Siemens TIWAY I TI505 User manual

-~
ARTISAN
®
~I
TECHNOLOGY
GROUP
Your definitive source
for
quality
pre-owned
equipment.
Artisan Technology
Group
Full-service,
independent
repair
center
with
experienced
engineers
and
technicians
on staff.
We
buy
your
excess,
underutilized,
and
idle
equipment
along
with
credit
for
buybacks
and
trade-ins
.
Custom
engineering
so
your
equipment
works
exactly as
you
specify.
•
Critical
and
expedited
services
•
Leasing
/
Rentals/
Demos
• In
stock/
Ready-to-ship
•
!TAR-certified
secure
asset
solutions
Expert
team
ITrust
guarantee
I
100%
satisfaction
All
tr
ademarks,
br
a
nd
names, a
nd
br
a
nd
s a
pp
earing here
in
are
th
e property of
th
e
ir
r
es
pecti
ve
ow
ner
s.
Find the Siemens TI505 at our website: Click HERE

SIMA
TIC TIW
A
Y 1
TI505 Network Interface Module
User
Manual
Order Number: PPX:TIWAY–8124–2
Manual Assembly Number: 2587871–0053
Second Edition
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Copyright
1994 by Siemens Industrial Automation, Inc.
All Rights Reserved — Printed in USA
Reproduction,
transmission or use of this document or
contents is not permitted without express consent of
Siemens Industrial
Automation, Inc. All rights, including rights
created by patent grant or registration of a utility model or
design, are reserved.
Since Siemens Industrial Automation, Inc. does not possess
full access to data concerning all of the uses and applications
of customer
’
s products, we do not assume responsibility either
for customer product design or for any infringements of patents
or rights of others which may result from our assistance.
T
echnical data is subject to change.
W
e check the contents of every manual for accuracy at the
time it is approved for printing; however
, there may be
undetected errors. Any errors found will be corrected in
subsequent editions. Any suggestions for improvement are
welcomed.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

MANUAL
PUBLICA
TION HISTORY
TIWAY
I TI505 Network Interface Module User Manual
Order Manual Number: TIW
AY–8124–2
Refer to this history in all correspondence and/or discussion about this manual.
Event Date Description
Original Issue
8/88
Original Issue (2601210–0001)
Second Edition
3/94
Second Edition (2601210–0002)
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

LIST OF EFFECTIVE PAGES
Pages Description Pages Description
Cover/Copyright Second
History/Effective
Pages
Second
iii — vii
Second
viii — ix
Second
1-1 — 1-6
Second
2-1 — 2-20
Second
3-1 — 3-21
Second
4-1 — 4-44
Second
A-1 — A-3
Second
B-1 — B-2
Second
C-1 — C-2
Second
D-1 — D-2
Second
E-1 — E-2
Second
Registration Second
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Contents iiiTIWAY 1 TI505 NIM User Manual
Contents
PREFACE
CHAPTER 1 TIWA
Y I OVER
VIEW
1.1 TIWAY
I FEA
TURES 1-1.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1.2 TIWAY
I OPTIONS
1-2.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1.3 SYSTEM
BLOCK DIAGRAM
1-2.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1.4 TIWAY
I UNIVERSAL COMMAND LANGUAGE, UCL
1-3.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1.5 THE
TI505 NIM
1-4.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
CHAPTER 2 NETWORK DESIGN CONSIDERATIONS
2.1 TIWAY
I NETWORK CONFIGURA
TION 2-1.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2.1.1 Communication
Media
2-2.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2.1.2 Media
Redundancy
2-3.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2.2 RS-232-C
CABLE INST
ALLATION 2-4.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2.2.1 RS-232-C
Connections
2-4.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2.2.2 RS-232-C T
iming Considerations
2-5.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2.3 LOCAL
LINE CABLE INST
ALLATION 2-6.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2.3.1 Local
Line Characteristics
2-6.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2.3.2 Local
Line Cable
2-8.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2.3.3 Local
Line T
ap Housings
2-10.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2.3.4 Planning
Considerations
2-12.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2.3.5 Local
Line T
ap Spacing
2-12.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2.3.6 Cable
Routing
2-14.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2.3.7 Obstructions 2-15
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2.4 LOCAL
LINE BIASING
2-16.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2.4.1 Biasing
Configurations
2-16.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2.4.2 Networks
with only Self-biased Devices
2-17.
. . . . . . . . . . . . . . . . . . . . . . . . . . .
2.4.3 Networks
with a Single Switch-biased Device
2-17.
. . . . . . . . . . . . . . . . . . . . . .
2.4.4 Networks
with T
wo or Mor
e Switch-biased Devices
2-18.
. . . . . . . . . . . . . . . . .
2.4.5 Terminating
the Local Line
2-19.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
CHAPTER 3 INSTALLATION
3.1 GENERAL
REQUIREMENTS
3-1.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.2 INSTALLING
THE NIM
3-4.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.3 SETTING
THE DIPSWITCHES
3-5.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

