PR 2220 User manual

SWITCHMODE POWER SUPPLY
Type 2220
CONTENTS
Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Safety instructions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Declaration of Conformity . . . . . . . . . . . . . . . . . . . . . . . . . 16
How to dismantle SYSTEM 2200 . . . . . . . . . . . . . . . . . . . 17
Applications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Technical characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Input . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Electrical specifications. . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Order . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Block diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
11
DK
UK
FR
DE
Side 1
Page 11
Page 23
Seite 35
SIGNALS THE BEST
2220
Switchmode
Power Supply
No. 2220V102-IN (0942)
From ser. no. 970003001
For further information contact Omni Instruments by phone on
UK / Europe Office
Tel: +44 (0)845 9000 601
Fax: +44 (0)845 9000 602
info@omniinstruments.co.uk
www.omniinstruments.co.uk
USA / Canada Office
Tel +1-866-849-3441
Fax +1-866-628-8055
info@omniinstruments.net
Australia / Asia Pacific Office
Tel +61 (0)282 442 363
Fax +61 (0)294 751 278
info@omniinstruments.com.au
www.omniinstruments.com.au
www.omniinstruments.net

1312
SYMBOL IDENTIFICATION
Triangle with an exclamation mark: Warning / demand.
Potentially lethal situations.
The CE mark proves the compliance of the module with
the requirements of the directives.
The double insulation symbol shows that the module is
protected by double or reinforced insulation.
WARNING!
This module is designed for connection to hazardous electric volt-
ages. Ignoring this warning can result in severe personal injury or
mechanical damage.
To avoid the risk of electric shock and fire, the safety instructions
of this manual must be observed and the guidelines followed.
The electrical specifications must not be exceeded, and the
module must only be applied as described in the following.
Prior to the commissioning of the module, this manual must be
examined carefully.
Only qualified personnel (technicians) should install this module.
If the equipment is used in a manner not specified by the
manufacturer, the protection provided by the equipment may
be impaired.
WARNING!
Until the module is fixed, do not connect hazardous voltages to
the module. The following operations should only be carried out
on a disconnected module and under ESD safe conditions:
Dismantlement of the module for setting of DIP-switches
and jumpers.
General mounting, connection and disconnection of wires.
Troubleshooting the module.
Repair of the module and replacement of circuit breakers
must be done by PR electronics A/S only.
WARNING!
To keep the safety distances, modules with two built-in relays
must not be connected to both hazardous and non-hazardous
voltages on the same module’s relay contacts.
SYSTEM 2200 must be mounted in socket type S3B Releco
(order no 7023).
GENERAL
HAZARD-
OUS
VOLTAGE
INSTAL-
LATION

The following apply to fixed hazardous voltages-connected modules:
The max. size of the protective fuse is 10 A and, together with a power switch, it
should be easily accessible and close to the module.
The power switch should be marked with a label telling it will switch off the
voltage to the module.
CALIBRATION AND ADJUSTMENT:
During calibration and adjustment, the measuring and connection of external
voltages must be carried out according to the specifications of this manual.
The technician must use tools and instruments that are safe to use.
NORMAL OPERATION:
Operators are only allowed to adjust and operate modules that are safely fixed in
panels, etc., thus avoiding the danger of personal injury and damage. This means
there is no electrical shock hazard, and the module is easily accessible.
CLEANING:
When disconnected, the module may be cleaned with a cloth moistened with
distilled water.
LIABILITY:
To the extent the instructions in this manual are not strictly observed, the
customer cannot advance a demand against PR electronics A/S that would
otherwise exist according to the concluded sales agreement.
1514
SAFETY INSTRUCTIONS
DEFINITIONS:
Hazardous voltages have been defined as the ranges: 75 to 1500 Volt DC, and
50 to 1000 Volt AC.
Technicians are qualified persons educated or trained to mount, operate, and
also troubleshoot technically correct and in accordance with safety regulations.
Operators, being familiar with the contents of this manual, adjust and operate the
knobs or potentiometers during normal operation.
RECEIPT AND UNPACKING:
Unpack the module without damaging it and make sure that the manual always
follows the module and is always available. The packing should always follow the
module until this has been permanently mounted.
Check at the receipt of the module whether the type corresponds to the one
ordered.
ENVIRONMENT:
Avoid direct sunlight, dust, high temperatures, mechanical vibrations and shock,
as well as rain and heavy moisture. If necessary, heating in excess of the stated
limits for ambient temperatures should be avoided by way of ventilation.
All modules fall under Installation Category II, Pollution Degree 1, and Insulation
Class II.
MOUNTING:
Only technicians who are familiar with the technical terms, warnings, and
instructions in the manual and who are able to follow these should connect the
module.
Should there be any doubt as to the correct handling of the module, please
contact your local distributor or, alternatively,
PR electronics A/S, Lerbakken 10, DK-8410 Rønde, Denmark,
tel: +45 86 37 26 77.
Mounting and connection of the module should comply with national legislation
for mounting of electric materials, i.a. wire cross section, protective fuse, and
location. Descriptions of Input / Output and supply connections are shown in the
block diagram and side label.

