Install the ground lug provided
on either side of the panel as
shown. Tighten to 10-15 in.-lbs
(1.1-1.7 N-m).
Lock washer should be installed on nut
side of panel.
2
HD5®Screened Patch Panel Instructions
Place the screened HD5 Panel
(P/N: HD5-S) on sturdy surface
as close to rack as possible and remove
rear cover. If cable slack does not allow
this, mount to 19 inch relay rack or
equivalent with 12-24 screws and
washers, provided.
1
Route cables to point of
termination at the S110®
connecting block and cut cables providing
extra length for termination
(approximately 5-10cm [2-4 in.] past the
S110 connecting block). Ensure that
enough slack is provided to properly
secure cables to rack or rear cable
manager if used.
3For Cables With Foil Shield
Intact:
Fold foil shield back over jacket
(approximately 7.7cm [3 in.]).
Note: If braid exists, proceed to step 8.
Wrap drain wire (if present) around foil
shield within 1.3cm [.5 in.] of jacket end.
(Wrap drain wire a minimum of 3 times
around cable jacket).
6
For Cables With Foil Shield
Intact:
Insert or place cable between ground clip
and spade. Proceed to step 11.
7
Loosen screw retaining ground
clip enough to insert prepared
cable between ground clip and spade.
Note: Ground clip can be removed completely
to ease installation of cable.
4Remove cable jacket
(approximately 7.7cm [3 in.]).
It is recommended to leave the foil intact
(as shown).
• If foil is intact see steps 5-6.
• If foil is removed see step 7.
• If the cable has a braid see steps
8-10.
5
For Braided Cables:
If foil exists beneath braid,
remove foil to point of jacket removal.
10
For Cables With The Foil
Removed:
If foil shield is removed during sheath
removal process, wrap drain wire (if
present) around sheath within 1.3cm [.5
in.] of jacket end. Push cable onto spade
of shield termination assembly. Proceed to
step 11.
Note: If plastic wrap exists between foil and
conductors, slide the cable onto the ground
spade and then remove plastic wrap.
8For Braided Cables:
Note: If braid exists, fold braid back
over itself and wrap drain wire a minimum of 3
times around braid.
9
Spade
ScrewGround Clip
Push
Grab
Slide braid
over itself
Drain Wire Spade
OR
HD5®Screened Patch Panel Instructions
Secure cables to strain relief
tabs with cable ties provided
and trim excess. The cable tie provides
cable strain relief.
12 Tighten screw for ground clip
until it bottoms out.
Note: Remove excess foil that is not in
contact with ground clip.
13 Terminate wires to the S110
connecting blocks.
Note: This can be performed using either
single-position impact tool (P/N: S814-110) or
multi-pair impact tool (P/N: S788J1).
14
For additional cable management
attach the optional rear cable
management bracket, P/N: HD5-RWM
(available separately) to the rear of the
HD5-S.
17 After the rear cable manager is
attached, secure the cables to
the bracket with VCM-series hook and
loop cable managers or cable ties.
It is recommended to route cables to the
left side of the patch panel from the left,
and to the right side of the patch panel
from the right.
18
Mount the HD5-S to the desired
position on an 19 inch relay rack
or equivalent with 12-24 screws and
washers provided.
Slide the rear cover into place and fasten
with two 6 x 32 screws provided.
15 Use the ground lug mounted on
the rear of the panel (from Step
2) to attach a 4.1mm or 5.2mm (#6 or #4
AWG) ground wire (not included) to the
telecommunications grounding bus bar.
16
To assist safe installations, comply with the following:
A. Use caution when installing or modifying
telecommunications circuits.
B. Never touch uninsulated wire terminals unless
the circuit has been disconnected.
C. Never install this device in a wet location.
D. Never install wiring during a lightning storm.
For Braided Cables:
Insert or place cable between
ground clip and spade as shown. Proceed
to step 11.
11
Rev. A 08/06 100.14978
To assist safe installations, comply with the following:
A. Use caution when installing or modifying
telecommunications circuits.
B. Never touch uninsulated wire terminals unless
the circuit has been disconnected.
C. Never install this device in a wet location.
D. Never install wiring during a lightning storm.
Ground Clip
Spade
HD5-RWM
Eyelets
© 2006 Siemon
www.siemon.com
Siemon — UK
Surrey, England
Tel: (44) (0) 1932 571771
Siemon — North America
Watertown, Connecticut
Tel: (1) 866-548-5814
Siemon — Australia
Sydney, Australia
Tel: (61) 2 9452 2666
Siemon — CASA
Central & South America
Bogota, Columbia
Tel: (011) 571 317 2121
Siemon — China
Beijing, P.R. China
Tel: (86) 10 6559 8860
Siemon — France
Paris, France
Tel: (33) 1 46 46 11 85
Siemon — Germany
Frankfurt, Germany
Tel: (49) (0) 69 97168 184
Siemon — Italy
Milano, Italy
Tel: (39) 02 64 672 209
Siemon — Japan
Tokyo, Japan
Tel: (03) 5437 1580
Siemon — Southeast Asia
Singapore
Tel: (65) 345 9119

Popular Network Hardware manuals by other brands

Digi One SP quick start guide

Digi

Digi One SP quick start guide

Funkwerk elmeg hybrid 300 installation guide

Funkwerk

Funkwerk elmeg hybrid 300 installation guide

evertz 7700 Series manual

evertz

evertz 7700 Series manual

Western Digital My Book Studio user manual

Western Digital

Western Digital My Book Studio user manual

evertz 7700 Series manual

evertz

evertz 7700 Series manual

Pico Macom TSHP-C12 Specifications

Pico Macom

Pico Macom TSHP-C12 Specifications

Lorex LNR200 netHD Series Quick connection guide

Lorex

Lorex LNR200 netHD Series Quick connection guide

ADC Baluns Series Specification sheet

ADC

ADC Baluns Series Specification sheet

CommScope FPX Series user manual

CommScope

CommScope FPX Series user manual

RTP 3108 Technical manual

RTP

RTP 3108 Technical manual

GeoVision GV-IP Decoder Box user manual

GeoVision

GeoVision GV-IP Decoder Box user manual

Paradyne Jetstream CPX-1000 Installation and operation guide

Paradyne

Paradyne Jetstream CPX-1000 Installation and operation guide

R.V.R. Elettronica PTX30-UHT Installation, Technical and Maintenance  Manual

R.V.R. Elettronica

R.V.R. Elettronica PTX30-UHT Installation, Technical and Maintenance Manual

ADTRAN NetVanta 6330 Series quick start

ADTRAN

ADTRAN NetVanta 6330 Series quick start

Compaq StorageWorks AIT 35GB AutoLoader Overview and installation

Compaq

Compaq StorageWorks AIT 35GB AutoLoader Overview and installation

Kathrein K-BOW Platform 2 General description manual

Kathrein

Kathrein K-BOW Platform 2 General description manual

MikroTik Chateau LTE18 ax quick guide

MikroTik

MikroTik Chateau LTE18 ax quick guide

CopperOptics PairGain PG-FLEX FRC-754 manual

CopperOptics

CopperOptics PairGain PG-FLEX FRC-754 manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.