SIKA TU 7052 User manual

SIKA Dr. Siebert & Kühn GmbH & Co. KG Struthweg 7–9 34260 Kaufungen Germany
+49 5605 803-0 +49 5605 803-555 info@SIKA.net www.SIKA.net
© SIKA •Ba TU7052_en •08/2009 (03/2019).
TU 7052 – Electronic frequency divider for flow and volumetric
sensors
Contents page
0About this operating manual ......................................................................................... 2
1Device description......................................................................................................... 3
1.1 Intended use........................................................................................................ 3
2Safety instructions......................................................................................................... 3
3Connections and functions............................................................................................ 4
4Installation and electrical connection............................................................................. 4
4.1 Rail mounting....................................................................................................... 5
4.2 Electrical connection............................................................................................ 5
5Divider setting ............................................................................................................... 7
6Commissioning ............................................................................................................. 7
7Maintenance, decommissioning and disposal ............................................................... 7
8Technical data .............................................................................................................. 8
8.1 Dimensions.......................................................................................................... 8
Please keep this operating manual for future reference.
If the appliance is resold, please provide the operating manual along with it.
Operating manual

TU 7052 About this operating manual
- 2 - © SIKA •Ba TU7052_en •08/2009 (03/2019)
0 About this operating manual
•The operating manual is aimed at specialists and semi-skilled personnel.
•Before each step, read through the relevant advice carefully and keep to the specified order.
•Thoroughly read and understand the information in the section “Safety instructions”.
If you have any problems or questions, please contact your supplier or contact us directly at:
Dr. Siebert & Kühn GmbH & Co. KG
Struthweg 7-9 • D - 34260 Kaufungen
+49 5605 803-0 • +49 5605 803-
555
info@SIKA.net • www.SIKA.net
Hazard signs and other symbols used:
DANGER! Risk of death due to electric current!
This sign indicates dangers which could lead to serious health defects or to death.
CAUTION! / WARNING! Risk of injury!
This sign indicates dangers that cause personal injuries that can lead to health defects or cause con-
siderable damage to property.
CAUTION! Material damage!
This sign indicates actions which could lead to possible damage to material or environmental damage.
ADHERE TO OPERATING MANUAL!
NOTICE!
This sign indicates important notices, tips or
information.
NO DOMESTIC WASTE!
The device must not be disposed of together
with domestic waste!
Pay attention to and comply with information
that is marked with this symbol.
Follow the specified instructions and steps.
Adhere to the given order.
Check the specified points or notices.
Reference to another section, document or
source.
•Item
Copyright notice:
The reproduction, distribution and utilization of this operating manual as well as the communication of its contents
to others without express authorization is prohibited. Offenders will be held liable for the payment of damages. All
rights reserved in the event of the grant of a patent, utility model or design.

Device description TU 7052
Technical changes reserved - 3 -
1 Device description
The frequency divider TU 7052 divides the high frequencies of the input signal in order to provide a
lower pulsed output signal. The division ratio can be set freely between 1:1 and 1:999.
All SIKA flow or volumetric sensors can be connected to the TU 7052.
Design / Components:
Casing:
The TU 7052 has a plastic casing for rail mounting in
accordance with DIN EN 60715.
Terminals:
For the electrical connection of TU 7052.
Front panel:
Protects the electronics against static discharges and
mechanical damage.
Coding switches:
The coding switches for adjusting the division ration are
located behind the front panel.
Electrical connection:
Connecting diagrams for the supply voltage, the inputs
and the outputs are printed on both sides of the casing.
Type plate:
The type plate displays the serial and manufacturing
number.
Scope of delivery:
•1x TU 7052.
•1x Pull-up / Pull-down resistor 5kΩ: Fastened to the side of the plastic casing of TU 7052.
1.1 Intended use
The frequency divider TU 7052 should only be used to divide the frequency signals of SIKA flow or
volumetric sensors.
The suitability of other sensors must be tested prior to the delivery of TU 7052. Please contact your
supplier or SIKA for more details.
The operational safety of the supplied equipment is only guaranteed if it is operated according to its
intended use. The specified limit values (see 8 “Technical data”) should never be exceeded.
Always make sure that TU 7052 is suitable for your requirements prior to installation and commis-
sioning.
2 Safety instructions
Before you install the TU 7052, read through this operating manual carefully. If the instruc-
tions contained within it are not followed, in particular the safety guidelines, this could result
in danger for people, the environment, and the device and the system it is connected to.
The TU 7052 correspond to the state-of-the-art technology. This concerns the accuracy, the operat-
ing mode and the safe operation of the device.
In order to guarantee that the device operates safely, the operator must act competently and be
conscious of safety issues.