HOW TO DISMANTLE SYSTEM 2200
The back panel of the module is detached from the housing by way of a screw-
driver as shown in picture 1.
On a module with knobs, these may have to be removed before the PCB can be
taken out as shown in picture 2.
After this, the back panel can be pulled out together with the PCB, but please
notice the position of the PCB as there is a number of different positions in the
house. Do not pull the wires unnecessarily, instead pull the PCB, see picture 3.
Switches and jumpers can now be moved.
When assembling the back plate and housing, please make sure no wires are
stuck.
17
Picture 1: Dismantlement of back plate
and housing.
Picture 2: Removal of knobs.
Picture 3: Removal of PCBs for adjustment of DIP-switches
and replacement of jumpers.
DECLARATION OF CONFORMITY
As manufacturer
PR electronics A/S
Lerbakken 10
DK-8410 Rønde
hereby declares that the following product:
Type: 2220
Name: Switchmode power supply
is in conformity with the following directives and standards:
The EMC Directive 2004/108/EC and later amendments
EN 61326-1
For specification of the acceptable EMC performance level, refer to the
electrical specifications for the module.
The Low Voltage Directive 2006/95/EC and later amendments
EN 61010-1
The CE mark for compliance with the Low Voltage directive was affixed in the
year: 1997
Rønde, 7 October 2009 Kim Rasmussen
Manufacturer’s signature
16

OUTPUT:
The output is adjustable from front potentiometer in the range 5...24 VDC. A
green LED indicates active output. Short-circuit protection limits the current to
typ. 2.2 Amp. Output is isolated by 3.75 kVAC from input.
ELECTRICAL SPECIFICATIONS:
Specifications range:
-20°C to +60°C
Common specifications:
Internal consumption max.......................... 4 W
Isolation test / operation ............................ 3.75 kVAC / 250 VAC
Transformer ................................................ EN 60742
Temperature coefficient.............................. 0.05% / °C
Mains effect (±10%)................................... < ±30 mV
Transient stability (10%-max. load)............ < 250 mV
EMC immunity influence ............................ < ±0.5%
Relative air humidity................................... < 95% RH (non-cond.)
Dimensions (HxWxD).................................. 80.5 x 35.5 x 84.5 mm
Protection degree....................................... IP50
Weight ........................................................ 425 g
Input:
Input voltage............................................... 21.6...26.4 VAC
99...121 VAC
108...132 VAC
207...253 VAC
Frequency................................................... 50...60 Hz
Output:
Output voltage............................................ 4.75...25.2 VDC
Output power ............................................. Max. 7 W
Output current............................................ 1 A / 5 VDC
0.55 A / 12 VDC
0.45 A / 15 VDC
0.3 A / 24 VDC
19
SWITCHMODE
POWER SUPPLY
2220
• Mains voltage input
• Isolation 3.75 kVAC
• Adjustable output 5...24 VDC, max. 7 W
• Short-circuit protection
• Thermal overload protection
• Standard 11-pole relay socket
APPLICATIONS:
General power supply for smaller measurement systems requiring fixed stabilized
24 VDC, or supply for any other sensors, transmitters or as a general
variable power supply 5 to 24 VDC.
Two units may be connected in series for plus / minus or higher output voltage.
TECHNICAL CHARACTERISTICS:
The unit is based on secondary switchmode technology enabling an adjustable
output with a minimum loss of power. Isolation test voltage between input and
output is 3.75 kVAC. This makes the unit suitable for PELV/SELV applications. The
double-isolated safety transformer includes a 100°C thermal fuse which switches
off the input before the transformer is overheated. When the temperature returns
below 100°C the thermal fuse will automatically switch on the power supply.
MOUNTING:
The 2220 is for standard 11-pole socket mounting in all positions. To achieve
maximum cooling, vertical position and a small distance (10 mm) between
neighbouring units are recommended.
INPUT:
Standard supply voltages in accordance to the specifications. Galvanic isolation
is ensured by the double-isolated safety transformer.
18