iv Contents SIMATIC PCS 7 OSx Library Manual
3.4 INSERTING
THE MODULE INTO THE BASE
3-12.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.5 NIM
SWITCHES
3-14.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.6 TI505
NIM DIAGNOSTICS
3-16.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.7 MODULE
LOGIN VERIFICA
TION 3-21.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.8 CONNECTING
THE NETWORK CABLES
3-21.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
CHAPTER 4 NIM PRIMITIVES
4.1 OVERVIEW 4-1.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.2 PURPOSE 4-2
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.3 STRUCTURE
AND OPERA
TION 4-2.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.3.1 Normal
Operation and Exceptions
4-4.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.3.2 Exception
When Reading
4-5.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.3.3 Exception
When W
riting 4-5.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.4 LOGICAL
GROUPS
4-6.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.5 FIELD
DEFINITIONS
4-8.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.5.1 Field
Symbols
4-9.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.5.2 Length
Field – LLLL
4-9.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.5.3 Primitive
Code Field – PP
4-10.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.5.4 Descriptor
Field
4-10.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.5.5 Basic
Data Unit – DDDD
4-11.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.6 DATA
ELEMENT TYPES AND FORMA
TS 4-12.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.7 DATA
ELEMENT LOCA
TION RANGES
4-16.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.8 DATA
FIELD LENGTH RESTRICTIONS
4-17.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.9 TI505
NIM PRIMITIVE DESCRIPTIONS
4-19.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.9.1 Exception
Primitive – Code 00
4-20.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.9.2 Native
Primitive – Code 01
4-22.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.9.3 Status
Primitive – Code 02
4-23.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.9.4 Configuration
Primitive – Code 03
4-24.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.9.5 Primitive
For
mat Configuration – Code 04
4-25.
. . . . . . . . . . . . . . . . . . . . . . . . .
4.9.6 Packed
Native Primitive – Code 05
4-26.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.9.7 Change
State Primitive – Code 10
4-27.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.9.8 Read
Block Primitive – Code 20
4-28.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.9.9 Read
Random Block Primitive – Code 21
4-29.
. . . . . . . . . . . . . . . . . . . . . . . . . .
4.9.10 Write
Block Primitive – Code 30
4-30.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.9.11 Write
Random Block Primitive – Code 31
4-31.
. . . . . . . . . . . . . . . . . . . . . . . . . .
4.9.12 Block
Data Acquisition Primitive Codes 50 51 52
4-32.
. . . . . . . . . . . . . . . . . . .
4.9.13 Record
Data Acquisition Primitive Codes 55 56 57
4-36.
. . . . . . . . . . . . . . . . .
4.9.14 Summary
of Primitives
4-41.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Contents vTIWAY 1 TI505 NIM User Manual
APPENDIX A PM550 CIM REQUIREMENTS A-1.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
A.1 INTRODUCTION A-1.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
A.2 LOCAL
LINE LENGTH
A-1.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
A.3 LOCAL
LINE BIAS AND TERMINA
TION A-1.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
A.3.1 Networks
with Switch-biased Devices and CIMs
A-2.
. . . . . . . . . . . . . . . . . . .
A.3.2 Networks
with Only Self-biasing Devices and CIMs
A-2.
. . . . . . . . . . . . . . . . .
APPENDIX B NETWORK CONFIGURATION DATA SHEET B-1.
. . . . . . . . . . . . . . . . . . . . . .
APPENDIX C NETWORK EVALUATION FORM C-1.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
APPENDIX
D SPECIFICA
TIONS D-1.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
APPENDIX E PRIMITIVE EXAMPLES E-1.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