TU 7052 Connections and functions
- 4 - © SIKA •Ba TU7052_en •08/2009 (03/2019)
SIKA provides support for the use of its products either personally or via relevant literature. The
customer verifies that our product is fit for purpose based on our technical information. With this
verification all hazards and risks are transferred to our customers; our warranty is not valid.
Qualified personnel:
The personnel who are charged for the installation, operation and maintenance of TU 7052 hold
a relevant qualification.
This can be based on training or relevant tuition. The personnel must be aware of this operating
manual and have access to it at all times.
The electrical connection should only be carried out by a fully qualified electrician.
General safety instructions:
In all work, the existing national regulations for accident prevention and safety in the workplace
must be complied with. Any internal regulations of the operator must also be complied with,
even if these are not mentioned in this manual.
Degree of protection IP20:
The device is not intended for outdoor use or for use in damp conditions.
Special safety instructions:
Warnings that are specifically relevant to individual operating procedures or activities can be found
at the beginning of the relevant sections of this operating manual.
3 Connections and functions
Connections:
: Sensor NPN / PNP connection.
: Inductive sensor connection.
: Output circuit connection.
: Supply voltage connection.
Function:
The frequency signal at the input of TU 7052 is divided by the set val-
ue of the divider and provided at the outputs as a square-wave pulse
signal.
The output frequency is calculated at follows:
Divider
frequencyInput
frequencyOutput =
With a corresponding circuit, the NPN/PNP output and the optocou-
pler output can be used simultaneously.
4 Installation and electrical connection
Prior to installation and electrical connection:
Switch off the system.
Make sure that the system is isolated from all possible sources of supply and is completely de-
energised.

Installation and electrical connection TU 7052
Technical changes reserved - 5 -
4.1 Rail mounting
The TU 7052 has a plastic casing for rail mounting in accordance with DIN EN 60715. It can be
mounted before or after electrical connection.
Place the TU 7052 on the mounting rail from above and ensure that the plastic casing locks in-
to position.
4.2 Electrical connection
WARNING! Danger of death due to electrical hazard!
The electrical connection of TU 70xx should only be carried out by a fully qualified electrician.
CAUTION! Material damage!
The TU 7052 may be damaged if the connection cables are swapped.
Only connect TU 7052 to the specified connections.
4.2.1 Flow or volumetric sensor connection
All SIKA flow or volumetric sensors can be connected to TU 7052.
CAUTION! Material damage!
Malfunctioning and damage may occur if several sensors are connected.
Only connect one flow or volumetric sensor.
4.2.1.1 NPN / PNP sensors
For a sensor current consumption of ≤ 50 mA (> 50 mA), the supply voltage (+U) is connected to
terminal 41 (23). The sensor signal () is connected to terminal 42 and the ground (GND) to con-
nection cable 21.
Integrated pull-up (pull-down) resistor:
The following circuit with an external resistor is not required if a sensor with integrated resis-
tor is connected.
NPN sensor:
The supplied resistor should be connected between terminal 42 and termi-
nal 41 (23) for NPN sensors.
PNP sensor:
The supplied resistor should be connected between terminal 42 and termi-
nal 21 for PNP sensors.
41(23)
42
21
41(23)
42
21

