Sigma-Tech SMP-40300P User manual

Sigma-tech
Reguleated DC Power Supply Unit
Model : SMP-40300P
Serial No : JU14-1 4 6 2
User Manual
Sigma-Tech
경기도 부천시 오정구 내동 243-2 Tel:032)675-3903 Fax:032)675-3905 http://www.tech-sigma.com

10. Certificate of Calibration
Contents
4. Facial Functions
4-1) Facial Configuration
4-2) Configuration
3. How to use
6. Function explanation in the back
1. Overview
2. Important Instructions
Sigma-tech
6-1) Terminal Block Diagram
6-2) Input or Output Terminal Block
4-4) Name and functions of each part
4-3) Name and functions of each part
5. How to use
7. Insturctions for using output line
9. Outside view
경기도 부천시 오정구 내동 243-2 Tel:032)675-3903 Fax:032)675-3905 http://www.tech-sigma.com
8. Specification
5-1) Operation in Power On

bolt break this equipment.
If the stability of ouput voltage is important, please do Remote sensing.
align the polarities of ground on both sides. If not, the output will be short.
Sigma-tech
1. Overview
has independent OP AMP. With high accuracy and smooth switching,
2, Important Instructions before using
The SMP-Series is semi-permanent power supply with high accuracy and high
reliability. The SMP-Series include many kinds of standard products which provide different
Do not use when the temperature is over 40 degrees Celsius.
it can be DC power for both constant voltage and constant current. It is also
protected against any access.
Please check the standard before applying the input.
D. It displays the access of Juper Code. The output of short or overload with unfastened
경기도 부천시 오정구 내동 243-2 Tel:032)675-3903 Fax:032)675-3905 http://www.tech-sigma.com
capacity to be used as a power supply of diverse euipments.
E. Evade the use in the environment with many dust, corrosive gas and etc.
If not, please put this in any case or room.
C. Do not put any item on this equipment or around this equipment.
A. It can be broken if the input is over the specified input voltage.
B. When you ground output terminals on both the face and the back, please
Automatic VC limiter equipped in SMP power supply

1) Please connect after checking the AC input voltage in specification-standard.
2) Please turn the handle for constant current clockwise and the handle for contant voltage
counterclockwise.
3) If turn on the switch and turn the handle for constant voltage clockwise, the output
voltage increases. Please set at the voltage you need.
4) Once turn off the switch and connect load to the output terminal,
(+) and (-) terminals can be grounded because both terminals are sperated with the frame.
Please earth after joining one output terminal to Frame Ground.
5) if you turn on the switch, CV lamp will be turned on and the required voltage will be
provided.
6) If the load is short or an excess current, it is controlled as a constant curent at the
maximum current to decrease output voltage proportional to the impedence in the load. It
ends up preventing the overcurrent. The voltage become constant voltage if the load get
back on track. For the persnickety load, please make output shourt and set the preferred
current with the handle ahead of connecting. Constant current displays on an ammeter and
the value will be the set-point for prevention of overcurrent.
7) The minimum output will be provided if the handle for constant voltage is fully
경기도 부천시 오정구 내동 243-2 Tel:032)675-3903 Fax:032)675-3905 http://www.tech-sigma.com
A. In case of regulated power supply
voltage operation.
This power supply can support constant current If resistive load occurs in ordinary constant
3. How to use
It is DC power supply for both constant voltage and constant current.
Sigma-tech

turned counterclockwise or it is short between the terminals on the back and
the output voltage and current enter the set-value. And the minimum output
will be generated with the voltage over 10mV at the output port and counter
polarity. If counter polar voltage is applied, it can be broken.
B. In case of constant current regulated power supply
1) Please check the input caacity.
If your product has output range transition, tune it to the required range
2) Turn the handle for constant voltage fully clockwise and the handle for constant
current fully counterclockwise.
3) Make sure you connect the load with the output terminal. Please connect
one end of ordinary outut terminal (+) and (-) to Frame Ground and earth on it.
4) Set the current you need with the handle for constant current because CC lamp
will turn on if you turn on the switch.
5) When the resistive load increase during the constant current operation, the
output voltage increase proportional to the resistance. Thus, please set the output
voltage with the handle for CV before connecting the load.
This prevent the overcurrent to the load because constant voltage operation
automatically changes when the load resistance and constantcurrent is set.
경기도 부천시 오정구 내동 243-2 Tel:032)675-3903 Fax:032)675-3905 http://www.tech-sigma.com
Sigma-tech

