This appliance may be installed in an
aftermarket, permanently located,
manufactured (mobile) home, where not
prohibited by local codes.
Tools Required :
#Pipe Wrench
#Adjustable Open End
Wrench
#Pipe Sealer
Included in your set :
#Bi-Flo Burner Pan Assembly
#Gas Connection Kit
#Burner Granules, Crushed
Lava Rock & Ember Material
All sets come with four (4) Base Logs and Top Logs as follows:
Model Qty Total Logs Qty
18 4 8
24 6 10
30 8 12
MODEL NUMBERS SO, MP, MO
-18 -24 -30
FIREPLACE MIN.
WIDTH 30" 36" 42"
FIREPLACE MIN.
DEPTH 14" 14" 14"
MIN. PERMANENT
DAMPER OPENING 31.2 sq.in/
8ft. vent heig
ht
45.5 sq.in/ 8ft.
vent height 52.4 sq.in/ 8ft.
vent height
GENERAL INFORMATION
Thank you for choosing a SIERRA RADIANT HEAT GAS
LOG manufactured by Sierra Products, Inc. Please read
the following installation guide before attempting to install
your appliance.
Installation and repair should be done by a qualified
service technician. The appliance should be inspected
before use and at least annually by a professional service
person. More frequent cleaning may be required due to
excessive lint from carpeting, bedding material, etc. It is
imperative that control compartments, burners and
circulating air passageways of the appliance be kept
clean.
INSTALL THIS APPLIANCE ONLY IN A SOLID-FUEL
BURNING FIREPLACE WITH A WORKING FLUE AND
CONSTRUCTED OF NONCOMBUSTIBLE MATERIAL.
All models are to be used with NATURAL GAS ONLY.
For LPG installations a LPG Safety Pilot Kit P/N 10868
must be installed per manufacturers instructions.
Solid fuels MUST NOT be burnt in a fireplace where a
decorative appliance is installed.
Installation and provisions for combustion and ventilation
air must conform with the National Fuel Gas Code, ANSI
Z223.1.
The installation of gas appliances vary with the locality.
Please check local building codes prior to installation to
insure conformance with these codes.
Provide adequate clearances around air openings into the
fireplace hearth and adequate accessibility clearance for
servicing and proper operation. Never obstruct the front
opening of the fireplace.
CAUTION - This log set is to be used only in a fully
vented solid fuel burning fireplace. The fireplace should
be in full operational order prior to installation of gas log
set. Before installing gas logs, fireplace must be
checked for proper draw, otherwise gas logs will not
operate properly and cause an unsafe condition. If
proper draw is not present, inspection of the fireplace flue
venting system and/or termination will be required. If
fireplace does not have proper venting, there will be soot
accumulation on the log set and around fireplace
surround. This may cause soot to accumulate on walls
and furniture near the fireplace. Sooting is caused by
improper placement of logs or burner which, in turn, will
produce excessive carbon monoxide.
NOTE: Some sooting is normal, occasionally a carbon
soot coating may accumulate on some areas of the logs.
Check log placement, logs should not `trap' the flame
beneath the logs. Sooting may be removed by brushing
the logs with a soft bristle brush.
WARNING: Prolonged exposure to excessive
amounts of Carbon Monoxide can be extremely
hazardous to your health, and may cause loss of life.
Do not use this appliance if any part has been under
water. Immediately call a qualified service technician to
inspect the appliance and to replace any part of the
control system and any gas control which has been
underwater.
Any safety screen or guard removed for servicing this
appliance must be replaced prior to operating the logs.
Keep the appliance area clear and free from combustible
materials, gasoline and other flammable vapors and
liquids. Never leave small children unattended near an
operating appliance.
NOTE - IF THE FIREPLACE IS EQUIPPED WITH
GLASS DOORS, THE DOORS MUST BE FULLY OPEN
WHEN OPERATING THE LOG SET.
INSTALLATION INSTRUCTIONS
CAUTION - MAKE SURE ALL GAS TO SUPPLY LINE
IN FIREPLACE IS SHUT OFF BEFORE PROCEEDING.
The fireplace must have a minimum inside height of 16
inches and a depth and width as shown in the chart
below. All installations have a minimum flue inside
diameter of 8 inches and a minimum height of 8 feet for
entire venting system. The chimney height must be at
least 6 ft.
The minimum size of the fireplace in which the log set
may be installed must be as follows:
DAMPER STOP INSTALLATION
A minimum permanent free opening must be maintained
by either the fireplace chimney or chimney damper to vent
the flue gas (see chart ).
Ver 04/26/16 2P/N 140032R3