Siemens SIMATIC MV500 User manual

Siemens AG
Digital Industries
Postfach 48 48
90026
NÜRNBERG
GERMANY
Ⓟ
05/2019 Subject to change
Copyright © Siemens AG 2018 - 2019.
All rights reserved
Legal information
Warning notice system
This manual contains notices you have to observe in order to ensure your personal safety, as well as to prevent
damage to property. The notices referring to your personal safety are highlighted in the manual by a safety alert
symbol, notices referring only to property damage have no safety alert symbol. These notices shown below are
graded according to the degree of danger.
DANGER
indicates that death or severe personal injury will result if proper precautions are not taken.
WARNING
indicates that death or severe personal injury may result if proper precautions are not taken.
CAUTION
indicates that minor personal injury can result if proper precautions are not taken.
NOTICE
indicates that property damage can result if proper precautions are not taken.
If more than one degree of danger is present, the warning notice representing the highest degree of danger will
be used. A notice warning of injury to persons with a safety alert symbol may also include a warning relating to
property damage.
Qualified Personnel
The product/system described in this documentation may be operated only by personnel qualified for the specific
task in accordance with the relevant documentation, in particular its warning notices and safety instructions.
Qualified personnel are those who, based on their training and experience, are capable of identifying risks and
avoiding potential hazards when working with these products/systems.
Proper use of Siemens products
Note the following:
WARNING
Siemens products may only be used for the applications described in the catalog and in the relevant technical
documentation. If products and components from other manufacturers are used, these must be recommended
or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and
maintenance are required to ensure that the products operate safely and without any problems. The permissible
ambient conditions must be complied with. The information in the relevant documentation must be observed.
Trademarks
All names identified by ® are registered trademarks of Siemens AG. The remaining trademarks in this publication
may be trademarks whose use by third parties for their own purposes could violate the rights of the owner.
Disclaimer of Liability
We have reviewed the contents of this publication to ensure consistency with the hardware and software
described. Since variance cannot be precluded entirely, we cannot guarantee full consistency. However, the
information in this publication is reviewed regularly and any necessary corrections are included in subsequent
editions.

SIMATIC MV500
Operating Manual, 05/2019, C79000-G8976-C495-02 3
Table of contents
1 Introduction............................................................................................................................................. 5
2 Welcome screen ..................................................................................................................................... 7
3 Description of the WBM........................................................................................................................... 9
3.1 Layout of the WBM ...................................................................................................................9
4 Start page............................................................................................................................................. 15
5 Application ............................................................................................................................................ 17
5.1 Program ..................................................................................................................................17
5.1.1 "Sequence" program step.......................................................................................................22
5.1.1.1 Description ..............................................................................................................................22
5.1.1.2 Program sequence..................................................................................................................23
5.1.2 "Overview" program step ........................................................................................................23
5.1.2.1 Auto-setup...............................................................................................................................24
5.1.2.2 Description ..............................................................................................................................29
5.1.3 "Image acquisition" program step ...........................................................................................29
5.1.3.1 Auto-setup...............................................................................................................................29
5.1.3.2 Image ......................................................................................................................................30
5.1.3.3 Trigger.....................................................................................................................................32
5.1.3.4 Lighting ...................................................................................................................................36
5.1.3.5 E-focus....................................................................................................................................37
5.1.3.6 Verification ..............................................................................................................................37
5.1.4 "Decoder" program step..........................................................................................................39
5.1.4.1 Auto-setup...............................................................................................................................40
5.1.4.2 General ...................................................................................................................................41
5.1.4.3 Format.....................................................................................................................................44
5.1.4.4 Decoding order .......................................................................................................................60
5.1.4.5 Decoder ..................................................................................................................................63
5.1.4.6 Multicode.................................................................................................................................64
5.1.4.7 Evaluation ...............................................................................................................................65
5.1.4.8 MATCH ...................................................................................................................................66
5.1.4.9 N_OK.......................................................................................................................................69
5.1.4.10 Decoder options (standard) ....................................................................................................70
5.1.4.11 Decoder options (ID Genius) ..................................................................................................72
5.1.4.12 Decoder options (1D)..............................................................................................................73
5.1.5 "Result" program step.............................................................................................................76
5.1.5.1 Program format text ................................................................................................................76
5.1.5.2 Error messages.......................................................................................................................89
5.1.6 Image and result display .........................................................................................................94
5.1.7 Image and result view .............................................................................................................96