C. Remote Control Function
1, Remote Function
1-A) Lamp(Blue) turn on if remote S/W is turned on
1-B) The voltage is set from 0 to 10 volt according to input at the EXT
1-C) Output voltage displays according to the set value and the output is permitted
by external equipment(PC, PLC and etc).
1-D) Do not common the (-) on EXT input with (-) on DC output.
EXT input (+,-) 0-10V permit the independent control voltage.
1-E) If EXT, A point of output On/Off in Input or control terminal block should be
on to activate DC output
(Remote function is optional)
2. Local function
2-A) Lamp(Blue) will be turn off if remote s/w is at local.
2-B) Facial voltage volume control the voltage
3. Protection function
3-A) OVP function
If the set voltage is over, OVP Lamp(Yellow) will be on and the output voltage will
be automatically down.
Then, you need to turn off Power S/W and turn on after 2 or 3 seconds.
3-B) OCP function
If the set current is over, C/C Lamp(Red) will be turned on.
3-C) Fan Motor
Auto: If Heat Sint temperature is below 50 degrees Celsius, it's off. If not, it's on.
Manual: Fan Motor On(always)
Sigma-tech
경기도 부천시 오정구 내동 243-2 Tel:032)675-3903 Fax:032)675-3905 http://www.tech-sigma.com

D. Repair and inspection
To keep the initial performance or prevent unexpected accidents, you need a
a periodic check.
A) Cover Panel
Please clean the cover panel with alcohol or a weak neutral detergent and cotton
flannel.
B) The Internal
Remove the dust with vacuum cleaner after the power code is plugged out.
C) Please check the insulation resistance frequently.
D) No strange sound is accepted.
the life of a fan motor is about 40,000 hours in the temperature of 40 degrees
E) When fuse is replaced, AC input power switch should be off.
경기도 부천시 오정구 내동 243-2 Tel:032)675-3903 Fax:032)675-3905 http://www.tech-sigma.com
Sigma-tech

It is a mode to set initial parameter and functions.
With power on, setthe voltage or current with voltage and current VR.
Connect output line to the load and turn on the output on/off SW.
3, CV Lamp 4, Output On Lamp 5, CC Lamp
14, Output On/Off S/W
15, Output Test Point
13, Fan Motor S/W
1, Power S/W 2, Current,Viktage Display
경기도 부천시 오정구 내동 243-2 Tel:032)675-3903 Fax:032)675-3905 http://www.tech-sigma.com
12, Output Current VR (Output current adjustment)
6, OVP Set S/W 7, OVP ADJ VR
8, OCP Set S/W 9, OCP ADJ VR
10, Current Set S/W (Don't use)
11, Output Voltage VR (Output voltage adjustment)
4-1) Facial configuration
Sigma-tech
4. Facial function manual
4-2) Configuration

After pushing OVP button at the right side, turn OVP ADJ until the value is over predefined
power value.
After pushing OCP button at the right side, turn OCP ADJ until the value is over predefined
power value.
Sigma-tech
경기도 부천시 오정구 내동 243-2 Tel:032)675-3903 Fax:032)675-3905 http://www.tech-sigma.com
1.Voltage and Current setting
3.Over Current Protect (OCP) setting
A. Facial setting FND configuration
2.Over Voltage Protect (OVP) setting
Turnning Voltage and Current VR
4-3) Name and function of each part

After pushing CUR button at the right side, turn Current VR to set the value.
The voltage output of power is over the set-value.
The current output of power is over the set-value.
경기도 부천시 오정구 내동 243-2 Tel:032)675-3903 Fax:032)675-3905 http://www.tech-sigma.com
B. Err FND configuration
Over Current Protect (OCP) Err
Over Voltage Protect (OVP) Err
Sigma-tech
4.Current (CUR) setting (Don't use)