vi Contents SIMATIC PCS 7 OSx Library Manual
List of Figures
1-1 TIWAY
I System Block Diagram
1-3.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-2 NIM
Simplified Block Diagram
1-6.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2-1 Number
of Local Line Secondaries versus Cable Length
2-9.
. . . . . . . . . . . . . . . . . . . . . . .
2-2 TIWAY I T
ap Housing
2-10.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2-3 Tap
Spacing Examples
2-13.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2-4 Local
Line with T
wo or Mor
e Switch-biased NIMs
2-18.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2-5 Terminating
the Local Line
2-20.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3-1 NIM
Dipswitches
3-5.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3-2 Dipswitch
Summary
3-6.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3-3 Installing
the NIM in the I/O Base
3-13.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3-4 NIM
Switches
3-14.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3-5 NIM
Status Indicators
3-16.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-1 Basic
Primitive Structur
e 4-3.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-2 Binary
W
eight of the Fields
4-4.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-3 Primitive
Request and Response Field For
mat 4-8.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-4 Discrete
Data Element For
mat 4-13.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-5 Packed
Discr
ete Data Element For
mat 4-13.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-6 Forced
W
or
d Data Element For
mat 4-14.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-7 Forced
Discr
ete and CR Data Element For
mat 4-15.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-8 Secondary
System Status Data Element For
mat 4-15.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
A-1 Local
Line Bias and T
ermination A-3.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Contents viiTIWAY 1 TI505 NIM User Manual
List
of T
ables
2-1 RS-232-C
Connections
2-4.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2-2 Pin
Assignments for Local Line Connectors
2-7.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3-1 TI505
Component Power Requir
ements 3-2.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3-2 Network
Addr
ess Selection
3-7.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3-3 Network
Data Rate Switch Settings
3-8.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-1 Logical
Primitive Assignment
4-6.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-2 TI505
NIM Primitive Subset
4-7.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-3 Summary
of Primitive Field Symbols
4-9.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-4 Data
Element T
ypes and Lengths
4-12.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-5 Data
Element Location Ranges
4-16.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-6 Maximum
Read Primitive Data Byte Length
4-17.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-7 Maximum
W
rite Primitive Data Byte Length
4-18.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-8 Summary
of Primitives
4-41.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-9 Summary
of Primitives(extended addr
essing) 4-43.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Preface ix
TIWAY 1 TI505 NIM User Manual
Preface
MANUAL
OVER
VIEW
This
manual contains the information necessary to install and operate the SIMA
TIC
TI505
Network Interface Module (NIM). The following information is provided.
NIM specifications
Installation and testing procedures
Operating instructions and descriptions
SIMATIC
TIW
AYI
primitive descriptions and examples
MANUAL ORGANIZATION
This
manual is organized as follows:
CHAPTER 1 — TIWAY I OVERVIEW contains an overview of the TIWAY I
network
and an explanation of how the TI505 NIM operates within this
network.
CHAPTER 2 — NETWORK DESIGN CONSIDERATIONS describes possible
network
design configurations, and the use of modems with TIW
A
Y I. Local Line
cabling,
biasing, and termination are also discussed.
CHAPTER 3 — INSTALLATION describes NIM installation and diagnostic
procedures.
CHAPTER
4 — NIM PRIMITIVES describes NIM operation and the
primitive
subset
supported by the NIM.
APPENDIX A — SIMATICPM550CIM REQUIREMENTS contains
procedures
for Local Line biasing and termination for networks that contain a
mixture of TI505 NIMs and PM550 Computer Interface Modules (CIM).
APPENDIX
B —
NETWORK CONFIGURA
TION DA
T
A SHEET contains a form
that
will help you plan your network.
APPENDIX
C —
NETWORK EV
ALUA
TION FORM contains a TIW
A
Y network
evaluation form. You can submit the completed form to Siemens for a network
evaluation.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Preface
xTIWAY 1 TI505 NIM User Manual
APPENDIX D — SPECIFICATIONS provides general specifications for the
TI505
NIM
APPENDIX
E — PRIMITIVE EXAMPLES
provides a simple primitive example
in
normal and extended addressing modes.
RELATED PUBLICATIONS
The following publications contain additional information on TIWAY I and TIWAY I
compatible products. To order these publications, contact your Siemens Industrial
Automation, Inc. distributor or sales office. If you need assistance in contacting your
distributor
or sales office in the United States, call 1–800–964–41
14.
Siemens
Manual Number
SIMATIC TIWA
Y I Host Adapter User Manual
PPX:TIWAY–8102
SIMATIC TIWA
Y I Host Software
Programming Manual
for DEC
PDP
–11 PPX:TIWAY–8107
for TI
and IBM
Personal Computers
PPX:TIWAY–8108
for DEC
V
AX
UNILINK
PPX:TIWAY–8123
PM550 Network Interface Module User Manual
PPX:550–8110
SIMATIC5TI
Network Interface
Module User Manual
PPX:5TI–8105
SIMATIC
UNILINK
Host
Adapter
User Manual
PPX:TIWAY–8121
SIMATICTIWAY I TI500
NIM User Manual
PPX:TIWAY–8110
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

