- Read and understand all instructions for proper installation and use of this product as improper use
may lead to serious injury or death
- To remove the cabinet from the pallet for final placement, ensure the pallet is located on a level
surface and remove the two (2) bolt-down brackets. Once removed, be sure the sufficient personnel
to safely remove the cabinet from the pallet.
NOTE: These two (2) bolt-down brackets can also be used as stabilizing
brackets once the cabinets are in their final position within the
Telecommunications space.
- Obtain adequate assistance to stabilize the cabinet during movement. Do not attempt to move large
cabinets with a single person. All equipment must be unloaded from the cabinet prior to movement.
- “Temporary Transport”
Optional castors are available for relocation of the cabinets. While castors are capable of supporting
a fully loaded cabinet, they should only be used to move the cabinet between locations. When
relocating cabinets using castors, they must be moved with extreme care a they may tip if they
experience sudden stops, excessive force, or travel over irregular surfaces. It is recommended to
move the cabinet using the front or rear of the cabinet as the leading edge – do not push on the
sides. Once in place, the leveling feet (and bolt-down brackets) shall be fully deployed to offer
maximum stability.
- A standalone cabinet should be leveled, stable and anchored to the floor. Two or more cabinets can
be bayed together (coupled) to enhance their stability. Each cabinet should be anchored to the floor.
- Before loading equipment in the cabinet, be sure to adjust the leveling feet to level the cabinet. Do not
use castors to stabilize the cabinet, always anchor the cabinet frame to the floor.
- Always load the cabinet such that the heaviest equipment (e.g. UPS Units, large enterprise switches)
is located at the lowest point in the cabinet and add lighter equipment on higher levels. This will serve
to further reduce the potential risk of cabinets tipping over. Utilize the bolt-down brackets will also help
in this regard. The same consideration should be taken when and if shelving is deployed within the
cabinet – especially when using sliding shelves – as loads placed on them destabilize the cabinet when
extended from within the confines of the cabinet.
- The maximum load of the cabinet should not exceed; “TR” 800kg (1760lbs), “DC” 1000kg (2200lbs)
- The maximum anticipated ambient temperature inside a fully loaded cabinet system is (10°C – 60°C)
- The enclosure cabinets are intended to be installed in accordance with all applicable requirements
of the National Electrical Code (NEC) and the local Authority Having Jurisdiction (AHJ).
- The minimum spacings between the accessories and components and the enclosure cabinet shall be
maintained for safe operation of the equipment when installed in accordance with the NEC.
- The 600mm cabinet can support many equipment configurations. The amount of force required to
tip or destabilize the cabinet differs with each configuration. Be sure to read and follow your
equipment manufacturer’s specific assembly and safety instructions.
- When servicing slide mounted equipment (e.g. – servers, KVM devices), secure all
equipment, other than the unit being serviced, in position to prevent them from
inadvertently sliding out and destabilizing the cabinet. Also, be sure to extend only one
sliding unit at a time as the extension of multiple units may result in the cabinet tipping over.
When extending sliding units, do so very slowly as quick extension of these units can also
cause the cabinet to tip over.