TU 7052 Installation and electrical connection
- 6 - © SIKA •Ba TU7052_en •08/2009 (03/2019)
4.2.1.2 Inductive sensor
CAUTION! Material damage!
A pull-up (pull-down) resistor should not be used if inductive sensors
are connected.
Remove any existing pull-up (pull-down) resistors.
•The inductive sensor is connected to TU 7052 at terminals 31 and 33.
4.2.2 Output wiring
The NPN/PNP output and the optocoupler output can be used simultaneously.
4.2.2.1 NPN/PNP output
The NPN and PNP output of TU 7052 each have an internal 5kΩ pull-up /
pull-down resistor. This ensures that both signals can be used simultane-
ously.
•The NPN signal and PNP signal are collected via terminal 12 and termi-
nal 11 respectively.
4.2.2.2 Optocoupler output
The optocoupler of TU 7052 has a direct open-collector output which can be connected as either a
NPN or PNP output.
CAUTION! Material damage!
The optocoupler output is not equipped with a protective circuit. The
load should not exceed max. 30 VDC and 10 mA.
NPN wiring:
•Connect an external pull-up resistor between terminals 32 and 23.
The NPN signal can be collected at terminal 32.
PNP wiring:
•Connect an external pull-down resistor between terminals 13 and 22.
The PNP signal can be collected at terminal 13.
4.2.3 Supply voltage connection
The TU 7052 can be powered with a supply voltage of between 12…24 VDC.
•Connect the supply voltage to terminals 23 (+U) and 22 (0 V) of
TU 7052.
VTI SENSOR:
When using a VTI flow sensor, the power supply should not fall below 12 V.

Divider setting TU 7052
Technical changes reserved - 7 -
5 Divider setting
The divider is set via the three coding switches of TU 7052. Use a screwdriver to set the switches
to a value between 0 and 9.
The value of the respective switch is displayed on the front panel.
The desired value of the divider is simply set, like written a number, from
top to bottom:
The top coding switch is used to set the hundreds (*100),
the middle coding switch is used to set the tens (*10) and
the bottom coding switch is used to set the units (*1).
SPECIAL SETTINGS:
Setting "0 0 0" switches off the output.
The frequency is not divided at setting "0 0 1".
6 Commissioning
Commissioning occurs after the electrical connections have been carried out and tested:
Switch on the supply voltage.
The TU 7052 is ready for operation:
As soon as a medium passes through the connected flow or volumetric sensor, the frequency of
the input signal is divided by the set value of the divider. The lower square-wave pulse signal ap-
pears at the outputs.
7 Maintenance, decommissioning and disposal
Maintenance:
The TU 7052 is maintenance-free and cannot be repaired by the user. In the unlikely event of a de-
fect, the device has to be returned to the manufacturer for repair work.
TIP:
Check all connection cables and the supply voltage to eliminate other error sources in ad-
vance.
Decommissioning:
Switch off the system.
Make sure that the system is isolated from all possible sources of supply and is completely de-
energised.
Disconnect the electrical connections and remove TU 7052 from the mounting rail.
Disposal:
Compliant with the Directives 2011/65/EU (RoHS) and 2012/19/EU (WEEE)*, the device
must be disposed of separately as electrical and electronic waste.
Take the TU 7052 to your local recycling plant
or
send it back to your supplier or to SIKA for correct disposal.
* WEEE reg. no.: DE 25976360

TU 7052 Technical data
- 8 - © SIKA •Ba TU7052_en •08/2009 (03/2019)
8 Technical data
The technical data of customised versions may differ from the data in the instructions. Please ob-
serve the information specified on the type plate.
TU 7052
Input signal characteristics (sensor)
Input frequency
0 ... max. 1.700 Hz
Signal level NPN / PNP
"Low": < 3,3 V
"High" > 6 V
Signal level sinus signal (inductive)
10 … 200 mV
Sensor supply
USensor = USupply - < 2 VDC
Frequency output characteristics
Divider (division range)
1:1 … 1:999 •can be set via rotary switches
Type of signal
Square-wave signal • duty cycle 1:1
NPN/PNP output: (short-circuit proof)
- Signal current
Max. 20 mA, limited current
Optocoupler output:(without a protective circuit)
- Max. load voltage
≤30 VDC
- Max. load current
≤ 10 mA
- Load resistance
5 kΩ(recommendation)
Electrical characteristics
Supply voltage (USupply)
12 … 24 VDC ±10%
Current consumption
< 25 mA at 24 VDC (without a sensor) •max. 1 W
Electrical safety measures
Reverse polarity protection (supply voltage)
Protection class
IP 20
further technical data
Ambient temperature
0 … 60 °C
Storage temperature
-10 … +80 °C
Casing
Plastic casing for rail mounting
8.1 Dimensions