It could be 110% of standard. If the sensing value is over the set value, power
will stop. Then, turn off the power and turn on again.
4-4) Name and function of each part
3. Out On : On if the output current or voltage is out.
Sigma-tech
A. Indicator LED
1. CV : On if the constant voltage is under the output control of power.
2. CC : On if the constant current is under the output control of power.
- Current : input the current value of power under local status
- FND : display the information of voltage, current and etc.
B. the kinds of error
C. Button function
will stop. Then, turn off the power and turn on again.
OCP
The output voltage is over OCP set value
- OCP : set the max value of Over Current Protect
OVP
경기도 부천시 오정구 내동 243-2 Tel:032)675-3903 Fax:032)675-3905 http://www.tech-sigma.com
Err
Contents
- Voltage : input the voltage value of power under local status
OTP
- On/Off : Control the output of power under local status.
- OVP : set the max value of Over Voltage Protect
The temperature in Power is over 85°C(option)
The output voltage is over OVP set value
It could be 110% of standard. If the sensing value is over the set value, power

Basically, the controller always displays the corresponding value by AD sensing of
output voltage and current of power. If user want to change data of current or
voltage, he/she can do with the V/R of voltage or current.
In case of local status, it is same with the ordinary power operation.
5-1) Power On : Operation explantion
Push CUR button 1 time. Then, turn Current VR clockwise to set required
current. ( The current setting mode will be back after 10 seconds)
C. OVP setting mode
Push OVP button 1 time. Then, turn OVP ADJ VR clockwise to set required
OVP value. ( THE OVP mode will be back after 10 seconds. )
D. OCP setting mode
Push OCP button 1 time. Then, turn OCP ADJ VR clockwise to set required
OCP value. ( THE OCP mode will be back after 10 seconds. )
경기도 부천시 오정구 내동 243-2 Tel:032)675-3903 Fax:032)675-3905 http://www.tech-sigma.com
Turn Voltage VR clockwise to set required voltage.
5, How to use
B. Current setting mode
A. Voltage setting mode
Outline)
Sigma-tech

2. Feed Back Senser Terminal Block
Pin No 4 : Earth
Pin No 3 : S-
3. Output Terminal (-)Block
Pin No 1~3 : (-) Block
DC Output 40Volt 300Ampere
Pin No 2 : Earth
Pin No 1 : R type
Pin No 2 : S type AC 220Volt 60Hz 3Ø
Pin No 3 : T type
4. Input Terminal Block
경기도 부천시 오정구 내동 243-2 Tel:032)675-3903 Fax:032)675-3905 http://www.tech-sigma.com
Pin No 1 : S+
Sigma-tech
6. Back side functions
6-2) Input or Output Terminal Block
1. Output Terminal (+)Block
Pin No 1~3 : (+) Block
6-1) Terminal Block configuration

7. Instruction for using output line
You should connect the fleet of joint code or coverknife switch which has enough electrical
14
50
80
250
allowable current(A)
8
30
60
200
***** In case of output wire, see below.
Wire thickness(mm)
경기도 부천시 오정구 내동 243-2 Tel:032)675-3903 Fax:032)675-3905 http://www.tech-sigma.com
Sigma-tech
capacity. If not, it may cause a trouble of heat. Please avoid using table tab.
Wire thickness(mm)
80
allowable current(A)
5.5
20
38
100
2
10
22