21
Load effect, (10%-max. load) .................... < 1.5% / A
Current limit (short circuit).......................... Typ. 2.2 A
Output ripple .............................................. < 20 mVRMS
GOST R approval:
VNIIM, Cert. No. ......................................... See www.prelectronics.com
Observed authority requirements: Standard:
EMC 2004/108/EC ..................................... EN 61326-1
LVD 2006/95/EC......................................... EN 61010-1
PELV/SELV.................................................. IEC 364-4-41 and EN 60742
20
ORDER:
BLOCK DIAGRAM:
Output
Type Version
2220 110 VAC : A
230 VAC : B
24 VAC : D
120 VAC : F
Special (5...24 V) : 0
24 VDC : 1
15 VDC : 2
12 VDC : 3
5 VDC : 4
For pricing, or any further, informationplease contact Omni Instruments Ltd
Tel: +44 (0)845 9000 601 or visit our website at www.omniinstruments.co.uk

PR electronics A/S tilbyder et bredt program af analoge og digitale
signalbehandlingsmoduler til industriel automation. Programmet
består af Isolatorer, Displays, Ex-barrierer, Temperaturtransmittere,
Universaltransmittere mfl. Vi har modulerne, du kan stole på i selv
barskemiljøermedelektrisk støj,vibrationerogtemperaturudsving,
og alle produkter opfylder de strengeste internationale standarder.
Vores motto »Signals the Best« er indbegrebet af denne filosofi
– og din garanti for kvalitet.
PR electronics A/S offers a wide range of analogue and digital
signal conditioning modules for industrial automation. The product
range includes Isolators, Displays, Ex Interfaces, Temperature
Transmitters, and Universal Modules. You can trust our products
in the most extreme environments with electrical noise, vibrations
and temperature fluctuations, and all products comply with the
most exacting international standards. »Signals the Best« is the
epitome of our philosophy – and your guarantee for quality.
PR electronics A/S offre une large gamme de produits pour le
traitement des signaux analogiques et numériques dans tous
les domaines industriels. La gamme de produits s’étend des
transmetteurs de température aux afficheurs, des isolateurs
aux interfaces SI, jusqu’aux modules universels. Vous pouvez
compter sur nos produits même dans les conditions d’utilisation
sévères, p.ex. bruit électrique, vibrations et fluctuations de
température. Tous nos produits sont conformes aux normes
internationales les plus strictes. Notre devise »SIGNALS the
BEST« c’est notre ligne de conduite - et pour vous l’assurance
de la meilleure qualité.
PR electronics A/S verfügt über ein breites Produktprogramm
an analogen und digitalen Signalverarbeitungsmodule für die in-
dustrielle Automatisierung. Dieses Programm umfasst Displays,
Temperaturtransmitter, Ex- und galvanische Signaltrenner,
und Universalgeräte. Sie können unsere Geräte auch unter
extremen Einsatzbedingungen wie elektrisches Rauschen,
Erschütterungen und Temperaturschwingungen vertrauen, und
alle Produkte von PR electronics werden in Übereinstimmung
mit den strengsten internationalen Normen produziert. »Signals
the Best« ist Ihre Garantie für Qualität!
DK
UK
FR
DE
Programmable displays with a wide se-
lection of inputs and outputs for display of temperature,
volume and weight, etc. Feature linearisation, scaling,
and difference measurement functions for programming
via PReset software.
Interfaces for analogue and digital
signals as well as HART®signals between sensors / I/P
converters / frequency signals and control systems in Ex
zone 0, 1 & 2 and for some modules in zone 20, 21 & 22.
Galvanic isolators for analogue and digital
signals as well as HART®signals. A wide product range
with both loop-powered and universal isolators featuring
linearisation, inversion, and scaling of output signals.
PC or front programmable modules with
universal options for input, output and supply. This range
offers a number of advanced features such as process
calibration, linearisation and auto-diagnosis.
A wide selection of transmitters for DIN
form B mounting and DIN rail modules with analogue
and digital bus communication ranging from application-
specific to universal transmitters.
Displays
Temperature
Isolation
Ex interfaces
Universal
Other manuals for 2220
1
Table of contents
Other PR Power Supply manuals
Popular Power Supply manuals by other brands

Mode Lighting
Mode Lighting Tiger installation manual

Kenwood
Kenwood PS-60 instruction manual

American Magnetics
American Magnetics 05100PS-430-601 Installation, operation and maintenance instructions

StarTech.com
StarTech.com EPS12V instruction manual

BCP
BCP PUOOUBZ How to install

Bluetti
Bluetti EP800 user manual