TIWAY 1 Overview 1-1
TIWAY 1 TI505 NIM User Manual
Chapter 1
TIWAY
1 Overview
1.1 TIWAY
I FEA
TURES
TIWAY
I is an industrial Local Area Network (LAN) designed to satisfy today’
s factory
and
plant requirements for data acquisition and control of manufacturing processes. It is
a significant enhancement of the Siemens “Local Line,” which supports the PM550
Programmable
Controllers (P/Cs) and DS 990 computer products.
The
TIW
A
Y I network provides
a reliable and flexible communication architecture. T
wo
communication
media options are available:
RS-232-C/423 — provides modem interface for large geographic coverage.
Local Line — provides high noise immunity for networks up to 25,000
feet
(7620 meters).
Throughout this manual, the following networking terms are used.
HDLC — TIWAY I High-level Data Link Control data communications
procedures
with CRC–16 error
-checking and message-length error
-checking
Primary
— HDLC network manager (TIW
A
Y I Host Adapter
, TIW
A
Y I Gateway
,
or
UNILINK Host Adapter with the Network Manager function)
Secondary — device operating as an
HDLC secondary slave (NIMs, UNILINK
Secondary
Adapters, UNILINK Host Adapter acting as a Secondary)
Attached
device — P/C, robot, etc.
(a P/C connected to the NIM, robot connected
to
a UNILINK Secondary Adapter)
Host — computer or intelligent device establishing network communications.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

TIWAY 1 Overview
1-2 TIWAY 1 TI505 NIM User Manual
1.1 TIWAY I OPTIONS
TIWAY
I network products provide a number of options.
TIWA
Y I networks can be configured for short distances or a long distances.
Redundant or single media transmission is available.
Baud rates from 1
10 baud to 1
15.2K baud are available.
TIWAY I devices can operate with modems in either full or half duplex mode,
synchronously
or asynchronously
.
Both NRZ and NRZI data encoding are available.
1.2 SYSTEM BLOCK DIAGRAM
Figure 1Figure 1 illustrates the basic system block diagram of a TIWAY I Network.
System
components include:
Host System Interfaces (including Host Adapters, Gateways, and Network
Control
Modules)
Siemens Programmable Controller Network Interface Modules (NIMs)
UNILINK Secondary
Adapters for interfacing non-Siemens products to
the
TIW
A
Y I Network
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

TIWAY 1 Overview 1-3
TIWAY 1 TI505 NIM User Manual
1.3 TIWAY I UNIVERSAL COMMAND LANGUAGE, UCL
TIWAY I provides a Universal Command Language for all communication on the
network.
The
UCL consists of a set of high-level request/response transactions known as
Primitives.
Primitives are used for:
Reading and writing data
Acquiring status of devices attached to the network
Performing control operations on attached devices
The Host issues requests (Primitives) to the NIMs and Secondary Adapters. The
secondaries
then perform the requested operations on the attached devices and return
the
appropriate response to the Host to complete the transaction. See Figure 1.
Host Systems
Host System
Interfaces Command Initiators
Siemens
Programmable
Controllers
Secondary Adapters
Non–Siemens
Network Media
Responders
devices
Figure 1
TIW
A
Y I System Block Diagram
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

TIWAY 1 Overview
1-4 TIWAY 1 TI505 NIM User Manual
1.4 THE TI505 NIM
The TI505 NIM is the TIWAY I Network Interface Module for the SIMATIC TI505
Programmable
Controllers. See Chapter 3 for a specific listing of controllers supported
by
the TI505 NIM.
The TI505 NIM provides several features which ensure maximum network signal
integrity.
Each
communication port is provided with a “Jabberstop” circuit to disable the
port’s transmitter in the event of a communication port failure. This helps
minimize failures resulting in continuous network transmission which would
dominate
the communication channel.
The NIM provides data integrity checking of network communications.
The NIM meets several stringent noise and environmental specifications.
Built-in
diagnostics
aid in troubleshooting NIM failures and problems.
Chapter
3 provides a description of the diagnostics.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