Table of contents
SIMATIC MV500
4Operating Manual, 05/2019, C79000-G8976-C495-02
6 Settings ...............................................................................................................................................103
6.1 Communication .................................................................................................................... 103
6.1.1 Interfaces ............................................................................................................................. 103
6.1.2 Use....................................................................................................................................... 112
6.1.3 Digital I/O ............................................................................................................................. 117
6.2 Options................................................................................................................................. 119
6.2.1 Lighting................................................................................................................................. 119
6.2.2 Diagnostics & monitoring ..................................................................................................... 122
6.2.3 Extras ................................................................................................................................... 126
6.3 Security ................................................................................................................................ 133
6.4 User management ............................................................................................................... 136
7 Device .................................................................................................................................................139
7.1 Diagnostics........................................................................................................................... 139
7.2 System ................................................................................................................................. 142
7.3 Adapt.................................................................................................................................... 147
7.4 Help...................................................................................................................................... 147

SIMATIC MV500
Operating Manual, 05/2019, C79000-G8976-C495-02 5
Introduction
1
The MV500 optical readers are equipped with a Web server that provides Web Based
Management (WBM). Using the WBM, you can configure your readers. Among other things,
you can create reader-specific programs and program sequences and run diagnostics.

Introduction
SIMATIC MV500
6Operating Manual, 05/2019, C79000-G8976-C495-02

SIMATIC MV500
Operating Manual, 05/2019, C79000-G8976-C495-02 7
Welcome screen
2
After you have called the IP address of your optical reader, a welcome screen opens. This
provides important information from the optical reader that can be integrated into numerous
environments, since HTML5 is not required for this page.
Advantages
●Independent of the operating system or the Web browser you are using.
●Does not require Java Runtime on the visualization device.
●Requires little memory and performance on the visualization device.
●Can be integrated easily into existing applications.
Available HTML pages
Once the connection to the reader has been successfully established, the WBM welcome
screen appears:
Figure 2-1 Optical reader welcome screen

Welcome screen
SIMATIC MV500
8Operating Manual, 05/2019, C79000-G8976-C495-02
Welcome screen
Shows current device information on:
●Device reader revision level
●Firmware version
●Device/host name
●Network information of the interfaces
Start page
This menu item takes you to the Web Based Management (WBM) start page.
Live image display
Displays the images acquired by the optical reader in adjustment mode or processing mode.
If the visualization device provides Java script support, the displayed image is automatically
updated. With the displayed links, you can reach the other pages.
Monitoring
Non-embedded display of the last image processed in processing mode with colored overlay
showing the results of processing (ROIs and details view).
Requires JavaScript support and Internet Explorer as of Version 8.

SIMATIC MV500
Operating Manual, 05/2019, C79000-G8976-C495-02 9
Description of the WBM
3
3.1 Layout of the WBM
Using the WBM, you can configure the SIMATIC MV500 optical readers.
NOTICE
Security recommendation: Enable user management
After starting the WBM the first time, no user management is enabled. To make sure that
no unauthorized persons can access the reader settings, we recommend that you enable
the user management, create new user profiles and delete any existing default user profiles
after starting the WBM for the first time.
For additional information on logging in to WBM and creating/deleting user profiles, refer to
the section "User management (Page 136)".
When you have created new user profiles you need to log in with one of these user profiles
when you restart the WBM.

Description of the WBM
3.1 Layout of the WBM
SIMATIC MV500
10 Operating Manual, 05/2019, C79000-G8976-C495-02
Layout of the WBM
After successfully establishing a connection to the reader and switching to the start page, the
WBM start window appears:
①
Status bar and toolbar
②
Menu tree
③
Main window
Figure 3-1 Start page of the WBM
Status bar and toolbar ①
Above the main window, there is a status bar with the following information:
●Display of the reader status and access status
●Selection of the view
●Drop-down list for selecting the user interface language
●Display of the user profile
●Login drop-down list for login/logout on the WBM (only with active user management)
●Help
A menu-specific toolbar may be located below the status bar and above the main window.
The toolbar is only displayed in the "Application" and "Libraries" menus and has different
functions depending on the menu.
The toolbar and its individual functions are described at the start of each section related to
the menu.