SMP SMP SMP SMP SMP
40300P 3050 30100 30200 30500
0∼40V 0∼30V 0∼30V 0∼30V 0∼30V
0∼300A 0∼50A 0∼100A 0∼200A 0∼500A
less than
.008%+5mV
current ope
ration value
12KVA 1.5KVA 3KVA 6KVA 15KVA 최대부하
40V 30V 30V 30V 30V Digital
300A 50A 100A 200A 500A Digital
300 Kg 46 Kg 70 Kg 200 Kg 340 Kg
600(W) 440(W) 440(W) 600(W) 600(W)
1000(H) 250(H) 250(H) 800(H) 1000(H) mm
650(D) 520(D) 520(D) 650(D) 650(D)
Z
(Z:60Hz load Impedence)
Indicator
Input voltage
AC 220VOLT ±20V 60Hz 3Ø (three phases)
Input max current
CC Ripple Current
Maximum COV+10
mV r.m.s
경기도 부천시 오정구 내동 243-2 Tel:032)675-3903 Fax:032)675-3905 http://www.tech-sigma.com
(F.S 2.5 level)
Weight(about)
Size
(Maximum)
*** Case Size and weight may be different according to the specification.
Stability of CV
less than 0.005%+3mV
CV Ripple voltage
less than 3mV r.m.s
Stability of CC
less than 0.05%+10mV(about all input overloading)
STP Serise
Type name
note
Specification
Output voltage
Output current
1. Ambient temperature : 0∼40℃
1. Cooling system : Air-cooled (FAN cooling)
1. Manual : an instruction manual 1ea
1. Test result : 1ea (seperately attached)
1. A circuit diagram : 1 ea (seperatately attached)
1. section resistance : over 20 Mohm
Sigma-tech
1. Protection function : VC Limit function (OVP function)
1. Output polarity : (+),(-) selectable
8. Specification
In common

Sigma-tech
경기도 부천시 오정구 내동 243-2 Tel:032)675-3903 Fax:032)675-3905 http://www.tech-sigma.com
9. Outside view

10mV
10mV
10mV
10mV
more than
During 1min
insulation strength
AC 1000 Volt
경기도 부천시 오정구 내동 243-2 Tel:032)675-3903 Fax:032)675-3905 http://www.tech-sigma.com
Constant
3Ø
Gross Weight
300 Kg
Insulation resistance
between P-E
20 Mohm
Input Frequency
50Hz 60Hz
Demension
W : 600 mm
D : 650 mm
H : 1000 mm
Input Voltage
100V 110V 200V 220V
Safety device +10%
Over-Voltage Protectot (OVP)
Over-Current Protectot (OCP)
Cooling System
Air-cooled
Voltage Indicator
16 Bit A/D
40.00 Volt
Current Indicator
16 Bit A/D
300.0 mAmpere
Line Regulation
(± 10% Move)
Voltage
Less Than
Current
Less Than
Load Regulation
(0 ∼100% Move)
Voltage
Less Than
Current
Less Than
Output Voltage
DC 40 Volt
Output Current
DC 300 Ampere
Ripple & Noise Less Than
3mV
(RSM)
Sigma-tech
10. Certificate of Calibration
Reguleated DC Power Supply
2014, July.
Model : SMP-40300P
Serial No. JU14-1462

Name
adress
Name
adress
④Don't use or contain this in hot or moistful place.
(Operation temperature:0℃~45℃, Operation humidity:10%~85%)
(Please read the manual before you use and be careful the followings specially)
①Before you use, you need to be well-informed of how to handle this product.
②Before connecting the power, check the selected voltage is same with the input voltage
③You should use the standard fuse.
①This period count from the date of the discontinued.
Warranty Information
Instruction for warranty
①By carelessness of a user
②By natural disasters including fire, earthquake and thunder
③By wrong power setting
④By repair or remodeling of others excluding sigma tech and the purchasing site.
1. Warranty period is 2 years. The repair cost will be free only if it is to be detective from
normal use.
Sigma tech
Store
TEL
3.The period of possesing parts for repair is 5 years.
The date of bought
Customer
TEL
2. The repair cost will be asked if the breakdwon is caused by following case
Sigma-tech
경기도 부천시 오정구 내동 243-2 Tel:032)675-3903 Fax:032)675-3905 http://www.tech-sigma.com
Thank you for your expression of confidence in our product. The unit you have purchased
is protected based on the date of purchase. Please record the date for after-sale service.
Model name
Reguleated DC Power Supply
Model
Product no.
제품보증서
Table of contents