TIWAY 1 Overview 1-5
TIWAY 1 TI505 NIM User Manual
The
TI505 NIM provides
redundant TIW
A
Y I communication ports. Each of the following
models
supports a specific type of network communication media.
PPX: N mber Port A Port B
PPX:505-7339 Local Line Local Line
PPX:505-7340 RSĆ232ĆC/423 RSĆ232ĆC/423
The
RS-232-C/423 media interface is configured as Data T
erminal Equipment (DTE) and
is
used to connect the NIM to
Data Communication Equipment (DCE) for operation with
modems. This interface uses RS-423 drivers and receivers and operates at RS-423-A
signal levels (+5 or –5 volts). These levels are also RS-232-C compatible. The pin
assignments
for the RS-232-C port are given in Chapter 2.
The
Local Line interface is a differential line port for use with shielded twisted pair cable.
The Local Line interface provides line isolation and high noise immunity for
installations
up to 10,000 feet (25,000 feet depending on system loading
and baud rate
selection). The Local Line interface is recommended for applications where electrical
noise
may be a problem.
Redundancy is supported for either choice of media.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

TIWAY 1 Overview
1-6 TIWAY 1 TI505 NIM User Manual
Figure 2
is a simplified block diagram of the TI505 NIM. The media interface blocks are
intentionally
left unlabeled because the type of media interface depends on which NIM
model
you are using. The blocks are described as follows.
Special
Function Interface Controller (SFIC) — delivers and receives P/C com
-
munications.
NIM controller — translates the communication (between Primitives and the
P/C
communication language).
Communications
controller — supervises data
transactions between the
NIM
and the network host.
NETWORK INTERF
ACE MODULE
SPECIAL
FUNCTION
INTERFACE
CONTROLLER NIM
CONTROLLER COMM.
CONTROLLER
POWER
MEDIA
CIRCUITRY
TO
NETWORK
COMM.
MEDIA
Figure 2
NIM Simplified Block Diagram
The
basic difference in the NIM models is the configuration of the media circuitry
.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Network Design Considerations 2-1
TIWAY 1 Ti505 NIM User Manual
Chapter 2
Network
Design Considerations
2.1 TIWAY I NETWORK CONFIGURATION
TIWAY
I is a multi-drop communication network which consists
of a main trunk cable
(the “spine”) and dropline cables. The network can connect
up to 254 secondaries (e.g.,
TI505 P/Cs) to a host computer. The TI505 NIM provides the interface to the network
host,
enabling the host and the P/C to communicate with each other
.
Also
included with this manual
is a “TIW
A
Y I Network Configuration Data Sheet” (Ap
-
pendix
B). This will assist you in maintaining a complete, up-to-date record of the config
-
uration
of your network, which is especially important if you are using several different
types
of secondaries.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Network Design Considerations
2-2 TIWAY 1 TI505 NIM User Manual
2.1.1 Communication
Media
The following signal-transmission media are supported by TIW
A
Y I:
RS-232-C/423 dedicated lease-line modem interface in which no dial-up is
necessary,
providing extended (cross-continental) geographic coverage.
RF or short-haul modem link-ups (cross-plant or cross-town coverage).
Siemens Local Line (up to 25,000 feet).
NOTE
TIWAY I does not directly support dial-up modems which
require Modem Control Commands for communication
switchover.
This can be done, but specific equipment is required
to
dial the remote number from the host device.
You
can select from either type of media for the network, but you cannot mix the types of
media.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Table of contents
Other Siemens Network Card manuals

Siemens
Siemens SIMATIC NET CP 1623 User manual

Siemens
Siemens DTU3005-B User manual

Siemens
Siemens SIMATIC NET Series User manual

Siemens
Siemens S5-135U/155U User guide

Siemens
Siemens SIMATIC NET CP 343-1 User manual

Siemens
Siemens AFI5100 User manual

Siemens
Siemens SIMATIC PCS 7 Reference manual

Siemens
Siemens NRC User manual
Popular Network Card manuals by other brands

Promise
Promise FAST TRAK100TM user manual

Multitech
Multitech SocketModem IP FCCCFR47 Specifications

Kraun
Kraun 1T1R - USB user guide

LaCie
LaCie 130822 - FireWire 400 ANF 800 USB 2.0 PCI Card... user manual

National Instruments
National Instruments NI 9217 operating instructions

Commell
Commell MPX-350 user manual