Description of the WBM
3.1 Layout of the WBM
SIMATIC MV500
Operating Manual, 05/2019, C79000-G8976-C495-02 11
Reader status and access status
The reader status shows the current status of the reader.
Table 3- 1 Reader status
Icon
Description
Start
The reader has the "Start" status. This means that the device is currently
in processing mode (RUN).
Stop
The reader has the "Stop" status. This means the device is currently nei-
ther in processing mode nor in productive mode. There is no operation
(STOP).
Edit
The reader has the "Edit" status. This means the device is currently in edit
mode and changes can be made to the configuration.
Adapt
The reader has the "Adapt" status. This means the device is currently in
adaption mode. This mode is started either by the "READ" button or by
the "Full program" function in the program step "Overview > Auto-
adaption".
The access status shows the current status of the WBM.
Table 3- 2 Access status
Icon
Description
Red padlock
Operation is not possible in the "Read only" status because the WBM of
another PC is currently in control of the optical reader.
Blue padlock
The logged-on user is not authorized to change settings.
Red/gray padlock
DISA is active. Only users that have the "Take control" right are capable
of taking over control of the optical reader from the controller.
Green padlock
The currently logged on user has taken control of the optical reader.
Standard view
Use the Standard view to switch between Standard and Extended view. In the Standard
view, the operator controls that are not required for standard applications are grayed out. If
the Standard view is disabled, extended parameters are released for editing.

Description of the WBM
3.1 Layout of the WBM
SIMATIC MV500
12 Operating Manual, 05/2019, C79000-G8976-C495-02
Login area
If user management ("Settings > User management") is switched on, you must log on in this
area to be able to make changes in the WBM with your login.
Help
You use the question mark symbol "?" to open the WBM online help. The help is context-
sensitive. The corresponding help page for the menu in which you are currently working is
called.
Menu tree ②
The menu tree with the different menu items is located in the left margin of the WBM. The
currently selected menu item is highlighted in color.
The following table provides an overview of the menu items and the functions they provide.
Table 3- 3 The menu structure of the WBM
Menu items
Functions
Start page •Retrieving device and network information
•Starting/stopping processing mode of existing programs
Application
Program •Specifying and testing image acquisition settings, reader orientation and
processing task
•Monitoring/controlling processing
Libraries
Verification
Editing verification library
Settings
Communication
Specifying communication settings
Options
Specifying general device settings
Security
Assigning role-specific rights
User management •Enabling/disabling user management
•Creating and deleting user profiles
•Changing passwords

Description of the WBM
3.1 Layout of the WBM
SIMATIC MV500
Operating Manual, 05/2019, C79000-G8976-C495-02 13
Menu items
Functions
Device
Diagnostics •Displaying and backing up diagnostic data from reader
•Creating system image including diagnostics
•Treatment for persistent diagnostics
System •Resetting reader to factory settings
•Saving/restoring device configuration
•Updating the firmware
•Saving/restoring custom GUI
Adapt
Specifying settings for the WBM view
Help •Further help on the WBM and the devices
•Readme
•"Service & Support" contact information
If you are logged in to the WBM as a "User", some menu items can only be used with certain
restrictions. You will find a list of the restrictions in the section "User management
(Page 136)".
Main window ③
The main window shows the contents of the selected menu items. Here, you can configure
the various menu-dependent parameters. The main window is divided up into three columns
in the menu items "Application" and "Libraries".
Message area
The message area displays all WBM-related error messages and warnings (e.g. transfer
errors). If messages or warnings are present, they are displayed at the bottom of the main
window. Note that the message area is only displayed on the start page of the WBM.

Description of the WBM
3.1 Layout of the WBM
SIMATIC MV500
14 Operating Manual, 05/2019, C79000-G8976-C495-02

SIMATIC MV500
Operating Manual, 05/2019, C79000-G8976-C495-02 15
Start page
4
The "Start page" menu contains device and network information as well as information on
the installed internal ring light.
Table 4- 1 "Start page" menu groups
Group
Description
Reader This group shows the following device information:
•Product version
•Article number
•MAC address
•FPGA version
•Firmware version
•Licenses
Internal lamp
Information about the built-in internal ring light is displayed in this group.
E-focus lens
This group displays information about the built-in lens.
Network
This group displays network information about the Ethernet interfaces.
Control
You can start and stop the processing mode in this group.
If messages or warnings are present, they are displayed below the groups in the main
window of the start page.
Table 4- 2 Reader status
Icon
Description
Start
The reader has the "Start" status. This means that the device is currently
in processing mode (RUN).
Stop
The reader has the "Stop" status. This means the device is currently nei-
ther in processing mode nor in productive mode. There is no operation
(STOP).
Button: Start automatic setup of READ function
Using the "Start automatic setup" button, you can automatically adapt all relevant program
settings. This function is identical to the function performed by the "READ" button on the
optical reader.

