
00
51
52
53
0
Disable the keypad backlight
Enable the keypad backlight
Time of keypad backlight: 2-99 sec
Disable buzzer
0#
1#
(2-99)#
0#
63
64
1
1
0
Alarming time range: 1-99 min
Alarming time sets 0S, means no alarm
(1-99)#
0#
42 0
Reader mode
Standalone access control mode
Relay toggle mode
0#
1#
2#
Enable light indicator
Disable light indicator
1#
0#
62 1
03 1
999999
26
10.1 Change the User Code
Read admin card Read valid user card Press admin codeor or #
Table of contents
Other SIB Keypad manuals