Start page
SIMATIC MV500
16 Operating Manual, 05/2019, C79000-G8976-C495-02
Automatic disconnection on inactivity
Note that a timer runs in the background of the start page. After 5 minutes of inactivity, the
connection to the reader is automatically terminated. This ensures that the connection to the
reader is not blocked by an inactive user and is shared with other users.
A few seconds before automatic disconnection, a dialog window appears informing the user
of the upcoming disconnection.
This function is only active on the start page and is automatically reset by operator input.

SIMATIC MV500
Operating Manual, 05/2019, C79000-G8976-C495-02 17
Application
5
5.1 Program
The "Program" menu gives you the option of setting the type of processing that the optical
reader executes in one cycle. This task is the main task of the WBM and offers a wide range
of options. These options enable you to adjust the optical reader to suit a wide range of
reading tasks in line with your requirements.
The "Program" menu includes the following functions:
●Creating, editing, saving and deleting programs
Functions during program creation:
–Image acquisition control functions
–Selection of lighting
–Configuration of reading tasks - divided into a sequence of max. 12 reading steps
–Output formatting of results
–Selecting a verification
●Program selection
●Starting processing
●Checking settings and results in processing mode

Application
5.1 Program
SIMATIC MV500
18 Operating Manual, 05/2019, C79000-G8976-C495-02
Structure of the "Program" menu
①
"Program" toolbar
②
Program steps & program-specific toolbar
③
Parameter area
④
Image and result display
⑤
Image and result view
Figure 5-1 Structure of the "Program" menu

Application
5.1 Program
SIMATIC MV500
Operating Manual, 05/2019, C79000-G8976-C495-02 19
Description of the toolbars
Table 5- 1 "Program" toolbar ①
Button
Description
Program sequence part of the toolbar
1)
Sequence
Select the program sequence you want to start.
Save sequence
Click this button to save the selected program sequence ("Sequence" drop-down list).
Edit program
Click this button to edit the selected program ("Program" drop-down list).
Start sequence
Click this button to start the selected program sequence ("Program" drop-down list).
Stop sequence
Click this button to stop the selected program sequence ("Program" drop-down list).
General part of the toolbar
Program
Select the program you want to start.
New element
Click this button to create a new program. You can also create new programs based on
existing programs (copy of "xx").
Save program
Click this button to save the selected program ("Program" drop-down list).

Application
5.1 Program
SIMATIC MV500
20 Operating Manual, 05/2019, C79000-G8976-C495-02
Button
Description
Save program as
•Number
In this text box, enter the program number under which you want to save the current
program.
Value range: 1 ... 15
•Name
In this text box, enter the name under which you want to save the current settings and
the program. This entry is optional.
Possible values: Letters, numbers and underscores. Maximum of 255 characters.
•Comment
In this text box, you can enter your own program-specific information, for example.
Among other things, this is intended to make it easier for you to identify the individual
programs.
•Wait for next image acquisition
Select this check box when you do not want to save the current image but the next
image.
•Save program as
Click this button to save the current settings and the program with the specified name.
•Discard changes
Click this button to discard the changes you have made since the program was saved
last. If the program was newly created and has not been saved since, it will not be
saved and will be lost.
•Cancel
Click this button to close the menu without applying the changes.
Delete program
Click this button to delete the selected program ("Program" drop-down list).
Edit program
Click this button to edit the selected program ("Program" drop-down list).
Start program
Click this button to start the selected program ("Program" drop-down list).
Stop program
Click this button to stop the selected program ("Program" drop-down list).
1)
Note that the program sequence part of the toolbar is only shown when the "Program sequence" option was activated
under "Settings > Options > Extras > Program sequence".
Other manuals for SIMATIC MV500
1
Table of contents
Popular Machine Vision System manuals by other brands

PhaseOne
PhaseOne RP1 1600 installation manual

Omron
Omron STC-HD203 Series Product specifications and user's guide

opto engineering
opto engineering LT2PR Series user manual

ADLINK Technology
ADLINK Technology NEON-2000-JT2-X Series user manual

National Instruments
National Instruments NI myRIO ESSENTIALS GUIDE

Banner
Banner VE200G1B quick start guide